WRWilliam O. Richards

William O. Richards

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William O. Richards has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Surface Current Density Mapping for Identification of Gastric Slow Wave Propagation

    by L. Alan Bradshaw, Leo K. Cheng, William O. Richards, Andrew J. Pullan

    The magnetogastrogram (MGG) records clinically relevant parameters of the electrical slow wave of the stomach noninvasively. Besides slow wave frequency, gastric slow wave propagation velocity is a potentially useful clinical indicator of the state of health of gastric tissue, but it is a difficult parameter to determine from noninvasive bioelectric or biomagnetic measurements. We present a method for computing the surface current density from multichannel MGG recordings that allows computation of the propagation velocity of the gastric slow wave. A moving dipole source model with hypothetical as well as realistic biomagnetometer parameters demonstrates that while a relatively sparse array of magnetometer sensors is sufficient to compute a single average propagation velocity, more detailed information about spatial variations in propagation velocity requires higher density magnetometer arrays. Finally, the method is validated with simultaneous MGG and serosal electromyography measurements in a porcine subject.


  • W1289 Partial Mesenteric Ischemia Alters Biomagnetic Slow Wave

    by Adam Goodale, Chike B. Obioha, Jon Erickson, Andrei Irimia, Brandon Williams, Leonard A. Bradshaw, William O. Richards


  • A comparison of 399 open and 568 laparoscopic gastric bypasses performed during a 4-year period

    by N. Sekhar, A. Torquati, Y. Youssef, J. K. Wright, W. O. Richards

    Laparoscopic Roux-en-Y gastric bypass surgery (RYGB) was introduced at the authors’ institution 5 years ago. The authors analyzed the short- and long-term results of this procedure compared with those for the same procedure using the laparotomy approach over the same period. Retrospective analysis of a prospectively collected bariatric database used the outcome end points used by the American Society of Bariatric Surgery (ASBS) and the American College of Surgeons (ACS) in their center of excellence programs. From January 2001 to July 2005, 568 laparoscopic and 399 open gastric bypasses were performed at Vanderbilt University. The patients were from the same bariatric surgery program and therefore received the same pre- and postoperative care. The hospital length of stay in the laparoscopic group was significantly shorter (2.5 ± 2.4 days) than in the open group (3.7 ± 3.7 days; p = 0.001). The procedure time was significantly shorter in the laparoscopic group (164 ± 50 min) than in the open group (195 ± 50 min; p = 0.0001). The follow-up assessment response at 2 years was 76.6%. At 2 years, the excess weight loss (EWL) was significantly greater in the laparoscopic group (71.3% ± 18.4%) than in the open group (67.3% ± 15.3%; p = 0.03). The wound infection rate was significantly higher in open group (9.2%) than in the laparoscopic group (1.7%; p = 0.001). There was no significant difference in 30-day mortality: open (0.50%) versus laparoscopic (0.17%; p = 0.371). There was no significant difference in the 30-day reoperation rate between the open (2.4%) and laparoscopic (2.6%; p = 0.705) groups. The 30-day readmission rate was similar in the open (5.0%) and laparoscopic (5.2%; p = 0.852) groups, as was the rate of leakage from the gastrojejunostomy in the open (0.50%) and laparoscopic (0.35%; p = 0.127) groups. The conversion rate from laparoscopic procedure to laparotomy was 1.7%. In the authors’ institution, a laparoscopic bariatric surgery program with a very low rate of morbidity and mortality has been introduced. Operative time, hospital stay, and wound complications are reduced with the laparoscopic approach. The laparoscopic and open procedures are equally safe, with equivalent 30-day mortality, readmission, reoperation, and gastrojejunostomy leakage rates.


  • Separation of gastric electrical control activity from simultaneous MGG/EGG recordings using independent component analysis

    by Andrei Irimia, Michael R. Gallucci, William O. Richards, L. Alan Bradshaw

    Spatiotemporal parameters of gastric electrical control activity such as its amplitude, direction and propagation velocity are physiological parameters of distinctive clinical interest due to their potential use for differentiating between the healthy and diseased states of the human stomach. Whereas their time evolution is relatively well behaved in the case of healthy subjects, significant deviations from normal have been observed in patients suffering from a number of gastric diseases such as gastroparesis and gastropathy. For this reason, monitoring ECA parameters noninvasively may offer a useful test for the presence of such diseases whose diagnosis remains problematic. Here, we describe a method for computing ECA direction and orientation from simultaneous, noninvasive magnetogastrographic (MGG) and electrogastrographic (EGG) recordings. We demonstrate how independent component analysis and standard frequency analysis methods can be used to predict the locations and orientations of gastric current dipoles from MGG/EGG data. We compare our MGG-based dipole parameters to analogous ones obtained from simultaneous EGG recordings within the experimental framework of a human model. We find that magnetic recordings are superior in their ability to portray the underlying physiology of the stomach


  • Separation of gastric electrical control activity from simultaneous MGG/EGG recordings using independent component analysis

    by Andrei Irimia, Michael R. Gallucci, William O. Richards, L. Alan Bradshaw

    Spatiotemporal parameters of gastric electrical control activity such as its amplitude, direction and propagation velocity are physiological parameters of distinctive clinical interest due to their potential use for differentiating between the healthy and diseased states of the human stomach. Whereas their time evolution is relatively well behaved in the case of healthy subjects, significant deviations from normal have been observed in patients suffering from a number of gastric diseases such as gastroparesis and gastropathy. For this reason, monitoring ECA parameters noninvasively may offer a useful test for the presence of such diseases whose diagnosis remains problematic. Here, we describe a method for computing ECA direction and orientation from simultaneous, noninvasive magnetogastrographic (MGG) and electrogastrographic (EGG) recordings. We demonstrate how independent component analysis and standard frequency analysis methods can be used to predict the locations and orientations of gastric current dipoles from MGG/EGG data. We compare our MGG-based dipole parameters to analogous ones obtained from simultaneous EGG recordings within the experimental framework of a human model. We find that magnetic recordings are superior in their ability to portray the underlying physiology of the stomach

  • Magnetogastrographic detection of gastric electrical response activity in humans

    by Andrei Irimia, William O Richards, L Alan Bradshaw

    The detection and characterization of gastric electrical activity has important clinical applications, including the early diagnosis of gastric diseases in humans. In mammals, this phenomenon has two important features: an electrical control activity (ECA) that manifests itself as an electric slow wave (with a frequency of 3 cycles per minute in humans) and an electrical response activity (ERA) that is characterized by spiking potentials during the plateau phase of the ECA. Whereas the ECA has been recorded in humans both invasively and non-invasively (magnetogastrography-MGG), the ERA has never been detected non-invasively in humans before. In this paper, we report on our progress towards the non-invasive detection of ERA from the human stomach using a procedure that involves the application of principal component analysis to MGG recordings, which were acquired in our case from ten normal human patients using a Superconducting QUantum Interference Device (SQUID) magnetometer. Both pre- and post-prandial recordings were acquired for each patient and 20 min of recordings (10 min of pre-prandial and 10 min of post-prandial data) were analysed for each patient. The mean percentage of ECA slow waves that were found to exhibit spikes of suspected ERA origin was 41% and 61% for pre- and post-prandial recordings, respectively, implying a 47% ERA increase post-prandially (P < 0.0001 at a 95% confidence level). The detection of ERA in humans is highly encouraging and points to the possible use of non-invasive ERA recordings as a valuable tool for the study of human gastric disorders.


  • Endoscopic evaluation of the gastrojejunostomy in laparoscopic gastric bypass

    by N. Sekhar, A. Torquati, R. Lutfi, W. O. Richards