TFTakashi Fujikado

Takashi Fujikado

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takashi Fujikado has a total of 186 co-authors. Here are the top co-authors by number of shared publications:

  • Takeshi Morimoto

    Department of Integrative Physiology, Graduate School of Medicine, Osaka University, Suita, Japan

    29 shared publications
  • Hiroyuki Kanda

    Department of Applied Visual Science, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan

    22 shared publications
  • Takao Endo

    Affiliation Department of Ophthalmology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan

    17 shared publications
  • Yasuo Tano

    Department of Ophthalmology, Osaka University, Graduate School of Medicine, Osaka, Japan

    17 shared publications
  • Sanae Asonuma

    Department of Ophthalmology, Osaka University Medical School, Osaka, Japan

    16 shared publications
  • Yoko Hirohara

    Affiliations Department of Applied Visual Science, Osaka University Graduate School of Medicine, Suita, Osaka, Japan, Special Research Promotion Group, Osaka University Graduate School of Frontier Biosciences, Suita, Osaka, Japan, Topcon Corporation, Tokyo, Japan

    14 shared publications

Latest Publications

  • Open Access

    Spatial Resolution of Suprachoroidal–Transretinal Stimulation Estimated by Recording Single-Unit Activity From the Cat Lateral Geniculate Nucleus

    by Tomomitsu Miyoshi, Takeshi Morimoto, Hajime Sawai, Takashi Fujikado

    Retinal prostheses are devices used to restore visual sensation in patients suffering from photoreceptor degeneration, such as retinitis pigmentosa. Suprachoroidal–transretinal stimulation (STS) is a prosthesis with retinal electrodes located in the sclera. STS has the advantage that it is safer than epiretinal or subretinal prostheses, as the implant is not directly attached to the retinal tissue. We have previously reported feasibility of STS with animal experiments and clinical trials. However, functional evaluation with neurophysiological experiments is still largely missing. To estimate the spatial resolution of STS, single-unit activities in response to STS were recorded from relay cells in the dorsal lateral geniculate nucleus of cats, and the response probability of the units was analyzed in relation to the distance between the stimulus location and the receptive field of each recorded unit. A platinum electrode was attached to the sclera after lamellar resection, and the return electrode was placed in the vitreous. The stimulating current, which ranged from 50 to 500 μA, was applied between these electrodes, and the probability of spike responses occurring just after retinal stimulation was measured. The distance at half-maximum of response was determined from the collected response probabilities as a function of stimulus intensity for all units characterized by their distances from the receptive field center to the stimulation point. As the stimulation became weaker, this distance decreased to 1.8° at 150 and 100 μA. As another estimation, the radius of 25% response probability was 1.4° at 100 μA. The diameter of the stimulated cat retinal area, 3.6° or 2.8°, corresponds to human visual acuity of 0.005 or 0.007, or finger counting. Considering the lower hazard to the retina of STS and its potentially large visual field coverage, STS is an attractive method for retinal prosthetic device development.


  • Optimizing correction of coma aberration in keratoconus with a novel soft contact lens

    by Asaki Suzaki, Shizuka Koh, Naoyuki Maeda, Sanae Asonuma, Jacinto Santodomingo-Rubido, Yoshinori Oie, Takeshi Soma, Takashi Fujikado, Kohji Nishida


  • Open Access

    Simultaneous Measurement of Objective and Subjective Accommodation in Response to Step Stimulation

    by Masakazu Hirota, Takeshi Morimoto, Tomomitsu Miyoshi, Takashi Fujikado

    Purpose: This study aimed to evaluate differences in objective and subjective accommodation dynamically and simultaneously. Methods: Thirty-four pre-presbyopic healthy volunteers (mean age ± SD, 41.0 ± 3.2 years) participated in this study. Initially, the reaction time for detecting a change in the target was measured at near. Dynamic accommodation was then monocularly recorded using an open-view Shack–Hartmann aberrometer and compared with the amplitude and velocity of subjective accommodation. Results: The objective amplitude of accommodation (0.97 ± 0.32 diopter [D]) was significantly greater than the subjective amplitude of accommodation (0.62 ± 0.43 D; P < 0.001). The accommodative velocity was significantly faster for the “before the accommodation” response time (0.47 ± 0.38 D/s) than the “after the accommodation” response time (0.21 ± 0.22 D/s; P = 0.007). Conclusions: The human eye under the monocular condition quickly adjusts to the focal plane to clearly archive the nearby object, and the focal plane thereafter is slowly and accurately adjusted to the visual target after visual recognition.


  • Top Cited Papers

    An update on retinal prostheses

    by Lauren N. Ayton, Nick Barnes, Gislin Dagnelie, Takashi Fujikado, Georges Goetz, Ralf Hornig, Bryan W. Jones, Mahiul M.K. Muqit, Daniel L. Rathbun, Katarina Stingl, et al.


  • Open Access

    Objective evaluation of visual fatigue in patients with intermittent exotropia

    by Masakazu Hirota, Kozue Yada, Takeshi Morimoto, Takao Endo, Tomomitsu Miyoshi, Suguru Miyagawa, Yoko Hirohara, Tatsuo Yamaguchi, Makoto Saika, Takashi Fujikado

    The purpose of this study was to evaluate the degree of visual fatigue in patients with intermittent exotropia (IXT) using the binocular fusion maintenance (BFM) test. Fourteen patients with IXT (32.1 ± 16.4 years) and 15 age-matched healthy volunteers (31.2 ± 9.3 years) participated in the study. BFM was assessed by measuring the transmittance of liquid crystals placed in front of the subject's nondominant eye at the instance when binocular fusion was broken and vergence eye movement was induced. A questionnaire on subjective symptoms was administered to the subjects before and after the visual task. The visual task consisted of a reciprocal movement between 67 and 40 cm. The change [post–pre] of BFM was significantly lower in the IXT group (−0.185 ± 0.187) than in the control group (−0.030 ± 0.070) (P = 0.010). The change of total subjective eye symptom score was significantly greater in the IXT group (2.28 ± 1.43) than in the control group (0.93 ± 1.27) (P = 0.018). The reduction in BFM rate with increasing total subjective eye symptom score was significantly greater in the IXT group (−0.106 ± 0.017) than in the control group (−0.030 ± 0.013) (P = 0.006). The present findings objectively showed that patients with IXT are at a greater risk of visual fatigue in comparison with healthy individuals.


  • Binocular Coordination during Smartphone Reading in Esophoric Patients

    by Masakazu Hirota, Takeshi Morimoto, Tomomitsu Miyoshi, Takashi Fujikado

    Purpose: To evaluate binocular coordination using video-oculography (VOG) during smartphone reading in patients with esophoria (EP) compared with control subjects. Patients and methods: Ten young and adult patients with EP (25.3 ± 7.3 years) and seven orthophoric or small-angle exophoric control subjects (25.7 ± 4.8 years) were examined. Eye movements were recorded during smartphone reading at 20, 30, and 50 cm using VOG. Differences in the horizontal fixation disparity at each distance between and within the groups were analyzed. Results: Horizontal esodeviation at 20 cm in the EP group (1.23° ± 2.00°) was significantly greater than that at 30 cm (−0.39° ± 0.73°; P = .027) and was significantly greater than horizontal exodeviation at 20 cm in the control group (−0.21° ± 0.17°; P < .001). Conclusion: The current findings suggest that the horizontal fixation disparities in the patients with EP deviate to eso-direction during smartphone use.


  • The influence of visual field position induced by a retinal prosthesis simulator on mobility

    by Takao Endo, Kenta Hozumi, Masakazu Hirota, Hiroyuki Kanda, Takeshi Morimoto, Kohji Nishida, Takashi Fujikado

    Purpose Our aim is to develop a new generation of suprachoroidal–transretinal stimulation (STS) retinal prosthesis using a dual-stimulating electrode array to enlarge the visual field. In the present study, we aimed to examine how position and size of the visual field—created by a retinal prosthesis simulator—influenced mobility. Methods Twelve healthy subjects wore retinal prosthesis simulators. Images captured by a web camera attached to a head-mounted display (HMD) were processed by a computer and displayed on the HMD. Three types of artificial visual fields—designed to imitate phosphenes—obtained by a single (5 × 5 electrodes; visual angle, 15°) or dual (5 × 5 electrodes ×2; visual angle, 30°) electrode array were created. Visual field (VF)1 is an inferior visual field, which corresponds to a dual-electrode array implanted in the superior hemisphere. VF2 is a superior visual field, which corresponds to a single-electrode array implanted in the inferior hemisphere. VF3 is a superior visual field, which corresponds to a dual-electrode array implanted in the inferior hemisphere. In each type of artificial visual field, a natural circular visual field (visual angle, 5°) which imitated the vision of patients with advanced retinitis pigmentosa existed at the center. Subjects were instructed to walk along a black carpet (6 m long × 2.2 m wide) without stepping on attached white circular obstacles. Each obstacle was 20 cm in diameter, and obstacles were installed at 40-cm intervals. We measured the number of footsteps on the obstacles, the time taken to complete the obstacle course, and the extent of head movement to scan the area (head-scanning). We then compared the results recorded from these 3 types of artificial visual field. Results The number of footsteps on obstacles was lowest in VF3 (One-way ANOVA; P = 0.028, Fisher’s LSD; VF 1 versus 3 P = 0.039, 2 versus 3 P = 0.012). No significant difference was observed for the time to complete the obstacle course or the extent of head movement between the 3 visual fields. Conclusion The superior and wide visual field (VF3) obtained by the retinal prosthesis simulator resulted in better mobility performance than the other visual fields.


  • Comparison of visual fatigue caused by head-mounted display for virtual reality and two-dimensional display using objective and subjective evaluation

    by Masakazu Hirota, Hiroyuki Kanda, Takao Endo, Tomomitsu Miyoshi, Suguru Miyagawa, Yoko Hirohara, Tatsuo Yamaguchi, Makoto Saika, Takeshi Morimoto, Takashi Fujikado

    This study aimed to evaluate objective and subjective visual fatigue experienced before and after performing a visual task while using a head-mounted display for virtual reality (VR-HMD) and two-dimensional (2D) display. Binocular fusion maintenance (BFM) was measured using a binocular open-view Shack–Hartmann wavefront aberrometer equipped with liquid crystal shutters. Twelve healthy subjects performed the BFM test and completed a questionnaire regarding subjective symptoms before and after performing a visual task that induces low visually induced motion sickness (VIMS). BFM (p = .87) and total subjective eye symptom scores (p = .38) were not significantly different between both groups, although these values were significantly lower after the visual task than before the task within both groups (p < .05). These findings suggest that visual fatigue after using a VR-HMD is not significantly different from that after using a 2D display in the presence of low-VIMS VR content. Practitioner summary : Objective and subjective evaluation of visual fatigue were not significantly different with the use of a head-mounted display for virtual reality (VR-HMD) and two-dimensional display. These results should be valuable not only to engineers developing VR content but also to researchers involved in the evaluation of visual fatigue using VR-HMD. Abbreviations: VR: virtual reality; VR-HMD: head-mounted display for virtual reality; BFM: binocular fusion maintenance; BWFA: binocular open-view Shack–Hartmann wavefront aberrometer


  • Open Access

    Binocular coordination and reading performance during smartphone reading in intermittent exotropia

    by Masakazu Hirota, Hiroyuki Kanda, Takao Endo, Takeshi Morimoto, Tomomitsu Miyoshi, Takashi Fujikado

    Purpose: This study aimed to evaluate binocular coordination using video-oculography during smartphone reading in patients with intermittent exotropia compared to individuals with normal vision. Patients and methods: Eleven youth and adult patients with intermittent exotropia (21.9±9.3 years) and 15 control subjects (26.6±4.3 years) were examined. Eye movements were recorded during smartphone reading at 50, 30, and 20 cm using video-oculography. The loss of binocular coordination was tentatively defined as a horizontal disparity greater than 2°. The proportion of monocular viewing was the percentage of time for which binocularity was lost during smartphone reading. The proportion of monocular viewing, the reading speed, and the correlation between proportion of monocular viewing and reading speed were analyzed. Results: The proportion of monocular viewing during smartphone reading was significantly higher in the intermittent exotropia group than in the control group (PPP Conclusion: A significant increase in the proportion of monocular viewing in the intermittent exotropia group suggests that an appropriate viewing distance should be advised so that users can maintain binocular coordination when viewing a smartphone.