Gianfranco Ferrari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gianfranco Ferrari has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Arianna Di Molfetta
Department of Pediatric Cardiology and Cardio Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
5 shared publicationsKrzysztof Zieliński
Nałęcz Institute of Biocybernetics and Biomedical Engineering, PAS, Warsaw, Poland
4 shared publications- Libera Fresiello
Cardiovascular and Respiratory Physiology, TechMed Centre, University of Twente, Enschede, The Netherlands
4 shared publications Maciej Kozarski
Nałęcz Institute of Biocybernetics and Biomedical Engineering, PAS, Warsaw, Poland
4 shared publications- Claudio De Lazzari
Human Movement and Sport Sciences, University of Rome “Foro Italico”, 00135 Rome, Italy
3 shared publications Krystyna Górczyńska
Nałęcz Institute of Biocybernetics and Biomedical Engineering, PAS, Warsaw, Poland
3 shared publications
Latest Publications
- 16 June 2017
- Published by Wiley in Artificial Organs
- Vol. 41 (12) , 1099-1108
Control of a Pediatric Pulsatile Ventricular Assist Device: A Hybrid Cardiovascular Model Study
The aim of this work is to study pediatric pneumatic ventricle (PVAD) performance, versus VAD rate (VADR) and native heart rate (HR) ratio Rr (VADR/HR). The study uses a hybrid model of the cardiovascular system (HCS). HCS consists of a computational part (a lumped parameter model including left and right ventricles, systemic and pulmonary arterial and venous circulation) interfaced to a physical part. This permits the connection of a VAD (15 mL PVAD). Echocardiographic and hemodynamic data of a pediatric patient (average weight 14.3 kg, HR 100 bpm, systemic pressure 75/44 mm Hg, CO 1.5 L/min) assisted apically with asynchronous PVAD were used to set up a basal condition in the model. After model tuning, the assistance was started, setting VAD parameters (ejection and filling pressures, systole duration) to completely fill and empty the PVAD. The study was conducted with constant HR and variable VADR (50‐120, step 10, bpm). Experiments were repeated for two additional patients' HRs, 90 and 110 bpm and for two values of systemic arterial resistance (Ras) and Emax. Experimental data were collected and stored on disk. Analyzed data include average left and right ventricular volumes (LVV, RVV), left ventricular flow (LVF), VAD flow (VADF), and total cardiac output (COt). Data were analyzed versus Rr. LVV and RVV are sensitive to Rr and a left ventricular unloading corresponds in general to a right ventricular loading. In the case of asynchronous assistance, frequency beats are always present and the beat rate is equal to the difference between HR and VADR. In the case of pulsatile asynchronous LVAD assistance, VADR should be chosen to minimize frequency beat effects and right ventricular loading and to maximize left ventricular unloading.
- 16 June 2017
- Published by Wiley in Artificial Organs
- Vol. 41 (12) , 1099-1108
Control of a Pediatric Pulsatile Ventricular Assist Device: A Hybrid Cardiovascular Model Study
The aim of this work is to study pediatric pneumatic ventricle (PVAD) performance, versus VAD rate (VADR) and native heart rate (HR) ratio Rr (VADR/HR). The study uses a hybrid model of the cardiovascular system (HCS). HCS consists of a computational part (a lumped parameter model including left and right ventricles, systemic and pulmonary arterial and venous circulation) interfaced to a physical part. This permits the connection of a VAD (15 mL PVAD). Echocardiographic and hemodynamic data of a pediatric patient (average weight 14.3 kg, HR 100 bpm, systemic pressure 75/44 mm Hg, CO 1.5 L/min) assisted apically with asynchronous PVAD were used to set up a basal condition in the model. After model tuning, the assistance was started, setting VAD parameters (ejection and filling pressures, systole duration) to completely fill and empty the PVAD. The study was conducted with constant HR and variable VADR (50‐120, step 10, bpm). Experiments were repeated for two additional patients' HRs, 90 and 110 bpm and for two values of systemic arterial resistance (Ras) and Emax. Experimental data were collected and stored on disk. Analyzed data include average left and right ventricular volumes (LVV, RVV), left ventricular flow (LVF), VAD flow (VADF), and total cardiac output (COt). Data were analyzed versus Rr. LVV and RVV are sensitive to Rr and a left ventricular unloading corresponds in general to a right ventricular loading. In the case of asynchronous assistance, frequency beats are always present and the beat rate is equal to the difference between HR and VADR. In the case of pulsatile asynchronous LVAD assistance, VADR should be chosen to minimize frequency beat effects and right ventricular loading and to maximize left ventricular unloading.
- Open Access
- 1 January 2015
- Published by Procon, Ltd. in Biomed Data Journal
- Vol. 1 (3) , 45-50
Circulatory Modelling as a Clinical Decision Support and an Educational Tool
Circulatory Modelling as a Clinical Decision Support and an Educational Tool
- 1 January 2015
- Published by Procon, Ltd. in Biomed Data Journal
- Vol. 1 (3) , 45-50
Open AccessCirculatory Modelling as a Clinical Decision Support and an Educational Tool
Circulatory Modelling as a Clinical Decision Support and an Educational Tool
- 5 March 2013
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 16 (2) , 149-156
Continuous-flow pump model study: the effect on pump performance of pump characteristics and cardiovascular conditions
This model study evaluates the effect of pump characteristics and cardiovascular data on hemodynamics in atrio–aortic VAD assistance. The model includes a computational circulatory sub-model and an electrical sub-model representing two rotary blood pumps through their pressure–flow characteristics. The first is close to a pressure generator—PG (average flow sensitivity to pressure variations, −0.047 l mmHg−1); the second is closer to a flow generator—FG (average flow sensitivity to pressure variations, −0.0097 l mmHg−1). Interaction with VAD was achieved by means of two interfaces, behaving as impedance transformers. The model was verified by use of literature data and VAD onset conditions were used as a control for the experiments. Tests compared the two pumps, at constant pump speed, in different ventricular and circulatory conditions: maximum ventricular elastance (0.44–0.9 mmHg cm−3), systemic peripheral resistance (781–1200 g cm−4 s−1), ventricular diastolic compliance C p (5–10–50 cm3 mmHg−1), systemic arterial compliance (0.9–1.8 cm3 mmHg−1). Analyzed variables were: arterial and venous pressures, flows, ventricular volume, external work, and surplus hemodynamic energy (SHE). The PG pump generated the highest SHE under almost all conditions, in particular for higher C p (+50 %). PG pump flow is also the most sensitive to E max and C p changes (−26 and −33 %, respectively). The FG pump generally guarantees higher external work reduction (54 %) and flow less dependent on circulatory and ventricular conditions. The results are evidence of the importance of pump speed regulation with changing ventricular conditions. The computational sub-model will be part of a hydro-numerical model, including autonomic controls, designed to test different VADs.
- 5 March 2013
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 16 (2) , 149-156
Continuous-flow pump model study: the effect on pump performance of pump characteristics and cardiovascular conditions
This model study evaluates the effect of pump characteristics and cardiovascular data on hemodynamics in atrio–aortic VAD assistance. The model includes a computational circulatory sub-model and an electrical sub-model representing two rotary blood pumps through their pressure–flow characteristics. The first is close to a pressure generator—PG (average flow sensitivity to pressure variations, −0.047 l mmHg−1); the second is closer to a flow generator—FG (average flow sensitivity to pressure variations, −0.0097 l mmHg−1). Interaction with VAD was achieved by means of two interfaces, behaving as impedance transformers. The model was verified by use of literature data and VAD onset conditions were used as a control for the experiments. Tests compared the two pumps, at constant pump speed, in different ventricular and circulatory conditions: maximum ventricular elastance (0.44–0.9 mmHg cm−3), systemic peripheral resistance (781–1200 g cm−4 s−1), ventricular diastolic compliance C p (5–10–50 cm3 mmHg−1), systemic arterial compliance (0.9–1.8 cm3 mmHg−1). Analyzed variables were: arterial and venous pressures, flows, ventricular volume, external work, and surplus hemodynamic energy (SHE). The PG pump generated the highest SHE under almost all conditions, in particular for higher C p (+50 %). PG pump flow is also the most sensitive to E max and C p changes (−26 and −33 %, respectively). The FG pump generally guarantees higher external work reduction (54 %) and flow less dependent on circulatory and ventricular conditions. The results are evidence of the importance of pump speed regulation with changing ventricular conditions. The computational sub-model will be part of a hydro-numerical model, including autonomic controls, designed to test different VADs.
- 20 September 2011
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 15 (1) , 32-43
A modular computational circulatory model applicable to VAD testing and training
Aim of this work was to develop a modular computational model able to interact with ventricular assist devices (VAD) for research and educational applications. The lumped parameter model consists of five functional modules (left and right ventricles, systemic, pulmonary, and coronary circulation) that are easily replaceable if necessary. The possibility of interacting with VADs is achieved via interfaces acting as impedance transformers. This last feature was tested using an electrical VAD model. Tests were aimed at demonstrating the possibilities and verifying the behavior of interfaces when testing VADs connected in different ways to the circulatory system. For these reasons, experiments were performed in a purely numerical mode, simulating a caval occlusion, and with the model interfaced to an external left-VAD (LVAD) in two different ways: with atrioaortic and ventriculoaortic connection. The caval occlusion caused the leftward shift of the LV p–v loop, along with the drop in arterial and ventricular pressures. A narrower LV p–v loop and cardiac output and aortic pressure rise were the main effects of atrioaortic assistance. A wider LV p–v loop and a ventricular average volume drop were the main effects of ventricular-aortic assistance. Results coincided with clinical and experimental data attainable in the literature. The model will be a component of a hydronumerical model designed to be connected to different types of VADs. It will be completed with autonomic features, including the baroreflex and a more detailed coronary circulation model.
- 20 September 2011
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 15 (1) , 32-43
A modular computational circulatory model applicable to VAD testing and training
Aim of this work was to develop a modular computational model able to interact with ventricular assist devices (VAD) for research and educational applications. The lumped parameter model consists of five functional modules (left and right ventricles, systemic, pulmonary, and coronary circulation) that are easily replaceable if necessary. The possibility of interacting with VADs is achieved via interfaces acting as impedance transformers. This last feature was tested using an electrical VAD model. Tests were aimed at demonstrating the possibilities and verifying the behavior of interfaces when testing VADs connected in different ways to the circulatory system. For these reasons, experiments were performed in a purely numerical mode, simulating a caval occlusion, and with the model interfaced to an external left-VAD (LVAD) in two different ways: with atrioaortic and ventriculoaortic connection. The caval occlusion caused the leftward shift of the LV p–v loop, along with the drop in arterial and ventricular pressures. A narrower LV p–v loop and cardiac output and aortic pressure rise were the main effects of atrioaortic assistance. A wider LV p–v loop and a ventricular average volume drop were the main effects of ventricular-aortic assistance. Results coincided with clinical and experimental data attainable in the literature. The model will be a component of a hydronumerical model designed to be connected to different types of VADs. It will be completed with autonomic features, including the baroreflex and a more detailed coronary circulation model.
- 5 July 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (9) , 902-911
Hybrid Model Analysis of Intra‐Aortic Balloon Pump Performance as a Function of Ventricular and Circulatory Parameters
We investigated the effects of the intra‐aortic balloon pump (IABP) on endocardial viability ratio (EVR), cardiac output (CO), end‐systolic (Ves) and end‐diastolic (Ved) ventricular volumes, total coronary blood flow (TCBF), and ventricular energetics (external work [EW], pressure–volume area [PVA]) under different ventricular (Emax and diastolic stiffness) and circulatory (arterial compliance) parameters. We derived a hybrid model from a computational model, which is based on merging computational and hydraulic submodels. The lumped parameter computational submodel consists of left and right hearts and systemic, pulmonary, and coronary circulations. The hydraulic submodel includes part of the systemic arterial circulation, essentially a silicone rubber tube representing the aorta, which contains a 40‐mL IAB. EVR, CO, Ves, and Ved, TCBF and ventricular energetics (EW, PVA) were analyzed against the ranges of left ventricular Emax (0.3–0.5–1 mm Hg/cm3) and diastolic stiffness Vstiffness (≈0.08 and ≈0.3 mm Hg/cm3, obtained by changing diastolic stiffness constant) and systemic arterial compliance (1.8–2.5 cm3/mm Hg). All experiments were performed comparing the selected variables before and during IABP assistance. Increasing Emaxl from 0.5 to 2 mm Hg/cm3 resulted in IABP assistance producing lower percentage changes in the selected variables. The changes in ventricular diastolic stiffness strongly influence both absolute value of EVR and its variations during IABP (71 and 65% for lower and higher arterial compliance, respectively). Ved and Ves changes are rather small but higher for lower Emax and higher Vstiffness. Lower Emax and higher Vstiffness resulted in higher TCBF and CO during IABP assistance (∼35 and 10%, respectively). The use of this hybrid model allows for testing real devices in realistic, stable, and repeatable circulatory conditions. Specifically, the presented results show that IABP performance is dependent, at least in part, on left ventricular filling, ejection characteristics, and arterial compliance. It is possible in this way to simulate patient‐specific conditions and predict the IABP performance at different values of the circulatory or ventricular parameters. Further work is required to study the conditions for heart recovery modeling, baroreceptor controls, and physiological feedbacks.
- 5 July 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (9) , 902-911
Hybrid Model Analysis of Intra‐Aortic Balloon Pump Performance as a Function of Ventricular and Circulatory Parameters
We investigated the effects of the intra‐aortic balloon pump (IABP) on endocardial viability ratio (EVR), cardiac output (CO), end‐systolic (Ves) and end‐diastolic (Ved) ventricular volumes, total coronary blood flow (TCBF), and ventricular energetics (external work [EW], pressure–volume area [PVA]) under different ventricular (Emax and diastolic stiffness) and circulatory (arterial compliance) parameters. We derived a hybrid model from a computational model, which is based on merging computational and hydraulic submodels. The lumped parameter computational submodel consists of left and right hearts and systemic, pulmonary, and coronary circulations. The hydraulic submodel includes part of the systemic arterial circulation, essentially a silicone rubber tube representing the aorta, which contains a 40‐mL IAB. EVR, CO, Ves, and Ved, TCBF and ventricular energetics (EW, PVA) were analyzed against the ranges of left ventricular Emax (0.3–0.5–1 mm Hg/cm3) and diastolic stiffness Vstiffness (≈0.08 and ≈0.3 mm Hg/cm3, obtained by changing diastolic stiffness constant) and systemic arterial compliance (1.8–2.5 cm3/mm Hg). All experiments were performed comparing the selected variables before and during IABP assistance. Increasing Emaxl from 0.5 to 2 mm Hg/cm3 resulted in IABP assistance producing lower percentage changes in the selected variables. The changes in ventricular diastolic stiffness strongly influence both absolute value of EVR and its variations during IABP (71 and 65% for lower and higher arterial compliance, respectively). Ved and Ves changes are rather small but higher for lower Emax and higher Vstiffness. Lower Emax and higher Vstiffness resulted in higher TCBF and CO during IABP assistance (∼35 and 10%, respectively). The use of this hybrid model allows for testing real devices in realistic, stable, and repeatable circulatory conditions. Specifically, the presented results show that IABP performance is dependent, at least in part, on left ventricular filling, ejection characteristics, and arterial compliance. It is possible in this way to simulate patient‐specific conditions and predict the IABP performance at different values of the circulatory or ventricular parameters. Further work is required to study the conditions for heart recovery modeling, baroreceptor controls, and physiological feedbacks.
- 1 December 2008
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 31 (12) , 1043-1054
Application of a user-friendly comprehensive circulatory model for estimation of hemodynamic and ventricular variables
Purpose: Application of a comprehensive, user-friendly, digital computer circulatory model to estimate hemodynamic and ventricular variables. Methods: The closed-loop lumped parameter circulatory model represents the circulation at the level of large vessels. A variable elastance model reproduces ventricular ejection. The circulatory model has been modified embedding an algorithm able to adjust the model parameters reproducing specific circulatory conditions. The algorithm reads input variables: heart rate, aortic pressure, cardiac output, and left atrial pressure. After a preliminary estimate of circulatory parameters and ventricular elastance, it adjusts the amount of circulating blood, the value of the systemic peripheral resistance, left ventricular elastance, and ventricular rest volume. Input variables and the corresponding calculated variables are recursively compared: the procedure is stopped if the difference between input and calculated variables is within the set tolerance. At the procedure end, the model produces an estimate of ventricular volumes and Emaxl along with systemic and pulmonary pressures (output variables). The procedure has been tested using 4 sets of experimental data including left ventricular assist device assistance. Results: The algorithm allows the reproduction of the circulatory conditions defined by all input variable sets, giving as well an estimate of output variables. Conclusions: The algorithm permits application of the model in environments where the simplicity of use and velocity of execution are of primary importance. Due to its modular structure, the model can be modified adding new circulatory districts or changing the existing ones. The model could also be applied in educational applications.
- 1 December 2008
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 31 (12) , 1043-1054
Application of a user-friendly comprehensive circulatory model for estimation of hemodynamic and ventricular variables
Purpose: Application of a comprehensive, user-friendly, digital computer circulatory model to estimate hemodynamic and ventricular variables. Methods: The closed-loop lumped parameter circulatory model represents the circulation at the level of large vessels. A variable elastance model reproduces ventricular ejection. The circulatory model has been modified embedding an algorithm able to adjust the model parameters reproducing specific circulatory conditions. The algorithm reads input variables: heart rate, aortic pressure, cardiac output, and left atrial pressure. After a preliminary estimate of circulatory parameters and ventricular elastance, it adjusts the amount of circulating blood, the value of the systemic peripheral resistance, left ventricular elastance, and ventricular rest volume. Input variables and the corresponding calculated variables are recursively compared: the procedure is stopped if the difference between input and calculated variables is within the set tolerance. At the procedure end, the model produces an estimate of ventricular volumes and Emaxl along with systemic and pulmonary pressures (output variables). The procedure has been tested using 4 sets of experimental data including left ventricular assist device assistance. Results: The algorithm allows the reproduction of the circulatory conditions defined by all input variable sets, giving as well an estimate of output variables. Conclusions: The algorithm permits application of the model in environments where the simplicity of use and velocity of execution are of primary importance. Due to its modular structure, the model can be modified adding new circulatory districts or changing the existing ones. The model could also be applied in educational applications.
- 21 December 2006
- Published by Wiley in Artificial Organs
- Vol. 31 (1) , 73-79
Numerical Simulation of Hemodynamic Changes During Beating‐heart Surgery: Analysis of the Effects of Cardiac Position Alteration in an Animal Model
Abstract: Hemodynamic instability, mostly due to vertical lifting of the heart, is usually observed during beating‐heart surgical procedures. However, some hemodynamic parameters, such as coronary blood flow, are not routinely measured. A digital computer model of the circulation able to simulate and analyze the effects of heart lifting and the Trendelenburg maneuver, and thus supply detailed hemodynamic information to the clinicians would provide a useful analytical tool. A lumped parameters model of the circulation was applied to both β‐blocked and not β‐blocked pigs. The results confirmed a drop of cardiac output and coronary flow during heart lifting and a rise of both variables after the Trendelenburg maneuver for β‐blocked animals. In not β‐blocked pigs, the analysis was more complex but the model reproduced experimental data and permitted coronary flow to be estimated. These results showed the feasibility of numerical simulation for specific circulatory conditions encountered during beating‐heart surgery.
- 21 December 2006
- Published by Wiley in Artificial Organs
- Vol. 31 (1) , 73-79
Numerical Simulation of Hemodynamic Changes During Beating‐heart Surgery: Analysis of the Effects of Cardiac Position Alteration in an Animal Model
Abstract: Hemodynamic instability, mostly due to vertical lifting of the heart, is usually observed during beating‐heart surgical procedures. However, some hemodynamic parameters, such as coronary blood flow, are not routinely measured. A digital computer model of the circulation able to simulate and analyze the effects of heart lifting and the Trendelenburg maneuver, and thus supply detailed hemodynamic information to the clinicians would provide a useful analytical tool. A lumped parameters model of the circulation was applied to both β‐blocked and not β‐blocked pigs. The results confirmed a drop of cardiac output and coronary flow during heart lifting and a rise of both variables after the Trendelenburg maneuver for β‐blocked animals. In not β‐blocked pigs, the analysis was more complex but the model reproduced experimental data and permitted coronary flow to be estimated. These results showed the feasibility of numerical simulation for specific circulatory conditions encountered during beating‐heart surgery.
- Open Access
- 1 October 2005
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 28 (10) , 1054
Comments on Paper: “Hybrid Test Bench for Evaluation of Any Device Related to Mechanical Cardiac Assistance”
- 1 October 2005
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 28 (10) , 1054
Open AccessComments on Paper: “Hybrid Test Bench for Evaluation of Any Device Related to Mechanical Cardiac Assistance”
- 1 July 2005
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 28 (7) , 750-759
Development of a Hybrid (numerical-hydraulic) Circulatory Model: Prototype Testing and Its Response to IABP Assistance
Merging numerical and physical models of the circulation makes it possible to develop a new class of circulatory models defined as hybrid. This solution reduces the costs, enhances the flexibility and opens the way to many applications ranging from research to education and heart assist devices testing. In the prototype described in this paper, a hydraulic model of systemic arterial tree is connected to a lumped parameters numerical model including pulmonary circulation and the remaining parts of systemic circulation. The hydraulic model consists of a characteristic resistance, of a silicon rubber tube to allow the insertion of an Intra-Aortic Balloon Pump (IABP) and of a lumped parameters compliance. Two electro-hydraulic interfaces, realized by means of gear pumps driven by DC motors, connect the numerical section with both terminals of the hydraulic section. The lumped parameters numerical model and the control system (including analog to digital and digital to analog converters) are developed in LabVIEW ™ environment. The behavior of the model is analyzed by means of the ventricular pressure-volume loops and the time courses of arterial and ventricular pressures and flows in different circulatory conditions. A simulated pathological condition was set to test the IABP and verify the response of the system to this type of mechanical circulatory assistance. The results show that the model can represent hemodynamic relationships in different ventricular and circulatory conditions and is able to react to the IABP assistance.
- 1 July 2005
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 28 (7) , 750-759
Development of a Hybrid (numerical-hydraulic) Circulatory Model: Prototype Testing and Its Response to IABP Assistance
Merging numerical and physical models of the circulation makes it possible to develop a new class of circulatory models defined as hybrid. This solution reduces the costs, enhances the flexibility and opens the way to many applications ranging from research to education and heart assist devices testing. In the prototype described in this paper, a hydraulic model of systemic arterial tree is connected to a lumped parameters numerical model including pulmonary circulation and the remaining parts of systemic circulation. The hydraulic model consists of a characteristic resistance, of a silicon rubber tube to allow the insertion of an Intra-Aortic Balloon Pump (IABP) and of a lumped parameters compliance. Two electro-hydraulic interfaces, realized by means of gear pumps driven by DC motors, connect the numerical section with both terminals of the hydraulic section. The lumped parameters numerical model and the control system (including analog to digital and digital to analog converters) are developed in LabVIEW ™ environment. The behavior of the model is analyzed by means of the ventricular pressure-volume loops and the time courses of arterial and ventricular pressures and flows in different circulatory conditions. A simulated pathological condition was set to test the IABP and verify the response of the system to this type of mechanical circulatory assistance. The results show that the model can represent hemodynamic relationships in different ventricular and circulatory conditions and is able to react to the IABP assistance.