Eiji Okamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eiji Okamoto has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Yoshinori Mitamura
Hokkaido University
6 shared publicationsYoshikuni Kato
Graduate School of Engineering and Science, Tokai University, Sapporo, Japan
4 shared publications- Yoshinori Mitamura
Department of Biomedical Systems Engineering, Graduate School of Information Science and Technology, Hokkaido University, Kita 14 Nishi 9, Kita-ku, Sapporo 060-0814, Japan
4 shared publications Kazuyuki Seino
Department of Human Science and Informatics, School of Bioscience and Engineering, Tokai University, Sapporo
3 shared publicationsHidekazu Miura
Department of Medical Engineering and Cardiology, Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan
2 shared publicationsSakiko Kikuchi
Graduate School of Engineering and Science, Tokai University, Sapporo, Japan
2 shared publications
Latest Publications
- 1 April 2015
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 380, 54-60
Numerical analysis of the effects of a high gradient magnetic field on flowing erythrocytes in a membrane oxygenator
- 1 April 2015
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 380, 54-60
Numerical analysis of the effects of a high gradient magnetic field on flowing erythrocytes in a membrane oxygenator
- 19 November 2014
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 18 (2) , 181-184
Passive magnetic bearing in the 3rd generation miniature axial flow pump-the valvo pump 2
The new miniature axial flow pump (valvo pump 2) that is installed at the base of the ascending aorta consists of a six-phase stator, an impeller in which four neodymium magnets are incorporated, and passive magnetic bearings that suspend the impeller for axial levitation. The impeller is sustained by hydrodynamic force between the blade tip of the impeller and the inner housing of the stator. The passive magnetic bearing consists of a ring neodymium magnet and a columnar neodymium magnet. The ring neodymium magnet is set in the stationary side and the columnar neodymium magnet is incorporated in the impeller shaft. Both neodymium magnets are coaxially mounted, and the anterior and posterior passive magnetic bearings suspend the impeller by repulsion force against the hydrodynamic force that acts to move the impeller in the inflow port direction. The passive magnetic bearing was evaluated by a tensile test, and the levitation force of 8.5 N and stiffness of 2.45 N/mm was obtained. Performance of the axial flow pump was evaluated by an in vitro experiment. The passive magnetic bearing showed sufficient levitation capacity to suspend the impeller in an axial direction. In conclusion, the passive magnetic bearing is promising to be one of levitation technology for the third-generation axial flow blood pump.
- 19 November 2014
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 18 (2) , 181-184
Passive magnetic bearing in the 3rd generation miniature axial flow pump-the valvo pump 2
The new miniature axial flow pump (valvo pump 2) that is installed at the base of the ascending aorta consists of a six-phase stator, an impeller in which four neodymium magnets are incorporated, and passive magnetic bearings that suspend the impeller for axial levitation. The impeller is sustained by hydrodynamic force between the blade tip of the impeller and the inner housing of the stator. The passive magnetic bearing consists of a ring neodymium magnet and a columnar neodymium magnet. The ring neodymium magnet is set in the stationary side and the columnar neodymium magnet is incorporated in the impeller shaft. Both neodymium magnets are coaxially mounted, and the anterior and posterior passive magnetic bearings suspend the impeller by repulsion force against the hydrodynamic force that acts to move the impeller in the inflow port direction. The passive magnetic bearing was evaluated by a tensile test, and the levitation force of 8.5 N and stiffness of 2.45 N/mm was obtained. Performance of the axial flow pump was evaluated by an in vitro experiment. The passive magnetic bearing showed sufficient levitation capacity to suspend the impeller in an axial direction. In conclusion, the passive magnetic bearing is promising to be one of levitation technology for the third-generation axial flow blood pump.
- 1 January 2014
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 24 (4) , 1735-1742
Measurement of electrode–tissue interface impedance for improvement of a transcutaneous data transmission using human body as transmission medium
The electrical property between an electrode and skin or tissue is one of the important issues for communication performance of the transcutaneous communication system (TCS) using a human body as a conductive medium. In this study, we used a simple m
- 1 January 2014
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 24 (4) , 1735-1742
Measurement of electrode–tissue interface impedance for improvement of a transcutaneous data transmission using human body as transmission medium
The electrical property between an electrode and skin or tissue is one of the important issues for communication performance of the transcutaneous communication system (TCS) using a human body as a conductive medium. In this study, we used a simple m
- 1 January 2013
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 23 (1-2) , 155-162
Transcutaneous communication system using the human body as conductive medium: Influence of transmission data current on the heart
We developed a new transcutaneous communication system (TCS) that uses the human body as a conductive medium for monitoring and controlling artificial hearts and other artificial organs in the body. In this study, the physiological effect of data cur
- 1 January 2013
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 23 (1-2) , 155-162
Transcutaneous communication system using the human body as conductive medium: Influence of transmission data current on the heart
We developed a new transcutaneous communication system (TCS) that uses the human body as a conductive medium for monitoring and controlling artificial hearts and other artificial organs in the body. In this study, the physiological effect of data cur
- 19 July 2012
- Published by Wiley in Artificial Organs
- Vol. 36 (10) , 852-858
A New Transcutaneous Bidirectional Communication for Monitoring Implanted Artificial Heart Using the Human Body as a Conductive Medium
A transcutaneous communication system (TCS) is a key technology for monitoring and controlling artificial hearts and other artificial organs in the body. In this study, we developed a new TCS that uses the human body as a conductive medium. Direct data exchange provides a higher level of communication security compared to that of wireless methods without physical constraints such as an external wire. The external and internal units of the new TCS each consist mainly of a data transmitter and a data receiver. The data transmitter has an amplitude shift keying (ASK) modulator (carrier frequencies: 4 and 10 MHz) and an electrode. The ASK‐modulated data current is led into the body through the electrode, and it flows back to the energy source through the body, the data receiver, and the earth ground that includes all conductors and dielectrics in the environment that are in close proximity to the patient. Performance of the TCS was evaluated by a communication test on the surface of the human body and in an animal experiment using a goat. The TCS was able to transmit data concurrently for 4 weeks between everywhere on the surface of the body and everywhere inside the body under full‐duplex communication at a transmission rate of 115 kbps. The power consumption of each TCS unit was 125 mW with an ASK‐modulated current of 7 mA (root‐mean‐square). While further study is required to secure its safety, the newly developed TCS has promise to be a next‐generation transcutaneous communication device.
- 19 July 2012
- Published by Wiley in Artificial Organs
- Vol. 36 (10) , 852-858
A New Transcutaneous Bidirectional Communication for Monitoring Implanted Artificial Heart Using the Human Body as a Conductive Medium
A transcutaneous communication system (TCS) is a key technology for monitoring and controlling artificial hearts and other artificial organs in the body. In this study, we developed a new TCS that uses the human body as a conductive medium. Direct data exchange provides a higher level of communication security compared to that of wireless methods without physical constraints such as an external wire. The external and internal units of the new TCS each consist mainly of a data transmitter and a data receiver. The data transmitter has an amplitude shift keying (ASK) modulator (carrier frequencies: 4 and 10 MHz) and an electrode. The ASK‐modulated data current is led into the body through the electrode, and it flows back to the energy source through the body, the data receiver, and the earth ground that includes all conductors and dielectrics in the environment that are in close proximity to the patient. Performance of the TCS was evaluated by a communication test on the surface of the human body and in an animal experiment using a goat. The TCS was able to transmit data concurrently for 4 weeks between everywhere on the surface of the body and everywhere inside the body under full‐duplex communication at a transmission rate of 115 kbps. The power consumption of each TCS unit was 125 mW with an ASK‐modulated current of 7 mA (root‐mean‐square). While further study is required to secure its safety, the newly developed TCS has promise to be a next‐generation transcutaneous communication device.
- 21 August 2011
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 15 (1) , 99-103
Interface of data transmission for a transcutaneous communication system using the human body as transmission medium
We have been developing a new transcutaneous communication system (TCS) that uses the human body as an electrical conductive medium. We studied an interface circuit of the TCS in order to optimize the leading data current into the human body effectively. Two types of LC circuits were examined for the interface circuit, one was an LC series-parallel circuit, and the other was a parallel-connected LC circuit. The LC series-parallel circuit connected to the body could be tuned to a resonant frequency, and the frequency was determined by the values of an external inductor and an external capacitor. Permittivity of the body did not influence the electrical resonance. Connection of the LC series-parallel circuit to the body degraded the quality factor Q because of the conductivity of the body. However, the LC parallel-connected circuit when connected to the body did not indicate electrical resonance. The LC series-parallel circuit restricts a direct current and a low-frequency current to flow into the body; thus, it can prevent a patient from getting a shock. According to the above results, an LC series-parallel circuit is an optimum interface circuit between the TCS and the body for leading data current into the body effectively and safely.
- 21 August 2011
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 15 (1) , 99-103
Interface of data transmission for a transcutaneous communication system using the human body as transmission medium
We have been developing a new transcutaneous communication system (TCS) that uses the human body as an electrical conductive medium. We studied an interface circuit of the TCS in order to optimize the leading data current into the human body effectively. Two types of LC circuits were examined for the interface circuit, one was an LC series-parallel circuit, and the other was a parallel-connected LC circuit. The LC series-parallel circuit connected to the body could be tuned to a resonant frequency, and the frequency was determined by the values of an external inductor and an external capacitor. Permittivity of the body did not influence the electrical resonance. Connection of the LC series-parallel circuit to the body degraded the quality factor Q because of the conductivity of the body. However, the LC parallel-connected circuit when connected to the body did not indicate electrical resonance. The LC series-parallel circuit restricts a direct current and a low-frequency current to flow into the body; thus, it can prevent a patient from getting a shock. According to the above results, an LC series-parallel circuit is an optimum interface circuit between the TCS and the body for leading data current into the body effectively and safely.
- 29 December 2010
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 14 (1) , 23-30
A magnetic fluid seal for rotary blood pumps: effects of seal structure on long-term performance in liquid
A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a “shield” mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.
- 29 December 2010
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 14 (1) , 23-30
A magnetic fluid seal for rotary blood pumps: effects of seal structure on long-term performance in liquid
A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a “shield” mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.
- 8 May 2010
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 13 (2) , 117-120
Basic study of a transcutaneous information transmission system using intra-body communication
The transcutaneous communication system (TCS) is one of the key technologies for monitoring and controling artificial hearts and other artificial organs in the body. In this study, we have developed a new TCS that uses the human body as a conductive medium. Having no energy conversion from electric currents into electromagnetic waves and light provides energy-saving data transmission with a simple electrical circuit. Each unit of the TCS mainly consists of two electrodes, an amplitude shift keying (ASK) modulator and an ASK demodulator (carrier frequency: 4 and 10 MHz). A resonant frequency of an L-C tank circuit including the capacitance component of the body is tuned into each carrier frequency in order to apply the data current effectively into the body. Performance of the TCS was evaluated by a communication test on the surface of a human body. The TCS was able to transmit 3,315 bytes of data bi-directionally at a transmission rate of 115 kbps from a left wrist to a right forearm, to an abdomen and to a left calf without communication error. The power consumption of each TCS unit was 125 mW with an ASK modulated current of 7 mA (RMS). While further study is required to secure its safety, the TCS promises to be a next-generation transcutaneous communication device.
- 8 May 2010
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 13 (2) , 117-120
Basic study of a transcutaneous information transmission system using intra-body communication
The transcutaneous communication system (TCS) is one of the key technologies for monitoring and controling artificial hearts and other artificial organs in the body. In this study, we have developed a new TCS that uses the human body as a conductive medium. Having no energy conversion from electric currents into electromagnetic waves and light provides energy-saving data transmission with a simple electrical circuit. Each unit of the TCS mainly consists of two electrodes, an amplitude shift keying (ASK) modulator and an ASK demodulator (carrier frequency: 4 and 10 MHz). A resonant frequency of an L-C tank circuit including the capacitance component of the body is tuned into each carrier frequency in order to apply the data current effectively into the body. Performance of the TCS was evaluated by a communication test on the surface of a human body. The TCS was able to transmit 3,315 bytes of data bi-directionally at a transmission rate of 115 kbps from a left wrist to a right forearm, to an abdomen and to a left calf without communication error. The power consumption of each TCS unit was 125 mW with an ASK modulated current of 7 mA (RMS). While further study is required to secure its safety, the TCS promises to be a next-generation transcutaneous communication device.
- 1 September 1996
- Published by Wolters Kluwer Health
- Vol. 42 (5) , M402-405
Ferromagnetic Artificial Cells for Artificial Circulation
It is known that deoxygenated blood is paramagnetic. A ferrofluidic actuator for an implantable artificial heart has been studied. The magnetic fluid consists of ferromagnetic magnetite particles (10 nm). If artificial cells encapsulating ferromagnetic particles are mixed in blood, the circulation is maintained by applying a magnetic field to the blood. An array of two poles of ring solenoids with a gap of 10 mm was mounted near the glass tube (7.60 mm inner diameter). The flux density was 0.236 Tesla. Two experiments were conducted using models of artificial cells: 1) the magnetic fluid and 2) the magnetic fluid and an iron cylinder (6.67 mm in diameter and 28.7 mm in length). A flow of 38 to 8 ml/min was obtained against a pressure of 12.5 to 16.3 mmHg in experiment 1, and 80 to 24 ml/min against a pressure of 53 to 240 mmHg in experiment 2. Calculation showed that magnetic fluids could move against a pressure of 100 mmHg if they had a magnetization of 113 kA/m (B = 0.236 Tesla). The magnetic fluid has a magnetization of 35.6 kA/m, whereas the magnetite is 479 kA/m, and that of iron 1398 kA/m. Artificial circulation with ferromagnetic artificial cells could be feasible if artificial cells with a magnetization of 113 kA/m are developed.
- 1 September 1996
- Published by Wolters Kluwer Health
- Vol. 42 (5) , M402-405
Ferromagnetic Artificial Cells for Artificial Circulation
It is known that deoxygenated blood is paramagnetic. A ferrofluidic actuator for an implantable artificial heart has been studied. The magnetic fluid consists of ferromagnetic magnetite particles (10 nm). If artificial cells encapsulating ferromagnetic particles are mixed in blood, the circulation is maintained by applying a magnetic field to the blood. An array of two poles of ring solenoids with a gap of 10 mm was mounted near the glass tube (7.60 mm inner diameter). The flux density was 0.236 Tesla. Two experiments were conducted using models of artificial cells: 1) the magnetic fluid and 2) the magnetic fluid and an iron cylinder (6.67 mm in diameter and 28.7 mm in length). A flow of 38 to 8 ml/min was obtained against a pressure of 12.5 to 16.3 mmHg in experiment 1, and 80 to 24 ml/min against a pressure of 53 to 240 mmHg in experiment 2. Calculation showed that magnetic fluids could move against a pressure of 100 mmHg if they had a magnetization of 113 kA/m (B = 0.236 Tesla). The magnetic fluid has a magnetization of 35.6 kA/m, whereas the magnetite is 479 kA/m, and that of iron 1398 kA/m. Artificial circulation with ferromagnetic artificial cells could be feasible if artificial cells with a magnetization of 113 kA/m are developed.
- 1 January 1989
- Published by The Society of Instrument and Control Engineers in Transactions of the Society of Instrument and Control Engineers
- Vol. 25 (6) , 638-643
Development of a Simple Magnetic Position Sensor and Its Application to Artificial Hearts
- 1 January 1989
- Published by The Society of Instrument and Control Engineers in Transactions of the Society of Instrument and Control Engineers
- Vol. 25 (6) , 638-643
Development of a Simple Magnetic Position Sensor and Its Application to Artificial Hearts