  • Evaluation of coagulation stages of hemorrhaged swine: comparison of thromboelastography and rotational elastometry

    by Toshiki Tomori, Daniel Hupalo, Kohsuke Teranishi, Sarah Michaud, Mike Hammett, Daniel Freilich, Richard McCarron, Françoise Arnaud

    Thromboelastography (TEG) or rotational thromboelastometry (ROTEM) assesses blood viscoelastic properties and clotting kinetics that can be measured by Haemoscope TEG and Pentapharm ROTEM devices using slightly different methodologies. These devices were compared by measuring blood samples associated with various degrees of coagulopathy. Blood samples, collected from swine undergoing three types of severe injury and resuscitation protocol resulting in normal, hypercoagulopathy, and hypocoagulopathy, were assessed with TEG or ROTEM before the surgical procedures, and after injury, fluid resuscitation, and simulated hospital phase. Standard clotting parameters were compared by Student's t-test at a significance of a P value less than 0.05. Regression analysis indicated a positive correlation between TEG and ROTEM for reaction time (R), clotting rate (K), and maximum amplitude (Ma) parameters. With samples of normal coagulation, R (440 +/- 136 vs. 391 +/- 73 s), K (99 +/- 39 vs. 81 +/- 20 s), and Ma (74 +/- 4 vs. 69 +/- 5 mm) were higher, whereas (alpha) (68 +/- 8 vs. 75 +/- 3 mm) was lower with TEG than ROTEM, respectively; a P value is less than 0.05. The magnitude of changes from baseline in hypercoagulable or hypocoagulable samples due to level of injury was equivalent with TEG and ROTEM indicating comparable use of the instruments. However, when samples were extremely hypocoagulopathic due to resuscitation fluid, the TEG values could not be readily determined. Overall, TEG readings were higher than ROTEM readings; this disparity between the two instruments was attenuated with hypercoaguable samples. Both devices yielded similar information regarding the status of coagulation related to trauma. Because of operating characteristics, the same instrument should be used for monitoring the same patient or study.


  • Exothermic Reaction in Zeolite Hemostatic Dressings: QuikClot ACS and ACS+®

    by Françoise Arnaud, Toshiki Tomori, Walter Carr, Anne McKeague, Kohsuke Teranishi, Keith Prusaczyk, Richard McCarron

    Background Zeolites have hemostatic properties used to stop bleeding in severe hemorrhage. Manufactured QuikClot® is an approved zeolite-based hemostatic agent for battlefield use. The exothermic reaction associated with QuikClot as loose granules or as granules packaged in a mesh bag has potential burn effects; this led to the development of a formulation of “cooler” non-exothermic QuikClot. The goal of this study was to compare the elevation of temperature of these formulations upon contact with blood. Methods Following full transection of the femoral vasculature, anesthetized Yorkshire pigs (n = 15) (28.8 ± 1.5 kg) were hemorrhaged for 2 min and treated with 100 g of bagged QuikClot (Advanced Clotting Sponge (ACS) (n = 4)) or a modified non-exothermic formulation (ACS+ (n = 11)). Vital signs and temperature at the dressing/tissue interface were continuously recorded for 3 h. Additional procedures were used to examine effects of different ratios of blood to zeolite on temperature elevation. Results Total post-treatment blood loss was comparable for ACS+_E and ACS_E groups (overall average: 18.6 ± 10.5% EBV). Temperature recorded at the dressing/tissue interface was significantly lower with ACS+ vs. ACS (40.3 ± 1.8 vs. 61.4 ± 10.7 °C, respectively, p < 0.01) and was 3.2 ± 2.6 °C higher than rectal temperature (38.0 ± 0.7 °C, p < 0.01). Survival at endpoint (7/11 vs. 4/4) and average survival time (134 ± 64 vs. 180 min) were greater for both ACS+ and ACS in comparison to Standard Dressing. The wound temperature with ACS was reduced with greater blood to product ratios and this pattern was paralleled with in vitro measurements. Conclusions The lower heat release with ACS+ compared to ACS was confirmed in an animal model and ACS+ had similar efficacy in arresting bleeding when compared to Standard Dressing.