Peter Sterling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Peter Sterling has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Vijay Balasubramanian
2 shared publicationsAndrew Hsu
Department of Neuroscience, University of Pennsylvania, Philadelphia 19104, USA
1 shared publicationEnrico Mugnaini
1 shared publicationGary Matthews
Department of Neurobiology, State University of New York, Stony Brook, NY 11794, USA
1 shared publicationGershon Buchsbaum
Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104
1 shared publicationJeremy E. Niven
1 shared publication
Latest Publications
- Open Access
- 31 March 2016
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 5
How scientists can reduce their carbon footprint
Cutting down on long-distance air travel is the best way to reduce the emission of greenhouse gases by the scientific community.
- 31 March 2016
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 5
Open AccessHow scientists can reduce their carbon footprint
Cutting down on long-distance air travel is the best way to reduce the emission of greenhouse gases by the scientific community.
- 1 March 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (3) , 2267-2275
Some Principles of Retinal Design: The Proctor Lecture
- 1 March 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (3) , 2267-2275
Some Principles of Retinal Design: The Proctor Lecture
- Top Cited Papers
- 1 April 2012
- Published by Elsevier in Physiology & Behavior
- Vol. 106 (1) , 5-15
Allostasis: A model of predictive regulation
- 1 April 2012
- Published by Elsevier in Physiology & Behavior
- Vol. 106 (1) , 5-15
Top Cited PapersAllostasis: A model of predictive regulation
- Open Access
- 11 January 2012
- Published by Society for Neuroscience in The Journal of Neuroscience
- Vol. 32 (2) , 626-638
Why Do Axons Differ in Caliber?
CNS axons differ in diameter (d) by nearly 100-fold (∼0.1–10 μm); therefore, they differ in cross-sectional area (d2) and volume by nearly 10,000-fold. If, as found for optic nerve, mitochondrial volume fraction is constant with axon diameter, energy capacity would rise with axon volume, also asd2. We asked, given constraints on space and energy, what functional requirements set an axon's diameter? Surveying 16 fiber groups spanning nearly the full range of diameters in five species (guinea pig, rat, monkey, locust, octopus), we found the following: (1) thin axons are most numerous; (2) mean firing frequencies, estimated for nine of the identified axon classes, are low for thin fibers and high for thick ones, ranging from ∼1 to >100 Hz; (3) a tract's distribution of fiber diameters, whether narrow or broad, and whether symmetric or skewed, reflects heterogeneity of information rates conveyed by its individual fibers; and (4) mitochondrial volume/axon length rises ≥d2. To explain the pressure toward thin diameters, we note an established law of diminishing returns: an axon, to double its information rate, must more than double its firing rate. Since diameter is apparently linear with firing rate, doubling information rate would more than quadruple an axon's volume and energy use. Thicker axons may be needed to encode features that cannot be efficiently decoded if their information is spread over several low-rate channels. Thus, information rate may be the main variable that sets axon caliber, with axons constrained to deliver information at the lowest acceptable rate.
- 11 January 2012
- Published by Society for Neuroscience in The Journal of Neuroscience
- Vol. 32 (2) , 626-638
Open AccessWhy Do Axons Differ in Caliber?
CNS axons differ in diameter (d) by nearly 100-fold (∼0.1–10 μm); therefore, they differ in cross-sectional area (d2) and volume by nearly 10,000-fold. If, as found for optic nerve, mitochondrial volume fraction is constant with axon diameter, energy capacity would rise with axon volume, also asd2. We asked, given constraints on space and energy, what functional requirements set an axon's diameter? Surveying 16 fiber groups spanning nearly the full range of diameters in five species (guinea pig, rat, monkey, locust, octopus), we found the following: (1) thin axons are most numerous; (2) mean firing frequencies, estimated for nine of the identified axon classes, are low for thin fibers and high for thick ones, ranging from ∼1 to >100 Hz; (3) a tract's distribution of fiber diameters, whether narrow or broad, and whether symmetric or skewed, reflects heterogeneity of information rates conveyed by its individual fibers; and (4) mitochondrial volume/axon length rises ≥d2. To explain the pressure toward thin diameters, we note an established law of diminishing returns: an axon, to double its information rate, must more than double its firing rate. Since diameter is apparently linear with firing rate, doubling information rate would more than quadruple an axon's volume and energy use. Thicker axons may be needed to encode features that cannot be efficiently decoded if their information is spread over several low-rate channels. Thus, information rate may be the main variable that sets axon caliber, with axons constrained to deliver information at the lowest acceptable rate.
- 1 July 2007
- Published by Maximum Academic Press in Visual Neuroscience
- Vol. 24 (4) , 563-571
How robust is a neural circuit?
Design in engineering begins with the problem of robustness—by what factor should intrinsic capacity exceed normal demand? Here we consider robustness for a neural circuit that crosses the retina from cones to ganglion cells. The circuit's task is to represent the visual scene at many successive stages, each time by modulating a stream of stochastic events: photoisomerizations, then transmitter quanta, then spikes. At early stages, the event rates are high to achieve some critical signal-to-noise ratio and temporal bandwidth, which together set the information rate. Then neural circuits concentrate the information and repackage it, so that nearly the same total information can be represented by modulating far lower event rates. This is important for spiking because of its high metabolic cost. Considering various measurements at the outer and inner retina, we conclude that the “safety factors” are about 2–10, similar to other tissues.
- 1 July 2007
- Published by Maximum Academic Press in Visual Neuroscience
- Vol. 24 (4) , 563-571
How robust is a neural circuit?
Design in engineering begins with the problem of robustness—by what factor should intrinsic capacity exceed normal demand? Here we consider robustness for a neural circuit that crosses the retina from cones to ganglion cells. The circuit's task is to represent the visual scene at many successive stages, each time by modulating a stream of stochastic events: photoisomerizations, then transmitter quanta, then spikes. At early stages, the event rates are high to achieve some critical signal-to-noise ratio and temporal bandwidth, which together set the information rate. Then neural circuits concentrate the information and repackage it, so that nearly the same total information can be represented by modulating far lower event rates. This is important for spiking because of its high metabolic cost. Considering various measurements at the outer and inner retina, we conclude that the “safety factors” are about 2–10, similar to other tissues.
- 1 July 2006
- Published by Elsevier in Current Biology
- Vol. 16 (14) , 1428-1434
How Much the Eye Tells the Brain
- 1 July 2006
- Published by Elsevier in Current Biology
- Vol. 16 (14) , 1428-1434
How Much the Eye Tells the Brain
- 1 May 2006
- Published by Maximum Academic Press in Visual Neuroscience
- Vol. 23 (6) , 931-939
Displaced GAD65 amacrine cells of the guinea pig retina are morphologically diverse
The ganglion cell layer of mammalian retina contains numerous amacrine cells. Many belong to one type, the cholinergic starburst cell, but the other types have not been systematically identified. Using a new method to target sparsely represented cell types, we filled about 200 amacrine neurons in the ganglion cell layer of the guinea pig visual streak and identified 11 types. Ten of these resemble types identified in other species with somas in the inner nuclear layer, but one type has not been previously reported. Most of the types and nearly all the injected cells (95%) arborized low in the synaptic layer where they would co-stratify with various classes of ON ganglion cell. The displaced somas (7% of all amacrine cells) thus represent a heterogeneous pool, which are relatively accessible for study of their interactions with ON ganglion cells.
- 1 May 2006
- Published by Maximum Academic Press in Visual Neuroscience
- Vol. 23 (6) , 931-939
Displaced GAD65 amacrine cells of the guinea pig retina are morphologically diverse
The ganglion cell layer of mammalian retina contains numerous amacrine cells. Many belong to one type, the cholinergic starburst cell, but the other types have not been systematically identified. Using a new method to target sparsely represented cell types, we filled about 200 amacrine neurons in the ganglion cell layer of the guinea pig visual streak and identified 11 types. Ten of these resemble types identified in other species with somas in the inner nuclear layer, but one type has not been previously reported. Most of the types and nearly all the injected cells (95%) arborized low in the synaptic layer where they would co-stratify with various classes of ON ganglion cell. The displaced somas (7% of all amacrine cells) thus represent a heterogeneous pool, which are relatively accessible for study of their interactions with ON ganglion cells.
- 1 January 2005
- Published by Elsevier in Trends in Neurosciences
- Vol. 28 (1) , 20-29
Structure and function of ribbon synapses
- 1 January 2005
- Published by Elsevier in Trends in Neurosciences
- Vol. 28 (1) , 20-29
Structure and function of ribbon synapses
- 1 March 2000
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 17 (3) , 635-640
Cost of cone coupling to trichromacy in primate fovea
Cone synaptic terminals couple electrically to their neighbors. This reduces the amplitude of temporally uncorrelated voltage differences between neighbors. For an achromatic stimulus coarser than the cone mosaic, the uncorrelated voltage difference between neighbors represents mostly noise; so noise is reduced more than the signal. Here coupling improves signal-to-noise ratio and enhances contrast sensitivity. But for a chromatic stimulus the uncorrelated voltage difference between neighbors of different spectral type represents mostly signal; so signal would be reduced more than the noise. This cost of cone coupling to encoding chromatic signals was evaluated using a compartmental model of the foveal cone array. When cones sensitive to middle (M) and long (L) wavelengths alternated regularly, and the conductance between a cone and all of its immediate neighbors was 1000 pS (∼2 connexons/cone pair), coupling reduced the difference between the L and M action spectra by nearly fivefold, from about 38% to 8%. However, L and M cones distribute randomly in the mosaic, forming small patches of like type, and within a patch the responses to a chromatic stimulus are correlated. In such a mosaic, coupling still reduced the difference between the L and M action spectra, but only by 2.4-fold, to about 18%. This result is independent of the L/M ratio. Thus “patchiness” of the L/M mosaic allows cone coupling to improve achromatic contrast sensitivity while minimizing the cost to chromatic sensitivity.
- 1 March 2000
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 17 (3) , 635-640
Cost of cone coupling to trichromacy in primate fovea
Cone synaptic terminals couple electrically to their neighbors. This reduces the amplitude of temporally uncorrelated voltage differences between neighbors. For an achromatic stimulus coarser than the cone mosaic, the uncorrelated voltage difference between neighbors represents mostly noise; so noise is reduced more than the signal. Here coupling improves signal-to-noise ratio and enhances contrast sensitivity. But for a chromatic stimulus the uncorrelated voltage difference between neighbors of different spectral type represents mostly signal; so signal would be reduced more than the noise. This cost of cone coupling to encoding chromatic signals was evaluated using a compartmental model of the foveal cone array. When cones sensitive to middle (M) and long (L) wavelengths alternated regularly, and the conductance between a cone and all of its immediate neighbors was 1000 pS (∼2 connexons/cone pair), coupling reduced the difference between the L and M action spectra by nearly fivefold, from about 38% to 8%. However, L and M cones distribute randomly in the mosaic, forming small patches of like type, and within a patch the responses to a chromatic stimulus are correlated. In such a mosaic, coupling still reduced the difference between the L and M action spectra, but only by 2.4-fold, to about 18%. This result is independent of the L/M ratio. Thus “patchiness” of the L/M mosaic allows cone coupling to improve achromatic contrast sensitivity while minimizing the cost to chromatic sensitivity.