Naoyuki Tanimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Naoyuki Tanimoto has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Mathias W. Seeliger
Division of Ocular Neurodegeneration, Institute for Ophthalmic Research, Centre for Ophthalmology, Eberhard Karls University, Schleichstr. 4/3, 72076, Tübingen, Germany
7 shared publicationsHaruki Abe
Niigata University
4 shared publicationsShigeru Hasegawa
Niigata University
4 shared publicationsTomoaki Usui
Niigata University
4 shared publicationsVithiyanjali Sothilingam
Division of Ocular Neurodegeneration, Institute for Ophthalmic Research, Centre for Ophthalmology, Eberhard Karls University, Schleichstr. 4/3, D-72076 Tübingen, Germany
4 shared publicationsMikio Ichibe
Niigata University
3 shared publications
Latest Publications
- 21 March 2016
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 132 (2) , 101-109
Differentiation of murine models of “negative ERG” by single and repetitive light stimuli
Purpose Marked attenuation of the single-flash electroretinographic (ERG) b-wave in the presence of a normal-amplitude or less-attenuated a-wave is commonly referred to as the “negative ERG.” The purpose of this study was to investigate whether the disparate origins of the negative ERG in three murine models can be discriminated using flickering stimuli. Methods Three models were selected: (1) the Nyx nob mouse model of complete congenital stationary night blindness, (2) the oxygen-induced retinopathy (OIR) rat model of retinopathy of prematurity (ROP), and (3) the Rs1 knockout (KO) mouse model of X-linked juvenile retinoschisis. Directly after a dark-adapted, single-flash ERG luminance series, a flicker ERG frequency series (0.5–30 Hz) was performed at a fixed luminance of 0.5 log cd s/m2. This series includes frequency ranges that are dominated by activity in (A) the rod pathways (below 5 Hz), (B) the cone ON-pathway (5–15 Hz), and (C) the cone OFF-pathway (above 15 Hz). Results All three models produced markedly attenuated single-flash ERG b-waves. In the Nyx nob mouse, which features postsynaptic deficits in the ON-pathways, the a-wave was normal and flicker responses were attenuated in ranges A and B, but not C. The ROP rat is characterized by inner-retinal ischemia which putatively affects both ON- and OFF-bipolar cell activity; flicker responses were reduced in all ranges (A–C). Notably, the choroid supplies the photoreceptors and is thought to be relatively intact in OIR, an idea supported by the nearly normal a-wave. Finally, in the Rs1 KO mouse, which has documented abnormality of the photoreceptor-bipolar synapse affecting both ON- and OFF-pathways, the flicker responses were attenuated in all ranges (A–C). The a-wave was also attenuated, likely as a consequence to schisms in the photoreceptor layer. Conclusion Consideration of both single-flash and flickering ERG responses can discriminate the functional pathology of the negative ERG in these animal models of human disease.
- 21 March 2016
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 132 (2) , 101-109
Differentiation of murine models of “negative ERG” by single and repetitive light stimuli
Purpose Marked attenuation of the single-flash electroretinographic (ERG) b-wave in the presence of a normal-amplitude or less-attenuated a-wave is commonly referred to as the “negative ERG.” The purpose of this study was to investigate whether the disparate origins of the negative ERG in three murine models can be discriminated using flickering stimuli. Methods Three models were selected: (1) the Nyx nob mouse model of complete congenital stationary night blindness, (2) the oxygen-induced retinopathy (OIR) rat model of retinopathy of prematurity (ROP), and (3) the Rs1 knockout (KO) mouse model of X-linked juvenile retinoschisis. Directly after a dark-adapted, single-flash ERG luminance series, a flicker ERG frequency series (0.5–30 Hz) was performed at a fixed luminance of 0.5 log cd s/m2. This series includes frequency ranges that are dominated by activity in (A) the rod pathways (below 5 Hz), (B) the cone ON-pathway (5–15 Hz), and (C) the cone OFF-pathway (above 15 Hz). Results All three models produced markedly attenuated single-flash ERG b-waves. In the Nyx nob mouse, which features postsynaptic deficits in the ON-pathways, the a-wave was normal and flicker responses were attenuated in ranges A and B, but not C. The ROP rat is characterized by inner-retinal ischemia which putatively affects both ON- and OFF-bipolar cell activity; flicker responses were reduced in all ranges (A–C). Notably, the choroid supplies the photoreceptors and is thought to be relatively intact in OIR, an idea supported by the nearly normal a-wave. Finally, in the Rs1 KO mouse, which has documented abnormality of the photoreceptor-bipolar synapse affecting both ON- and OFF-pathways, the flicker responses were attenuated in all ranges (A–C). The a-wave was also attenuated, likely as a consequence to schisms in the photoreceptor layer. Conclusion Consideration of both single-flash and flickering ERG responses can discriminate the functional pathology of the negative ERG in these animal models of human disease.
- 2 October 2015
- Published by Springer Nature
- Vol. 854, 619-625
In-Depth Functional Diagnostics of Mouse Models by Single-Flash and Flicker Electroretinograms without Adapting Background Illumination
Electroretinograms (ERGs) are commonly recorded at the cornea for an assessment of the functional status of the retina in mouse models. Full-field ERGs can be elicited by single-flash as well as flicker light stimulation although in most laboratories flicker ERGs are recorded much less frequently than singleflash ERGs. Whereas conventional single-flash ERGs contain information about layers, i.e., outer and inner retina, flicker ERGs permit functional assessment of the vertical pathways of the retina, i.e., rod system, cone ON-pathway, and cone OFF-pathway, when the responses are evoked at a relatively high luminance (0.5 log cd s/m2) with varying frequency (from 0.5 to 30 Hz) without any adapting background illumination. Therefore, both types of ERGs complement an in-depth functional characterization of the mouse retina, allowing for a discrimination of an underlying functional pathology. Here, we introduce the systematic interpretation of the single-flash and flicker ERGs by demonstrating several different patterns of functional phenotype in genetic mouse models, in which photoreceptors and/or bipolar cells are primarily or secondarily affected.
- 2 October 2015
- Published by Springer Nature
- Vol. 854, 619-625
In-Depth Functional Diagnostics of Mouse Models by Single-Flash and Flicker Electroretinograms without Adapting Background Illumination
Electroretinograms (ERGs) are commonly recorded at the cornea for an assessment of the functional status of the retina in mouse models. Full-field ERGs can be elicited by single-flash as well as flicker light stimulation although in most laboratories flicker ERGs are recorded much less frequently than singleflash ERGs. Whereas conventional single-flash ERGs contain information about layers, i.e., outer and inner retina, flicker ERGs permit functional assessment of the vertical pathways of the retina, i.e., rod system, cone ON-pathway, and cone OFF-pathway, when the responses are evoked at a relatively high luminance (0.5 log cd s/m2) with varying frequency (from 0.5 to 30 Hz) without any adapting background illumination. Therefore, both types of ERGs complement an in-depth functional characterization of the mouse retina, allowing for a discrimination of an underlying functional pathology. Here, we introduce the systematic interpretation of the single-flash and flicker ERGs by demonstrating several different patterns of functional phenotype in genetic mouse models, in which photoreceptors and/or bipolar cells are primarily or secondarily affected.
- Open Access
- 1 June 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 10731
Electroretinographic assessment of rod- and cone-mediated bipolar cell pathways using flicker stimuli in mice
Mouse full-field electroretinograms (ERGs) are dominated by responses of photoreceptors and depolarizing (ON-) bipolar cells, but not much of hyperpolarizing (OFF-) bipolar cells under conventional recording conditions. Here we investigate a novel ERG protocol in mice for functional assessment of the major ON- and OFF-bipolar cell pathways using flicker stimuli for a high luminance with varying frequency up to 30 Hz. Wild-type (WT) and functionally specific transgenic mice (Cnga3-/-, no cone photoreceptor function; rho-/-, no rod photoreceptor function; mGluR6-/-, no ON-bipolar cell function) were examined. The Cnga3-/- flicker ERG was similar to the WT flicker ERG at very low stimulus frequencies, whereas ERGs were comparable between WT and rho-/- mice at 5 Hz and above. Between 5 and 15 Hz, ERGs in mGluR6-/- mice differed in configuration and amplitude from those in WT and rho-/- mice; in contrast, response amplitudes above 15 Hz were comparable among WT, rho-/- and mGluR6-/- mice. In summary, we found three frequency ranges with these conditions that are dominated by activity in the rod pathways (below 5 Hz), cone ON-pathway (between 5 and 15 Hz) and cone OFF-pathway (above 15 Hz) that enables a quick overview of the functionality of the major bipolar cell pathways.
- 1 June 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 10731
Open AccessElectroretinographic assessment of rod- and cone-mediated bipolar cell pathways using flicker stimuli in mice
Mouse full-field electroretinograms (ERGs) are dominated by responses of photoreceptors and depolarizing (ON-) bipolar cells, but not much of hyperpolarizing (OFF-) bipolar cells under conventional recording conditions. Here we investigate a novel ERG protocol in mice for functional assessment of the major ON- and OFF-bipolar cell pathways using flicker stimuli for a high luminance with varying frequency up to 30 Hz. Wild-type (WT) and functionally specific transgenic mice (Cnga3-/-, no cone photoreceptor function; rho-/-, no rod photoreceptor function; mGluR6-/-, no ON-bipolar cell function) were examined. The Cnga3-/- flicker ERG was similar to the WT flicker ERG at very low stimulus frequencies, whereas ERGs were comparable between WT and rho-/- mice at 5 Hz and above. Between 5 and 15 Hz, ERGs in mGluR6-/- mice differed in configuration and amplitude from those in WT and rho-/- mice; in contrast, response amplitudes above 15 Hz were comparable among WT, rho-/- and mGluR6-/- mice. In summary, we found three frequency ranges with these conditions that are dominated by activity in the rod pathways (below 5 Hz), cone ON-pathway (between 5 and 15 Hz) and cone OFF-pathway (above 15 Hz) that enables a quick overview of the functionality of the major bipolar cell pathways.
- 13 November 2013
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 128 (1) , 25-32
Auditory event-related signals in mouse ERG recordings
- 13 November 2013
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 128 (1) , 25-32
Auditory event-related signals in mouse ERG recordings
- Open Access
- 12 October 2012
- Published by Oxford University Press (OUP) in Human Molecular Genetics
- Vol. 21 (24) , 5395
In conditions of limited chromophore supply rods entrap 11-cis-retinal leading to loss of cone function and cell death
- 12 October 2012
- Published by Oxford University Press (OUP) in Human Molecular Genetics
- Vol. 21 (24) , 5395
Open AccessIn conditions of limited chromophore supply rods entrap 11-cis-retinal leading to loss of cone function and cell death
- 22 September 2012
- Published by Springer Nature
- Vol. 935, 69-78
Functional Phenotyping of Mouse Models with ERG
In many situations it is important to be able to assess the degree of retinal function, e.g., for the characterization of mouse models with unknown retinal involvement, when studying degenerative processes, for the analysis of visual signal processing, and during the follow-up of therapeutic interventions. Full-field electroretinography (ERG), yielding a sum response of event-related transient electrical activity of the entire retina to light stimulation, is widely applied in human as well as experimental functional diagnostics. ERG examinations normally include initial dark-adapted (scotopic) measurements that enable rod-driven activity to be studied, followed by light-adapted (photopic) recordings to obtain information about cone system contributions. The results allow the correlation of acute or long-term disease-related changes or their alleviation by therapy with morphological data, in order to obtain a comprehensive understanding of the underlying processes and mechanisms.
- 22 September 2012
- Published by Springer Nature
- Vol. 935, 69-78
Functional Phenotyping of Mouse Models with ERG
In many situations it is important to be able to assess the degree of retinal function, e.g., for the characterization of mouse models with unknown retinal involvement, when studying degenerative processes, for the analysis of visual signal processing, and during the follow-up of therapeutic interventions. Full-field electroretinography (ERG), yielding a sum response of event-related transient electrical activity of the entire retina to light stimulation, is widely applied in human as well as experimental functional diagnostics. ERG examinations normally include initial dark-adapted (scotopic) measurements that enable rod-driven activity to be studied, followed by light-adapted (photopic) recordings to obtain information about cone system contributions. The results allow the correlation of acute or long-term disease-related changes or their alleviation by therapy with morphological data, in order to obtain a comprehensive understanding of the underlying processes and mechanisms.
- Open Access
- 4 April 2012
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 32 (14) , 4861-4866
BK Channels Mediate Pathway-Specific Modulation of Visual Signals in theIn VivoMouse Retina
The modulatory role of large-conductance Ca2+-activated K+(BK) channels in the nervous system has been extensively studied. In the retina, it has been shown that BK channels play a pivotal role in modulating feedback from A17 amacrine cells to rod bipolar cells (RBCs). Here, we used electroretinography to examine the functional role of BK channels for rod and cone vision in the retinain vivousing a genetically engineered mouse lacking functional BK channels (Bk−/−). Under dark-adapted and light-adapted conditions, the lack of BK channels had no effect on photoreceptor activity, suggesting that these ion channels do not modulate photoreceptor responses. At the bipolar cell level, the ERG signals attributed to RBCs inBk−/−mice were not different from those in wild-type mice at low scotopic stimulus intensities. However, at high scotopic and low mesopic stimulus intensities, close to RBC saturation, a significant reduction of ERG signals reflecting RBC activity was present in theBk−/−retina. At higher mesopic stimulus intensities activating both RBCs and cone bipolar cells (CBCs), no difference in ERG signals betweenBk−/−and wild-type mice was found. In photopic stimulus paradigms, activity of ON- and OFF-CBCs inBk−/−and wild-type retinae was indistinguishable. These findings demonstrate that BK channels modulate visual responsesin vivoat the bipolar cell level at intermediate stimulus conditions.
- 4 April 2012
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 32 (14) , 4861-4866
Open AccessBK Channels Mediate Pathway-Specific Modulation of Visual Signals in theIn VivoMouse Retina
The modulatory role of large-conductance Ca2+-activated K+(BK) channels in the nervous system has been extensively studied. In the retina, it has been shown that BK channels play a pivotal role in modulating feedback from A17 amacrine cells to rod bipolar cells (RBCs). Here, we used electroretinography to examine the functional role of BK channels for rod and cone vision in the retinain vivousing a genetically engineered mouse lacking functional BK channels (Bk−/−). Under dark-adapted and light-adapted conditions, the lack of BK channels had no effect on photoreceptor activity, suggesting that these ion channels do not modulate photoreceptor responses. At the bipolar cell level, the ERG signals attributed to RBCs inBk−/−mice were not different from those in wild-type mice at low scotopic stimulus intensities. However, at high scotopic and low mesopic stimulus intensities, close to RBC saturation, a significant reduction of ERG signals reflecting RBC activity was present in theBk−/−retina. At higher mesopic stimulus intensities activating both RBCs and cone bipolar cells (CBCs), no difference in ERG signals betweenBk−/−and wild-type mice was found. In photopic stimulus paradigms, activity of ON- and OFF-CBCs inBk−/−and wild-type retinae was indistinguishable. These findings demonstrate that BK channels modulate visual responsesin vivoat the bipolar cell level at intermediate stimulus conditions.
- 11 November 2011
- Published by Springer Nature
- p. E1
Erratum to: HCN1 Channels Significantly Shape Retinal Photoresponses
- 11 November 2011
- Published by Springer Nature
- p. E1
Erratum to: HCN1 Channels Significantly Shape Retinal Photoresponses
- 11 November 2011
- Published by Springer Nature
- Vol. 723, 807-812
HCN1 Channels Significantly Shape Retinal Photoresponses
Hyperpolarization-activated and cyclic nucleotide-gated (HCN) channels are encoded by four genes (HCN1-4) and are widely expressed in the central and peripheral nervous system and in cardiac tissues. All types of HCN channels are also expressed in the retina. Due to their rapid activation, HCN1 channels, which are expressed most abundantly in the inner segments of the photoreceptors, are particularly well suited to modulate retinal responses to flashed light or background light. In vivo functional analysis of HCN1 knockout mice using electroretinography has shown that HCN1 channels shorten retinal light responses under scotopic conditions and thus play an important role for the responsiveness to high-frequency repetitive stimuli. This chapter summarizes the functional phenotype of HCN1 knockout mice.
- 11 November 2011
- Published by Springer Nature
- Vol. 723, 807-812
HCN1 Channels Significantly Shape Retinal Photoresponses
Hyperpolarization-activated and cyclic nucleotide-gated (HCN) channels are encoded by four genes (HCN1-4) and are widely expressed in the central and peripheral nervous system and in cardiac tissues. All types of HCN channels are also expressed in the retina. Due to their rapid activation, HCN1 channels, which are expressed most abundantly in the inner segments of the photoreceptors, are particularly well suited to modulate retinal responses to flashed light or background light. In vivo functional analysis of HCN1 knockout mice using electroretinography has shown that HCN1 channels shorten retinal light responses under scotopic conditions and thus play an important role for the responsiveness to high-frequency repetitive stimuli. This chapter summarizes the functional phenotype of HCN1 knockout mice.
- 12 October 2006
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 113 (3) , 171-177
Negative scotopic ERG and photopic ERG ON response impairment in a patient with normal dark adaptation
- 12 October 2006
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 113 (3) , 171-177
Negative scotopic ERG and photopic ERG ON response impairment in a patient with normal dark adaptation