Richard Stoll
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Richard Stoll has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
V. Stachniss
5 shared publicationsVitus Stachniss
3 shared publicationsK. Pieper
2 shared publicationsA. Jablonski-Momeni
1 shared publicationA. Jablonski‐Momeni
Department of Pediatric Dentistry, Dental School
1 shared publicationA. Schulte
Universitätsklinik für Mund, Zahn- und Kieferkrankheiten, Poliklinik für Zahnerhaltungskunde, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
1 shared publication
Latest Publications
- 3 August 2010
- Published by Wiley in International Endodontic Journal
- Vol. 43 (9) , 808-817
Effectiveness of four electronic apex locators to determine distance from the apical foramen
Stoll R, Urban‐Klein B, Roggendorf MJ, Jablonski‐Momeni A, Strauch K, Frankenberger R. Effectiveness of four electronic apex locators to determine distance from the apical foramen. International Endodontic Journal, 43, 808–817, 2010. Aim To evaluate the accuracy of four electronic apex locators (EAL) in the apical region (0–3 mm short of the foramen) and to compare the precision of the readings on the display with the real position of the file in the root canal.Methodology Twenty single‐rooted extracted teeth with round root canals were used. The canal orifices were preflared, and the length to the major foramen was determined visually under a microscope. Canals were enlarged, so that a size 15 file fitted well inside the canal. Teeth were mounted in acrylic test tubes filled with physiologic saline solution. Electronic length was determined in the region between the major foramen and 3 mm short of it in 0.5 mm steps with the Dentaport ZX, Root ZX mini, Elements Diagnostic Unit and Apex Locator and Raypex 5 using files of size 10 and size 15. The data were analysed using linear regression between true length and EAL reading, Bland–Altman plots and nonparametric tests at a significance level of alpha = 0.05.Results The major foramen was detected by all EALs. With a measurement file positioned directly at the major foramen, meter readings were equivalent to a position 0.01–0.38 mm away. For the Dentaport ZX, a better accuracy using the size 15 file for the area 0–1.5 mm short of the apex was found. The differences in measurements between the two files were smaller for the other EALs. In linear regression, a good linearity for Dentaport ZX and Root ZX mini and moderate linearity for Elements Diagnostic Unit and Apex Locator and Raypex 5 were found. The slope of the measurement curve was too low (0.37–0.57) for the Raypex 5 and almost optimal for the Dentaport ZX (1.01–1.05). The Root ZX mini and the Elements Obturation Unit produced lower slope values and especially the Elements Obturation Unit revealed much higher SDs at the different measurement levels.Conclusion Amongst the four EALs, the Dentaport ZX and Root ZX mini had the best agreement between true lengths and meter readings. For the Raypex 5, an interpretation of the colour‐coded zones as distance to the foramen cannot be recommended and might lead to erroneous interpretations.
- 3 August 2010
- Published by Wiley in International Endodontic Journal
- Vol. 43 (9) , 808-817
Effectiveness of four electronic apex locators to determine distance from the apical foramen
Stoll R, Urban‐Klein B, Roggendorf MJ, Jablonski‐Momeni A, Strauch K, Frankenberger R. Effectiveness of four electronic apex locators to determine distance from the apical foramen. International Endodontic Journal, 43, 808–817, 2010. Aim To evaluate the accuracy of four electronic apex locators (EAL) in the apical region (0–3 mm short of the foramen) and to compare the precision of the readings on the display with the real position of the file in the root canal.Methodology Twenty single‐rooted extracted teeth with round root canals were used. The canal orifices were preflared, and the length to the major foramen was determined visually under a microscope. Canals were enlarged, so that a size 15 file fitted well inside the canal. Teeth were mounted in acrylic test tubes filled with physiologic saline solution. Electronic length was determined in the region between the major foramen and 3 mm short of it in 0.5 mm steps with the Dentaport ZX, Root ZX mini, Elements Diagnostic Unit and Apex Locator and Raypex 5 using files of size 10 and size 15. The data were analysed using linear regression between true length and EAL reading, Bland–Altman plots and nonparametric tests at a significance level of alpha = 0.05.Results The major foramen was detected by all EALs. With a measurement file positioned directly at the major foramen, meter readings were equivalent to a position 0.01–0.38 mm away. For the Dentaport ZX, a better accuracy using the size 15 file for the area 0–1.5 mm short of the apex was found. The differences in measurements between the two files were smaller for the other EALs. In linear regression, a good linearity for Dentaport ZX and Root ZX mini and moderate linearity for Elements Diagnostic Unit and Apex Locator and Raypex 5 were found. The slope of the measurement curve was too low (0.37–0.57) for the Raypex 5 and almost optimal for the Dentaport ZX (1.01–1.05). The Root ZX mini and the Elements Obturation Unit produced lower slope values and especially the Elements Obturation Unit revealed much higher SDs at the different measurement levels.Conclusion Amongst the four EALs, the Dentaport ZX and Root ZX mini had the best agreement between true lengths and meter readings. For the Raypex 5, an interpretation of the colour‐coded zones as distance to the foramen cannot be recommended and might lead to erroneous interpretations.
- 1 May 2010
- Published by Elsevier in Journal of Endodontics
- Vol. 36 (5) , 890-893
Adhesion of Self-adhesive Root Canal Sealers on Gutta-Percha and Resilon
- 1 May 2010
- Published by Elsevier in Journal of Endodontics
- Vol. 36 (5) , 890-893
Adhesion of Self-adhesive Root Canal Sealers on Gutta-Percha and Resilon
- 1 March 2008
- Vol. 39 (3) , 231-6
The disinfecting effect of ozonized oxygen in an infected root canal: an in vitro study.
To determine the disinfecting effect of ozonized oxygen (120 seconds from the HealOzone generator, KaVo) on Enterococcus faecalis, representing bacteria that are difficult to eliminate in the root canals of human teeth, and to compare it with the conventional irrigants: sterile physiologic sodium chloride solution (negative control group), 3% hydrogen peroxide solution, 0.2% chlorhexidine solution, 1.5% sodium hypochlorite solution, and 3% sodium hypochlorite solution (positive control group). The roots (n = 10 in each group) were sterilized, contaminated with the test microorganisms in a quantitative preparation, rinsed with the test solutions, and dried. The residual concentration of E faecalis was determined through another irrigation stage with the sodium chloride solution. The positive control group showed a significantly lower concentration of microorganisms than all the other groups, whereas the negative control group showed a significantly higher concentration compared to the other groups. The test groups showed low concentrations. Ozonized oxygen appears to be suitable for disinfecting root canal systems in cases where sodium hypochlorite is not indicated.
- 1 March 2008
- Vol. 39 (3) , 231-6
The disinfecting effect of ozonized oxygen in an infected root canal: an in vitro study.
To determine the disinfecting effect of ozonized oxygen (120 seconds from the HealOzone generator, KaVo) on Enterococcus faecalis, representing bacteria that are difficult to eliminate in the root canals of human teeth, and to compare it with the conventional irrigants: sterile physiologic sodium chloride solution (negative control group), 3% hydrogen peroxide solution, 0.2% chlorhexidine solution, 1.5% sodium hypochlorite solution, and 3% sodium hypochlorite solution (positive control group). The roots (n = 10 in each group) were sterilized, contaminated with the test microorganisms in a quantitative preparation, rinsed with the test solutions, and dried. The residual concentration of E faecalis was determined through another irrigation stage with the sodium chloride solution. The positive control group showed a significantly lower concentration of microorganisms than all the other groups, whereas the negative control group showed a significantly higher concentration compared to the other groups. The test groups showed low concentrations. Ozonized oxygen appears to be suitable for disinfecting root canal systems in cases where sodium hypochlorite is not indicated.
- 1 November 2007
- Published by Operative Dentistry in Operative Dentistry
- Vol. 32 (6) , 556-563
Survival of Inlays and Partial Crowns Made of IPS Empress After a 10-year Observation Period and in Relation to Various Treatment Parameters
Clinical Relevance: Ceramic inlays as aesthetic restorations in the posterior region can be used successfully in routine clinical therapy. Cement viscosity, the operator (experienced dentist vs dental student) and the number of surfaces have no influence on longevity.
- 1 November 2007
- Published by Operative Dentistry in Operative Dentistry
- Vol. 32 (6) , 556-563
Survival of Inlays and Partial Crowns Made of IPS Empress After a 10-year Observation Period and in Relation to Various Treatment Parameters
Clinical Relevance: Ceramic inlays as aesthetic restorations in the posterior region can be used successfully in routine clinical therapy. Cement viscosity, the operator (experienced dentist vs dental student) and the number of surfaces have no influence on longevity.
- 1 February 2007
- Published by Elsevier in Dental Materials
- Vol. 23 (2) , 145-152
On the effect of an internal light conductor on the marginal integrity of class-II composite fillings
- 1 February 2007
- Published by Elsevier in Dental Materials
- Vol. 23 (2) , 145-152
On the effect of an internal light conductor on the marginal integrity of class-II composite fillings
- 1 November 2005
- Published by Elsevier in Journal of Endodontics
- Vol. 31 (11) , 783-790
The Influence of Different Factors on the Survival of Root Canal Fillings: A 10-Year Retrospective Study
- 1 November 2005
- Published by Elsevier in Journal of Endodontics
- Vol. 31 (11) , 783-790
The Influence of Different Factors on the Survival of Root Canal Fillings: A 10-Year Retrospective Study
- 1 January 2002
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 29 (1) , 1-6
Marginal adaptation of partial crowns cast in pure titanium and in a gold alloy - an in vivo study.
- 1 January 2002
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 29 (1) , 1-6
Marginal adaptation of partial crowns cast in pure titanium and in a gold alloy - an in vivo study.
- 1 May 2001
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 28 (5) , 401-406
Marginal adaptation of cast partial crowns made of pure titanium and a gold alloy under influence of a manual burnishing technique.
- 1 May 2001
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 28 (5) , 401-406
Marginal adaptation of cast partial crowns made of pure titanium and a gold alloy under influence of a manual burnishing technique.
- 13 March 2000
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 4 (1) , 0042-0049
Influence of a high-speed polymerization method on the marginal integrity of composite fillings in class-II cavities
The aim of this study was to evaluate the effect of a rapid photopolymerization method on the marginal integrity of composite fillings. Ninety two-surface cavities were prepared in extracted human molars using the SonicSys preparation system. All cavities were bonded with one bonding agent (Syntac) and filled with a microfilled composite (Herculite XRV), a heavy filled composite (Z100 MP), and an Ormocer (Definite) in two increments. Each increment had a thickness of approximately 1.5 mm and was polymerized using either halogen light or the plasma light of Apollo 95 E. In this process, six trial groups each containing 15 fillings were created. After replicas were made, the test teeth were subjected to a thermocycling process of 2000 temperature cycles (5°C/55°C) followed by a wear simulation of 50,000 stress cycles each with 50 N. This was followed by the creation of a second set of replicas, quantitative margin analysis, and dye penetration. A significant (PPP=0.57) on the amount of continuous margin. During the dye penetration, no significant differences between the polymerization methods could be established with the materials Herculite XRV and Z100 MP (H-test according to Kruskall and Wallis). Only with the material Definite was a significantly higher dye penetration observed at the occlusal measuring point in the plasma light group. A rapid polymerization with high light intensity had no adverse effects on the margin quality within the limitations of this in vitro study. However the marginal integrity might have been influenced by the chosen adhesive system/composite resin combination, which does not represent the respective product line. Additionally, further studies ought to show which exposure time is necessary for a sufficient degree of conversion.
- 13 March 2000
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 4 (1) , 0042-0049
Influence of a high-speed polymerization method on the marginal integrity of composite fillings in class-II cavities
The aim of this study was to evaluate the effect of a rapid photopolymerization method on the marginal integrity of composite fillings. Ninety two-surface cavities were prepared in extracted human molars using the SonicSys preparation system. All cavities were bonded with one bonding agent (Syntac) and filled with a microfilled composite (Herculite XRV), a heavy filled composite (Z100 MP), and an Ormocer (Definite) in two increments. Each increment had a thickness of approximately 1.5 mm and was polymerized using either halogen light or the plasma light of Apollo 95 E. In this process, six trial groups each containing 15 fillings were created. After replicas were made, the test teeth were subjected to a thermocycling process of 2000 temperature cycles (5°C/55°C) followed by a wear simulation of 50,000 stress cycles each with 50 N. This was followed by the creation of a second set of replicas, quantitative margin analysis, and dye penetration. A significant (PPP=0.57) on the amount of continuous margin. During the dye penetration, no significant differences between the polymerization methods could be established with the materials Herculite XRV and Z100 MP (H-test according to Kruskall and Wallis). Only with the material Definite was a significantly higher dye penetration observed at the occlusal measuring point in the plasma light group. A rapid polymerization with high light intensity had no adverse effects on the margin quality within the limitations of this in vitro study. However the marginal integrity might have been influenced by the chosen adhesive system/composite resin combination, which does not represent the respective product line. Additionally, further studies ought to show which exposure time is necessary for a sufficient degree of conversion.
- 1 January 2000
- Vol. 2 (2) , 129-38
Marginal characteristics of different filling materials and filling methods with standardized cavity preparation.
The aim of the present study was to investigate the influence of different filling materials and methods on marginal integrity in Black Class I fillings. Standardized occlusal cavities were prepared in 80 extracted human molars. The preparations were filled with composite resin (1), with composite resin using the incremental technique (2), an experimental glass-fiber-reinforced (3) and polyester-reinforced (4) composite resin, a direct composite inlay (5), a ceramic insert (6), a Cerafil inlay (7), and with an experimental direct filling using Dyract AP compomer (8). Allocation of the teeth to the test groups was randomized; further processing was done on a blind basis. After the preparation of replicas, the teeth were subjected to a thermomechanical cycling process of 2,000 temperature cycles (5 degrees C/55 degrees C) and 50,000 stress cycles (50 N). This was followed by production of a second set of replicas and quantitative margin analysis by SEM (200X). A dye penetration test was then performed on the mesiodistal section. Groups 1, 2, 5, 6 and 7 displayed a good primary marginal quality, with the proportion of continuous margins reaching more than 85%. Significantly poorer results were recorded for the experimental glass-fiber-reinforced composite resins and Dyract compomer, where the proportion of perfect margins was only between 36% and 73%. In groups 1, 2, 5, 6 and 7, marginal integrity remained stable after the thermomechanical stress cycles, with the Cerafil inlays recording the best values: 89% perfect margins and 3% marginal gaps. In contrast, the experimental composite resins and the compomer underwent a significant (p < 0.05) increase in the proportion of marginal gaps and a significant (p < 0.05) reduction in the proportion of continuous margin. The results of this study show that neither Dyract compomer nor the glass-fiber-reinforced composite resins tested can be recommended for use in the occlusally stressed posterior region, whereas the other filling materials and methods were sufficiently stress resistant.
- 1 January 2000
- Vol. 2 (2) , 129-38
Marginal characteristics of different filling materials and filling methods with standardized cavity preparation.
The aim of the present study was to investigate the influence of different filling materials and methods on marginal integrity in Black Class I fillings. Standardized occlusal cavities were prepared in 80 extracted human molars. The preparations were filled with composite resin (1), with composite resin using the incremental technique (2), an experimental glass-fiber-reinforced (3) and polyester-reinforced (4) composite resin, a direct composite inlay (5), a ceramic insert (6), a Cerafil inlay (7), and with an experimental direct filling using Dyract AP compomer (8). Allocation of the teeth to the test groups was randomized; further processing was done on a blind basis. After the preparation of replicas, the teeth were subjected to a thermomechanical cycling process of 2,000 temperature cycles (5 degrees C/55 degrees C) and 50,000 stress cycles (50 N). This was followed by production of a second set of replicas and quantitative margin analysis by SEM (200X). A dye penetration test was then performed on the mesiodistal section. Groups 1, 2, 5, 6 and 7 displayed a good primary marginal quality, with the proportion of continuous margins reaching more than 85%. Significantly poorer results were recorded for the experimental glass-fiber-reinforced composite resins and Dyract compomer, where the proportion of perfect margins was only between 36% and 73%. In groups 1, 2, 5, 6 and 7, marginal integrity remained stable after the thermomechanical stress cycles, with the Cerafil inlays recording the best values: 89% perfect margins and 3% marginal gaps. In contrast, the experimental composite resins and the compomer underwent a significant (p < 0.05) increase in the proportion of marginal gaps and a significant (p < 0.05) reduction in the proportion of continuous margin. The results of this study show that neither Dyract compomer nor the glass-fiber-reinforced composite resins tested can be recommended for use in the occlusally stressed posterior region, whereas the other filling materials and methods were sufficiently stress resistant.