Takashi Nishimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takashi Nishimura has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Minoru Ono
Department of Cardiothoracic Surgery, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
27 shared publicationsShunei Kyo
東京都健康長寿医療センタ
24 shared publicationsMasahiko Ando
Department of Cardiothoracic Surgery, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
9 shared publications- Shunei Kyo
Department of Cardiac Surgery, Tokyo Metropolitan Geriatric Hospital
8 shared publications Motoyuki Hisagi
The University of Tokyo Hospital
7 shared publicationsEisuke Tatsumi
Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
6 shared publications
Latest Publications
- 1 January 2018
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 26 (2) , 362-367
Evaluation of radial stability of maglev blood pump for extracorporeal circulation driven to synchronize with heart beat
We have developed a novel blood pump with a magnetic levitated impeller to recover cardiac function. The blood pump can increase the coronary flow by varying rotational speed of the impeller in accordance with the heartbeat. In this work, radial displacements of the rotor were measured to evaluate passive stability with improved impeller which generated stronger axial attractive force. Levitation stability of the impellers in the pump with horizontally setting was compared to that vertically setting under the condition of continuous flow and pulsatile flow in a mock flow loop with normal saline. As a result, touchdown occurred with present impeller in the condition of vertical setting and pulsatile flow, whereas touchdown did not occur with improved impeller in any condition. In the future, hemolysis test, vibration test and durability test will be carried out with improved impeller. In consideration of safely, the levitation stability of improved impeller would be improved by changing size of the permanent magnets.
- 1 January 2018
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 26 (2) , 362-367
Evaluation of radial stability of maglev blood pump for extracorporeal circulation driven to synchronize with heart beat
We have developed a novel blood pump with a magnetic levitated impeller to recover cardiac function. The blood pump can increase the coronary flow by varying rotational speed of the impeller in accordance with the heartbeat. In this work, radial displacements of the rotor were measured to evaluate passive stability with improved impeller which generated stronger axial attractive force. Levitation stability of the impellers in the pump with horizontally setting was compared to that vertically setting under the condition of continuous flow and pulsatile flow in a mock flow loop with normal saline. As a result, touchdown occurred with present impeller in the condition of vertical setting and pulsatile flow, whereas touchdown did not occur with improved impeller in any condition. In the future, hemolysis test, vibration test and durability test will be carried out with improved impeller. In consideration of safely, the levitation stability of improved impeller would be improved by changing size of the permanent magnets.
- 12 July 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 104 (5) , 1488-1495
Novel Rotational Speed Modulation System Used With Venoarterial Extracorporeal Membrane Oxygenation
- 12 July 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 104 (5) , 1488-1495
Novel Rotational Speed Modulation System Used With Venoarterial Extracorporeal Membrane Oxygenation
- 1 September 2016
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 22 (9) , S158
Destination Therapy by Implantable LVAD: Agenda for Introduction of DT in Japan
- 1 September 2016
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 22 (9) , S158
Destination Therapy by Implantable LVAD: Agenda for Introduction of DT in Japan
- 19 July 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 20 (1) , 18-25
Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device
Continuous-flow left ventricular assist devices (LVADs) have improved the prognosis of end-stage heart failure. However, continuous-flow LVADs diminish pulsatility, which possibly result in bleeding, aortic insufficiency, and other adverse effects. We previously developed a novel control system for a continuous-flow LVAD (EVAHEART®; Sun Medical), and demonstrated that we could create sufficient pulsatility by increasing its rotational speed (RS) in the systolic phase (Pulsatile Mode) in the normal heart model. Here, we aimed to evaluate differences between systolic assist with advanced and delayed loads by shifting the timing of increased RS. We implanted EVAHEART in six goats (55.3 ± 4.3 kg) with normal hearts. We reduced their heart rates to P/dt max of aortic pressure, and energy-equivalent pulse pressure. During continuous-flow LVAD support, pulsatility can be controlled using a rotary pump. In particular, pulsatility can be shifted by delaying increased RS.
- 19 July 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 20 (1) , 18-25
Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device
Continuous-flow left ventricular assist devices (LVADs) have improved the prognosis of end-stage heart failure. However, continuous-flow LVADs diminish pulsatility, which possibly result in bleeding, aortic insufficiency, and other adverse effects. We previously developed a novel control system for a continuous-flow LVAD (EVAHEART®; Sun Medical), and demonstrated that we could create sufficient pulsatility by increasing its rotational speed (RS) in the systolic phase (Pulsatile Mode) in the normal heart model. Here, we aimed to evaluate differences between systolic assist with advanced and delayed loads by shifting the timing of increased RS. We implanted EVAHEART in six goats (55.3 ± 4.3 kg) with normal hearts. We reduced their heart rates to P/dt max of aortic pressure, and energy-equivalent pulse pressure. During continuous-flow LVAD support, pulsatility can be controlled using a rotary pump. In particular, pulsatility can be shifted by delaying increased RS.
- 20 June 2016
- p. 624-8
[Painless external counterpulsation circulatory assist system (Compact CP)].
- 14 May 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 19 (4) , 315-321
Shifting the pulsatility by increasing the change in rotational speed for a rotary LVAD using a native heart load control system
- 14 May 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 19 (4) , 315-321
Shifting the pulsatility by increasing the change in rotational speed for a rotary LVAD using a native heart load control system
- Open Access
- 1 January 2016
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 24 (3) , 216-221
Levitation Stability of Passive Stability Axes of Heart Beat Synchronous Maglev Blood Pump
- 1 January 2016
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 24 (3) , 216-221
Open AccessLevitation Stability of Passive Stability Axes of Heart Beat Synchronous Maglev Blood Pump
- 22 June 2014
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 17 (3) , 211-219
Current status of extracorporeal ventricular assist devices in Japan
Extracorporeal VADs are less expensive, their prices reimbursable by the health insurance being about one-sixth of those of implantable VADs in Japan. However, a disadvantage is that, in Japan, their use is restricted to hospitals, necessitating prolonged hospitalization, reducing the patients’ quality of life. According to the Japanese registry for Mechanically Assisted Circulatory Support, the survival rate does not differ significantly between patients with extracorporeal and implantable VADs. As in Europe and North America, extracorporeal VADs in Japan are commonly used as Bridge to Decision or Bridge to Recovery. Extracorporeal VADs are switched to implantable VADs as a Bridge-to-Bridge strategy after stabilization or when cardiac function recovery fails. They are also used as right ventricular assist devices (RVADs) in patients with right heart failure. A special characteristic of extracorporeal VADs in Japan is their frequent use as a Bridge to Candidacy. In Japan, indications for implantable VADs are restricted to patients registered for heart transplantation. Therefore, in patients who cannot be registered for transplantation because of transient renal dysfunction, etc., due to heart failure, extracorporeal VADs are used first, and then replaced by implantable VADs after transplant registry is done. Here, we describe the current status of extracorporeal VADs in Japan, focusing on the environmental backgrounds, along with a review of the relevant literature.
- 22 June 2014
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 17 (3) , 211-219
Current status of extracorporeal ventricular assist devices in Japan
Extracorporeal VADs are less expensive, their prices reimbursable by the health insurance being about one-sixth of those of implantable VADs in Japan. However, a disadvantage is that, in Japan, their use is restricted to hospitals, necessitating prolonged hospitalization, reducing the patients’ quality of life. According to the Japanese registry for Mechanically Assisted Circulatory Support, the survival rate does not differ significantly between patients with extracorporeal and implantable VADs. As in Europe and North America, extracorporeal VADs in Japan are commonly used as Bridge to Decision or Bridge to Recovery. Extracorporeal VADs are switched to implantable VADs as a Bridge-to-Bridge strategy after stabilization or when cardiac function recovery fails. They are also used as right ventricular assist devices (RVADs) in patients with right heart failure. A special characteristic of extracorporeal VADs in Japan is their frequent use as a Bridge to Candidacy. In Japan, indications for implantable VADs are restricted to patients registered for heart transplantation. Therefore, in patients who cannot be registered for transplantation because of transient renal dysfunction, etc., due to heart failure, extracorporeal VADs are used first, and then replaced by implantable VADs after transplant registry is done. Here, we describe the current status of extracorporeal VADs in Japan, focusing on the environmental backgrounds, along with a review of the relevant literature.
- 7 June 2014
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 17 (3) , 278-280
Novel external counterpulsation system, compact counterpulsation, was effective to treat severe ischemic heart failure: a case report
Compact counterpulsation (CP) is a novel external counterpulsation system. The preoperative clinical utility of compact CP therapy in patients has not been established. In the present report, we describe a case wherein compact CP therapy was successfully used to treat severe ischemic heart failure. A 70-year-old man was diagnosed with ischemic heart disease and mitral valve regurgitation at 61 years of age. Therefore, he underwent coronary artery bypass and mitral valve plasty. The patient’s condition started to gradually deteriorate at 68 years of age, and he became progressively dependent on catecholamine support. Mitral valve regurgitation recurred, which caused worsening of heart function. Before a mitral valve replacement, the patient had been treated with compact CP therapy to improve heart function and general condition. The patient’s clinical condition improved with compact CP therapy after only ten sessions; in addition, he could be weaned off catecholamine support. No adverse effects were observed, and therefore, he could complete the CP therapy as an outpatient. Mitral valve replacement was performed after a total of 44 sessions. The patient had an uneventful postoperative course and was discharged on the 18th postoperative day. Compact CP therapy was thus performed on our patient without any discomfort and appears to be an effective treatment for patients with severe ischemic heart failure.
- 7 June 2014
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 17 (3) , 278-280
Novel external counterpulsation system, compact counterpulsation, was effective to treat severe ischemic heart failure: a case report
Compact counterpulsation (CP) is a novel external counterpulsation system. The preoperative clinical utility of compact CP therapy in patients has not been established. In the present report, we describe a case wherein compact CP therapy was successfully used to treat severe ischemic heart failure. A 70-year-old man was diagnosed with ischemic heart disease and mitral valve regurgitation at 61 years of age. Therefore, he underwent coronary artery bypass and mitral valve plasty. The patient’s condition started to gradually deteriorate at 68 years of age, and he became progressively dependent on catecholamine support. Mitral valve regurgitation recurred, which caused worsening of heart function. Before a mitral valve replacement, the patient had been treated with compact CP therapy to improve heart function and general condition. The patient’s clinical condition improved with compact CP therapy after only ten sessions; in addition, he could be weaned off catecholamine support. No adverse effects were observed, and therefore, he could complete the CP therapy as an outpatient. Mitral valve replacement was performed after a total of 44 sessions. The patient had an uneventful postoperative course and was discharged on the 18th postoperative day. Compact CP therapy was thus performed on our patient without any discomfort and appears to be an effective treatment for patients with severe ischemic heart failure.
- 1 June 2014
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 17 (3) , 288-290
Sternalock plating system for elderly post-sternotomy patients
- 1 June 2014
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 17 (3) , 288-290
Sternalock plating system for elderly post-sternotomy patients