CNCraig Neville

Craig Neville

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Craig Neville has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Joseph P. Vacanti

    Department of Surgery, Massachusetts General Hospital, Boston, Massachusetts, 02114

    4 shared publications
  • Amedeo Carraro

    2 shared publications
  • Cathryn A. Sundback

    Center for Regenerative Medicine, Massachusetts General Hospital, Boston, Massachusetts, 02114

    2 shared publications
  • Cathryn A. Sundback

    Harvard Medical School, 25 Shattuck St, Boston, MA, 02115, United States; Center for Regenerative Medicine, Massachusetts General Hospital,185 Cambridge Street, Boston, MA, 02114, United States; Department of Surgery, Massachusetts General Hospital,55 Fruit Street, Boston, MA, 02114, United States

    2 shared publications
  • Irina Pomerantseva

    Center for Regenerative Medicine, Massachusetts General Hospital, Boston, Massachusetts, 02114

    2 shared publications
  • Jeffrey T. Borenstein

    2 shared publications

Latest Publications

  • Sustained intrathecal therapeutic protein delivery using genetically transduced tissue implants in a freely moving rat model

    by J.P. Aronson, H.A. Katnani, I. Pomerantseva, N. Shapir, H. Tse, R. Miari, H. Goltsman, O. Mwizerwa, C.M. Neville, G.A. Neil, et al.


  • Ear-Shaped Stable Auricular Cartilage Engineered from Extensively Expanded Chondrocytes in an Immunocompetent Experimental Animal Model

    by Irina Pomerantseva, David A. Bichara, Alan Tseng, Michael J. Cronce, Thomas M. Cervantes, Anya M. Kimura, Craig M. Neville, Nick Roscioli, Joseph P. Vacanti, Mark A. Randolph, et al.

    Advancement of engineered ear into clinical practice is limited by several challenges. The complex, largely unsupported three-dimensional auricular neocartilage structure is difficult to maintain. Neocartilage formation is challenging in an immunocompetent host due to active inflammatory and immunological responses. The large number of autologous chondrogenic cells required for engineering an adult human-sized ear presents an additional challenge because primary chondrocytes rapidly dedifferentiate during in vitro culture. The objective of this study was to engineer stable human ear-shaped cartilage in an immunocompetent animal model using expanded chondrocytes. The impact of basic fibroblast growth factor (bFGF) supplementation on achieving clinically relevant expansion of primary sheep chondrocytes by in vitro culture was determined. Chondrocytes expanded in standard medium were either combined with cryopreserved primary passage 0 chondrocytes at the time of scaffold seeding or used alone, as control. Disk and human ear-shaped scaffolds were made from porous collagen; ear scaffolds had an embedded supporting titanium wire framework. Autologous chondrocyte-seeded scaffolds were implanted subcutaneously in sheep after 2 weeks of in vitro incubation. The quality of the resulting neocartilage, its stability and retention of the original ear size and shape were evaluated at 6, 12, and 20 weeks post implantation. Neocartilage produced from chondrocytes expanded in the presence of bFGF was superior and its quality improved with increased implantation time. In addition to characteristic morphological cartilage features, its glycosaminoglycan content was high and marked elastin fiber formation was present. The overall shape of engineered ears was preserved at 20 weeks post implantation and the dimensional changes did not exceed 10%. The wire frame within the engineered ear was able to withstand mechanical forces during wound healing and neocartilage maturation and prevented shrinkage and distortion. This is the first demonstration of stable ear-shaped elastic cartilage engineered from auricular chondrocytes that underwent clinical-scale expansion, in an immunocompetent animal over an extended period of time.


  • In vitroevaluation of decellularized ECM-derived surgical scaffold biomaterials

    by Xiao Luo, Katherine M. Kulig, Eric B. Finkelstein, Margaret F. Nicholson, Xiang-Hong Liu, Scott M. Goldman, Joseph P. Vacanti, Brian E. Grottkau, Irina Pomerantseva, Cathryn A. Sundback, et al.

    Decellularized extracellular matrix (ECM) biomaterials are increasingly used in regenerative medicine for abdominal tissue repair. Emerging ECM biomaterials with greater compliance target surgical procedures like breast and craniofacial reconstruction to enhance aesthetic outcome. Clinical studies report improved outcomes with newly designed ECM scaffolds, but their comparative biological characteristics have received less attention. In this study, we investigated scaffolds derived from dermis (AlloDerm Regenerative Tissue Matrix), small intestinal submucosa (Surgisis 4-layer Tissue Graft and OASIS Wound Matrix), and mesothelium (Meso BioMatrix Surgical Mesh and Veritas Collagen Matrix) and evaluated biological properties that modulate cellular responses and recruitment. An assay panel was utilized to assess the ECM scaffold effects upon cells. Results of the material-conditioned media study demonstrated Meso BioMatrix and OASIS best supported cell proliferation. Meso BioMatrix promoted the greatest migration and chemotaxis signaling, followed by Veritas and OASIS; OASIS had superior suppression of cell apoptosis. The direct adhesion assay indicated that AlloDerm, Meso BioMatrix, Surgisis, and Veritas had sidedness that affected cell-material interactions. In the chick chorioallantoic membrane assay, Meso BioMatrix and OASIS best supported cell infiltration. Among tested materials, Meso BioMatrix and OASIS demonstrated characteristics that facilitate scaffold incorporation, making them promising choices for many clinical applications. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 585–593, 2017.


  • Liver-Assist Device With a Microfluidics-Based Vascular Bed in an Animal Model

    by Wen-Ming Hsu, Amedeo Carraro, Katherine M. Ba Kulig, Mark L. Miller, Mohammad Kaazempur-Mofrad, Eli Ba Weinberg, Fateh Entabi, Hassan Albadawi, Michael T. Watkins, Jeffrey T. Borenstein, et al.

    Objective: This study evaluates a novel liver-assist device platform with a microfluidics-modeled vascular network in a femoral arteriovenous shunt in rats. Summary of Background Data: Liver-assist devices in clinical trials that use pumps to force separated plasma through packed beds of parenchymal cells exhibited significant necrosis with a negative impact on function. Methods: Microelectromechanical systems technology was used to design and fabricate a liver-assist device with a vascular network that supports a hepatic parenchymal compartment through a nanoporous membrane. Sixteen devices with rat primary hepatocytes and 12 with human HepG2/C3A cells were tested in athymic rats in a femoral arteriovenous shunt model. Several parenchymal tube configurations were evaluated for pressure profile and cell survival. The blood flow pattern and perfusion status of the devices was examined by laser Doppler scanning. Cell viability and serum protein secretion functions were assessed. Results: Femoral arteriovenous shunt was successfully established in all animals. Blood flow was homogeneous through the vascular bed and replicated native flow patterns. Survival of seeded liver cells was highly dependent on parenchymal chamber pressures. The tube configuration that generated the lowest pressure supported excellent cell survival and function. Conclusions: This device is the first to incorporate a microfluidics network in the systemic circulatory system. The microvascular network supported viability and function of liver cells in a short-term ex vivo model. Parenchymal chamber pressure generated in an arteriovenous shunt model is a critical parameter that affects viability and must be considered in future designs. The microfluidics-based vascular network is a promising platform for generating a large-scale medical device capable of augmenting liver function in a clinical setting.


  • Engineered vascularized bone grafts

    by Olga Tsigkou, Irina Pomerantseva, Joel A. Spencer, Patricia A. Redondo, Alison R. Hart, Elisabeth O’dOherty, Yunfeng Lin, Claudia C. Friedrich, Laurence Daheron, Charles P. Lin, et al.

    Clinical protocols utilize bone marrow to seed synthetic and decellularized allogeneic bone grafts for enhancement of scaffold remodeling and fusion. Marrow-derived cytokines induce host neovascularization at the graft surface, but hypoxic conditions cause cell death at the core. Addition of cellular components that generate an extensive primitive plexus-like vascular network that would perfuse the entire scaffold upon anastomosis could potentially yield significantly higher-quality grafts. We used a mouse model to develop a two-stage protocol for generating vascularized bone grafts using mesenchymal stem cells (hMSCs) from human bone marrow and umbilical cord-derived endothelial cells. The endothelial cells formed tube-like structures and subsequently networks throughout the bone scaffold 4–7 days after implantation. hMSCs were essential for stable vasculature both in vitro and in vivo; however, contrary to expectations, vasculature derived from hMSCs briefly cultured in medium designed to maintain a proliferative, nondifferentiated state was more extensive and stable than that with hMSCs with a TGF-β-induced smooth muscle cell phenotype. Anastomosis occurred by day 11, with most hMSCs associating closely with the network. Although initially immature and highly permeable, at 4 weeks the network was mature. Initiation of scaffold mineralization had also occurred by this period. Some human-derived vessels were still present at 5 months, but the majority of the graft vasculature had been functionally remodeled with host cells. In conclusion, clinically relevant progenitor sources for pericytes and endothelial cells can serve to generate highly functional microvascular networks for tissue engineered bone grafts.


  • In vitro analysis of a hepatic device with intrinsic microvascular-based channels

    by Amedeo Carraro, Wen-Ming Hsu, Katherine M. Kulig, Wing S. Cheung, Mark L. Miller, Eli J. Weinberg, Eric F. Swart, Mohammad Kaazempur-Mofrad, Jeffrey T. Borenstein, Joseph P. Vacanti, et al.

    A novel microfluidics-based bilayer device with a discrete parenchymal chamber modeled upon hepatic organ architecture is described. The microfluidics network was designed using computational models to provide appropriate flow behavior based on physiological data from human microvasculature. Patterned silicon wafer molds were used to generate films with the vascular-based microfluidics network design and parenchymal chamber by soft lithography. The assembled device harbors hepatocytes behind a nanoporous membrane that permits transport of metabolites and small proteins while protecting them from the effects of shear stress. The device can sustain both human hepatoma cells and primary rat hepatocytes by continuous in vitro perfusion of medium, allowing proliferation and maintaining hepatic functions such as serum protein synthesis and metabolism. The design and fabrication processes are scalable, enabling the device concept to serve as both a platform technology for drug discovery and toxicity, and for the continuing development of an improved liver-assist device.