Jun Keun Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jun Keun Chang has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Chanil Chung
Digital Bio Technology, Inc., San 56-1 Shinlim-dong, Kwanak-gu Seoul, Korea
5 shared publicationsSeok Chung
Biological Engineering Division, Massachusetts Institute of Technology, 77 Massachusetts Ave. NE47-322, Cambridge, MA, USA
5 shared publicationsC. Chung
Bldg 136, Seoul National University
4 shared publicationsD. C. Han
Seoul National University
4 shared publicationsKeunchang Cho
Digital Bio Technology, Inc., San 56-1 Shinlim-dong, Kwanak-gu Seoul, Korea
4 shared publicationsDong-Chul Han
School of Mechanical and Aerospace Engineering, Seoul National University, San 56-1 Shinlim-dong, Kwanak-gu Seoul, Korea
3 shared publications
Latest Publications
- 27 July 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (10) , 1381-1383
Expansion channel for microchip flow cytometers
This paper presents a novel way of designing a flow focusing channel for microchip flow cytometers. With this method we increased throughput and sensitivity of particle detection at the same time. Generally, to increase the detection throughput of a flow cytometer, the speed of the flow inside the focusing channel needs to be increased, hence reducing the time of exposure to laser beam. With the shorter exposure time, both the fluorescence and scatter signal from the target particles become dimmer. To increase the sensitivity of signal detection, however, the speed of the flow should be decreased so as to decrease throughput of detection. To overcome this dilemmatic problem, we integrated an expansion channel inside a focusing channel. Signals from particles in an expansion channel were about 10 times brighter than those in a normal channel. With this enhanced sensitivity, we could also speed up the inlet flow, which in turn increases the overall throughput of detection.
- 27 July 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (10) , 1381-1383
Expansion channel for microchip flow cytometers
This paper presents a novel way of designing a flow focusing channel for microchip flow cytometers. With this method we increased throughput and sensitivity of particle detection at the same time. Generally, to increase the detection throughput of a flow cytometer, the speed of the flow inside the focusing channel needs to be increased, hence reducing the time of exposure to laser beam. With the shorter exposure time, both the fluorescence and scatter signal from the target particles become dimmer. To increase the sensitivity of signal detection, however, the speed of the flow should be decreased so as to decrease throughput of detection. To overcome this dilemmatic problem, we integrated an expansion channel inside a focusing channel. Signals from particles in an expansion channel were about 10 times brighter than those in a normal channel. With this enhanced sensitivity, we could also speed up the inlet flow, which in turn increases the overall throughput of detection.
- 10 January 2006
- Published by Springer Nature in Microsystem Technologies
- Vol. 12 (8) , 746-753
Microfabricated fluorescence-activated cell sorter through hydrodynamic flow manipulation
- 10 January 2006
- Published by Springer Nature in Microsystem Technologies
- Vol. 12 (8) , 746-753
Microfabricated fluorescence-activated cell sorter through hydrodynamic flow manipulation
- 1 January 2004
- Published by Springer Nature in Microsystem Technologies
- Vol. 10 (2) , 81-88
Multi-height micro structures in poly(dimethyl siloxane) lab-on-a-chip
- 1 January 2004
- Published by Springer Nature in Microsystem Technologies
- Vol. 10 (2) , 81-88
Multi-height micro structures in poly(dimethyl siloxane) lab-on-a-chip
- 1 October 2003
- Published by Springer Nature in Microsystem Technologies
- Vol. 9 (8) , 555-558
Fabrication of the PDMS microchip for serially diluting sample with buffer
- 1 October 2003
- Published by Springer Nature in Microsystem Technologies
- Vol. 9 (8) , 555-558
Fabrication of the PDMS microchip for serially diluting sample with buffer
- 1 October 2003
- Published by Springer Nature in Microsystem Technologies
- Vol. 9 (8) , 525-533
Plastic microchip flow cytometer based on 2- and 3-dimensional hydrodynamic flow focusing
- 1 October 2003
- Published by Springer Nature in Microsystem Technologies
- Vol. 9 (8) , 525-533
Plastic microchip flow cytometer based on 2- and 3-dimensional hydrodynamic flow focusing
- 17 September 2003
- Published by Elsevier in Journal of Chromatography A
- Vol. 1013 (1-2) , 111-122
Effects of peak anomalies with the hydrophilic or hydrophobic properties of reservoirs during serial injection on a capillary electrophoresis microchip
- 17 September 2003
- Published by Elsevier in Journal of Chromatography A
- Vol. 1013 (1-2) , 111-122
Effects of peak anomalies with the hydrophilic or hydrophobic properties of reservoirs during serial injection on a capillary electrophoresis microchip
- 19 August 2003
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 14 (1) , 6-14
Rapid three-dimensional passive rotation micromixer using the breakup process
- 19 August 2003
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 14 (1) , 6-14
Rapid three-dimensional passive rotation micromixer using the breakup process
- 1 August 2003
- Published by Springer Nature in Biotechnology and Bioprocess Engineering
- Vol. 8 (4) , 233-239
Functional integration of serial dilution and capillary electrophoresis on a PDMS microchip
- 1 August 2003
- Published by Springer Nature in Biotechnology and Bioprocess Engineering
- Vol. 8 (4) , 233-239
Functional integration of serial dilution and capillary electrophoresis on a PDMS microchip
- 1 March 1997
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 43 (2) , 36
DEVELOPMENT OF A PULSATILE MEMBRANE OXYGENATOR USING LVAD
- 1 March 1997
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 43 (2) , 36
DEVELOPMENT OF A PULSATILE MEMBRANE OXYGENATOR USING LVAD
- 1 July 1993
- Vol. 39 (3) , M332-6
The fluid dynamic effect on protein adsorption in left ventricular assist devices.
Plasma protein adsorption onto an artificial surface is strongly influenced by not only the surface characteristics of materials, but also by the fluid dynamics inside the blood pump, and it would influence subsequent platelet adhesion or activation, which plays a major role in the initiation of thrombus formation at the blood-material interface in vivo. In vitro flow visualization of an electrohydraulic LVAD was performed by a video camera (CCD, Hitachi) and an image processor (PC VISION PLUS) with an IBM PC. The electrohydraulic LVADs were implanted in mongrel dogs of approximately 20 kg. The authors sectioned the blood contacted ventricle after animal death according to the level of shear rate. Because analysis of adsorbed protein might be influenced by the size of the ventricle segment, the number of segments was limited to eight per ventricle. Platelet adhesion and its morphology were observed by scanning electron microscopy (SEM). Adsorbed plasma proteins (fibrinogen, albumin, and IgG) on each segment were quantified by enzyme linked immunosorbent assay (ELISA). The specimens were soaked in 2% (wt/vol) SDS/PBS for 2 days and the released protein concentration assessed. A well developed large vortex was observed at the center of the artificial ventricle. Polyurethane blood pumps displayed different degrees of protein adsorption and subsequent platelet adhesion on each segment.
- 1 July 1993
- Vol. 39 (3) , M332-6
The fluid dynamic effect on protein adsorption in left ventricular assist devices.
Plasma protein adsorption onto an artificial surface is strongly influenced by not only the surface characteristics of materials, but also by the fluid dynamics inside the blood pump, and it would influence subsequent platelet adhesion or activation, which plays a major role in the initiation of thrombus formation at the blood-material interface in vivo. In vitro flow visualization of an electrohydraulic LVAD was performed by a video camera (CCD, Hitachi) and an image processor (PC VISION PLUS) with an IBM PC. The electrohydraulic LVADs were implanted in mongrel dogs of approximately 20 kg. The authors sectioned the blood contacted ventricle after animal death according to the level of shear rate. Because analysis of adsorbed protein might be influenced by the size of the ventricle segment, the number of segments was limited to eight per ventricle. Platelet adhesion and its morphology were observed by scanning electron microscopy (SEM). Adsorbed plasma proteins (fibrinogen, albumin, and IgG) on each segment were quantified by enzyme linked immunosorbent assay (ELISA). The specimens were soaked in 2% (wt/vol) SDS/PBS for 2 days and the released protein concentration assessed. A well developed large vortex was observed at the center of the artificial ventricle. Polyurethane blood pumps displayed different degrees of protein adsorption and subsequent platelet adhesion on each segment.