Kimiya Shimizu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kimiya Shimizu has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Kazutaka Kamiya
School of Rehabilitation Sciences, Showa Medical University, Yokohama 2268555, Japan
6 shared publications Akihito Igarashi
5 shared publicationsKazutaka Kamiya
4 shared publications- Misae Ito
Department of Rehabilitation, Orthoptics and Visual Science Course, School of Allied Health Science, Kitasato University, Kanagawa, Japan
3 shared publications - Nobuyuki Shoji
Sagamihara, Japan
3 shared publications Hidenaga Kobashi
2 shared publications
Latest Publications
- 1 April 2016
- Vol. 120 (4) , 296-302
[Epidemiological Study of Poor Visual Acuity among Schoolchildren in Bonin Islands].
To investigate the change in uncorrected visual acuity (UCVA) among schoolchildren in Bonin Islands. UCVA of schoolchildren aged 6 to 14 years, was collected from reports of School Health Examination Surveys conducted from 1981 to 2012. The proportion of schoolchildren with poor UCVA in the Bonin Islands was compared with those in metropolitan Tokyo. The results in Bonin Islands were also divided into two groups, before- and after-1996 when terrestrial television broadcasting service has been started, and the data of those two groups were compared. The proportion of schoolchildren with poor UCVA in Bonin Islands was lower than that in Tokyo. Among the residents of Bonin Islands, the proportion of schoolchildren with UCVA of < 1.0 was higher in the after-1996 group than in the before- 1996 group, with a clear increase in schoolchildren with poor UCVA after 1996 (p < 0.01, Fisher's exact test), examined among the 4th grade of elementary school or above. After 1996, 26.6% of first graders at a public junior high school had poor UCVA of < 0.7, whereas before 1996 no such case could be detected. The present study revealed that the proportions of schoolchildren with poor UCVA in Bonin Islands was lower than that in Tokyo; but in the residents of Bonin Islands after 1996, the proportion of the schoolchildren with poor UCVA increased.
- 1 April 2016
- Vol. 120 (4) , 296-302
[Epidemiological Study of Poor Visual Acuity among Schoolchildren in Bonin Islands].
To investigate the change in uncorrected visual acuity (UCVA) among schoolchildren in Bonin Islands. UCVA of schoolchildren aged 6 to 14 years, was collected from reports of School Health Examination Surveys conducted from 1981 to 2012. The proportion of schoolchildren with poor UCVA in the Bonin Islands was compared with those in metropolitan Tokyo. The results in Bonin Islands were also divided into two groups, before- and after-1996 when terrestrial television broadcasting service has been started, and the data of those two groups were compared. The proportion of schoolchildren with poor UCVA in Bonin Islands was lower than that in Tokyo. Among the residents of Bonin Islands, the proportion of schoolchildren with UCVA of < 1.0 was higher in the after-1996 group than in the before- 1996 group, with a clear increase in schoolchildren with poor UCVA after 1996 (p < 0.01, Fisher's exact test), examined among the 4th grade of elementary school or above. After 1996, 26.6% of first graders at a public junior high school had poor UCVA of < 0.7, whereas before 1996 no such case could be detected. The present study revealed that the proportions of schoolchildren with poor UCVA in Bonin Islands was lower than that in Tokyo; but in the residents of Bonin Islands after 1996, the proportion of the schoolchildren with poor UCVA increased.
- Open Access
- 1 April 2016
- Published by Wolters Kluwer Health in Medicine
- Vol. 95 (14) , e3270
Long-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic Astigmatism
The study shows a promising next-generation surgical option for the correction of moderate to high ametropia. Hole implantable collamer lens (ICL), STAAR Surgical, is a posterior chamber phakic intraocular lens with a central artificial hole. As yet, however, no long-term comparison of the clinical results of the implantation of ICLs with and without such a hole has hitherto been conducted. A prospective, randomized, controlled trial was carried out in order to compare the long-term clinical outcomes of the implantation, in such eyes, of ICLs with and without a central artificial hole.Examinations were conducted of the 64 eyes of 32 consecutive patients with spherical equivalents of -7.53 ± 2.39 diopters (D) (mean ± standard deviation) in whom implantation of a Hole ICL was performed in 1 eye, and that of a conventional ICL was carried out in the other, by randomized assignment. Before 1, 3, and 6 months, and 1, 3, and 5 years after surgery, the safety, efficacy, predictability, stability, intraocular pressure, endothelial cell density, and adverse events of the 2 surgical techniques were assessed and compared over time.The measurements of LogMAR uncorrected and corrected distance visual acuity 5 years postoperatively were -0.17 ± 0.14 and -0.24 ± 0.08 in the Hole ICL group, and -0.16 ± 0.10 and -0.25 ± 0.08 in the conventional ICL group. In these 2 groups, 96% and 100% of eyes, respectively, were within 1.0 D of the targeted correction 5 years postoperatively. Manifest refraction changed by -0.17 ± 0.41 D and -0.10 ± 0.26 D occurred in from 1 month to 5 years in the Hole and conventional ICL groups, respectively. Only 1 eye (3.1%), which was in the conventional ICL group, developed an asymptomatic anterior subcapsular cataract.Both Hole and conventional ICLs corrected of ametropia successfully throughout the 5-year observation period. It appears likely that the presence of the central hole does not significantly affect these visual and refractive outcomes. UMIN000018771.
- 1 April 2016
- Published by Wolters Kluwer Health in Medicine
- Vol. 95 (14) , e3270
Open AccessLong-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic Astigmatism
The study shows a promising next-generation surgical option for the correction of moderate to high ametropia. Hole implantable collamer lens (ICL), STAAR Surgical, is a posterior chamber phakic intraocular lens with a central artificial hole. As yet, however, no long-term comparison of the clinical results of the implantation of ICLs with and without such a hole has hitherto been conducted. A prospective, randomized, controlled trial was carried out in order to compare the long-term clinical outcomes of the implantation, in such eyes, of ICLs with and without a central artificial hole.Examinations were conducted of the 64 eyes of 32 consecutive patients with spherical equivalents of -7.53 ± 2.39 diopters (D) (mean ± standard deviation) in whom implantation of a Hole ICL was performed in 1 eye, and that of a conventional ICL was carried out in the other, by randomized assignment. Before 1, 3, and 6 months, and 1, 3, and 5 years after surgery, the safety, efficacy, predictability, stability, intraocular pressure, endothelial cell density, and adverse events of the 2 surgical techniques were assessed and compared over time.The measurements of LogMAR uncorrected and corrected distance visual acuity 5 years postoperatively were -0.17 ± 0.14 and -0.24 ± 0.08 in the Hole ICL group, and -0.16 ± 0.10 and -0.25 ± 0.08 in the conventional ICL group. In these 2 groups, 96% and 100% of eyes, respectively, were within 1.0 D of the targeted correction 5 years postoperatively. Manifest refraction changed by -0.17 ± 0.41 D and -0.10 ± 0.26 D occurred in from 1 month to 5 years in the Hole and conventional ICL groups, respectively. Only 1 eye (3.1%), which was in the conventional ICL group, developed an asymptomatic anterior subcapsular cataract.Both Hole and conventional ICLs corrected of ametropia successfully throughout the 5-year observation period. It appears likely that the presence of the central hole does not significantly affect these visual and refractive outcomes. UMIN000018771.
- 1 January 2015
- Published by Springer Nature
- p. 75-82
Overview of Clinical Results for Low and Moderate Myopia
- 1 January 2015
- Published by Springer Nature
- p. 75-82
Overview of Clinical Results for Low and Moderate Myopia
- 18 July 2014
- Published by Springer Nature
- p. 59-69
Corneal Astigmatisms and Postoperative Visual Acuity
- 18 July 2014
- Published by Springer Nature
- p. 59-69
Corneal Astigmatisms and Postoperative Visual Acuity
- Open Access
- 1 December 2013
- Published by Springer Nature in BMC Urology
- Vol. 13 (1) , 65
The impact of real-time 3d imaging by ultra-high speed optical coherence tomography in urothelial carcinoma
Optical coherence tomography (OCT) has become a promising diagnostic tool in many medical fields. In particular, noninvasive real-time optical biopsy of internal organs is one of the most attractive applications of OCT, enabling in situ diagnosis of carcinoma at an early stage. We used an ultra-high speed OCT system for real-time three-dimensional (3D) imaging of three excised specimens of advanced urothelial carcinoma (UC) and investigated the association of the images with results from histopathological examination.
- 1 December 2013
- Published by Springer Nature in BMC Urology
- Vol. 13 (1) , 65
Open AccessThe impact of real-time 3d imaging by ultra-high speed optical coherence tomography in urothelial carcinoma
Optical coherence tomography (OCT) has become a promising diagnostic tool in many medical fields. In particular, noninvasive real-time optical biopsy of internal organs is one of the most attractive applications of OCT, enabling in situ diagnosis of carcinoma at an early stage. We used an ultra-high speed OCT system for real-time three-dimensional (3D) imaging of three excised specimens of advanced urothelial carcinoma (UC) and investigated the association of the images with results from histopathological examination.
- 1 September 2012
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 154 (3) , 486-494.e1
Intraindividual Comparison of Visual Performance After Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole Implantation for Moderate to High Myopia
- 1 September 2012
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 154 (3) , 486-494.e1
Intraindividual Comparison of Visual Performance After Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole Implantation for Moderate to High Myopia
- 1 August 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (8) , 1408-1413
Time course of refractive and corneal astigmatism after laser in situ keratomileusis for moderate to high astigmatism
PURPOSE: To assess the time course of refractive and corneal astigmatism after laser in situ keratomileusis (LASIK) in eyes with moderate to high astigmatism. SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, Japan. DESIGN: Retrospective case series. METHODS: Keratometric readings and corneal astigmatism were determined with an autokeratometer in consecutive patients who had LASIK for moderate to high astigmatism (≥2.00 diopters [D]). RESULTS: The study enrolled 48 eyes of 35 patients with a mean age of 34.0 years ± 8.1 (SD), a mean spherical error of −5.10 ± 2.11 D, and a mean cylindrical error of −2.74 ± 0.99 D. Postoperatively, the mean spherical refraction changed significantly from 0.38 ± 0.80 D at 1 week to −0.13 ± 0.90 D at 1 year (P<.001, Wilcoxon signed-rank test). The mean cylindrical refraction showed no significant change (−0.67 ± 0.54 D at 1 week to −0.63 ± 0.63 D at 1 year) (P=.54). There were significant increases in the flattest and steepest keratometry readings at 1 week and at 1 year. However, no significant change in corneal astigmatism was found at either time point (P=.10). CONCLUSIONS: After LASIK, there was significant refractive regression in the spherical component but not in the cylindrical component. This suggests that refractive regression occurs by corneal steepening in the spherical component and that astigmatic regression does not occur, even in moderately to highly astigmatic eyes. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
- 1 August 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (8) , 1408-1413
Time course of refractive and corneal astigmatism after laser in situ keratomileusis for moderate to high astigmatism
PURPOSE: To assess the time course of refractive and corneal astigmatism after laser in situ keratomileusis (LASIK) in eyes with moderate to high astigmatism. SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, Japan. DESIGN: Retrospective case series. METHODS: Keratometric readings and corneal astigmatism were determined with an autokeratometer in consecutive patients who had LASIK for moderate to high astigmatism (≥2.00 diopters [D]). RESULTS: The study enrolled 48 eyes of 35 patients with a mean age of 34.0 years ± 8.1 (SD), a mean spherical error of −5.10 ± 2.11 D, and a mean cylindrical error of −2.74 ± 0.99 D. Postoperatively, the mean spherical refraction changed significantly from 0.38 ± 0.80 D at 1 week to −0.13 ± 0.90 D at 1 year (P<.001, Wilcoxon signed-rank test). The mean cylindrical refraction showed no significant change (−0.67 ± 0.54 D at 1 week to −0.63 ± 0.63 D at 1 year) (P=.54). There were significant increases in the flattest and steepest keratometry readings at 1 week and at 1 year. However, no significant change in corneal astigmatism was found at either time point (P=.10). CONCLUSIONS: After LASIK, there was significant refractive regression in the spherical component but not in the cylindrical component. This suggests that refractive regression occurs by corneal steepening in the spherical component and that astigmatic regression does not occur, even in moderately to highly astigmatic eyes. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
- Open Access
- 16 April 2012
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 6 (1) , 109
Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed. Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.
- 16 April 2012
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 6 (1) , 109
Open AccessSuccessful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed. Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.
- 1 November 2011
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (11) , 826-831
Clinical Outcomes of Photoastigmatic Refractive Keratectomy for the Correction of Residual Refractive Errors Following Cataract Surgery
To assess the clinical outcomes of photoastigmatic refractive keratectomy (PARK) for the correction of residual refractive errors after cataract surgery. This study evaluated 88 eyes of 66 consecutive patients with mean spherical equivalent refraction of -3.16±1.71 diopters (D) who underwent PARK to correct refractive errors after phacoemulsification with intraocular lens (IOL) implantation. Patient age at the time of surgery was 65.2±12.7 years. Safety, efficacy, predictability, stability, and adverse events of the surgery were assessed 1, 3, 6, and 12 months postoperatively. At 1 year postoperatively, uncorrected distance visual acuity and corrected distance visual acuity were 0.08±0.16 logMAR (Snellen 20/25) and -0.08±0.11 logMAR (Snellen 20/16), respectively. Safety and efficacy indices were 1.08±0.25 and 0.76±0.28, respectively. At 1 year, 68% of eyes were within ±0.50 D and 88% were within ±1.00 D of targeted correction. Manifest refraction changes of -0.06±1.06 D occurred from 1 week to 1 year. No vision-threatening complications occurred during the observation period. Photoastigmatic refractive keratectomy is safe and moderately effective in the correction of residual refractive errors in pseudophakic eyes, suggesting its viability as a surgical option for the treatment of such eyes.
- 1 November 2011
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (11) , 826-831
Clinical Outcomes of Photoastigmatic Refractive Keratectomy for the Correction of Residual Refractive Errors Following Cataract Surgery
To assess the clinical outcomes of photoastigmatic refractive keratectomy (PARK) for the correction of residual refractive errors after cataract surgery. This study evaluated 88 eyes of 66 consecutive patients with mean spherical equivalent refraction of -3.16±1.71 diopters (D) who underwent PARK to correct refractive errors after phacoemulsification with intraocular lens (IOL) implantation. Patient age at the time of surgery was 65.2±12.7 years. Safety, efficacy, predictability, stability, and adverse events of the surgery were assessed 1, 3, 6, and 12 months postoperatively. At 1 year postoperatively, uncorrected distance visual acuity and corrected distance visual acuity were 0.08±0.16 logMAR (Snellen 20/25) and -0.08±0.11 logMAR (Snellen 20/16), respectively. Safety and efficacy indices were 1.08±0.25 and 0.76±0.28, respectively. At 1 year, 68% of eyes were within ±0.50 D and 88% were within ±1.00 D of targeted correction. Manifest refraction changes of -0.06±1.06 D occurred from 1 week to 1 year. No vision-threatening complications occurred during the observation period. Photoastigmatic refractive keratectomy is safe and moderately effective in the correction of residual refractive errors in pseudophakic eyes, suggesting its viability as a surgical option for the treatment of such eyes.
- Open Access
- 6 July 2011
- Published by BMJ in British Journal of Ophthalmology
- Vol. 96 (3) , 409-412
Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopia
Aim To assess the early clinical outcomes of an ICL with a central hole (Hole ICL) implantation for the correction of moderate to high myopia. Methods This study evaluated 20 eyes of 20 patients with spherical equivalents of −7.36±2.13 D (mean±SD) who underwent Hole ICL implantation. Before surgery and at 1 week and 1, 3 and 6 months after surgery, we assessed the safety, efficacy, predictability, stability and adverse events of the surgery. Results Logarithm of the minimum angle of resolution (logMAR) uncorrected visual acuity and logMAR best spectacle-corrected visual acuity were −0.20±0.12 and −0.25±0.06, respectively, 6 months after surgery. The safety and efficacy indices were 1.13±0.24 and 1.03±0.30, respectively. At 6 months, 95%, and 100% eyes were within ±0.5 and ±1.0 D of the targeted correction, respectively. Change in manifest refraction from week 1 to month 6 was 0.06±0.28 D. No significant rise in intraocular pressure (including pupillary block) or a secondary cataract occurred in any case during the period of observation. Conclusions Implantation of a newly developed Hole ICL offered good results for all measures of safety, efficacy, predictability and stability for the correction of moderate to high myopic errors, even without peripheral iridectomy, suggesting its viability as a surgical option for the treatment of such eyes.
- 6 July 2011
- Published by BMJ in British Journal of Ophthalmology
- Vol. 96 (3) , 409-412
Open AccessEarly clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopia
Aim To assess the early clinical outcomes of an ICL with a central hole (Hole ICL) implantation for the correction of moderate to high myopia. Methods This study evaluated 20 eyes of 20 patients with spherical equivalents of −7.36±2.13 D (mean±SD) who underwent Hole ICL implantation. Before surgery and at 1 week and 1, 3 and 6 months after surgery, we assessed the safety, efficacy, predictability, stability and adverse events of the surgery. Results Logarithm of the minimum angle of resolution (logMAR) uncorrected visual acuity and logMAR best spectacle-corrected visual acuity were −0.20±0.12 and −0.25±0.06, respectively, 6 months after surgery. The safety and efficacy indices were 1.13±0.24 and 1.03±0.30, respectively. At 6 months, 95%, and 100% eyes were within ±0.5 and ±1.0 D of the targeted correction, respectively. Change in manifest refraction from week 1 to month 6 was 0.06±0.28 D. No significant rise in intraocular pressure (including pupillary block) or a secondary cataract occurred in any case during the period of observation. Conclusions Implantation of a newly developed Hole ICL offered good results for all measures of safety, efficacy, predictability and stability for the correction of moderate to high myopic errors, even without peripheral iridectomy, suggesting its viability as a surgical option for the treatment of such eyes.