Daniel P. Fedorko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Daniel P. Fedorko has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Esther C. Williams
<!--label omitted: 1-->Microbiology Service, Clinical Pathology Department, Warren Grant Magnuson Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
2 shared publicationsA M Hruszkewycz
1 shared publicationCharles P Cartwright
Clinical Microbiology Laboratory, Hennepin County Medical Center, Minneapolis, MN 55415, USA
1 shared publicationCynthia J. Reichelderfer
<!--label omitted: 2-->Department of Clinical Pathology, Suburban Hospital, Bethesda, Maryland 208142
1 shared publicationD Bertucci
1 shared publicationE C Williams
Clinical Pathology Department, Warren G. Magnuson, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892, USA
1 shared publication
Latest Publications
- 28 February 2012
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 31 (9) , 2257-2262
Identification of clinical isolates of anaerobic bacteria using matrix-assisted laser desorption ionization-time of flight mass spectrometry
We evaluated the use of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF) for the rapid identification of anaerobic bacteria that had been isolated from clinical specimens and previously identified by 16s rRNA sequencing. The Bruker Microflex MALDI-TOF instrument with the Biotyper Software was used. We tested 152 isolates of anaerobic bacteria from 24 different genera and 75 different species. A total of 125 isolates (82%) had Biotyper software scores greater than 2.0 and the correct identification to genus and species was made by MALDI-TOF for 120 (79%) of isolates. Of the 12 isolates with a score between 1.8 and 2.0, 2 (17%) organisms were incorrectly identified by MALDI-TOF. Only 15 (10%) isolates had a score less than 1.8 and MALDI-TOF gave the wrong genus and species for four isolates, the correct genus for two isolates, and the correct genus and species for nine isolates. Therefore, we found the Bruker MALDI-TOF MicroFlex LT with an expanded database and the use of bacteria extracts rather than whole organisms correctly identified 130 of 152 (86%) isolates to genus and species when the cut-off for an acceptable identification was a spectrum score ≥1.8.
- 28 February 2012
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 31 (9) , 2257-2262
Identification of clinical isolates of anaerobic bacteria using matrix-assisted laser desorption ionization-time of flight mass spectrometry
We evaluated the use of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF) for the rapid identification of anaerobic bacteria that had been isolated from clinical specimens and previously identified by 16s rRNA sequencing. The Bruker Microflex MALDI-TOF instrument with the Biotyper Software was used. We tested 152 isolates of anaerobic bacteria from 24 different genera and 75 different species. A total of 125 isolates (82%) had Biotyper software scores greater than 2.0 and the correct identification to genus and species was made by MALDI-TOF for 120 (79%) of isolates. Of the 12 isolates with a score between 1.8 and 2.0, 2 (17%) organisms were incorrectly identified by MALDI-TOF. Only 15 (10%) isolates had a score less than 1.8 and MALDI-TOF gave the wrong genus and species for four isolates, the correct genus for two isolates, and the correct genus and species for nine isolates. Therefore, we found the Bruker MALDI-TOF MicroFlex LT with an expanded database and the use of bacteria extracts rather than whole organisms correctly identified 130 of 152 (86%) isolates to genus and species when the cut-off for an acceptable identification was a spectrum score ≥1.8.
- Open Access
- 1 September 2005
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 43 (9) , 4602-4606
Comparison of Methods for Detection of Vaccinia Virus in Patient Specimens
We analyzed a shell vial culture assay (SVA), real-time PCR, and a direct fluorescent antibody assay (DFA) for rapid detection of vaccinia virus from vaccination sites of Dryvax vaccine recipients. Of 47 samples assayed, 100% were positive by PCR, 89% were positive by SVA, and 40% were positive by DFA. DFA was limited by the need for adequate numbers of cells, with 32% of samples inadequate for interpretation. DFA performed better with specimens from patients who had not previously received the vaccine. PCR was positive for longer times postvaccination than was SVA. Infectious virus could be recovered after 45 min of acetone fixation of shell vial coverslips. Commercially available polyclonal antibodies cross-reacted with other orthopoxviruses and herpes simplex 1, but commercially available monoclonal antibodies were specific for vaccinia virus. In summary, PCR was the most sensitive test for detecting vaccinia virus in clinical specimens, while the DFA was the most rapid but the least sensitive test.
- 1 September 2005
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 43 (9) , 4602-4606
Open AccessComparison of Methods for Detection of Vaccinia Virus in Patient Specimens
We analyzed a shell vial culture assay (SVA), real-time PCR, and a direct fluorescent antibody assay (DFA) for rapid detection of vaccinia virus from vaccination sites of Dryvax vaccine recipients. Of 47 samples assayed, 100% were positive by PCR, 89% were positive by SVA, and 40% were positive by DFA. DFA was limited by the need for adequate numbers of cells, with 32% of samples inadequate for interpretation. DFA performed better with specimens from patients who had not previously received the vaccine. PCR was positive for longer times postvaccination than was SVA. Infectious virus could be recovered after 45 min of acetone fixation of shell vial coverslips. Commercially available polyclonal antibodies cross-reacted with other orthopoxviruses and herpes simplex 1, but commercially available monoclonal antibodies were specific for vaccinia virus. In summary, PCR was the most sensitive test for detecting vaccinia virus in clinical specimens, while the DFA was the most rapid but the least sensitive test.
- 1 May 2002
- Published by Elsevier in Clinical Microbiology Newsletter
- Vol. 24 (10) , 76-79
Controversies in Clostridium difficile testing
- 1 May 2002
- Published by Elsevier in Clinical Microbiology Newsletter
- Vol. 24 (10) , 76-79
Controversies in Clostridium difficile testing
- 1 October 2001
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 65 (4) , 397-401
Speciation of human microsporidia by polymerase chain reaction single-strand conformation polymorphism.
We describe the application of single-strand conformation polymorphism (SSCP) analysis to the speciation of human microsporidia after polymerase chain reaction (PCR) amplification with the panmicrosporidian primers PMP1 and PMP2. We compared the DNA extracted and amplified from different genotypes or isolates of Enterocytozoon bieneusi, Encephalitozoon cuniculi, E. hellem, and E. intestinalis plus an isolate of Vittaforma corneae. The PCR-SSCP, when performed at 20 degrees C, generated 2 bands in distinctive, reproducible patterns in polyacrylamide gels for each species of microsporidia tested, regardless of genotype or isolate. We found PCR-SSCP to be an easy and reproducible method for speciation of human microsporidia when the primer pair PMP1 and PMP2 is used.
- 1 October 2001
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 65 (4) , 397-401
Speciation of human microsporidia by polymerase chain reaction single-strand conformation polymorphism.
We describe the application of single-strand conformation polymorphism (SSCP) analysis to the speciation of human microsporidia after polymerase chain reaction (PCR) amplification with the panmicrosporidian primers PMP1 and PMP2. We compared the DNA extracted and amplified from different genotypes or isolates of Enterocytozoon bieneusi, Encephalitozoon cuniculi, E. hellem, and E. intestinalis plus an isolate of Vittaforma corneae. The PCR-SSCP, when performed at 20 degrees C, generated 2 bands in distinctive, reproducible patterns in polyacrylamide gels for each species of microsporidia tested, regardless of genotype or isolate. We found PCR-SSCP to be an easy and reproducible method for speciation of human microsporidia when the primer pair PMP1 and PMP2 is used.
- 1 July 2000
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 38 (7) , 2781-2783
Performance of Three Enzyme Immunoassays and Two Direct Fluorescence Assays for Detection of Giardia lamblia in Stool Specimens Preserved in ECOFIX
ECOFIX is a single-vial stool preservative that is both formalin- and mercury-free. We evaluated the abilities of three commercialGiardia lamblia-specific enzyme immunoassays (EIAs) (ProSpecT Giardia Microplate Assay [Alexon-Trend Inc.], Giardia Test [Techlab], and Premier Giardia lamblia [Meridian Diagnostics, Inc.]) and two commercial direct fluorescent-antibody (FA) assays for G. lamblia(Crypto/Giardia IF Test [Techlab] and Merifluor Cryptosporidium/Giardia [Meridian Diagnostics, Inc.]) to detectG. lamblia in 34 G. lamblia-positive and 44G. lamblia-negative stool specimens (determined by traditional examination for ova and parasites) preserved in ECOFIX compared to their abilities to detect G. lamblia in the same specimens preserved in formalin as the “gold standard” for each assay. Of the 34 formalin-fixed positive specimens, the number detected by each assay was as follows:, Alexon EIA, 34; Meridian EIA, 27; Techlab EIA, 29; Meridian FA assay, 31; and Techlab FA assay, 28. Both FA tests and the Alexon EIA performed well with ECOFIX, but the other two EIAs detected fewer positive specimens (the difference was statistically significant with the Techlab EIA) when ECOFIX was the preservative. Use of G. lamblia cyst antigen from cultured organisms preserved in formalin and ECOFIX demonstrated that the Alexon EIA could detect smaller amounts of antigen in ECOFIX than the other two EIAs could and suggested that cyst antigen is more stable in formalin. We recommend that laboratories use an FA assay or the Alexon EIA if they plan to use ECOFIX as their stool preservative.
- 1 July 2000
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 38 (7) , 2781-2783
Performance of Three Enzyme Immunoassays and Two Direct Fluorescence Assays for Detection of Giardia lamblia in Stool Specimens Preserved in ECOFIX
ECOFIX is a single-vial stool preservative that is both formalin- and mercury-free. We evaluated the abilities of three commercialGiardia lamblia-specific enzyme immunoassays (EIAs) (ProSpecT Giardia Microplate Assay [Alexon-Trend Inc.], Giardia Test [Techlab], and Premier Giardia lamblia [Meridian Diagnostics, Inc.]) and two commercial direct fluorescent-antibody (FA) assays for G. lamblia(Crypto/Giardia IF Test [Techlab] and Merifluor Cryptosporidium/Giardia [Meridian Diagnostics, Inc.]) to detectG. lamblia in 34 G. lamblia-positive and 44G. lamblia-negative stool specimens (determined by traditional examination for ova and parasites) preserved in ECOFIX compared to their abilities to detect G. lamblia in the same specimens preserved in formalin as the “gold standard” for each assay. Of the 34 formalin-fixed positive specimens, the number detected by each assay was as follows:, Alexon EIA, 34; Meridian EIA, 27; Techlab EIA, 29; Meridian FA assay, 31; and Techlab FA assay, 28. Both FA tests and the Alexon EIA performed well with ECOFIX, but the other two EIAs detected fewer positive specimens (the difference was statistically significant with the Techlab EIA) when ECOFIX was the preservative. Use of G. lamblia cyst antigen from cultured organisms preserved in formalin and ECOFIX demonstrated that the Alexon EIA could detect smaller amounts of antigen in ECOFIX than the other two EIAs could and suggested that cyst antigen is more stable in formalin. We recommend that laboratories use an FA assay or the Alexon EIA if they plan to use ECOFIX as their stool preservative.
- 1 September 1999
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 37 (9) , 3044-3047
Evaluation of Two Rapid Assays for Detection of Clostridium difficile Toxin A in Stool Specimens
Rapid laboratory diagnosis of Clostridium difficile -associated diarrhea (CDAD) is highly desirable in the setting of hospital cost containment. We tested 654 stool specimens to compare the performance of two assays for rapid detection of toxin A, the Immunocard Toxin A test (Meridian Diagnostics, Inc.) and the Culturette Brand Toxin CD enzyme immunoassay (EIA) (Becton Dickinson Microbiology Systems), with a cytotoxin assay (Cytotoxi Test; Advanced Clinical Diagnostics) and culture on cycloserine-cefoxitin-fructose agar followed by determination of the production of toxins A and B. A chart review was performed for patients whose stool specimens provided positive results on one to three of the assays. With the “gold standard” of all four assays positive or chart review evidence of CDAD, 97 (14.8%) stool specimens were positive by one or more assays and 557 (85.2%) were negative by all methods. Total agreement for all assays was 90.5% (592 of 654). The sensitivity, specificity, positive predictive value, and negative predictive value for toxigenic culture were 94.7, 98.6, 87.1, and 99.5%, respectively, for toxigenic culture; 87.7, 98.6, 86.2, and 98.8%, respectively, for the cytotoxin assay; 71.9, 99.3, 91.1, and 97.3%, respectively, for the Immunocard; and 68.4, 99.1, 88.6, and 96.9%, respectively, for the Culturette EIA. While easy to perform and highly specific, these rapid assays do not appear to be sufficient for accurate diagnosis of CDAD.
- 1 September 1999
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 37 (9) , 3044-3047
Evaluation of Two Rapid Assays for Detection of Clostridium difficile Toxin A in Stool Specimens
Rapid laboratory diagnosis of Clostridium difficile -associated diarrhea (CDAD) is highly desirable in the setting of hospital cost containment. We tested 654 stool specimens to compare the performance of two assays for rapid detection of toxin A, the Immunocard Toxin A test (Meridian Diagnostics, Inc.) and the Culturette Brand Toxin CD enzyme immunoassay (EIA) (Becton Dickinson Microbiology Systems), with a cytotoxin assay (Cytotoxi Test; Advanced Clinical Diagnostics) and culture on cycloserine-cefoxitin-fructose agar followed by determination of the production of toxins A and B. A chart review was performed for patients whose stool specimens provided positive results on one to three of the assays. With the “gold standard” of all four assays positive or chart review evidence of CDAD, 97 (14.8%) stool specimens were positive by one or more assays and 557 (85.2%) were negative by all methods. Total agreement for all assays was 90.5% (592 of 654). The sensitivity, specificity, positive predictive value, and negative predictive value for toxigenic culture were 94.7, 98.6, 87.1, and 99.5%, respectively, for toxigenic culture; 87.7, 98.6, 86.2, and 98.8%, respectively, for the cytotoxin assay; 71.9, 99.3, 91.1, and 97.3%, respectively, for the Immunocard; and 68.4, 99.1, 88.6, and 96.9%, respectively, for the Culturette EIA. While easy to perform and highly specific, these rapid assays do not appear to be sufficient for accurate diagnosis of CDAD.
- 1 May 1997
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 35 (5) , 1258-9
Use of cycloserine-cefoxitin-fructose agar and L-proline-aminopeptidase (PRO Discs) in the rapid identification of Clostridium difficile
The PRO Disc (Carr-Scarborough Microbiologicals, Inc., Decatur, Ga.) can be used to screen for L-proline-aminopeptidase produced by Clostridium difficile grown on cycloserine-cefoxitin-fructose agar (CCFA). Fifty stored isolates of C. difficile (48 toxin-positive and 2 toxin-negative isolates) and 47 fresh C. difficile isolates (39 toxin-positive and 8 toxin-negative isolates) were all PRO Disc positive. Other Clostridium species that were PRO Disc positive could be differentiated from C. difficile by failure to grow on CCFA, different colonial morphology on CCFA, or morphology upon Gram staining.
- 1 May 1997
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 35 (5) , 1258-9
Use of cycloserine-cefoxitin-fructose agar and L-proline-aminopeptidase (PRO Discs) in the rapid identification of Clostridium difficile
The PRO Disc (Carr-Scarborough Microbiologicals, Inc., Decatur, Ga.) can be used to screen for L-proline-aminopeptidase produced by Clostridium difficile grown on cycloserine-cefoxitin-fructose agar (CCFA). Fifty stored isolates of C. difficile (48 toxin-positive and 2 toxin-negative isolates) and 47 fresh C. difficile isolates (39 toxin-positive and 8 toxin-negative isolates) were all PRO Disc positive. Other Clostridium species that were PRO Disc positive could be differentiated from C. difficile by failure to grow on CCFA, different colonial morphology on CCFA, or morphology upon Gram staining.
- Open Access
- 1 September 1996
- Published by Centers for Disease Control and Prevention (CDC) in Emerging Infectious Diseases
- Vol. 2 (3) , 183-191
Application of Molecular Techniques
Volume 2, Number 3—July 1996 - Emerging Infectious Disease journal - CDC
- 1 September 1996
- Published by Centers for Disease Control and Prevention (CDC) in Emerging Infectious Diseases
- Vol. 2 (3) , 183-191
Open AccessApplication of Molecular Techniques
Volume 2, Number 3—July 1996 - Emerging Infectious Disease journal - CDC