Johann Nicolics
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Johann Nicolics has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Ephraim Suhir
Portland State University
6 shared publications Paul Fulmek
3 shared publications- Reza Ghaffarian
California Institute of Technology
3 shared publications W. Smetana
3 shared publications- Franz Peter Wenzl
Institute of Surface Technologies and Photonics JOANNEUM Research Forschungsgesm.b.H, 7423 Pinkafeld, Austria
2 shared publications - Gregor Langer
Research Ctr. for Non Destructive Testing GmbH (Austria)
2 shared publications
Latest Publications
- 1 January 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 116, 1096-1107
Analysis of the local temperature distribution in color conversion elements of phosphor converted light-emitting diodes
- 1 January 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 116, 1096-1107
Analysis of the local temperature distribution in color conversion elements of phosphor converted light-emitting diodes
- Open Access
- 30 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 9964
On the determination of the temperature distribution within the color conversion elements of phosphor converted LEDs
We present an iterative optical and thermal simulation procedure which enables the determination of the temperature distribution in the phosphor layer of a phosphor converted LED with good accuracy. Using the simulation both the highest phosphor temperatures, which are mostly relevant to material degradation as well as the temperatures of those phosphor particles which mainly contribute to converted light emission can be determined. We compare the simulations with experimental studies on the phosphor temperature. While infrared thermography only gives information on the phosphor layer surface temperature, phosphor thermometry provides temperature data on the volume temperature of the phosphor layer relevant to color conversion.
- 30 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 9964
Open AccessOn the determination of the temperature distribution within the color conversion elements of phosphor converted LEDs
We present an iterative optical and thermal simulation procedure which enables the determination of the temperature distribution in the phosphor layer of a phosphor converted LED with good accuracy. Using the simulation both the highest phosphor temperatures, which are mostly relevant to material degradation as well as the temperatures of those phosphor particles which mainly contribute to converted light emission can be determined. We compare the simulations with experimental studies on the phosphor temperature. While infrared thermography only gives information on the phosphor layer surface temperature, phosphor thermometry provides temperature data on the volume temperature of the phosphor layer relevant to color conversion.
- Open Access
- 1 March 2017
- Published by AIP Publishing in AIP Advances
- Vol. 7 (3) , 035206
Time dependent and temperature dependent properties of the forward voltage characteristic of InGaN high power LEDs
Estimating the junction temperature and its dynamic behavior in dependence of various operating conditions is an important issue, since these properties influence the optical characteristics as well as the aging processes of a light-emitting diode (LED). Particularly for high-power LEDs and pulsed operation, the dynamic behavior and the resulting thermal cycles are of interest. The forward voltage method relies on the existence of a time-independent unique triple of forward-voltage, forward-current, and junction temperature. These three figures should as well uniquely define the optical output power and spectrum, as well as the loss power of the LED, which is responsible for an increase of the junction temperature. From transient FEM-simulations one may expect an increase of the temperature of the active semiconductor layer of some 1/10 K within the first 10 μs. Most of the well-established techniques for junction temperature measurement via forward voltage method evaluate the measurement data several dozens of microseconds after switching on or switching off and estimate the junction temperature by extrapolation towards the time of switching. In contrast, the authors developed a measurement procedure with the focus on the first microseconds after switching. Besides a fast data acquisition system, a precise control of the switching process is required, i.e. a precisely defined current pulse amplitude with fast rise-time and negligible transient by-effects. We start with a short description of the measurement setup and the newly developed control algorithm for the generation of short current pulses. The thermal characterization of the LED chip during the measurement procedures is accomplished by an IR thermography system and transient finite element simulations. The same experimental setup is used to investigate the optical properties of the LED in an Ulbricht-sphere. Our experiments are performed on InGaN LED chips mounted on an Al based insulated metal substrate (IMS), giving a comprehensive picture of the transient behavior of the forward voltage of this type of high power LED.
- 1 March 2017
- Published by AIP Publishing in AIP Advances
- Vol. 7 (3) , 035206
Open AccessTime dependent and temperature dependent properties of the forward voltage characteristic of InGaN high power LEDs
Estimating the junction temperature and its dynamic behavior in dependence of various operating conditions is an important issue, since these properties influence the optical characteristics as well as the aging processes of a light-emitting diode (LED). Particularly for high-power LEDs and pulsed operation, the dynamic behavior and the resulting thermal cycles are of interest. The forward voltage method relies on the existence of a time-independent unique triple of forward-voltage, forward-current, and junction temperature. These three figures should as well uniquely define the optical output power and spectrum, as well as the loss power of the LED, which is responsible for an increase of the junction temperature. From transient FEM-simulations one may expect an increase of the temperature of the active semiconductor layer of some 1/10 K within the first 10 μs. Most of the well-established techniques for junction temperature measurement via forward voltage method evaluate the measurement data several dozens of microseconds after switching on or switching off and estimate the junction temperature by extrapolation towards the time of switching. In contrast, the authors developed a measurement procedure with the focus on the first microseconds after switching. Besides a fast data acquisition system, a precise control of the switching process is required, i.e. a precisely defined current pulse amplitude with fast rise-time and negligible transient by-effects. We start with a short description of the measurement setup and the newly developed control algorithm for the generation of short current pulses. The thermal characterization of the LED chip during the measurement procedures is accomplished by an IR thermography system and transient finite element simulations. The same experimental setup is used to investigate the optical properties of the LED in an Ulbricht-sphere. Our experiments are performed on InGaN LED chips mounted on an Al based insulated metal substrate (IMS), giving a comprehensive picture of the transient behavior of the forward voltage of this type of high power LED.
- 25 November 2015
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 27 (3) , 2430-2441
Predicted stresses in ball-grid-array (BGA) and column-grid-array (CGA) interconnections in a mirror-like package design
- 25 November 2015
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 27 (3) , 2430-2441
Predicted stresses in ball-grid-array (BGA) and column-grid-array (CGA) interconnections in a mirror-like package design
- 28 October 2015
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 27 (1) , 570-579
Could thermal stresses in a BGA/CGA-system be evaluated from a model intended for a homogeneously bonded assembly?
- 28 October 2015
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 27 (1) , 570-579
Could thermal stresses in a BGA/CGA-system be evaluated from a model intended for a homogeneously bonded assembly?
- 7 September 2015
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 26 (12) , 10062-10067
Could application of column-grid-array (CGA) technology result in inelastic-strain-free state-of-stress in solder material?
- 7 September 2015
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 26 (12) , 10062-10067
Could application of column-grid-array (CGA) technology result in inelastic-strain-free state-of-stress in solder material?
- Open Access
- 8 November 2014
- Published by Springer Nature in Journal of Solid State Lighting
- Vol. 1 (1) , 18
A comprehensive discussion on colour conversion element design of phosphor converted LEDs
For a systematic approach to improve the white light quality of phosphor converted light-emitting diodes (LEDs) for general lighting applications it is imperative to get the individual sources of error for correlated colour temperature (CCT) reproducibility and maintenance under control. In this regard, it is of essential importance to understand how geometrical, optical and thermal properties of the colour conversion elements (CCEs), which typically consist of phosphor particles embedded in a transparent matrix material, affect the constancy of a desired CCT value. In this contribution we use an LED assembly consisting of an LED die mounted on a printed circuit board by chip-on-board technology and a CCE with a globe-top configuration on the top of it as a model system and discuss the impact of the CCE size, the substrate reflectivity as well as the thermal load of the CCEs on CCT maintenance and the respective radiant fluxes. It turns out that optimized solutions for CCT maintenance and high radiant fluxes in regard of one of the relevant influence factors do not need to be optimized solutions in regard of another one.
- 8 November 2014
- Published by Springer Nature in Journal of Solid State Lighting
- Vol. 1 (1) , 18
Open AccessA comprehensive discussion on colour conversion element design of phosphor converted LEDs
For a systematic approach to improve the white light quality of phosphor converted light-emitting diodes (LEDs) for general lighting applications it is imperative to get the individual sources of error for correlated colour temperature (CCT) reproducibility and maintenance under control. In this regard, it is of essential importance to understand how geometrical, optical and thermal properties of the colour conversion elements (CCEs), which typically consist of phosphor particles embedded in a transparent matrix material, affect the constancy of a desired CCT value. In this contribution we use an LED assembly consisting of an LED die mounted on a printed circuit board by chip-on-board technology and a CCE with a globe-top configuration on the top of it as a model system and discuss the impact of the CCE size, the substrate reflectivity as well as the thermal load of the CCEs on CCT maintenance and the respective radiant fluxes. It turns out that optimized solutions for CCT maintenance and high radiant fluxes in regard of one of the relevant influence factors do not need to be optimized solutions in regard of another one.
- 26 September 2014
- Published by Wiley in Journal of Applied Mechanics
- Vol. 81 (11) , 114502
Analysis of a Bow-Free Prestressed Test Specimen
Broadening the temperature range in accelerated testing of electronic products is a typical measure to assure that the product of interest is sufficiently robust. At the same time, a too broad temperature range can lead to the shift in the modes and mechanisms of failure, i.e., result in failures that will not occur in actual operation conditions. Application of mechanical prestressing of the test specimen could be an effective means for narrowing the temperature range during accelerated testing and thereby achieving trustworthy and failure-mode-shift-free accelerated test information. Accordingly, simple engineering predictive models are developed for the evaluation of the magnitude and the distribution of thermal and mechanical stresses in a prestressed bow-free test specimen. A design, in which an electronic or a photonic package is bonded between two identical substrates, is considered. Such a design is often employed in some today's packaging systems, in which the “inner,” functional, component containing active and/or passive devices and interconnects is placed between two identical “outer” components (substrates). The addressed stresses include normal stresses acting in the component cross sections and the interfacial shearing and peeling stresses. Although the specimen as a whole remains bow-free, the peeling stresses might be nevertheless appreciable, since the outer components, if thin enough, deflect to a greater or lesser extent with respect to the inner component. The numerical example has indicated that the maxima of the interfacial thermal shearing and peeling stresses are indeed comparable and that these maxima are on the same order of magnitude as the normal thermal stresses acting in the components' cross sections. It is shown that since the thermal and the prestressing mechanical loads are of different physical nature, the stresses caused by these two load categories are distributed differently over the specimen's length. It is shown also that although it is possible and even advisable to apply mechanical prestressing for a lower temperature range, it is impossible to reproduce the same stress distribution as in the case of thermal loading. The obtained results enable one to shed light on the physics of the state of stress in prestressed bow-free test specimens in electronics and photonics engineering.
- 26 September 2014
- Published by Wiley in Journal of Applied Mechanics
- Vol. 81 (11) , 114502
Analysis of a Bow-Free Prestressed Test Specimen
Broadening the temperature range in accelerated testing of electronic products is a typical measure to assure that the product of interest is sufficiently robust. At the same time, a too broad temperature range can lead to the shift in the modes and mechanisms of failure, i.e., result in failures that will not occur in actual operation conditions. Application of mechanical prestressing of the test specimen could be an effective means for narrowing the temperature range during accelerated testing and thereby achieving trustworthy and failure-mode-shift-free accelerated test information. Accordingly, simple engineering predictive models are developed for the evaluation of the magnitude and the distribution of thermal and mechanical stresses in a prestressed bow-free test specimen. A design, in which an electronic or a photonic package is bonded between two identical substrates, is considered. Such a design is often employed in some today's packaging systems, in which the “inner,” functional, component containing active and/or passive devices and interconnects is placed between two identical “outer” components (substrates). The addressed stresses include normal stresses acting in the component cross sections and the interfacial shearing and peeling stresses. Although the specimen as a whole remains bow-free, the peeling stresses might be nevertheless appreciable, since the outer components, if thin enough, deflect to a greater or lesser extent with respect to the inner component. The numerical example has indicated that the maxima of the interfacial thermal shearing and peeling stresses are indeed comparable and that these maxima are on the same order of magnitude as the normal thermal stresses acting in the components' cross sections. It is shown that since the thermal and the prestressing mechanical loads are of different physical nature, the stresses caused by these two load categories are distributed differently over the specimen's length. It is shown also that although it is possible and even advisable to apply mechanical prestressing for a lower temperature range, it is impossible to reproduce the same stress distribution as in the case of thermal loading. The obtained results enable one to shed light on the physics of the state of stress in prestressed bow-free test specimens in electronics and photonics engineering.
- 16 December 2010
- Published by Wiley in ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik
- Vol. 91 (4) , 330-338
Analysis of an elongated stretched strip, with application to a strain-gage electrical sensor design
- 16 December 2010
- Published by Wiley in ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik
- Vol. 91 (4) , 330-338
Analysis of an elongated stretched strip, with application to a strain-gage electrical sensor design