Kazuyuki Araki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kazuyuki Araki has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Yukiko Matsuda
Division of Radiology, Department of Oral Diagnostic Sciences, Showa University School of Dentistry, 2-1-1 Kitasenzoku, Ohta-ku, Tokyo 145-8515, Japan
4 shared publications - Emi Ito
Division of Radiology, Department of Oral Diagnostic Sciences, Showa University School of Dentistry, 2-1-1 Kitasenzoku, Ohta-ku, Tokyo 145-8515, Japan
3 shared publications A Endo
2 shared publicationsMamiko Fujikura
Department of Oral Diagnostic Sciences, Division of Pathology, Showa University School of Dentistry
2 shared publications- Migiwa Kuroda
Division of Radiology, Department of Oral Diagnostic Sciences, Showa University School of Dentistry, 2-1-1 Kitasenzoku, Ohta-ku, Tokyo 145-8515, Japan
2 shared publications - Mohammad Khursheed Alam
Department of Preventive Dentistry, Jouf University, Sakakah, Saudi Arabia
2 shared publications
Latest Publications
- Open Access
- 26 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 240
Changes in Maxillary Sinus Structure Due to Tooth Loss and the Effects of Sex and Aging on CBCT Before Maxillary Sinus Augmentation: A Cross-Sectional Study of 120 Patients
Prosthesis for missing maxillary molars with dental implants often requires maxillary sinus augmentation owing to insufficient alveolar bone height. However, the anatomical structure of the maxillary sinus is a significant risk factor. This study used preoperative cone-beam computed tomography (CBCT) to investigate changes in the anatomical structure of the maxillary sinus due to tooth loss and conducted an epidemiological survey of Japanese people to determine the effects of gender and age on these changes. Preoperative CBCT scans were analyzed in patients aged ≥ 50 years with free-end maxillary molar edentulism involving ≥ 2 missing teeth seeking implant treatment. Statistical analyses were performed. One hundred and twenty participants (46 males, 74 females; mean age, 62.1 ± 7.4 years) with 3.0 ± 0.9 missing teeth and an existing bone volume of 6.2 ± 3.1 mm were included. Lateral wall thickness, sinus angle, sinus membrane thickness, maxillary sinus length and width, and the presence of the sinus septa significantly differed between missing and non-missing sides. Maxillary sinus height and sinus membrane thickness on missing side and maxillary sinus height and width on non-missing side varied significantly. Aging was associated with maxillary sinus length and width changes on the non-missing side in males, whereas no age-associated effects were identified in females. To ensure the safe execution of maxillary sinus augmentation, a thorough understanding of maxillary sinus anatomy is crucial prior to surgery.
- 26 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 240
Open AccessChanges in Maxillary Sinus Structure Due to Tooth Loss and the Effects of Sex and Aging on CBCT Before Maxillary Sinus Augmentation: A Cross-Sectional Study of 120 Patients
Prosthesis for missing maxillary molars with dental implants often requires maxillary sinus augmentation owing to insufficient alveolar bone height. However, the anatomical structure of the maxillary sinus is a significant risk factor. This study used preoperative cone-beam computed tomography (CBCT) to investigate changes in the anatomical structure of the maxillary sinus due to tooth loss and conducted an epidemiological survey of Japanese people to determine the effects of gender and age on these changes. Preoperative CBCT scans were analyzed in patients aged ≥ 50 years with free-end maxillary molar edentulism involving ≥ 2 missing teeth seeking implant treatment. Statistical analyses were performed. One hundred and twenty participants (46 males, 74 females; mean age, 62.1 ± 7.4 years) with 3.0 ± 0.9 missing teeth and an existing bone volume of 6.2 ± 3.1 mm were included. Lateral wall thickness, sinus angle, sinus membrane thickness, maxillary sinus length and width, and the presence of the sinus septa significantly differed between missing and non-missing sides. Maxillary sinus height and sinus membrane thickness on missing side and maxillary sinus height and width on non-missing side varied significantly. Aging was associated with maxillary sinus length and width changes on the non-missing side in males, whereas no age-associated effects were identified in females. To ensure the safe execution of maxillary sinus augmentation, a thorough understanding of maxillary sinus anatomy is crucial prior to surgery.
- Open Access
A Basic Study for Predicting Dysphagia in Panoramic X-ray Images Using Artificial Intelligence (AI) Part 2: Analysis of the Position of the Hyoid Bone on Panoramic Radiographs
Background: Oral frailty is associated with systemic frailty. The vertical position of the hyoid bone is important when considering the risk of dysphagia. However, dentists usually do not focus on this position. Purpose: To create an AI model for detection of the position of the vertical hyoid bone. Methods: In this study, 1830 hyoid bone images from 915 panoramic radiographs were used for AI learning. The position of the hyoid bone was classified into six types (Types 0, 1, 2, 3, 4, and 5) based on the same criteria as in our previous study. Plan 1 learned all types. In Plan 2, the five types other than Type 0 were learned. To reduce the number of groupings, three classes were formed using combinations of two types in each class. Plan 3 was used for learning all three classes, and Plan 4 was used for learning the two classes other than Class A (Types 0 and 1). Precision, recall, f-values, accuracy, and areas under the precision–recall curves (PR-AUCs) were calculated and comparatively evaluated. Results: Plan 4 showed the highest accuracy and PR-AUC values, of 0.93 and 0.97, respectively. Conclusions: By reducing the number of classes and not learning cases in which the anatomical structure was partially invisible, the vertical hyoid bone was correctly detected.
Open AccessA Basic Study for Predicting Dysphagia in Panoramic X-ray Images Using Artificial Intelligence (AI) Part 2: Analysis of the Position of the Hyoid Bone on Panoramic Radiographs
Background: Oral frailty is associated with systemic frailty. The vertical position of the hyoid bone is important when considering the risk of dysphagia. However, dentists usually do not focus on this position. Purpose: To create an AI model for detection of the position of the vertical hyoid bone. Methods: In this study, 1830 hyoid bone images from 915 panoramic radiographs were used for AI learning. The position of the hyoid bone was classified into six types (Types 0, 1, 2, 3, 4, and 5) based on the same criteria as in our previous study. Plan 1 learned all types. In Plan 2, the five types other than Type 0 were learned. To reduce the number of groupings, three classes were formed using combinations of two types in each class. Plan 3 was used for learning all three classes, and Plan 4 was used for learning the two classes other than Class A (Types 0 and 1). Precision, recall, f-values, accuracy, and areas under the precision–recall curves (PR-AUCs) were calculated and comparatively evaluated. Results: Plan 4 showed the highest accuracy and PR-AUC values, of 0.93 and 0.97, respectively. Conclusions: By reducing the number of classes and not learning cases in which the anatomical structure was partially invisible, the vertical hyoid bone was correctly detected.
- Open Access
- 9 April 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (8) , 4529
A Basic Study for Predicting Dysphagia in Panoramic X-ray Images Using Artificial Intelligence (AI)—Part 1: Determining Evaluation Factors and Cutoff Levels
Background: Dysphagia relates to quality of life; this disorder is related to the difficulties of dental treatment. Purpose: To detect radiographic signs of dysphagia by using panoramic radiograph with an AI system. Methods: Seventy-seven patients who underwent a panoramic radiograph and a videofluorographic swallowing study were analyzed. Age, gender, the number of remaining teeth, the distance between the tongue and the palate, the vertical and horizontal hyoid bone position, and the width of the tongue were analyzed. Logistic regression analysis was used. For the statistically significant factors, the cutoff level was determined. The cutoff level was determined by using analysis of the receiver operations characteristic (ROC) curve and the Youden Index. Results: A significant relationship with presence of dysphagia was only observed for the vertical hyoid bone position. The area under the curve (AUC) was 0.72. The cutoff level decided for the hyoid bone was observed to be lower than the mandibular border line. Conclusions: In cases where the hyoid bone is lower than the mandibular border line on a panoramic radiograph, it suggests the risk of dysphagia would be high. We will create an AI model for the detection of the risk of dysphagia by using the assessment of vertical hyoid bone position.
- 9 April 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (8) , 4529
Open AccessA Basic Study for Predicting Dysphagia in Panoramic X-ray Images Using Artificial Intelligence (AI)—Part 1: Determining Evaluation Factors and Cutoff Levels
Background: Dysphagia relates to quality of life; this disorder is related to the difficulties of dental treatment. Purpose: To detect radiographic signs of dysphagia by using panoramic radiograph with an AI system. Methods: Seventy-seven patients who underwent a panoramic radiograph and a videofluorographic swallowing study were analyzed. Age, gender, the number of remaining teeth, the distance between the tongue and the palate, the vertical and horizontal hyoid bone position, and the width of the tongue were analyzed. Logistic regression analysis was used. For the statistically significant factors, the cutoff level was determined. The cutoff level was determined by using analysis of the receiver operations characteristic (ROC) curve and the Youden Index. Results: A significant relationship with presence of dysphagia was only observed for the vertical hyoid bone position. The area under the curve (AUC) was 0.72. The cutoff level decided for the hyoid bone was observed to be lower than the mandibular border line. Conclusions: In cases where the hyoid bone is lower than the mandibular border line on a panoramic radiograph, it suggests the risk of dysphagia would be high. We will create an AI model for the detection of the risk of dysphagia by using the assessment of vertical hyoid bone position.
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
- Vol. 21
Tooth Coronal Index: A Novel Tool For Age Estimation on Cone-Beam Computed Tomography
Objective: To evaluate dental age assessment reliability through Tooth Coronal Index (TCI) method. Material and Methods: The cone-beam computed tomography (CBCT) scans of 160 individuals aged between 20-70 years were analyzed in the present study. The height of the crown, i.e., coronal height, and the height of the coronal pulp cavity, i.e., coronal pulp cavity height, of mandibular second premolars and first molars were calculated and then TCI was measured. The actual age of a subject was compared with TCI of tooth and the acquired data were subjected to Pearson’s correlation and unpaired t-tests. Results: Negative correlation was observed between the real age and TCI of mandibular first molar (r = -0.094, p=0.382) and second premolar (r = -0.176, p=0.0961. Statistically significant difference was observed between actual age and TCI for mandibular second premolar and first molar (p<0.001). Conclusion: Tooth coronal index has the potential to estimate age of an individual on CBCT scans. It is simple, cost-effective than histological methods and can be applied to both living and unknown dead.
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
- Vol. 21
Open AccessTooth Coronal Index: A Novel Tool For Age Estimation on Cone-Beam Computed Tomography
Objective: To evaluate dental age assessment reliability through Tooth Coronal Index (TCI) method. Material and Methods: The cone-beam computed tomography (CBCT) scans of 160 individuals aged between 20-70 years were analyzed in the present study. The height of the crown, i.e., coronal height, and the height of the coronal pulp cavity, i.e., coronal pulp cavity height, of mandibular second premolars and first molars were calculated and then TCI was measured. The actual age of a subject was compared with TCI of tooth and the acquired data were subjected to Pearson’s correlation and unpaired t-tests. Results: Negative correlation was observed between the real age and TCI of mandibular first molar (r = -0.094, p=0.382) and second premolar (r = -0.176, p=0.0961. Statistically significant difference was observed between actual age and TCI for mandibular second premolar and first molar (p<0.001). Conclusion: Tooth coronal index has the potential to estimate age of an individual on CBCT scans. It is simple, cost-effective than histological methods and can be applied to both living and unknown dead.
- Open Access
Diagnosis of Occlusal Caries with Dynamic Slicing of 3D Optical Coherence Tomography Images
Detecting the extent of occlusal caries is a clinically important but challenging task required for treatment decision making. The aim of this study was to assess the diagnostic power of 3D swept-source optical coherence tomography (OCT) for evaluation of occlusal caries in comparison with X-ray radiography. Extracted human molars not exhibiting American Dental Association (ADA) criteria advanced caries were mounted in a silicone block and digital dental radiographs were captured from the buccal side. Subsequently, occlusal surfaces were scanned with a prototype Yoshida Dental OCT. Thirteen examiners evaluated the presence and extent of caries on radiographs and dynamically sliced 3D OCT video images, using a 4 level scale—0: intact; 1: enamel demineralization without cavitation; 2: enamel caries with cavitation; 3: dentin caries with or without cavitation. Sensitivity, specificity and area under operating characteristic curves (Az) were statistically analyzed (α = 0.05). Reliability analysis showed an excellent agreement among the 13 examiners for both methods. The OCT presented a significantly higher sensitivity and Az value for the detection of caries compared to radiographs (p < 0.05). Radiography showed especially low sensitivity for dentin caries (0–2 versus 3). Dynamic slicing of 3D OCT volumes is a powerful adjunct tool to visual inspection to diagnose the dentin occlusal caries in vitro.
Open AccessDiagnosis of Occlusal Caries with Dynamic Slicing of 3D Optical Coherence Tomography Images
Detecting the extent of occlusal caries is a clinically important but challenging task required for treatment decision making. The aim of this study was to assess the diagnostic power of 3D swept-source optical coherence tomography (OCT) for evaluation of occlusal caries in comparison with X-ray radiography. Extracted human molars not exhibiting American Dental Association (ADA) criteria advanced caries were mounted in a silicone block and digital dental radiographs were captured from the buccal side. Subsequently, occlusal surfaces were scanned with a prototype Yoshida Dental OCT. Thirteen examiners evaluated the presence and extent of caries on radiographs and dynamically sliced 3D OCT video images, using a 4 level scale—0: intact; 1: enamel demineralization without cavitation; 2: enamel caries with cavitation; 3: dentin caries with or without cavitation. Sensitivity, specificity and area under operating characteristic curves (Az) were statistically analyzed (α = 0.05). Reliability analysis showed an excellent agreement among the 13 examiners for both methods. The OCT presented a significantly higher sensitivity and Az value for the detection of caries compared to radiographs (p < 0.05). Radiography showed especially low sensitivity for dentin caries (0–2 versus 3). Dynamic slicing of 3D OCT volumes is a powerful adjunct tool to visual inspection to diagnose the dentin occlusal caries in vitro.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
- Vol. 20
Frequency and Characteristics of Mesiodens in Indian School Children: A Retrospective Radiographic Study
Objective: To determine the frequency and characteristics of mesiodens in Indian school children. Material and Methods: 1232 radiographs of patients attending the Department of Oral Medicine and Radiology of the age group of 4-15 years studied for the present retrospective study. The intraoral periapical radiographs and occlusal radiographs of the premaxilla were examined to determine the presence of mesiodens. The data regarding the presence of mesiodens, number, position, location on the arch, shape and associated complications were recorded. Results: Eleven patients had 14 mesiodens, with a frequency of 0.8%. The ratio of boys to girls was 1.2:1. Maximum mesiodens observed in the age group of 7-9 years. Most of the mesiodens were conical in shape and found on the palatal side. Fifty percent of the mesiodens were unerupted. The majority of patients (57.1%) had vertically positioned mesiodens. Midline diastema was the most common complication due to mesiodens (66.7%). Conclusion: Routine check-up during the primary dentition and mixed dentition stages helps for early detection of mesiodens and thus preventing complications. Early identification is useful for planning comprehensive management, initiating proper consultation and referral for evaluation and treatment.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
- Vol. 20
Open AccessFrequency and Characteristics of Mesiodens in Indian School Children: A Retrospective Radiographic Study
Objective: To determine the frequency and characteristics of mesiodens in Indian school children. Material and Methods: 1232 radiographs of patients attending the Department of Oral Medicine and Radiology of the age group of 4-15 years studied for the present retrospective study. The intraoral periapical radiographs and occlusal radiographs of the premaxilla were examined to determine the presence of mesiodens. The data regarding the presence of mesiodens, number, position, location on the arch, shape and associated complications were recorded. Results: Eleven patients had 14 mesiodens, with a frequency of 0.8%. The ratio of boys to girls was 1.2:1. Maximum mesiodens observed in the age group of 7-9 years. Most of the mesiodens were conical in shape and found on the palatal side. Fifty percent of the mesiodens were unerupted. The majority of patients (57.1%) had vertically positioned mesiodens. Midline diastema was the most common complication due to mesiodens (66.7%). Conclusion: Routine check-up during the primary dentition and mixed dentition stages helps for early detection of mesiodens and thus preventing complications. Early identification is useful for planning comprehensive management, initiating proper consultation and referral for evaluation and treatment.
- 1 December 2018
- Published by Taylor & Francis in Orthodontic Waves
- Vol. 77 (4) , 226-231
Hyoid bone position related to gender and aging using lateral cephalometric radiographs
- 1 December 2018
- Published by Taylor & Francis in Orthodontic Waves
- Vol. 77 (4) , 226-231
Hyoid bone position related to gender and aging using lateral cephalometric radiographs
- 1 January 2017
- Published by The Showa University Society in The Showa University Journal of Medical Sciences
- Vol. 29 (4) , 415-423
Magnetic Resonance Imaging Signal Intensities of the Temporomandibular Joint Articular Disc and Cortical Bone: Are These Measurements Valid for the Diagnosis of Temporomandibular Joint Disease?
- 1 January 2017
- Published by The Showa University Society in The Showa University Journal of Medical Sciences
- Vol. 29 (4) , 415-423
Magnetic Resonance Imaging Signal Intensities of the Temporomandibular Joint Articular Disc and Cortical Bone: Are These Measurements Valid for the Diagnosis of Temporomandibular Joint Disease?
- 18 January 2015
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 19 (8) , 1875-1879
Effect of display monitor devices on intra-oral radiographic caries diagnosis
Recent developments in digital computer technology have enabled radiological diagnosis to be performed using a monitor screen. In medical radiography, the importance of monitors has been shown in many diseases. Digital imaging and communication in medicine (DICOM)-compatible monitors are widely used. However, the effect of monitors on the diagnosis of oral disease has not yet been clarified and remains controversial. The aims of this study are to compare the caries diagnostic ability between DICOM monitors and other monitors and to examine if monitor capability affects the diagnosis. One hundred proximal surfaces of 50 extracted human upper premolar teeth were used as specimens. Intra-oral radiographs of all specimens were taken digitally. Three types of monitors were compared in terms of caries diagnostic ability: a DICOM standard-compatible monitor, a standardized personal computer (PC) monitor, and a tablet PC. Six oral radiologists diagnosed each radiograph independently. Areas under the receiver operating characteristic (ROC) curve were generated and compared. Area under the ROC curve (AUC) of the DICOM monitor, PC monitor, and tablet PC was 0.68147, 0.67002, and 0.60189, respectively. There was no significant difference between the DICOM monitor and the PC monitor, but the tablet PC showed significantly lower accuracy. There were no significant differences among the monitors for dentin caries (p > 0.05). DICOM-compatible monitors and PC monitors have similar capabilities, but tablet PCs showed lower diagnostic accuracy, especially for superficial caries. Appropriate monitors are needed for radiographic diagnosis on monitor screens.
- 18 January 2015
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 19 (8) , 1875-1879
Effect of display monitor devices on intra-oral radiographic caries diagnosis
Recent developments in digital computer technology have enabled radiological diagnosis to be performed using a monitor screen. In medical radiography, the importance of monitors has been shown in many diseases. Digital imaging and communication in medicine (DICOM)-compatible monitors are widely used. However, the effect of monitors on the diagnosis of oral disease has not yet been clarified and remains controversial. The aims of this study are to compare the caries diagnostic ability between DICOM monitors and other monitors and to examine if monitor capability affects the diagnosis. One hundred proximal surfaces of 50 extracted human upper premolar teeth were used as specimens. Intra-oral radiographs of all specimens were taken digitally. Three types of monitors were compared in terms of caries diagnostic ability: a DICOM standard-compatible monitor, a standardized personal computer (PC) monitor, and a tablet PC. Six oral radiologists diagnosed each radiograph independently. Areas under the receiver operating characteristic (ROC) curve were generated and compared. Area under the ROC curve (AUC) of the DICOM monitor, PC monitor, and tablet PC was 0.68147, 0.67002, and 0.60189, respectively. There was no significant difference between the DICOM monitor and the PC monitor, but the tablet PC showed significantly lower accuracy. There were no significant differences among the monitors for dentin caries (p > 0.05). DICOM-compatible monitors and PC monitors have similar capabilities, but tablet PCs showed lower diagnostic accuracy, especially for superficial caries. Appropriate monitors are needed for radiographic diagnosis on monitor screens.
- 1 August 2013
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 42 (8) , 20120445
Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom
Objectives:The SEDENTEXCT Project proposed quality assurance (QA) methods and introduced a QA image quality phantom. A new prototype was recently introduced that may be improved according to previous reports. The purpose of this study is to evaluate image quality in various protocols of three cone beam CT (CBCT) machines using the proposed QA phantom.Methods:Using three CBCT machines, nine image quality parameters, including image homogeneity (noise), uniformity, geometrical distortion, pixel intensity value, contrast resolution, spatial resolution [line pair (LP) chart, point spread function (PSF) and modulation transfer function (MTF)] and metal artefacts, were evaluated using a QA phantom proposed by SEDENTEXCT. Exposure parameters, slice thickness and field of view position changed variously, and the number of total protocols was 22.Results:Many protocols showed a uniform gray value distribution except in the minimum slice thickness image acquired using 3D Accuitomo 80 (Morita, Kyoto, Japan) and Verav...
- 1 August 2013
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 42 (8) , 20120445
Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom
Objectives:The SEDENTEXCT Project proposed quality assurance (QA) methods and introduced a QA image quality phantom. A new prototype was recently introduced that may be improved according to previous reports. The purpose of this study is to evaluate image quality in various protocols of three cone beam CT (CBCT) machines using the proposed QA phantom.Methods:Using three CBCT machines, nine image quality parameters, including image homogeneity (noise), uniformity, geometrical distortion, pixel intensity value, contrast resolution, spatial resolution [line pair (LP) chart, point spread function (PSF) and modulation transfer function (MTF)] and metal artefacts, were evaluated using a QA phantom proposed by SEDENTEXCT. Exposure parameters, slice thickness and field of view position changed variously, and the number of total protocols was 22.Results:Many protocols showed a uniform gray value distribution except in the minimum slice thickness image acquired using 3D Accuitomo 80 (Morita, Kyoto, Japan) and Verav...