Roland Gilbert
Research Subjects
Roland Gilbert has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Jocelyn Jalbert
Institut de Recherche d’Hydro-Québec (IREQ)
3 shared publicationsPierre Tétreault
Institut de Recherche d’Hydro-Québec (IREQ)
3 shared publicationsBrigitte Morin
Institut de Recherche d’Hydro-Québec (IREQ)
2 shared publicationsDenise Lessard-Déziel
Institut de Recherche d’Hydro-Québec
1 shared publicationHong Phuong Nguyen
Institut de recherche d’Hydro-Québec (IREQ), 1800, boulevard Lionel-Boulet, Varennes, Que., Canada J3X 1S1
1 shared publicationJ. Jalbert
Institut de recherche d'Hydro-Québec (IREQ)
1 shared publication
Latest Publications
- 15 October 2008
- Published by Springer Nature in Cellulose
- Vol. 16 (2) , 327-338
Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 1: Standard wood kraft insulation
- 15 October 2008
- Published by Springer Nature in Cellulose
- Vol. 16 (2) , 327-338
Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 1: Standard wood kraft insulation
- 21 June 2007
- Published by Springer Nature in Cellulose
- Vol. 14 (4) , 295-309
Identification of a chemical indicator of the rupture of 1,4-β-glycosidic bonds of cellulose in an oil-impregnated insulating paper system
- 21 June 2007
- Published by Springer Nature in Cellulose
- Vol. 14 (4) , 295-309
Identification of a chemical indicator of the rupture of 1,4-β-glycosidic bonds of cellulose in an oil-impregnated insulating paper system
- 15 June 2004
- Published by Elsevier in Journal of Membrane Science
- Vol. 236 (1-2) , 153-161
Transport properties of a mixture of permanent gases and light hydrocarbons through the polytetrafluoroethylene capillary tubes of a GP-100 gas extractor
- 15 June 2004
- Published by Elsevier in Journal of Membrane Science
- Vol. 236 (1-2) , 153-161
Transport properties of a mixture of permanent gases and light hydrocarbons through the polytetrafluoroethylene capillary tubes of a GP-100 gas extractor
- 1 November 2002
- Published by Springer Nature in Chromatographia
- Vol. 56 (9-10) , 623-630
Comparative study of vapor-liquid phase equilibrium methods to measure partitioning coefficients of dissolved gases in hydrocarbon oils
- 1 November 2002
- Published by Springer Nature in Chromatographia
- Vol. 56 (9-10) , 623-630
Comparative study of vapor-liquid phase equilibrium methods to measure partitioning coefficients of dissolved gases in hydrocarbon oils
- 3 January 2001
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (3) , 520-526
Bias Assessment of Current Technologies Used for the Determination of Low Levels of Moisture in Mineral Oil Samples
The problem in the current debate on the accuracy of Karl Fischer (KF) titrations lies in the fact that coulometry is being compared to volumetry on mineral oil samples for which the true moisture content is unknown. To clarify this point, dehydrated oil samples equilibrated under known temperature and relative humidity conditions and equilibrated oil samples containing known amounts of added moisture were used to assess the accuracy of the determinations. In addition, the measurements were extended to other techniques given that it is unlikely that they would be affected by the same phenomenon causing the KF systematic errors. The samples sent to different laboratories were analyzed by headspace/capillary gas chromatography, gas-phase H2 sensor, oil-phase or gas-phase RH sensors, KF coulometric titration with direct or indirect injection, and KF volumetric titration using a standard or NIST modified procedure. The laboratory comparison showed that with the exception of 4 techniques out of 10 that were tested, the measurements gave results in the expected concentration range. Considering the exceptions, two techniques based on volumetric titration yielded results tainted with an important positive bias for both sample types. This bias, tentatively associated with the high iodine end point concentration used by these systems, was estimated at ∼22 ppm under the conditions applied by NIST. On the other hand, the two RH sensors showed a marked tendency to underestimate the value of the samples containing high moisture content. In this case, a loss of analyte through wall adsorption during the time required to achieve steady-state conditions in the measuring chamber seems to be at the origin of the negative biases.
- 3 January 2001
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (3) , 520-526
Bias Assessment of Current Technologies Used for the Determination of Low Levels of Moisture in Mineral Oil Samples
The problem in the current debate on the accuracy of Karl Fischer (KF) titrations lies in the fact that coulometry is being compared to volumetry on mineral oil samples for which the true moisture content is unknown. To clarify this point, dehydrated oil samples equilibrated under known temperature and relative humidity conditions and equilibrated oil samples containing known amounts of added moisture were used to assess the accuracy of the determinations. In addition, the measurements were extended to other techniques given that it is unlikely that they would be affected by the same phenomenon causing the KF systematic errors. The samples sent to different laboratories were analyzed by headspace/capillary gas chromatography, gas-phase H2 sensor, oil-phase or gas-phase RH sensors, KF coulometric titration with direct or indirect injection, and KF volumetric titration using a standard or NIST modified procedure. The laboratory comparison showed that with the exception of 4 techniques out of 10 that were tested, the measurements gave results in the expected concentration range. Considering the exceptions, two techniques based on volumetric titration yielded results tainted with an important positive bias for both sample types. This bias, tentatively associated with the high iodine end point concentration used by these systems, was estimated at ∼22 ppm under the conditions applied by NIST. On the other hand, the two RH sensors showed a marked tendency to underestimate the value of the samples containing high moisture content. In this case, a loss of analyte through wall adsorption during the time required to achieve steady-state conditions in the measuring chamber seems to be at the origin of the negative biases.