Brian M. Tissue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Brian M. Tissue has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Ronald L. Earp
Virginia Polytechnic Institute and State University
2 shared publicationsBrian E. Trice
Department of Chemistry , Virginia Polytechnic Institute and State University , Blacksburg, Virginia, USA
1 shared publicationChing-Wan Yip
Wake Forest University
1 shared publicationJohn R. Morris
Virginia Polytechnic Institute and State University
1 shared publicationR. Craig Watson
Department of Chemistry, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061-0212, USA
1 shared publicationSteve W. Hunsucker
Department of Chemistry, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061-0212, USA
1 shared publication
Latest Publications
- 1 August 2009
- Published by Springer Nature in Journal of Materials Science
- Vol. 44 (16) , 4286-4295
Control of morphology in inert-gas condensation of metal oxide nanoparticles
- 1 August 2009
- Published by Springer Nature in Journal of Materials Science
- Vol. 44 (16) , 4286-4295
Control of morphology in inert-gas condensation of metal oxide nanoparticles
- 27 March 2007
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 40 (2) , 333-348
Nonlinear Luminescence Quenching in Eu2O3
We report a laser spectroscopic investigation of saturation effects in the spectra and dynamics of Eu2O3. The saturation effects occur at high laser intensity and appear as dips in the center of the fluorescence excitation lines and as a shortening of the 5D0 excited‐state decay curve. The saturation effects are observed in nanoparticles, micrometer‐sized particles, and a fused crystal of monoclinic‐phase Eu2O3 and in micrometer‐sized particles of cubic‐phase Eu2O3. We attribute the mechanism of the nonlinear luminescence quenching to upconversion by energy transfer.
- 27 March 2007
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 40 (2) , 333-348
Nonlinear Luminescence Quenching in Eu2O3
We report a laser spectroscopic investigation of saturation effects in the spectra and dynamics of Eu2O3. The saturation effects occur at high laser intensity and appear as dips in the center of the fluorescence excitation lines and as a shortening of the 5D0 excited‐state decay curve. The saturation effects are observed in nanoparticles, micrometer‐sized particles, and a fused crystal of monoclinic‐phase Eu2O3 and in micrometer‐sized particles of cubic‐phase Eu2O3. We attribute the mechanism of the nonlinear luminescence quenching to upconversion by energy transfer.
- 13 July 2001
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (15) , 1334-1340
Characterization of inorganic coordination complexes by matrix‐assisted laser desorption/ionization mass spectrometry
We report the direct laser desorption/ionization (LDI) and matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometric (MALDI‐TOFMS) analysis of four inorganic coordination complexes: monometallic [Ir(dpp) 2 Cl 2 ](PF 6 ), homonuclear trimetallic {[(bpy) 2 Ru(dpp)] 2 RuCl 2 }‐ (PF 6 ) 4 , and heteronuclear [(tpy)Ru(tpp)Ru(tpp)RhCl 3 ](PF 6 ) 4 and {[(bpy) 2 Ru(dpp)] 2 IrCl 2 }(PF 6 ) 5 (dpp = 2,3‐ bis ‐(2′‐pyridyl)pyrazine, bpy = 2,2′‐bipyridine, tpy = 2,2′,6′,2″‐terpyradine, tpp = 2,3,5,6,‐ tetrakis ‐(2′‐pyridyl)pyrazine). Spectral intensities and fragmentation patterns are compared and evaluated for instrument parameters, matrix selection, and matrix‐to‐analyte ratio. Direct LDI and MALDI mass spectra of the monometallic complex showed the same ion peaks and differed only in the relative peak intensities. Direct LDI of the trimetallic complexes produced only low‐mass fragments containing one metal at most. MALDI spectra of the trimetallic complexes exhibited little fragmentation in the high‐mass region (>1500 Da) and less fragmentation in the low‐mass region compared to direct LDI. Significant fragments of the molecules were detected and identified, including ligand fragments, intermediate‐mass fragments such as [Ru(tpy)] + , and molecular ions with varying degrees of PF 6 − loss ([M − n(PF 6 )] + , where n = 1–3). A correlation exists between the solution‐phase electrochemistry and the observed [M − n(PF 6 )] + series of peaks for the trimetallic complexes. Proper matrix selection for MALDI analysis was vital, as was an appropriate matrix‐to‐analyte ratio. The results demonstrate the applicability of MALDI‐TOFMS for the structural characterization of labile inorganic coordination complexes. Copyright © 2001 John Wiley & Sons, Ltd.
- 13 July 2001
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (15) , 1334-1340
Characterization of inorganic coordination complexes by matrix‐assisted laser desorption/ionization mass spectrometry
We report the direct laser desorption/ionization (LDI) and matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometric (MALDI‐TOFMS) analysis of four inorganic coordination complexes: monometallic [Ir(dpp) 2 Cl 2 ](PF 6 ), homonuclear trimetallic {[(bpy) 2 Ru(dpp)] 2 RuCl 2 }‐ (PF 6 ) 4 , and heteronuclear [(tpy)Ru(tpp)Ru(tpp)RhCl 3 ](PF 6 ) 4 and {[(bpy) 2 Ru(dpp)] 2 IrCl 2 }(PF 6 ) 5 (dpp = 2,3‐ bis ‐(2′‐pyridyl)pyrazine, bpy = 2,2′‐bipyridine, tpy = 2,2′,6′,2″‐terpyradine, tpp = 2,3,5,6,‐ tetrakis ‐(2′‐pyridyl)pyrazine). Spectral intensities and fragmentation patterns are compared and evaluated for instrument parameters, matrix selection, and matrix‐to‐analyte ratio. Direct LDI and MALDI mass spectra of the monometallic complex showed the same ion peaks and differed only in the relative peak intensities. Direct LDI of the trimetallic complexes produced only low‐mass fragments containing one metal at most. MALDI spectra of the trimetallic complexes exhibited little fragmentation in the high‐mass region (>1500 Da) and less fragmentation in the low‐mass region compared to direct LDI. Significant fragments of the molecules were detected and identified, including ligand fragments, intermediate‐mass fragments such as [Ru(tpy)] + , and molecular ions with varying degrees of PF 6 − loss ([M − n(PF 6 )] + , where n = 1–3). A correlation exists between the solution‐phase electrochemistry and the observed [M − n(PF 6 )] + series of peaks for the trimetallic complexes. Proper matrix selection for MALDI analysis was vital, as was an appropriate matrix‐to‐analyte ratio. The results demonstrate the applicability of MALDI‐TOFMS for the structural characterization of labile inorganic coordination complexes. Copyright © 2001 John Wiley & Sons, Ltd.
- 31 October 1997
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 16 (9) , 490-495
Overview of interactive programming methods for the world-wide web
- 31 October 1997
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 16 (9) , 490-495
Overview of interactive programming methods for the world-wide web
- 1 December 1996
- Published by University of California Press in The Chemical Educator
- Vol. 1 (5) , 1-14
A PERL Script to Generate HTML Pages Containing Multiple-Choice Questions
- 1 December 1996
- Published by University of California Press in The Chemical Educator
- Vol. 1 (5) , 1-14
A PERL Script to Generate HTML Pages Containing Multiple-Choice Questions
- 1 March 1996
- Published by University of California Press in The Chemical Educator
- Vol. 1 (1) , 1-13
Design and Student Use of World Wide Web-Based Prelab Exercises
This paper describes the design, use, and evaluation of World Wide Web-based prelab exercises in senior-level Instrumental Analysis. On-time completion of the prelab assignments was 75%, but use of other on-line resources such as a question-and-answer page was minimal. A midsemester assessment of the prelabs found that the multiple-choice questions were better for increasing conceptual understanding, rather than preparing the students for the actual lab work.
- 1 March 1996
- Published by University of California Press in The Chemical Educator
- Vol. 1 (1) , 1-13
Design and Student Use of World Wide Web-Based Prelab Exercises
This paper describes the design, use, and evaluation of World Wide Web-based prelab exercises in senior-level Instrumental Analysis. On-time completion of the prelab assignments was 75%, but use of other on-line resources such as a question-and-answer page was minimal. A midsemester assessment of the prelabs found that the multiple-choice questions were better for increasing conceptual understanding, rather than preparing the students for the actual lab work.
- 31 October 1995
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 14 (9) , 426-430
Distributing and retrieving chemical information using the World-Wide Web
- 31 October 1995
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 14 (9) , 426-430
Distributing and retrieving chemical information using the World-Wide Web