RWRyuichi Waseda

Ryuichi Waseda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ryuichi Waseda has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 June 2012
      • Vol. 65  (6) , 456-60

    [Total port-access robot-assisted lobectomy for lung cancer].

    by Yusuke Tanaka, Makoto Oda, Isao Matsumoto, Masaya Takizawa, Ryuichi Waseda, Nobuyoshi Tanaka, Mari Shimada, Norihiko Ishikawa, Go Watanabe

    We reported 2 cases of total port-access right lower lobectomy with hilar and mediastinal lymph nodal dissection using the da Vinci surgical system through subcostal trans-diaphragmatic approach. In case 1, the operating time was 6 hours 00 minutes, and the total blood loss was little. In case 2, the operating time was 6 hours 30 minutes, and the total blood loss was little. The da Vinci surgical system provides a high-resolution stereoscopic image and allows remote, tremor-free, and scaled control of endoscopic surgical instruments with 7 degrees of freedom. Minimally invasive robot-assisted lobectomy is an effective procedure and may add benefits for both surgeon and patients.


    • 1 May 2012
      • Vol. 39  (5) , 797-9

    [Rapid multidisciplinary therapy for an advanced lung cancer patient with severe tracheal stenosis resulting in long-term survival].

    by Mari Shimada, Isao Matsumoto, Yusuke Tanaka, Nobuyoshi Tanaka, Ryuichi Waseda, Masaya Takizawa, Makoto Oda, Go Watanabe, Kazuo Kasahara

    A 61-year-old female was admitted to our hospital due to dyspnea and facial edema. A chest CT scan showed stenosis of the trachea and superior vena cava due to a tumor around the trachea. She underwent partial resection of the tracheal tumor via a rigid bronchoscope introduced into the trachea, and placement of a Dumon Y-stent. Undifferentiated non-small cell lung cancer was diagnosed. After airway management, she underwent cisplatin-based chemoradiotherapy and total 56 Gy stereotactic radiotherapy for the tumor. The tumor size was reduced by 40% immediately after chemoradiotherapy. Six months after the tracheal stent insertion, bone metastases were pointed out, and we changed the chemotherapy regimen to gefitinib. She has been in good condition without tumor growth for more than six years after tracheal stent insertion.


  • A Case of Thymic Non-papillary Adenocarcinoma

    by Nobuyoshi Tanaka, Isao Matsumoto, Makoto Oda, Masaya Takizawa, Ryuichi Waseda, Go Watanabe

    Background. Thymic cancer is an uncommon neoplasm. In particular, thymic non-papillary adenocarcinoma is extremely rare. Case. A 61-year-old woman was referred to our hospital because of an anterior mediastinal tumor, which was found by coronary artery computed tomography for examination of abnormal electrocardiogram findings. The tumor was suspected to be thymoma or thymic cancer. She underwent endoscopic thymectomy using an automatic sternal lifting system. Histopathological findings showed thymic non-papillary adenocarcinoma, pT2N1M0, stage III, and Masaoka stage IVb. She underwent adjuvant chemotherapy. At 5 months after the surgery, chest CT revealed metastasis of the parasternal lymph node, and she underwent thoracoscopic lymph node resection. She is in good health without any tumor recurrence at 8 months after the initial surgery. Conclusion. We reported a case of thymic non-papillary adenocarcinoma of the anterior mediastinum. © 2012 The Japan Lung Cancer Society


  • U-clip for airway reconstruction: an experimental study of the feasibility of a robot-assisted endoscopic procedure

    by Ryuichi Waseda, Makoto Oda, Isao Matsumoto, Masaya Takizawa, Norihiko Ishikawa, Nobuyoshi Tanaka, Mari Shimada, Yusuke Tanaka, Go Watanabe

    The U-clip anastomotic device was developed to facilitate interrupted anastomoses without the need to tie sutures. Recently, this technology has been expanded into various fields of surgery. However, in the field of airway reconstruction, there have been no previous reports of this technology being used. The present study examined the technical feasibility of performing safe and efficient robot-assisted endoscopic airway reconstruction using nitinol U-clips in rabbits. A total of six tracheal anastomoses with S60 U-clips were performed using the da Vinci Surgical System. Anastomosis time and complications were recorded. The effectiveness of anastomoses was evaluated by postoperative observation of rabbits for 8 weeks and measurement of anastomotic strictures and pathological findings. All procedures were completed safely. Mean procedure time was 14 ± 1.8 min (mean ± SD). There were no perioperative complications; however, all animals died between postoperative days 14-27, and anastomotic stricture was the likely cause of death. All anastomoses had severe strictures; the mean stricture rate was measured as being 51.1 ± 33.3 (%). Although the technical feasibility of robot-assisted endoscopic airway reconstruction using U-clips has been demonstrated in rabbits, the safety of this technique has not been evaluated. Our data suggest that U-clips are not a feasible approach for airway reconstruction surgery because of the occurrence of severe postoperative anastomotic stricture.

    • 1 October 2010
      • Vol. 30  (10) , 4109-14

    Vitamin B2 as a tracer for intraoperative pulmonary sentinel node navigation surgery.

    by Isao Matsumoto, Yasuhiko Ohta, Ryuichi Waseda, Masaya Tamura, Makoto Oda, Go Watanabe

    We investigated whether fluorescent agents, especially vitamin B2, can act as tracers for intraoperative pulmonary sentinel node mapping. Vitamin B2, fluorescent beads, and green fluorescent protein (GFP) were each injected into pulmonary parenchyma in 4 pigs (experiment 1). The safety of each tracer was also verified in 12 rats (experiment 2). Experiment 1: In all groups, the sentinel lymph node was identified in 3 out of the 4 pigs (75%). Speed of agent dispersion: vitamin B2>GFP >fluorescent beads. Level of fluorescence judged as: vitamin B2>GFP=fluorescent beads. Experiment 2: In all groups, all rats survived until sacrifice without complications. In the fluorescent beads group, the fluorescent beads remained in the blood vessels. Vitamin B2 is inexpensive, safe and easy to apply. It is anticipated that clinical application of vitamin B2 for intraoperative pulmonary sentinel node mapping will become possible.