JDJenny Dankelman

Jenny Dankelman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jenny Dankelman has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Systems approach to reduce errors in surgery

    by J. Dankelman, C. A. Grimbergen

    Reducing the number of medical errors significantly is the challenge for the coming decade. In medicine and in surgery, in particular, errors are traditionally treated as being committed by individuals. To reduce human errors, two approaches can be used: the person approach and the systems approach. In the systems approach, the operator is not blamed, but the system is analyzed in order to find the causes of errors. Furthermore, defenses are built into the system so that errors will not result in an adverse outcome anymore. This article aims to provide insight into the systems approach.


  • Fundamental aspects of learning minimally invasive surgical skills

    by J. Dankelman, M. K. Chmarra, E. G. G. Verdaasdonk, L. P. S. Stassen, C. A. Grimbergen

    With the introduction of minimally invasive surgery (MIS) the necessity to develop training methods to learn skills outside the operating room (OR) became clear. Several training simulators have become commercially available. However, fundamental research into the requirements for effective and efficient training in MIS is still lacking. Yet in the literature several learning models have been described that may be used when designing the structure of a training program. While learning skills, three stages can be observed: cognitive, associative and autonomous. The learning cycle also includes different learning styles and, moreover, every trainee has his/her preferred learning style. Furthermore, training should be adapted to the level of behaviour: skill‐based, rule‐based or knowledge‐based. Training of complex skills should include multiple performance objectives, such as just‐in‐time supportive information and part‐task practice. Finally, motivation for training can be created by assessment. In conclusion, several theories on learning can be found in the literature. These theories may help in the development of effective training programs for training MIS skills outside the OR.


  • The optimal mechanical efficiency of laparoscopic forceps

    by E. A. M. Heijnsdijk, A. Pasdeloup, J. Dankelman, D. J. Gouma

    Laparoscopic forceps have a large amount of friction in the mechanism, leading to a limited mechanical efficiency, which impairs the pinch force feedback. The advantage of a small amount of friction is that it is easier to maintain a constant pinch force on the tissue. Therefore, to obtain the optimal mechanical efficiency of the forceps, the influence of mechanical efficiency on the performance of several static and dynamic operative tasks, such as grasping tissue and estimating pressure, is quantified. A grasper with adjustable mechanical efficiency and a load cell to measure the pinch force on the tissue was developed. Using this grasper, subjects performed several tasks on pig bowel tissue and simulation tissue: grasping tissue, reproducing a requested constant or variable pinch forces, and estimating the pressure in a tube. With increasing mechanical efficiency, a variable pinch force could be reproduced more accurately (deviation from the requested pinch force decreased from 34.4 to 24.9%, p = 0.016). The performance on the grasping tissue, reproducing a constant pinch force, and estimating pressure tasks did not improve with increased mechanical efficiency. The optimal mechanical efficiency of laparoscopic forceps is dependent on the task that is performed. For tasks requiring little movement of the forceps, such as grasping and holding tissue, a low mechanical efficiency is sufficient, whereas for tasks requiring repeated movement of the forceps to feel tissue, a high mechanical efficiency is required.


  • Problems with Laparoscopic Instruments: Opinions of Experts

    by K.T. Den Boer, T. de Jong, J. Dankelman, D.J. Gouma

    Introduction: Laparoscopic surgery is particularly known for its complex technique, which calls for operative analysis of laparoscopic instruments. This study investigates the opinion of experts about clinical problems with instruments occurring during laparoscopic surgery. Methods: A questionnaire was used to obtain the opinions of expert laparoscopic surgeons about difficulties experienced operatively using laparoscopic instruments. Results: The laparoscopic surgeons indicated that coagulators were especially prone to cause complications of the gastro-intestinal tract, vascular injuries, and bile duct injuries. Dissectors were considered to play a role in the occurrence of solid organ and bile duct injuries, and retractors to cause solid organ injuries. Insufficient functionality of the instruments and insufficient quality of the image were indicated to contribute to the instrument's risks. Conclusion: The questionnaire identified technological deficiencies prone to cause operative complications. The results provide a basis for the interaction between surgeons and engineers, and serve as pilot information on which to base an in-depth object evaluation of instrument problems.


  • Interaction between Gregg's phenomenon and coronary flow control: a model study

    by J. Dankelman, H. G. Stassen, J. A. E. Spaan

    Coronary perfusion pressure, Pp, affects coronary arterial resistance, Ra, (autoregulation) as well as myocardial oxygen consumption, MVo2 (Gregg's phenomenon). The interaction between the effects of Pp and MVo2 on coronary flow control was investigated using a coronary flow control model. Model analysis predicts that response of the pressure-flow ratio, p/q(t), following a change in Pp depends on the sensitivity of Ra to a change in tissue oxygen concentration (tone sensitivity) and on the sensitivity of MVo2 to a change in capillary pressure (Gregg's sensitivity). At high tone sensitivity Gregg's effect is small, whereas at high Gregg's sensitivity autoregulation is attenuated. In experiments glibenclamide decelerated the p/q(t) in response to a pressure step by a factor of four. However, the proposed model demonstrates that this is compatible with a reduction in rate of change of Ra by a factor of ten. This is due to the interaction of negative and positive feedback gains in the model. Model analysis demonstrates that autoregulation and Gregg's phenomenon compete with each other in controlling coronary flow.


  • Transients in myocardial O2 consumption after abrupt changes in perfusion pressure in goats

    by J. Dankelman, C. P. Van der Ploeg, J. A. Spaan

    The dynamic oxygen content differences were analyzed in the present study. The left main coronary artery of the anesthetized, open-chest goat was perfused at constant pressure (Pp). Pp(t), arterial flow [Qa(t)], and the arteriovenous oxygen content difference [a-vO2(t)] were averaged per beat. The a-vO2 signal was corrected for mixing processes in the capillaries and transport time from capillaries to the venous measuring site [a-vO2(t)]. A change in Pp of 20 mmHg induced a temporary change in MVO2, referred to as the dynamic Gregg effect. With an increase in Pp, the maximal change of myocardial oxygen consumption [MVO2(t) = Qa(t).a-vO2(t)] was 15.0 +/- 3.6% (means +/- SE) during control and 31.3 +/- 2.3% with glibenclamide. With a decrease in Pp these changes were 16.3 +/- 2.9 and 21.0 +/- 1.1%. During control, the half-time for the rate of return of the MVO2 response was 4.2 +/- 0.8 s for an increase and 4.0 +/- 1.0 s for a decrease in Pp. With glibenclamide these values were 16.9 +/- 2.2 and 22.6 +/- 2.0 s. This study confirms that during steady state the Pp-induced MVO2 (steady-state Gregg effect) is diminished by autoregulation. However, it is concluded that during transients following abrupt changes in Pp, large changes in MVO2 occur depending on the rate of regulation (dynamic Gregg effect).


  • Comparison of different oxygen exchange models

    by C. P. B. Van der Ploeg, J. Dankelman, H. G. Stassen, J. A. E. Spaan

    A functional distribution of coronary volume can be estimated from the response of arterio-venous O2 content difference (AVO2) to a flow step. However, the results depend on the assumed O2 exchange model. The previously used model consisted of a single mixed compartment with O2 exchange in series with an unmixed compartment without O2 exchange (reference model). The purpose of this study is to provide an estimate of the errors made in the volume estimations by not taking into account factors as flow heterogeneity, different mixing sites or Krogh-like O2 exchange. The approach is indirect: the response of the AVO2 to a flow step has been calculated with alternative O2 exchange models in which the factors mentioned are incorporated. These transients are fitted with the reference model. The resulting estimated volumes are different from the volumes assumed in the alternative models. Large differences are obtained with some of the alternative models, e.g. the model with Krogh characteristics. However, these models seem unrealistic because capillary pO2 is higher than venous pO2. Only small differences in volume are obtained with the more realistic models. Therefore, these results indicate that the coronary volumes are approximated well by the estimations obtained with the reference model. These volume estimations were 9.9 and 3.8 ml 100 g−1 for the O2 exchange vessels and the distal venous volume, respectively.


  • Theoretical Analysis of Coronary Blood Flow and Tissue Oxygen Pressure-Control

    by Jos A. E. Spaan, Jenny Dankelman

    Coronary blood flow is tightly coupled to the myocardial oxygen consumption. We have presented a control model based on the assumption that the tissue oxygen pressure is the controlled variable. The coronary blood flow in itself is not a controlled variable but merely the result of a different control system: the tissue oxygen pressure. From our control equation there is no relation between the slope of the autoregulation curve and the gain of the tissue P02 control system. The slope is independent of the level of oxygen consumption. Keywords Coronary Blood Flow Myocardial Oxygen Consumption Open Loop Gain Tissue Oxygen Pressure Autoregulation Curve These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.