Akikazu Shinya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Akikazu Shinya has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Akiyoshi Shinya
Department of Crown and Bridge, The Nippon Dental University School of Life Dentistry at Tokyo, 1-9-20 Fujimi, Chiyoda-Ku, Tokyo, 102-8159, Japan.
9 shared publications Daiichiro Yokoyama
Department of Crown and Bridge, The Nippon Dental University School of Life Dentistry at Tokyo, Tokyo, Japan
6 shared publicationsHarunori Gomi
Department of Crown and Bridge, School of Life Dentistry at Tokyo, The Nippon Dental University
6 shared publications- Pekka Kalevi Vallittu
Department of Biomaterials Science, Institute of Dentistry, University of Turku, Turku, Finland
5 shared publications Akiyoshi Shinya
Department of Crown and Bridge, School of Life Dentistry at Tokyo, The Nippon Dental University
4 shared publicationsLippo V J Lassila
3 shared publications
Latest Publications
- Open Access
- 1 January 2017
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 36 (4) , 402-407
The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses
The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.
- 1 January 2017
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 36 (4) , 402-407
Open AccessThe accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses
The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.
- 11 December 2015
- Published by Springer Nature in Odontology
- Vol. 104 (3) , 291-297
Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites
This study evaluated characteristics of light transmission, degree of monomer conversion and surface microhardness of bulk fill, conventional and fiber-reinforced resin based composites (RBCs) through different incremental thicknesses of resin composite. Working hypotheses was that there are differences in transmission of blue light through RBCs of different kinds and that the thickness of the increments influence the degree of monomer conversion of RBCs. Six bulk fill, three conventional nanohybrid, one short fiber reinforced and one flowable RBCs were evaluated. For each material, four different incremental thicknesses (1, 2, 3 and 4 mm) were considered (n = 5). The specimens were prepared in cylindrical Teflon molds that are open at the top and the bottom sides and cured for 40 s by applying the curing unit. After curing process, the specimens were ground with a silicon carbide paper with a grit size of 1200 and 4000, and then stored dry at 37 °C for 24 h. Light transmission, degree of monomer conversion, surface microhardness were measured and data were analyzed using ANOVA (p = 0.05). There were differences in light transmission of resin composites of various types and brands. Low-viscous bulk fill and short fiber-reinforced RBCs presented higher light transmission compared to resin composites of higher viscosity. Reduced light transmission and lower surface microhardness and DC % at bottom side of the specimen suggests that more attention needs to be paid to ensure proper curing of the resin composite in deep cavities.
- 11 December 2015
- Published by Springer Nature in Odontology
- Vol. 104 (3) , 291-297
Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites
This study evaluated characteristics of light transmission, degree of monomer conversion and surface microhardness of bulk fill, conventional and fiber-reinforced resin based composites (RBCs) through different incremental thicknesses of resin composite. Working hypotheses was that there are differences in transmission of blue light through RBCs of different kinds and that the thickness of the increments influence the degree of monomer conversion of RBCs. Six bulk fill, three conventional nanohybrid, one short fiber reinforced and one flowable RBCs were evaluated. For each material, four different incremental thicknesses (1, 2, 3 and 4 mm) were considered (n = 5). The specimens were prepared in cylindrical Teflon molds that are open at the top and the bottom sides and cured for 40 s by applying the curing unit. After curing process, the specimens were ground with a silicon carbide paper with a grit size of 1200 and 4000, and then stored dry at 37 °C for 24 h. Light transmission, degree of monomer conversion, surface microhardness were measured and data were analyzed using ANOVA (p = 0.05). There were differences in light transmission of resin composites of various types and brands. Low-viscous bulk fill and short fiber-reinforced RBCs presented higher light transmission compared to resin composites of higher viscosity. Reduced light transmission and lower surface microhardness and DC % at bottom side of the specimen suggests that more attention needs to be paid to ensure proper curing of the resin composite in deep cavities.
- 9 September 2014
- Published by Springer Nature in Odontology
- Vol. 103 (3) , 333-338
Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study
The purpose of this in vitro study was to compare the stress distribution and natural frequency of different shape and thickness retainer designs for maxillary posterior resin-bonded prostheses using finite element (FE) method. A 3D FE model of a three unit posterior resin-bonded prosthesis analysis model was generated. Three different shaped retainer designs, viz. C-shaped (three axial surface wraparounds), D-shaped (three axial surface wraparounds with central groove) and O-shaped (360° wraparounds), and three different thicknesses, viz., 0.4, 0.8, and 1.2 mm, resin-bonded prostheses were used in this study. The resin-bonded prosthesis analysis model was imported into an FE analysis software (ANSYS 10.0, ANSYS, USA) and attribution of material properties. The nodes at the bottom surface of the roots were assigned fixed zero displacement in the three spatial dimensions. A simulated angle of 45° loading of a 100 N force was applied to the node of the pontic lingual cusp surface. The stress distributions and corresponding natural frequencies were analyzed and resolved. The C-shaped retainer for 0.4 mm thickness recorded the greatest von Mises stresses of 71.4 MPa for all three groups. C-shaped, D-shaped and O-shaped retainer presented natural frequencies 3,988, 7,754, and 10,494 Hz, respectively. D-shaped retainer and O-shaped retainer increased natural frequencies and structural rigidity over the traditional C-shaped retainer. The maximum von Mises stresses values of the remaining tooth and prosthesis decreased with greater retainer thickness. D-shaped retainer and O-shaped retainer increased natural frequencies and structural rigidity over the traditional C-shaped retainer.
- 9 September 2014
- Published by Springer Nature in Odontology
- Vol. 103 (3) , 333-338
Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study
The purpose of this in vitro study was to compare the stress distribution and natural frequency of different shape and thickness retainer designs for maxillary posterior resin-bonded prostheses using finite element (FE) method. A 3D FE model of a three unit posterior resin-bonded prosthesis analysis model was generated. Three different shaped retainer designs, viz. C-shaped (three axial surface wraparounds), D-shaped (three axial surface wraparounds with central groove) and O-shaped (360° wraparounds), and three different thicknesses, viz., 0.4, 0.8, and 1.2 mm, resin-bonded prostheses were used in this study. The resin-bonded prosthesis analysis model was imported into an FE analysis software (ANSYS 10.0, ANSYS, USA) and attribution of material properties. The nodes at the bottom surface of the roots were assigned fixed zero displacement in the three spatial dimensions. A simulated angle of 45° loading of a 100 N force was applied to the node of the pontic lingual cusp surface. The stress distributions and corresponding natural frequencies were analyzed and resolved. The C-shaped retainer for 0.4 mm thickness recorded the greatest von Mises stresses of 71.4 MPa for all three groups. C-shaped, D-shaped and O-shaped retainer presented natural frequencies 3,988, 7,754, and 10,494 Hz, respectively. D-shaped retainer and O-shaped retainer increased natural frequencies and structural rigidity over the traditional C-shaped retainer. The maximum von Mises stresses values of the remaining tooth and prosthesis decreased with greater retainer thickness. D-shaped retainer and O-shaped retainer increased natural frequencies and structural rigidity over the traditional C-shaped retainer.
- Open Access
- 1 January 2013
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 32 (3) , 476-483
Effects of rotating fatigue on the mechanical properties of microhybrid and nanofiller-containing composites
The objective of this study was to assess and compare the flexural strength and Vickers hardness of five nanofiller-containing composites (Filtek Supreme XT, Gradia Forte, Luna-Wing, GNH400N, GCUC) against five microhybrid composites (Meta Color Prime Art, Solidex, Estenia C&B, Ceramage, Clearfil Majesty) before and after rotating fatigue test (RFT). For each resin composite, 16 rectangular beam specimens (2 mm×2 mm×25 mm) were prepared and half of which were subjected to 1×104 cycles in RFT. Flexural strength was determined using a three-point bending test. Vickers hardness measurements were carried out on specimens which failed after the three-point bending test. When under the influence of rotating fatigue, the flexural strength of all composites was affected by multiple factors. In contrast, rotating fatigue had no significant influence on the Vickers hardness of both microhybrid and nanofiller-containing composites.
- 1 January 2013
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 32 (3) , 476-483
Open AccessEffects of rotating fatigue on the mechanical properties of microhybrid and nanofiller-containing composites
The objective of this study was to assess and compare the flexural strength and Vickers hardness of five nanofiller-containing composites (Filtek Supreme XT, Gradia Forte, Luna-Wing, GNH400N, GCUC) against five microhybrid composites (Meta Color Prime Art, Solidex, Estenia C&B, Ceramage, Clearfil Majesty) before and after rotating fatigue test (RFT). For each resin composite, 16 rectangular beam specimens (2 mm×2 mm×25 mm) were prepared and half of which were subjected to 1×104 cycles in RFT. Flexural strength was determined using a three-point bending test. Vickers hardness measurements were carried out on specimens which failed after the three-point bending test. When under the influence of rotating fatigue, the flexural strength of all composites was affected by multiple factors. In contrast, rotating fatigue had no significant influence on the Vickers hardness of both microhybrid and nanofiller-containing composites.
- 13 September 2012
- Published by Wiley in Journal of Investigative and Clinical Dentistry
- Vol. 3 (4) , 291-297
Finite element analysis to compare stress distribution of gold alloy, lithium-disilicate reinforced glass ceramic and zirconia based fixed partial denture
Clinical data indicate that veneer chipping of zirconia core is more likely than with ceramic‐fused‐to‐metal structures. The purposes of this simulation study were to: (a) use two‐dimensional finite element modeling to simulate stresses at the interface of three‐unit posterior fixed partial dentures (FPDs) made with three different core materials; and (b) to investigate the influence of three different veneer thicknesses on the stress distribution within the veneer–core complex.
- 13 September 2012
- Published by Wiley in Journal of Investigative and Clinical Dentistry
- Vol. 3 (4) , 291-297
Finite element analysis to compare stress distribution of gold alloy, lithium-disilicate reinforced glass ceramic and zirconia based fixed partial denture
Clinical data indicate that veneer chipping of zirconia core is more likely than with ceramic‐fused‐to‐metal structures. The purposes of this simulation study were to: (a) use two‐dimensional finite element modeling to simulate stresses at the interface of three‐unit posterior fixed partial dentures (FPDs) made with three different core materials; and (b) to investigate the influence of three different veneer thicknesses on the stress distribution within the veneer–core complex.
- 23 June 2012
- Published by Springer Nature in Odontology
- Vol. 101 (2) , 210-215
Accuracy of three-dimensional finite element modeling using two different dental cone beam computed tomography systems
- 23 June 2012
- Published by Springer Nature in Odontology
- Vol. 101 (2) , 210-215
Accuracy of three-dimensional finite element modeling using two different dental cone beam computed tomography systems
- 28 February 2012
- Published by Springer Nature in Odontology
- Vol. 101 (1) , 29-33
Composite resin reinforced with pre-tensioned fibers: a three-dimensional finite element study on stress distribution
Pre-tensioned construction material is utilized in engineering applications of high strength demands. The purpose of this study was to evaluate the effect of the pre-tensioning fibers of fiber-reinforced composite (FRC) using three-dimensional finite element (FE) analysis. The 3D FE models of particulate composite resin (CR), FRC and composite resin reinforced with pre-tensioned fibers (PRE-T-FRC) were constructed. The uniaxial three-point bending test was simulated using FE analysis to calculate the principal stress distribution. In the FRC and PRE-T-FRC, stresses were higher than CR, and they were located in the fiber. However, the maximum principal stress value at the composite of PRE-T-FRC was lower than the FRC and CR. Composite resin reinforced with pre-tensioned fibers was advantageous for stress distribution and lowering the stress at the composite itself. Experimental studies on physical properties of pre-tensioned FRC are encouraged to be conducted.
- 28 February 2012
- Published by Springer Nature in Odontology
- Vol. 101 (1) , 29-33
Composite resin reinforced with pre-tensioned fibers: a three-dimensional finite element study on stress distribution
Pre-tensioned construction material is utilized in engineering applications of high strength demands. The purpose of this study was to evaluate the effect of the pre-tensioning fibers of fiber-reinforced composite (FRC) using three-dimensional finite element (FE) analysis. The 3D FE models of particulate composite resin (CR), FRC and composite resin reinforced with pre-tensioned fibers (PRE-T-FRC) were constructed. The uniaxial three-point bending test was simulated using FE analysis to calculate the principal stress distribution. In the FRC and PRE-T-FRC, stresses were higher than CR, and they were located in the fiber. However, the maximum principal stress value at the composite of PRE-T-FRC was lower than the FRC and CR. Composite resin reinforced with pre-tensioned fibers was advantageous for stress distribution and lowering the stress at the composite itself. Experimental studies on physical properties of pre-tensioned FRC are encouraged to be conducted.
- 1 January 2012
- Vol. 15 (1) , 41-7
Effect of nanofiller on wear resistance and surface roughness of resin composites.
To compare the wear resistance and surface roughness of nanofiller-containing composites and microhybrid composites after simulated wear. Five microhybrid composites and five nanofiller-containing resin composites were included in the study. Six cylindrical specimens with a diameter of 10 mm and a thickness of 6 mm for each material were prepared. The volume loss, vertical loss and the surface roughness (Ra) were determined after 800 cycles of simulated chewing motion. One specimen of each material was analysed by scanning electron microscopy (SEM) to compare the morphology of the wear surfaces. The microhybrid composites group and nanofiller-containing composites group were tested using the Mann-Whitney U test with a significance level of α = 0.05. For all microhybrid composites, the average wear volume loss and vertical loss were 56.44 mm3 and 730.6 µm, respectively, while the average wear losses of nanofiller-containing composites were 40.15 mm3 and 528.17 µm, respectively. The nanofiller containing composite GNH400N showed the least roughness (Ra = 0.346 ± 0.076 µm), while the conventional microhybrid composite Ceramage showed the highest roughness (Ra = 0.699 ± 0.214 µm). However, wear resistance and surface roughness for the two groups showed no statistical difference. SEM micrographs of the nanofiller-containing composites after wear testing showed smoother and more uniform wear surfaces than for the microhybrid composites. Nanofillers did not significantly influence the wear resistance of resin composites, but might improve the surface roughness of resin composites.
- 1 January 2012
- Vol. 15 (1) , 41-7
Effect of nanofiller on wear resistance and surface roughness of resin composites.
To compare the wear resistance and surface roughness of nanofiller-containing composites and microhybrid composites after simulated wear. Five microhybrid composites and five nanofiller-containing resin composites were included in the study. Six cylindrical specimens with a diameter of 10 mm and a thickness of 6 mm for each material were prepared. The volume loss, vertical loss and the surface roughness (Ra) were determined after 800 cycles of simulated chewing motion. One specimen of each material was analysed by scanning electron microscopy (SEM) to compare the morphology of the wear surfaces. The microhybrid composites group and nanofiller-containing composites group were tested using the Mann-Whitney U test with a significance level of α = 0.05. For all microhybrid composites, the average wear volume loss and vertical loss were 56.44 mm3 and 730.6 µm, respectively, while the average wear losses of nanofiller-containing composites were 40.15 mm3 and 528.17 µm, respectively. The nanofiller containing composite GNH400N showed the least roughness (Ra = 0.346 ± 0.076 µm), while the conventional microhybrid composite Ceramage showed the highest roughness (Ra = 0.699 ± 0.214 µm). However, wear resistance and surface roughness for the two groups showed no statistical difference. SEM micrographs of the nanofiller-containing composites after wear testing showed smoother and more uniform wear surfaces than for the microhybrid composites. Nanofillers did not significantly influence the wear resistance of resin composites, but might improve the surface roughness of resin composites.
- Open Access
- 1 July 2011
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 55 (3) , 146-153
The effect of surface treatment on bond strength of layering porcelain and hybrid composite bonded to zirconium dioxide ceramics
- 1 July 2011
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 55 (3) , 146-153
Open AccessThe effect of surface treatment on bond strength of layering porcelain and hybrid composite bonded to zirconium dioxide ceramics
- 1 June 2011
- Vol. 13 (3) , 267-277
Effect of Cyclic Impact Load on Shear Bond Strength of Zirconium Dioxide Ceramics
To investigate the influence of cyclic impact load and the number of load cycles on compressive shear bond strength under the three different cements. The following materials were used: Super Bond C&B (SB) and Panavia Fluoro Cement (PF) as adhesive resin cements, Fuji Luting (FL) as a resin-modified glass-ionomer cement, and zirconium dioxide ceramics as adherend. Before the shear bond test, three different impact loading conditions (compressive direction, shear direction, and no impact) and the number of load cycles (1 to 106 cycles), were performed. A total of 189 specimens (n = 3/group) were randomly assigned to groups and tested. A cyclic impact test was performed by applying a load of 98N at a distance of 40 mm and a loading cycle frequency of 1 Hz. All results were statistically analyzed with two-way ANOVA and Tukey's multiple comparison test. Shear bond strengths of SB, PF, and FL subjected to no cyclic impact load were 21.6 to 53.8 MPa in SB, 27.0 to 63.6 MPa in PF, and 20.0 to 35.9 MPa in FL. The shear bond strength of SB and PF increased to a certain degree from one to 105 cycles, while FL did likewise from one to 104 cycles. The shear bond strengths of SB, PF, and FL were greatest without cyclic impact, followed by compressive and then shear cyclic impact.
- 1 June 2011
- Vol. 13 (3) , 267-277
Effect of Cyclic Impact Load on Shear Bond Strength of Zirconium Dioxide Ceramics
To investigate the influence of cyclic impact load and the number of load cycles on compressive shear bond strength under the three different cements. The following materials were used: Super Bond C&B (SB) and Panavia Fluoro Cement (PF) as adhesive resin cements, Fuji Luting (FL) as a resin-modified glass-ionomer cement, and zirconium dioxide ceramics as adherend. Before the shear bond test, three different impact loading conditions (compressive direction, shear direction, and no impact) and the number of load cycles (1 to 106 cycles), were performed. A total of 189 specimens (n = 3/group) were randomly assigned to groups and tested. A cyclic impact test was performed by applying a load of 98N at a distance of 40 mm and a loading cycle frequency of 1 Hz. All results were statistically analyzed with two-way ANOVA and Tukey's multiple comparison test. Shear bond strengths of SB, PF, and FL subjected to no cyclic impact load were 21.6 to 53.8 MPa in SB, 27.0 to 63.6 MPa in PF, and 20.0 to 35.9 MPa in FL. The shear bond strength of SB and PF increased to a certain degree from one to 105 cycles, while FL did likewise from one to 104 cycles. The shear bond strengths of SB, PF, and FL were greatest without cyclic impact, followed by compressive and then shear cyclic impact.