CEClaus-Peter Ernst

Claus-Peter Ernst

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Claus-Peter Ernst has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Does professional preventive care benefit from additional subgingival irrigation?

    by Claus-Peter Ernst, Marcus Pittrof, Brita Willershausen, Silke Fürstenfelder

    The effect of an oral irrigator (Water Pik, Intersanté) with a subgingival tip (Pik Pocket Subgingival Tip, Intersanté) in the reduction of gingivitis was investigated in a single-blind three-group study involving 45 volunteers (age 46.2±10.2). All volunteers (inclusion criteria: gingivitis or a superficial periodontitis) were examined and underwent professional tooth cleaning at the first appointment. They were then randomly distributed in three groups: one group used the irrigator with the subgingival tip once daily with just tap water, in addition to their regular oral hygiene; another group also used an herbal-based mouth rinse (Parodontax, GlaxoSmithkline) in the water of the irrigator; a third group did not use an irrigator or any irrigant and therefore served as control. All groups received professional oral care education at each appointment. The investigation period was 3 months. At baseline and after 4, 8, and 12 weeks, the plaque index (PI, scores 0–5), gingival index (GI, scores 0–3), bleeding index (BI scores 0–5), and sulcus fluid flow rate (SFFR, Periotron 6000) at the Ramfjord teeth were scored. At baseline and after 3 months, the probing depth (millimeters) was measured at six surfaces of all teeth. A significant reduction in BI, PI, GI, probing depth, and SFFR was observed within 3 months. With all volunteers, however, there was no statistically significant difference ( p ≥0.05, Wilcoxon-test, SAS 6.04) between the three groups at any time. The additional use of the Water Pik irrigator with the Pik Pocket subgingival irrigation device with or without an herbal mouth rinse showed no clinical benefit over professional education in oral hygiene alone.


  • Determination of polymerization shrinkage stress by means of a photoelastic investigation

    by Claus-Peter Ernst, Gerrit R. Meyer, Kerstin Klöcker, Brita Willershausen


    • 1 January 2004
      • Vol. 6  (1) , 25-32

    Marginal integrity of self- and total-etching adhesives in two different application protocols.

    by Claus-Peter Ernsta, Tim Kötter, Anja Victor, Kerem Canbek, Mathias Brandenbusch, Brita Willershausen

    The aim of this study was to evaluate the marginal integrity of four self-etching adhesives (Prompt L-Pop III, Resulcin Aqua Prime & MonoBond N, AC Bond, AC Bond + Desensitizer) and three total-etch adhesives (Opti-Bond FL, Excite, Gluma Comfort Bond) in two different application protocols. Standardized MOD cavities (n = 40) were prepared in 280 extracted human teeth (one cervical margin in cementum, one in enamel). In one application protocol, the adhesive was applied prior to placement of the Tofflemire matrix (n = 20); in the other, the metal matrix was placed first (n = 20). Light curing was carried out from the occlusal aspect. After thermocycling (5000 times, 5 degrees C and 55 degrees C), specimens were immersed in 2% methylene blue for 10 s. Then the median percentages of dye-penetrated margins (surface analysis) were determined separately for the cervical cementum, cervical enamel, and lateral enamel margins of the proximal boxes. At the cervical cementum margins, statistically significantly worse results were obtained for all adhesives when the matrix system was placed prior to application of the adhesive. In the cervical enamel margins, OptiBond FL, Gluma Comfort Bond, and Prompt L-Pop III performed significantly better when the adhesive was applied prior to the matrix. On lateral enamel margins, only OptiBond FL and Resulcin Aqua Prime showed significantly less dye penetration if the matrix was placed first. Most of the total-etch materials produced marginal integrity significantly superior to that of the majority of the self-etching materials. Due to a significant influence of the application protocol on marginal integrity, it is strongly recommended to apply the adhesive system before placement of the matrix.


    • 1 January 2004
      • Vol. 6  (2) , 141-50

    Depth of cure of LED vs QTH light-curing devices at a distance of 7 mm.

    by Claus-Peter Ernst, Gerrit R Meyer, Julia Müller, Elmar Stender, M Oliver Ahlers, Brita Willershausern

    To determine the depth of cure of 5 blue LED curing devices compared to that obtained with 3 QTH curing devices. The LED curing devices tested were 1) e-Light: 40 s; 2) Elipar FreeLight: 40 s; 3) Elipar FreeLight 2: 20 s and 40 s; 4) Ultra-Lume LED 2: 20 s and 40 s; 5) LEDemetron 1: 20 s and 40 s. The QTH curing devices tested were 1) Optilux 501: standard light guide 20 s and 40 s, turbo light guide 20 s; 2) Elipar TriLight: 40 s; 3) Astralis 10: 20 s. Surface hardness was measured (Zwick Z2.5/TS1S) 10 min after exposure on the top and bottom surface of resin samples (Tetric Ceram A3, 1 to 5 mm; 0.5 mm increment, diameter 5 mm, n = 9) which were cured at a distance of 7 mm from the bottom of the sample to the light-guide tip to simulate a Class II curing situation. A reference sample was cured under direct contact with the light guide. The reference sample with the greatest top surface hardness of all devices measured served as the overall control. A bottom/top surface hardness ratio of > or = 80% of the reference sample cured at zero distance was defined as clinically acceptable for safe curing. A descriptive statistical analysis was carried out. With QTH lamps, the mean maximum resin composite sample thickness which cured sufficiently (relative surface ratio > or = 80%) was: 3 mm for Optilux 501, standard light guide, 40 s; 2.5 mm for Trilight, 40 s; and 1.5 mm for Astralis 10, 20 s. The first-generation LED curing devices FreeLight and GC e-Light, both applied for 40 s, and the Optilux 501 operated for 20 s with the standard and the turbo light guide could not sufficiently cure a 1-mm-thick sample at a distance of 7 mm. The new FreeLight 2 and the Ultra-Lume LED 2 cured resin samples up to 2.5 mm thick in 40 s with a relative surface ratio > or = 80%, while no sufficient depth of cure was found after 20 s exposure time for the FreeLight 2. However, a 1.5-mm depth of cure with the Ultra-Lume LED 2 and the LEDemetron 1 with the 13/11 mm light guide was obtained after 20 s. The LEDemetron 1 equipped with a 13/8 mm light guide reached a depth of cure of 2.0 mm. No significant difference was found between the Elipar FreeLight 2, Ultra-Lume LED 2, and LEDemetron 1 in their overall curing potential (linear statistical model, 5% level, Bonferroni-correction) given 40 s or 20 s of exposure time. Application of the first-generation LED curing devices FreeLight and e-Light did not ensure clinically sufficient depths of cure, while the new high-power LED curing devices FreeLight 2, Ultra-Lume LED 2, and LEDemetron 1 showed a curing potential equal to the Optilux 501, given 40 s of exposure time.


    • 1 January 2004
      • Vol. 6  (4) , 293-9

    In vitro shear bond strength of self-etching adhesives in comparison to 4th and 5th generation adhesives.

    by Claus-Peter Ernest, Marcus Holzmeier, Brita Willershausen

    To determine the shear bond strength (SBS) of different established (Resulcin Aqua Prime & Monobond N: RA, Prompt L-Pop III: PLP) and experimental (AC-Bond: AC, AC-Bond + Desensitizer: ACD) self-etching adhesives in comparison to fourth (Optibond FL: FL) and fifth generation (Excite: EX, Gluma Comfort Bond: CB) adhesives. All adhesives were applied on flat enamel and dentin surfaces and light cured following manufacturers' directions. Tetric Ceram A2 composite cylinders 3.5 mm in diameter and 2.0 mm in height were sheared off (1 mm/min) after thermocycling (5 to 55 degrees C, 5000x). The t-test (5% level, Bonferroni-correction) was used for statistical analysis. SBS in enamel: RA: 27.0+/-5.8 MPa, PLP: 15.9+/-3.4 MPa, AC: 28.1+/-4.4 MPa, ACD: 22.2+/-4.1 MPa, FL: 33.2+/-3.2 MPa, EX: 30.5+/-5.1 MPa, CB: 30.1+/-3.7 MPa. SBS in dentin: RA: 25.8+/-5.7 MPa, PLP: 20.7+/-2.9 MPa, AC: 27.0+/-4.5 MPa, ACD: 20.7+/-3.7 MPa, FL: 34.4+/-3.8 MPa, EX: 30.0+/-4.6 MPa, CB: 27.9+/-2.6 MPa. FL resulted in significantly (p < 0.002) higher SBS in enamel and dentin than RA, AC, ACD, and PLP, and in higher SBS to dentin than CB. In enamel and dentin, RA performed significantly superior to PLP, but was not different from AC and ACD. EX and CB were both on the same level of significance as AC and RA, but showed superior results to ACD and PLP (enamel and dentin). PLP resulted in significantly lower SBS values in enamel and dentin than all the other materials investigated, except ACD in dentin, to which it was equivalent. Resulcin Aqua Prime & Monobond N and AC-Bond were not significantly different than established 5th generation products. AC-Bond + Desensitizer and Prompt L-Pop have significantly different SBS from established 4th and 5th generation products. Future studies are required to investigate marginal integrity to determine if self-etching adhesives are an adequate alternative to one- and multi-bottle systems.


  • Two-year clinical performance of a packable posterior composite with and without a flowable composite liner

    by Claus-Peter Ernst, Kerem Canbek, Kadir Aksogan, Brita Willershausen

    The aim of the study was to evaluate the clinical performance of a packable fine hybrid dental composite (Prodigy Condensable) and the influence of the additional application of a flowable resin composite (Revolution, SDS Kerr) layer on marginal integrity after 2 years in stress-bearing posterior cavities according to the Ryge criteria. In 50 patients (40.5±17.5 years of age), 116 class II fillings (metal matrix system, glass ionomer-cement-base in 36%, rubberdam isolation in 70%) were placed, with at least two restorations per patient. The adhesive Optibond Solo Plus was used for all the restorations. In one of the two fillings in each patient, an additional layer of the flowable composite Revolution was applied in the entire cavity and separately light-cured. Baseline scores have been rated Alfa in ≥95% and Bravo in <5%. After 2 years, the results [%] of the Ryge evaluation for the two groups with/without the additional use of Revolution were: (1) Marginal Adaptation: Alfa:78/70, Bravo:16/27, Charlie:0/0, Delta:6/4; (2) Anatomic Form: Alfa:89/95, Bravo:6/2, Charlie:6/4; (3) Secondary Caries: Alfa:98/100, Bravo:2/0; (4) Marginal Discoloration: Alfa:76/68, Bravo:24/32, Charlie:0/0; (5) Surface: Alfa:90/91, Bravo:4/5, Charlie:0/0, Delta:6/4; (6) Color Match: Oscar:56/57, Alfa:44/39, Bravo:0/4, Charlie:0/0. Within the observation period (recall rate: 95%), three restorations out of 116 at baseline fractured, one restoration showed a secondary caries, one tooth received endodontic treatment, and all other restored teeth remained vital. After 2 years, no statistically significant difference (Chi-square test) in the overall survival rate between the group with the additional use of Revolution (92.8%) and that without Revolution (94.6%) was found. The combined survival rate for both groups together was 93.7% of clinically acceptable restorations.


  • Reduction of Polymerization Shrinkage Stress and Marginal Microleakage Using Soft‐Start Polymerization

    by Claus‐Peter Ernst, Nicole Brand, Ulrike Frommator, Gerd Rippin, Brita Willershausen

    Purpose: This study evaluated the influence of a soft‐start light‐curing exposure on polymerization shrinkage stress and marginal integrity of adhesive restorations.Materials and Methods: Six resin‐based composites (Pertac II, Tetric Ceram, Definite, Surefil, Solitaire, and Visio‐Molar) were adhesively bonded to a cylindrical cavity (n = 9 per material/light) in a photoelastic material. Visible light‐curing was applied using either the standard polymerization mode (800 mW/cm2 exposure duration 40 s) of the curing light (Elipar TriLight, 3M ESPE) or the exponential mode from the same device (ramp‐curing: 150 mW/cm2 to 800 mW/cm2 within the first 15 s of a total curing time of 40 s). Polymerization stress was calculated at 5 minutes, 1 hour, and 24 hours postexposure from the second‐order isochromatic curves obtained from photoelastic images (Matrox‐Inspector). Two standardized Class V preparations were made each on the facial and lingual surfaces of 80 extracted human molars and premolars. Resin restorative systems (Pertac II/EBS Multi, Tetric Ceram/Syntac, Definite/Etch&Prime 3.0, and Surefil/Prime & Bond 2.1) were exposed using both light exposure modes (n = 20). Marginal dye penetration (2% methylene blue) was investigated separately for enamel and cementum margins after thermocycling. To obtain information on equivalent depth of cure, relative surface hardness measurements were performed on resin samples of the same material at the top surface and at 1.5 mm and 3.0 mm thickness (Zwick 3212, 10 N).Results: A significant (p < .01) reduction in polymerization stress of 7.1% for Pertac II, 4.1% for Tetric Ceram, 3.6% for Definite, 3.7% for Surefil, and 6.2% for Solitaire was observed when using the exponential mode as opposed to the standard. A significant (p = .04) reduction of marginal dye penetration was found only for Pertac II/EBS Multi at the cementum margins when the soft‐start polymerization was used. For the sample thickness of 3 mm, a significant higher relative bottom to top surface ratio in favor of the standard exposure mode was found (p = .001).CLINICAL SIGNIFICANCE: Depending on the restorative material, soft‐start polymerization may lead to a significant reduction in marginal microleakage of adhesive Class V restorations. This effect might be attributable to a significantly lower polymerization stress, as seen from photoelastic analysis, and/or a decrease in the degree of conversion, as deducted from surface hardness ratios. However, the effect of soft‐start curing mode depends on the material itself, with the most effective response from hybrid resin‐based composites.