EREdmund Rose

Edmund Rose

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Edmund Rose has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of speed of sound for the assessment of cortical bone maturity

    by E. C. Rose, M. Hagenmüller, I. E. Jonas, B. A. Rahn

    Bone changes its structural and physical properties during maturation. In order to validate ultrasound measurements with regard to their usefulness in assessing cortical bone maturation, speed of sound (SOS) data were compared with mechanical properties (elastic modulus, bending strength, and cortical surface hardness), density and water content. Thirty pig mandibles were selected from three different age groups. Rectangular specimens of the buccal cortical bone of the body of the mandible were prepared. SOS was measured with pulsed ultrasound at a frequency of 2 MHz in all three dimensions, bone mineral density (BMD) by quantitative computed tomography, breaking strength and apparent elastic modulus in a three-point bending test to failure, water content using the lyophilization technique, and micro-indentation hardness using a modified Vickers' technique. While SOS in all three directions, BMD, surface hardness, and bending strength increased significantly (P < 0.001), bone tissue water content decreased significantly (P < 0.001) with age. Changes in the elastic modulus were not significant. Changes in SOS in the antero-posterior and apico-occlusal directions can be partly explained by BMD. In a bucco-lingual direction the increase is inadequately explained by the physical parameters investigated, and has possibly to be attributed to structural differences. Maturation of the mandible implies changes in its architectural organization, in material composition, and in the mechanical properties of cortical bone. In vitro SOS measurements reflect different structural and physical properties that are all age dependent. It thus seems feasible that age-related changes in bone maturation could be monitored by SOS measurements.


  • Occlusal and Skeletal Effects of an Oral Appliance in the Treatment of Obstructive Sleep Apnea

    by Edmund C. Rose, Richard Staats, Christian Virchow, Irmtrud E. Jonas


    • 1 September 2002
      • Vol. 33  (8) , 579-83

    Clinical comparison of a multistranded wire and a direct-bonded polyethylene ribbon-reinforced resin composite used for lingual retention.

    by Edmund Rose, Sibylle Frucht, Irmtrud E Jonas

    The reliability of posttreatment canine-to-canine retention with resin composite retainers reinforced with plasma-treated woven polyethylene ribbons was compared to the reliability of directly bonded, multistranded wire retainers. This prospective study was based on an assessment of 20 consecutive patients (eight women and 12 men with a mean age of 22.4 years) who required a fixed canine-to-canine retainer after undergoing orthodontic treatment. The type of retainer used was randomized for each patient. A follow-up examination was carried out once every 3 months. The length of time the retainers stayed in place without resin fracture or loosening from the teeth at one or more points was evaluated. The study's endpoint was 24 months after the retainer had been bonded. The ribbon-reinforced retainer remained in place for an average of 11.5 months, and the multistranded wire for a mean of 23.6 months. The difference was statistically significant. In terms of reliability for permanently fixed orthodontic retention from canine to canine, the direct-bonded multistranded wire is superior to the plasma-treated polyethylene woven ribbon and resin retainer.


  • Sleep-Related Obstructive Disordered Breathing in Cleft Palate Patients after Palatoplasty

    by Edmund Rose, Richard Staats, Ulrike Thissen, Jörg-Eland Otten, Rainer Schmelzeisen, Irmtrud Jonas

    Sleep-disordered breathing is frequently associated with children presenting congenital midface defects. Because of structural and functional anomalies in the upper airway, children with cleft palate, especially after surgery, may carry a higher risk of developing sleep-disordered breathing. However, the presence of such sleep-disordered breathing in older cleft palate children has not been emphasized. The aim of this comparative overnight cardiorespiratory sleep study was to evaluate cleft palate patients according to sleep-disordered breathing. A group of 43 cleft palate children (17 girls and 26 boys; mean age, 12.1 ± 3.8 years) was compared with a control group of 20 randomly selected, noncleft children matched for age, sex, and body mass index. None of the patients suffered from manifest sleep-disordered breathing. Cleft palate patients had a statistically significantly higher respiratory disturbance index and snoring index, but no increased apnea index. The data suggest that cleft palate patients having undergone primary closure of the palate demonstrate microsymptoms of nocturnal upper airway obstruction. (Plast. Reconstr. Surg. 110: 392, 2002.)


  • Treatment of obstructive sleep apnea with the Karwetzky oral appliance

    by Edmund Rose, Richard Staats, Jürgen Schulte‐Mönting, Irmtrud E. Jonas

    The aims of this retrospective study were to assess the effect of a Karwetzky mandibular protrusion appliance for treating patients with mild, moderate, and severe obstructive sleep apnea. Eighty‐one of 116 patients (69.8%) suffering from obstructive sleep apnea were treated with an activator model according to Karwetzky. After 4 months (SD 4.0 months) treatment outcome was controlled by polysomnography. Therapeutic outcome depended on the severity of obstructive sleep apnea. The median apnea‐hypopnea index decreased from 10.6 events/h (range 2.0–14.9) to 5.8 events/h (range 0.2–17.3, PPP<0.001) in the severe group. Sleep variables did not show consistent improvement except for a trend towards more REM sleep and slow‐wave sleep. The numbers of retentive teeth did not statistically influence treatment efficacy. Comparing the pre‐ and post‐treatment polysomnographic variables, it was found that the respiratory events rather than sleep stages were significantly reduced by the Karwetzky appliance investigated.


  • Cephalometric Analysis in Patients with Obstructive Sleep Apnea¶Part I: Diagnostic Value

    by Edmund C. Rose, Richard Staats, Martin Lehner, Irmtrud E. Jonas

    Background: Morphological soft-tissue and skeletal anomalies of the upper extrathoracic airways are considered to be an etiological cofactor of nocturnal obstructive respiratory disorders. Patients and Method: In this study 106 patients with a mean age of 56.1±8.4 years and a polysomnographic diagnosis of obstructive sleep apnea (OSA) were evaluated roentgenocephalometrically for soft-tissue and skeletal anomalies. Using cluster analysis and multivariate regression analysis, 18 skeletal variables, six pharyngeal variables and five hyoid variables were evaluated as predictor variables under the criterion variable “severity of the disorder”. The body mass index (BMI), as a recognized risk factor of OSA, was taken separately into account. Results: No direct correlation was found between the skeletal cephalometric findings and severity of OSA. Only the position of the hyoid as an expression of a probably adaptive alteration to a changed head posture and tongue position was found to be a significant parameter correlating with the severity of OSA. Conclusion: Whether cephalometric radiography is of direct diagnostic relevance in the diagnosis of OSA seems questionable in the light of the results of the present study. Hintergrund: Morphologische Weichteil- und Skelettauffälligkeiten der oberen extrathorakalen Luftwege werden als ein Kofaktor in der Ätiologie von nächtlichen obstruktiven Atemstörungen angesehen. Patienten und Methode: In dieser Studie wurden 106 Patienten im durchschnittlichen Alter von 56,1±8,4 Jahren mit der polysomnographisch gestellten Diagnose einer obstruktiven Schlafapnoe (OSA) röntgenkephalometrisch auf das Vorliegen von Weichteil- und Skelettanomalien untersucht. In einer Cluster-Analsyse und einer multivariaten Regressionsanalyse wurden unter der Kriteriumsvariable des Schweregrades der Erkrankung 18 skelettale Variable, sechs Variable aus der Analyse des Pharynx und fünf Variable aus der Analyse des Hyoids als Prädikatorvariable ausgewertet. Der Bodymass-Index (BMI) als ein anerkannter auslösender Faktor der OSA wurde gesondert berücksichtigt. Ergebnisse: Ein eindeutiger Rückschluss von skelettalen kephalometrischen Befunden auf den Ausprägungsgrad der OSA konnte nicht gefunden werden. Lediglich die Stellung des Hyoids, als Ausdruck einer wahrscheinlich adaptativen Position auf eine veränderte Kopfhaltung und Zungenlage, bildet einen signifikanten Parameter, der mit dem Schweregrad der Erkrankung in Beziehung steht. Schlussfolgerung: Eine Indikation für eine Fernröntgenseitenaufnahme des Schädels zur Diagnostik der OSA erscheint aufgrund des Ergebnisses der Untersuchung unter dem Akspekt der unmittelbaren diagnostischen Relevanz fragwürdig.


  • Intraorale Protrusionsgeräte bei schlafbezogenen obstruktiven Atmungsstörungen

    by E. Rose, G. J. Ridder, R. Staats, I. E. Jonas


  • Occlusal side effects caused by a mandibular advancement appliance in patients with obstructive sleep apnea.

    by E C Rose, C Schnegelsberg, R Staats, I E Jonas

    Mandibular advancement appliances (MAA) have been established as an alternative treatment option for obstructive sleep apnea (OSA). Although the therapeutic effect of these devices has been proven both clinically and polysomnographically through various studies, there are very few follow-up examinations in existence concerning possible dental side effects caused by the MAA. However, if lifelong treatment of OSA is considered, these follow-up examinations are of utmost importance. This article presents 2 cases with unexpected dental side effects and occlusal alterations caused by MAA therapy.