Takeshi Ohdaira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Takeshi Ohdaira has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Hideo Nagai
Department of General Surgery, Jichi Medical University, Tochigi, Japan
5 shared publicationsYoshikazu Yasuda
3 shared publicationsH. Nagai
Jichi Medical University
2 shared publicationsKazuhiro Endo
Jichi Medical University
2 shared publications- Masanobu Hyodo
Department of Surgery, School of Medicine, Jichi Medical University, Shimotsuke, Japan
2 shared publications Nozomi Abe
Jichi Medical University
2 shared publications
Latest Publications
- 1 April 2010
- Vol. 19, 38-46
Requisites for the remote-controlled wide-view CCD camera unit for natural orifice transluminal endoscopic surgery placed in the intraperitoneal cavity.
In natural orifice transluminal endoscopic surgery (NOTES) using a single endoscope, the visual field moves unstably and a wide blind space is formed. We used wireless two wireless CCD cameras (270,000 and 380,000 pixels) placed on the abdominal wall of pigs and a conventional endoscope (410,000 pixels) at the same time to assess whether it was possible to observe the entire process of sigmoidectomy by NOTES. The titanium dioxide-coated lens was used as an antifogging apparatus. To control the CCD image frames, a magnetic body was affixed to the back of the CCD camera unit. To select a suitable visual-transmitter, three frequency bands were assessed: 0.07 GHz, 1.2 GHz, and 2.4 GHz. The cameras showed good performance for monitoring all procedures of the sigmoidectomy. The magnetic force most suitable to control the cameras was found to be 360 mT, and the best transmission frequency was 1.2 GHz. The battery could be used for up to 4 hours with intermittent use. The issue of lens fogging could be resolved by a water supply into the anal canal and a more than 12-hour ultraviolet irradiation. We verified that the CCD camera with the titanium dioxide-coated lens may be useful as the second eye in NOTES.
- 1 April 2010
- Vol. 19, 38-46
Requisites for the remote-controlled wide-view CCD camera unit for natural orifice transluminal endoscopic surgery placed in the intraperitoneal cavity.
In natural orifice transluminal endoscopic surgery (NOTES) using a single endoscope, the visual field moves unstably and a wide blind space is formed. We used wireless two wireless CCD cameras (270,000 and 380,000 pixels) placed on the abdominal wall of pigs and a conventional endoscope (410,000 pixels) at the same time to assess whether it was possible to observe the entire process of sigmoidectomy by NOTES. The titanium dioxide-coated lens was used as an antifogging apparatus. To control the CCD image frames, a magnetic body was affixed to the back of the CCD camera unit. To select a suitable visual-transmitter, three frequency bands were assessed: 0.07 GHz, 1.2 GHz, and 2.4 GHz. The cameras showed good performance for monitoring all procedures of the sigmoidectomy. The magnetic force most suitable to control the cameras was found to be 360 mT, and the best transmission frequency was 1.2 GHz. The battery could be used for up to 4 hours with intermittent use. The issue of lens fogging could be resolved by a water supply into the anal canal and a more than 12-hour ultraviolet irradiation. We verified that the CCD camera with the titanium dioxide-coated lens may be useful as the second eye in NOTES.
- 18 June 2009
- Published by Springer Nature in Surgical Endoscopy
- Vol. 24 (1) , 198-209
Usefulness in NOTES of an intra-abdominal antifogging wireless charge-coupled device (CCD) camera with pantograph-type needle unit for placement to the intra-abdominal wall
In natural orifice transluminal endoscopic surgery (NOTES), the endoscope has the disadvantages of an unstable visual field and wide blind space. We developed a compact charge-coupled device (CCD) camera unit that can be transgastrointestinally placed in the abdominal cavity.
- 18 June 2009
- Published by Springer Nature in Surgical Endoscopy
- Vol. 24 (1) , 198-209
Usefulness in NOTES of an intra-abdominal antifogging wireless charge-coupled device (CCD) camera with pantograph-type needle unit for placement to the intra-abdominal wall
In natural orifice transluminal endoscopic surgery (NOTES), the endoscope has the disadvantages of an unstable visual field and wide blind space. We developed a compact charge-coupled device (CCD) camera unit that can be transgastrointestinally placed in the abdominal cavity.
- 11 April 2009
- Published by Springer Nature in Journal of Hepato-Biliary-Pancreatic Surgery
- Vol. 16 (3) , 274-282
Transintestinal hepatectomy performed by hybrid NOTES using a customized X-TRACT Tissue Morcellator with an electrifiable round cutter
- 11 April 2009
- Published by Springer Nature in Journal of Hepato-Biliary-Pancreatic Surgery
- Vol. 16 (3) , 274-282
Transintestinal hepatectomy performed by hybrid NOTES using a customized X-TRACT Tissue Morcellator with an electrifiable round cutter
- 26 March 2007
- Published by Wiley in Journal of Surgical Oncology
- Vol. 96 (1) , 46-53
Metastasis‐related factors expressed in pT1 pN0 breast cancer: Assessment of recurrence risk
Objectives Previous reports have indicated that small breast cancers without lymph node metastasis present a favorable prognosis. However, 10–20% of patients with T1 N0 invasive ductal carcinoma experience recurrence and have a poor prognosis. The objective of this study was to examine whether certain metastasis-related factors are prognostic of cancer recurrence in such patients at risk for relapse. Methods Nineteen patients with the carcinoma who had recurrence 1–15 years after margin-free resection were examined. The control group consisted of 20 patients with pT1 pN0 invasive ductal carcinoma who had no recurrence for ≥10 years after radical surgery. The two groups were compared with respect to clinical profiles, conventional neoplastic features, and immunohistochemical expressions of 16 metastasis-related factors. Results No significant difference was found between the two groups in clinical profiles and conventional neoplastic features. However, six factors (MMP-2, MT1-MMP, T1MP-2, VEGF, cMET, and PCNA) were significantly expressed in the recurrence group against the control group. MMP-9 was significantly less expressed in the recurrence group. Of these factors, MMP-2, MT1-MMP, and VEGF showed the highest adjusted odds ratios. Conclusion MMP family and growth factors may be promising predictors of recurrence risk of early stage breast cancer. J. Surg. Oncol. 2007;96:46–53.
- 26 March 2007
- Published by Wiley in Journal of Surgical Oncology
- Vol. 96 (1) , 46-53
Metastasis‐related factors expressed in pT1 pN0 breast cancer: Assessment of recurrence risk
Objectives Previous reports have indicated that small breast cancers without lymph node metastasis present a favorable prognosis. However, 10–20% of patients with T1 N0 invasive ductal carcinoma experience recurrence and have a poor prognosis. The objective of this study was to examine whether certain metastasis-related factors are prognostic of cancer recurrence in such patients at risk for relapse. Methods Nineteen patients with the carcinoma who had recurrence 1–15 years after margin-free resection were examined. The control group consisted of 20 patients with pT1 pN0 invasive ductal carcinoma who had no recurrence for ≥10 years after radical surgery. The two groups were compared with respect to clinical profiles, conventional neoplastic features, and immunohistochemical expressions of 16 metastasis-related factors. Results No significant difference was found between the two groups in clinical profiles and conventional neoplastic features. However, six factors (MMP-2, MT1-MMP, T1MP-2, VEGF, cMET, and PCNA) were significantly expressed in the recurrence group against the control group. MMP-9 was significantly less expressed in the recurrence group. Of these factors, MMP-2, MT1-MMP, and VEGF showed the highest adjusted odds ratios. Conclusion MMP family and growth factors may be promising predictors of recurrence risk of early stage breast cancer. J. Surg. Oncol. 2007;96:46–53.
- 6 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (5) , 810-815
Intraoperative localization of early-stage upper gastrointestinal tumors using a magnetic marking clip–detecting system
Intraoperative tumor localization often is difficult during laparoscopic surgery for early-stage upper gastrointestinal tumors.
- 6 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (5) , 810-815
Intraoperative localization of early-stage upper gastrointestinal tumors using a magnetic marking clip–detecting system
Intraoperative tumor localization often is difficult during laparoscopic surgery for early-stage upper gastrointestinal tumors.
- 1 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (2) , 333-338
Antifogging effects of a socket-type device with the superhydrophilic, titanium dioxide–coated glass for the laparoscope
Lens fogging during laparoscopic surgery extensively deteriorates operative field visibility and may provoke serious complications.
- 1 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (2) , 333-338
Antifogging effects of a socket-type device with the superhydrophilic, titanium dioxide–coated glass for the laparoscope
Lens fogging during laparoscopic surgery extensively deteriorates operative field visibility and may provoke serious complications.
- 1 January 2007
- Vol. 16, 66-71
Solid tumor resection by use of a highly sensitive micromagnetic needle detection system.
The objective of this study was to evaluate the efficiency of tumor detection in parenchymal organs and their resection by use of a micromagnetic needle detection system (MNDS). A micromagnetic needle (maximum magnetic flux density = 120 mT) and a micromagnetic needle-setting device were used. An in vitro laboratory study with a gumball within gelatin representing a tumor was conducted to calculate detection rates and to measure the time required for resection by MNDS. An animal study with the cervical lymph nodes of pigs representing tumors was conducted to measure the time required for lymph node resection. The removal rate of the target lymph node was 100% with MNDS. Results show that MNDS may be useful for tumor resection in the presence of air and for the resection of tumors that are difficult to detect by ultrasonography.
- 1 January 2007
- Vol. 16, 66-71
Solid tumor resection by use of a highly sensitive micromagnetic needle detection system.
The objective of this study was to evaluate the efficiency of tumor detection in parenchymal organs and their resection by use of a micromagnetic needle detection system (MNDS). A micromagnetic needle (maximum magnetic flux density = 120 mT) and a micromagnetic needle-setting device were used. An in vitro laboratory study with a gumball within gelatin representing a tumor was conducted to calculate detection rates and to measure the time required for resection by MNDS. An animal study with the cervical lymph nodes of pigs representing tumors was conducted to measure the time required for lymph node resection. The removal rate of the target lymph node was 100% with MNDS. Results show that MNDS may be useful for tumor resection in the presence of air and for the resection of tumors that are difficult to detect by ultrasonography.
- 20 December 2006
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (5) , 782-784
A vertical scanning Doppler probe identifies blood vessels during laparoscopic surgery
Using a conventional Doppler probe, it is difficult to identify blood vessels precisely in lymph node dissection during laparoscopic surgery. For 26 patients undergoing laparoscopic colectomy and 26 patients undergoing laparoscopic subtotal gastrectomy, we used conventional and vertical scanning Doppler probes to compare their ability to identify invisible blood vessels through differences in power output voltage. The vertical scanning Doppler probe was 100% successful in identifying the target blood vessels regardless of the patient’s body mass index (BMI), and also was superior to the conventional Doppler probe in detection sensitivity. The vertical scanning Doppler probe was useful for image training of recently qualified surgeons through real-time monitoring of the probe position and response on the monitor. Furthermore, findings showed that the vertical scanning Doppler probe was applicable to lymph node dissection as a forceps for laparoscopic usage. The vertical scanning Doppler could identify the target blood vessels regardless of the patient’s BMI. It was verified to be useful as a surgical assistive device apart from being a sensor and may serve in the education of recently qualified surgeons.
- 20 December 2006
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (5) , 782-784
A vertical scanning Doppler probe identifies blood vessels during laparoscopic surgery
Using a conventional Doppler probe, it is difficult to identify blood vessels precisely in lymph node dissection during laparoscopic surgery. For 26 patients undergoing laparoscopic colectomy and 26 patients undergoing laparoscopic subtotal gastrectomy, we used conventional and vertical scanning Doppler probes to compare their ability to identify invisible blood vessels through differences in power output voltage. The vertical scanning Doppler probe was 100% successful in identifying the target blood vessels regardless of the patient’s body mass index (BMI), and also was superior to the conventional Doppler probe in detection sensitivity. The vertical scanning Doppler probe was useful for image training of recently qualified surgeons through real-time monitoring of the probe position and response on the monitor. Furthermore, findings showed that the vertical scanning Doppler probe was applicable to lymph node dissection as a forceps for laparoscopic usage. The vertical scanning Doppler could identify the target blood vessels regardless of the patient’s BMI. It was verified to be useful as a surgical assistive device apart from being a sensor and may serve in the education of recently qualified surgeons.
- 9 July 2004
- Vol. 51 (58) , 1011-4
Gasless laparoscopy-assisted colon surgery utilizing mini-laparotomy and a subcutaneous abdominal wall lift system.
This study was performed to investigate the technical aspects and perioperative results of using a subcutaneous abdominal wall lift system for laparoscopy-assisted colectomy. We attempted a laparoscopy-assisted colectomy for 19 patients and completed 16 cases using mini-laparotomy and a subcutaneous abdominal wall lift system, observing monitor images via laparoscopy or direct views through mini-laparotomy. All 5 surgeons had no experience of laparoscopy-assisted colectomy but considerable experience of laparoscopic cholecystectomy. The operating time ranged from 120 to 360 minutes with an average of 188. Intraoperative blood loss ranged from 20 to 300 mL with an average of 116 mL. No postoperative major complications occurred, but 5 cases suffered wound infection. Laparoscopy-assisted colon surgery utilizing a subcutaneous abdominal wall system and mini-laparotomy was feasible as minimally invasive surgery for colorectal diseases, even for surgeons with little previous experience.
- 9 July 2004
- Vol. 51 (58) , 1011-4
Gasless laparoscopy-assisted colon surgery utilizing mini-laparotomy and a subcutaneous abdominal wall lift system.
This study was performed to investigate the technical aspects and perioperative results of using a subcutaneous abdominal wall lift system for laparoscopy-assisted colectomy. We attempted a laparoscopy-assisted colectomy for 19 patients and completed 16 cases using mini-laparotomy and a subcutaneous abdominal wall lift system, observing monitor images via laparoscopy or direct views through mini-laparotomy. All 5 surgeons had no experience of laparoscopy-assisted colectomy but considerable experience of laparoscopic cholecystectomy. The operating time ranged from 120 to 360 minutes with an average of 188. Intraoperative blood loss ranged from 20 to 300 mL with an average of 116 mL. No postoperative major complications occurred, but 5 cases suffered wound infection. Laparoscopy-assisted colon surgery utilizing a subcutaneous abdominal wall system and mini-laparotomy was feasible as minimally invasive surgery for colorectal diseases, even for surgeons with little previous experience.
- 1 March 2003
- Vol. 30 (3) , 399-402
[A case report of adjuvant chemotherapy (TS-1) for far advanced gastric cancer in which the patient maintained a good quality of life].
A 44-year-old male patient underwent total gastrectomy for gastric cancer with peritoneal dissemination and direct invasion into the pancreas. After the operation, the patient received daily oral administration of TS-1, a novel oral anticancer agent. Each treatment course consisted of four-week administration of 120 mg TS-1 daily followed by two drug-free weeks. The patient was confirmed to be cancer-free by abdominal CT from the eighth course. With this chemotherapy, slight decrease of WBC (grade 1 or 2) and mild bowel obstruction appeared as the side effects of TS-1, but no other serious effects were observed. (A dose reduction of TS-1 from 120 mg to 100 mg per day was done at the beginning of the fifth course.) This patient could return to his work (physical labor) in the sixth month after the operation. The cancer-free period has persisted for sixteen months since the operation, and a good quality of life has been maintained simultaneously. TS-1 revealed a high effectiveness without deteriorating the patient's quality of life.
- 1 March 2003
- Vol. 30 (3) , 399-402
[A case report of adjuvant chemotherapy (TS-1) for far advanced gastric cancer in which the patient maintained a good quality of life].
A 44-year-old male patient underwent total gastrectomy for gastric cancer with peritoneal dissemination and direct invasion into the pancreas. After the operation, the patient received daily oral administration of TS-1, a novel oral anticancer agent. Each treatment course consisted of four-week administration of 120 mg TS-1 daily followed by two drug-free weeks. The patient was confirmed to be cancer-free by abdominal CT from the eighth course. With this chemotherapy, slight decrease of WBC (grade 1 or 2) and mild bowel obstruction appeared as the side effects of TS-1, but no other serious effects were observed. (A dose reduction of TS-1 from 120 mg to 100 mg per day was done at the beginning of the fifth course.) This patient could return to his work (physical labor) in the sixth month after the operation. The cancer-free period has persisted for sixteen months since the operation, and a good quality of life has been maintained simultaneously. TS-1 revealed a high effectiveness without deteriorating the patient's quality of life.