Stefan G. Ruehm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefan G. Ruehm has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Susanne C. Goehde
Department of Diagnostic and Interventional Radiology, University Hospital Essen, Essen, Germany
2 shared publications- Adam N. Plotnik
Division of Interventional Radiology, Department of Radiology, David Geffen School of Medicine at UCLA, Los Angeles, USA
1 shared publication - Alberto Spinazzi
Worldwide Medical & Regulatory Affairs, Bracco Diagnostics Inc., Princeton, NJ, USA
1 shared publication - Ali Adibi
Department of Industrial, Systems, and Manufacturing Engineering, Wichita State University, Wichita, Kansas 67260
1 shared publication - Angelo Vanzulli
Department of Radiology, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162 Milan, Italy
1 shared publication - Arash Bedayat
Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles (UCLA), Los Angeles, California
1 shared publication
Latest Publications
- 1 March 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 306 (3) , e222551
Sarcopenia at CT and Poor Outcomes after Liver Transplant
- 1 March 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 306 (3) , e222551
Sarcopenia at CT and Poor Outcomes after Liver Transplant
- 1 July 2020
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 58 (4) , 781-796
Recent Innovations in Renal Vascular Imaging
- 1 July 2020
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 58 (4) , 781-796
Recent Innovations in Renal Vascular Imaging
- 20 June 2015
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 31 (7) , 1423-1424
Cardiac MRI diagnosis of coronary sinus to right atrium fistula in young asymptomatic patient
- 20 June 2015
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 31 (7) , 1423-1424
Cardiac MRI diagnosis of coronary sinus to right atrium fistula in young asymptomatic patient
- 8 May 2014
- Published by Springer Nature in European Radiology
- Vol. 24 (7) , 1586-1593
Computed tomography angiography of lower extremities in the emergency room for evaluation of patients with gunshot wounds
To assess the role of CT angiography in the evaluation of patients with lower extremity gunshot wounds in the emergency room. Eighty patients (73 male, 7 female, mean age 26 years) underwent CT angiography for the evaluation of lower extremity gunshot injuries. Imaging was conducted on the basis of standardized protocols utilizing 16-slice and 64-slice multidetector systems and images were qualitatively graded and assessed for various forms of arterial injury. CT angiography findings indicative of arterial injury were observed in 24 patients (30 %) and a total of 43 arterial injuries were noted; the most common form was focal narrowing/spasm (n = 16, 37.2 %); the most common artery involved was the superficial femoral artery (n = 12, 50 %). In qualitative assessment of images based on a 4-point grading system, both readers considered CT angiography diagnostically excellent (grade 4) in most cases. Surgical findings were consistent with CT angiography and follow-up of patients’ medical records showed no arterial injuries in patients with normal findings on initial imaging. Our findings demonstrate that CT angiography is an effective imaging modality for evaluation of lower extremity gunshot wounds and could help limit more invasive procedures such as catheter angiography to a select group of patients. • CT angiography efficiently evaluates lower extremity gunshot wounds. • CT angiography provides image quality sufficiently reliable for assessment of gunshot injuries. • CT angiography could help limit invasive procedures to select patients.
- 8 May 2014
- Published by Springer Nature in European Radiology
- Vol. 24 (7) , 1586-1593
Computed tomography angiography of lower extremities in the emergency room for evaluation of patients with gunshot wounds
To assess the role of CT angiography in the evaluation of patients with lower extremity gunshot wounds in the emergency room. Eighty patients (73 male, 7 female, mean age 26 years) underwent CT angiography for the evaluation of lower extremity gunshot injuries. Imaging was conducted on the basis of standardized protocols utilizing 16-slice and 64-slice multidetector systems and images were qualitatively graded and assessed for various forms of arterial injury. CT angiography findings indicative of arterial injury were observed in 24 patients (30 %) and a total of 43 arterial injuries were noted; the most common form was focal narrowing/spasm (n = 16, 37.2 %); the most common artery involved was the superficial femoral artery (n = 12, 50 %). In qualitative assessment of images based on a 4-point grading system, both readers considered CT angiography diagnostically excellent (grade 4) in most cases. Surgical findings were consistent with CT angiography and follow-up of patients’ medical records showed no arterial injuries in patients with normal findings on initial imaging. Our findings demonstrate that CT angiography is an effective imaging modality for evaluation of lower extremity gunshot wounds and could help limit more invasive procedures such as catheter angiography to a select group of patients. • CT angiography efficiently evaluates lower extremity gunshot wounds. • CT angiography provides image quality sufficiently reliable for assessment of gunshot injuries. • CT angiography could help limit invasive procedures to select patients.
- 1 June 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 192 (6) , 1731-1738
Time-Resolved MR Angiography in the Evaluation of Central Thoracic Venous Occlusive Disease
OBJECTIVE. The objective of our study was to assess the feasibility and diagnostic performance of time-resolved MR angiography (MRA) in the evaluation of central thoracic venous occlusive disease and to compare time-resolved MRA with conventional MRA and catheter angiography. MATERIALS AND METHODS. Twenty patients (eight women and 12 men; age range, 19–74 years) with suspected central thoracic venous occlusive disease underwent time-resolved MRA using time-resolved angiography with interleaved stochastic trajectories (TWIST) and parallel acquisition, followed by conventional MRA. Catheter angiography was performed within 1–14 days after MRA and was available for a total of 60 segments for correlation. Time-resolved and conventional MRA images were evaluated in separate reading sessions by two independent radiologists for image quality and level of confidence and degree of venoocclusive disease. The interobserver and intermodality agreement, sensitivity, and specificity were calculated using catheter angiography as the standard of reference. RESULTS. Time-resolved MRA resulted in diagnostic-quality images that did not differ significantly in quality compared with conventional MRA. Thirty-one segmental venous stenoses were identified. The kappa coefficient revealed moderate intermodality agreement (κ = 0.54; 95% CI, 0.32–0.76) between time-resolved MRA and conventional MRA. When compared with catheter angiography, the sensitivity and specificity for the diagnosis of significant stenosis (≥ 70%) were 87.5% and 68% for time-resolved MRA and 90% and 90% for conventional MRA, respectively. CONCLUSION. Time-resolved MRA, as described in this study, has the potential to be used as an initial and screening diagnostic tool obviating conventional MRA and its associated higher contrast dose in normal and near-normal examinations. However, because of its relatively lower specificity, adjunct use of conventional MRA is still required for accurate grading of venous occlusive disease.
- 1 June 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 192 (6) , 1731-1738
Time-Resolved MR Angiography in the Evaluation of Central Thoracic Venous Occlusive Disease
OBJECTIVE. The objective of our study was to assess the feasibility and diagnostic performance of time-resolved MR angiography (MRA) in the evaluation of central thoracic venous occlusive disease and to compare time-resolved MRA with conventional MRA and catheter angiography. MATERIALS AND METHODS. Twenty patients (eight women and 12 men; age range, 19–74 years) with suspected central thoracic venous occlusive disease underwent time-resolved MRA using time-resolved angiography with interleaved stochastic trajectories (TWIST) and parallel acquisition, followed by conventional MRA. Catheter angiography was performed within 1–14 days after MRA and was available for a total of 60 segments for correlation. Time-resolved and conventional MRA images were evaluated in separate reading sessions by two independent radiologists for image quality and level of confidence and degree of venoocclusive disease. The interobserver and intermodality agreement, sensitivity, and specificity were calculated using catheter angiography as the standard of reference. RESULTS. Time-resolved MRA resulted in diagnostic-quality images that did not differ significantly in quality compared with conventional MRA. Thirty-one segmental venous stenoses were identified. The kappa coefficient revealed moderate intermodality agreement (κ = 0.54; 95% CI, 0.32–0.76) between time-resolved MRA and conventional MRA. When compared with catheter angiography, the sensitivity and specificity for the diagnosis of significant stenosis (≥ 70%) were 87.5% and 68% for time-resolved MRA and 90% and 90% for conventional MRA, respectively. CONCLUSION. Time-resolved MRA, as described in this study, has the potential to be used as an initial and screening diagnostic tool obviating conventional MRA and its associated higher contrast dose in normal and near-normal examinations. However, because of its relatively lower specificity, adjunct use of conventional MRA is still required for accurate grading of venous occlusive disease.
- 1 February 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 234 (2) , 399-408
Contrast-enhanced MR Angiography of the Renal Arteries: Blinded Multicenter Crossover Comparison of Gadobenate Dimeglumine and Gadopentetate Dimeglumine
To prospectively and intraindividually compare 0.1 mmol/kg gadobenate dimeglumine with 0.2 mmol/kg gadopentetate dimeglumine for contrast material-enhanced magnetic resonance (MR) angiography of the renal arteries. Institutional review board approval was granted by each of three participating centers. The study accorded with international standards for good clinical practice and Declaration of Helsinki and subsequent amendments. Patients gave written informed consent before enrollment. Patients (n = 34) underwent two MR angiographic examinations more than 48 hours but less than 12 days apart. Gadobenate dimeglumine followed by gadopentetate dimeglumine was administered in 18 patients; the order of administration was reversed in 16 patients. A 1.5-T MR imager was used with a phase-encoded three-dimensional spoiled breath-hold pulse sequence. Two blinded independent readers qualitatively assessed randomized subtracted maximum intensity projection images. A three-point scale for diagnostic quality (0, poor; 1a or 1p, moderate; and 2a or 2p, adequate [a and p refer, respectively, to absence and presence of vascular lesions]) was used to score each of nine segments of the abdominal aorta and both renal arteries (possible overall score, 18). Quantitative assessment (vessel signal-to-noise ratio [SNR], vessel-muscle contrast-to-noise ratio [CNR]) of source images was performed for regions of interest in supra-, juxta-, and infrarenal aorta segments and psoas muscle. Data were tested with analysis of variance for two-period crossover design. Interreader agreement was evaluated with Cohen kappa statistics. No difference in mean image quality between the two contrast agents was observed; scores for gadobenate dimeglumine and gadopentetate dimeglumine were 15.15 and 15.23 for reader 1 and 16.77 and 17.01 for reader 2. The order of contrast material administration likewise produced no quality differences: readers 1 and 2 reported scores of 14.4 +/- 4.2 (standard deviation) and 16.7 +/- 2.3, respectively, when gadobenate dimeglumine was given first, and 15.2 +/- 1.8 and 16.6 +/- 1.6, respectively, when gadopentetate dimeglumine was given first. Results of quantitative evaluation showed increasing SNR and CNR with gadobenate dimeglumine in segments at progressively lower levels of the aorta, but increases in SNR and CNR at the infrarenal aorta (48.3 vs 40.6 and 44.2 vs 36.4, respectively) were not significant (P = .05 for both). Gadobenate dimeglumine at a dose of 0.1 mmol/kg is comparable to gadopentetate dimeglumine at 0.2 mmol/kg for contrast-enhanced renal MR angiography.
- 1 February 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 234 (2) , 399-408
Contrast-enhanced MR Angiography of the Renal Arteries: Blinded Multicenter Crossover Comparison of Gadobenate Dimeglumine and Gadopentetate Dimeglumine
To prospectively and intraindividually compare 0.1 mmol/kg gadobenate dimeglumine with 0.2 mmol/kg gadopentetate dimeglumine for contrast material-enhanced magnetic resonance (MR) angiography of the renal arteries. Institutional review board approval was granted by each of three participating centers. The study accorded with international standards for good clinical practice and Declaration of Helsinki and subsequent amendments. Patients gave written informed consent before enrollment. Patients (n = 34) underwent two MR angiographic examinations more than 48 hours but less than 12 days apart. Gadobenate dimeglumine followed by gadopentetate dimeglumine was administered in 18 patients; the order of administration was reversed in 16 patients. A 1.5-T MR imager was used with a phase-encoded three-dimensional spoiled breath-hold pulse sequence. Two blinded independent readers qualitatively assessed randomized subtracted maximum intensity projection images. A three-point scale for diagnostic quality (0, poor; 1a or 1p, moderate; and 2a or 2p, adequate [a and p refer, respectively, to absence and presence of vascular lesions]) was used to score each of nine segments of the abdominal aorta and both renal arteries (possible overall score, 18). Quantitative assessment (vessel signal-to-noise ratio [SNR], vessel-muscle contrast-to-noise ratio [CNR]) of source images was performed for regions of interest in supra-, juxta-, and infrarenal aorta segments and psoas muscle. Data were tested with analysis of variance for two-period crossover design. Interreader agreement was evaluated with Cohen kappa statistics. No difference in mean image quality between the two contrast agents was observed; scores for gadobenate dimeglumine and gadopentetate dimeglumine were 15.15 and 15.23 for reader 1 and 16.77 and 17.01 for reader 2. The order of contrast material administration likewise produced no quality differences: readers 1 and 2 reported scores of 14.4 +/- 4.2 (standard deviation) and 16.7 +/- 2.3, respectively, when gadobenate dimeglumine was given first, and 15.2 +/- 1.8 and 16.6 +/- 1.6, respectively, when gadopentetate dimeglumine was given first. Results of quantitative evaluation showed increasing SNR and CNR with gadobenate dimeglumine in segments at progressively lower levels of the aorta, but increases in SNR and CNR at the infrarenal aorta (48.3 vs 40.6 and 44.2 vs 36.4, respectively) were not significant (P = .05 for both). Gadobenate dimeglumine at a dose of 0.1 mmol/kg is comparable to gadopentetate dimeglumine at 0.2 mmol/kg for contrast-enhanced renal MR angiography.
- 1 December 2004
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 20 (6) , 587-591
Whole Body MR Angiography Screening
- 1 December 2004
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 20 (6) , 587-591
Whole Body MR Angiography Screening
- Open Access
- 29 March 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (4) , 453-458
Real‐time high‐resolution MRI for the assessment of gastric motility: Pre‐ and postpharmacological stimuli
Purpose To determine the practicality of MRI using a new real-time sequence for the assessment of gastric motion, and quantify the effects of motility-modifying substances. Materials and Methods Six healthy volunteers ingested 400 mL of a high-calorie liquid nutrient. Two-dimensional real-time TrueFISP sequences were acquired for up to 30 minutes following the ingestion. The acquisition plane was chosen parallel to the axis of the gastric antrum. The examination was performed on three separate days with and without i.v. administration of 10 mg metoclopramide or 20 mg scopolamine. A motility index was calculated for each real-time data set. Results Delineation of the gastric lumen proved easy and robust. The intravenous application of motility-modifying agents resulted in significant changes in the motility index. The administration of metoclopramide resulted in an average increase of the index by a factor of 1.5, whereas the application of scopolamine led to a decrease of the index by a factor of 3.0. Conclusion TrueFISP MRI performed well in depicting the gastric lumen and assessing gastric motility. Furthermore, we were able to evaluate and quantify the effect of motility-modifying agents. The noninvasive nature of MRI makes this imaging modality an attractive alternative to conventional invasive diagnostic tools for gastric motility disorders and monitoring of therapy. J. Magn. Reson. Imaging 2004;19:453–458.
- 29 March 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (4) , 453-458
Open AccessReal‐time high‐resolution MRI for the assessment of gastric motility: Pre‐ and postpharmacological stimuli
Purpose To determine the practicality of MRI using a new real-time sequence for the assessment of gastric motion, and quantify the effects of motility-modifying substances. Materials and Methods Six healthy volunteers ingested 400 mL of a high-calorie liquid nutrient. Two-dimensional real-time TrueFISP sequences were acquired for up to 30 minutes following the ingestion. The acquisition plane was chosen parallel to the axis of the gastric antrum. The examination was performed on three separate days with and without i.v. administration of 10 mg metoclopramide or 20 mg scopolamine. A motility index was calculated for each real-time data set. Results Delineation of the gastric lumen proved easy and robust. The intravenous application of motility-modifying agents resulted in significant changes in the motility index. The administration of metoclopramide resulted in an average increase of the index by a factor of 1.5, whereas the application of scopolamine led to a decrease of the index by a factor of 3.0. Conclusion TrueFISP MRI performed well in depicting the gastric lumen and assessing gastric motility. Furthermore, we were able to evaluate and quantify the effect of motility-modifying agents. The noninvasive nature of MRI makes this imaging modality an attractive alternative to conventional invasive diagnostic tools for gastric motility disorders and monitoring of therapy. J. Magn. Reson. Imaging 2004;19:453–458.
- 1 August 2002
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 179 (2) , 445-449
Three-Dimensional Volumetric Interpolated Breath-Hold MR Imaging for Whole-Body Tumor Staging in Less Than 15 Minutes: A Feasibility Study
OBJECTIVE. The purpose of our study was to evaluate the feasibility and accuracy of three-dimensional (3D) volumetric interpolated breath-hold whole-body MR imaging using CT and nuclear medicine techniques as the standard of reference in patients with metastases. CONCLUSION. The 3D volumetric interpolated breath-hold whole-body MR imaging examination for metastases screening correlates well with CT and scintigraphy. The use of the rolling table platform permits rapid whole-body imaging in an average of 11 min. The preliminary results indicate that the described technique has the potential to emerge as an all-encompassing alternative to conventional multimodality tumor staging strategies.
- 1 August 2002
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 179 (2) , 445-449
Three-Dimensional Volumetric Interpolated Breath-Hold MR Imaging for Whole-Body Tumor Staging in Less Than 15 Minutes: A Feasibility Study
OBJECTIVE. The purpose of our study was to evaluate the feasibility and accuracy of three-dimensional (3D) volumetric interpolated breath-hold whole-body MR imaging using CT and nuclear medicine techniques as the standard of reference in patients with metastases. CONCLUSION. The 3D volumetric interpolated breath-hold whole-body MR imaging examination for metastases screening correlates well with CT and scintigraphy. The use of the rolling table platform permits rapid whole-body imaging in an average of 11 min. The preliminary results indicate that the described technique has the potential to emerge as an all-encompassing alternative to conventional multimodality tumor staging strategies.