Klára Tóth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Klára Tóth has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Ferenc Gaál
Department of Chemistry, Faculty of Sciences, Trg D. Obradovića 3, 21000 Novi Sad, Republic of Serbia
3 shared publicationsLuka Bjelica
Department of Chemistry, Faculty of Sciences, Trg D. Obradovića 3, 21000 Novi Sad, Republic of Serbia
3 shared publicationsMihály Kádár
Research Group for Technical Analytical Chemistry of the Hungarian Academy of Sciences, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1111 Budapest, Szent Gellért tér 4, Hungary
3 shared publicationsValéria Guzsvány
Department of Chemistry, Faculty of Sciences, Trg D. Obradovića 3, 21000 Novi Sad, Republic of Serbia
3 shared publications- Alajos Grün
Department of Organic Chemistry and Technology, Budapest University of Technology and Economics, Budapest, Hungary
2 shared publications Róbert Bereczki
Technical Analytical Research Group of the Hungarian Academy of Sciences, Department of General and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, H-1111 Budapest, Hungary
2 shared publications
Latest Publications
- 10 September 2009
- Published by Wiley in Electroanalysis
- Vol. 21 (17-18) , 1961-1969
Calixarene/Nafion‐Modified Bismuth‐Film Electrodes for Adsorptive Stripping Voltammetric Determination of Lead
- 10 September 2009
- Published by Wiley in Electroanalysis
- Vol. 21 (17-18) , 1961-1969
Calixarene/Nafion‐Modified Bismuth‐Film Electrodes for Adsorptive Stripping Voltammetric Determination of Lead
- 29 January 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (3) , 291-300
Monitoring of Photocatalytic Degradation of Selected Neonicotinoid Insecticides by Cathodic Voltammetry with a Bismuth Film Electrode
An electroanalytical method has been developed for the determination of two water soluble pyridine based neonicotinoid insecticides (imidacloprid and acetamiprid) by differential pulse voltammetry with a bismuth film electrode in aqueous Britton–Robinson buffer solution as supporting electrolyte. The bismuth film electrode preparation was optimized for cathodic voltammetric application. The reduction peaks of the neonicotionids appeared at potentials more negative than −0.5 V (BiFE vs. Ag/AgCl/3.0 M KCl) and the signal characteristics depended on the pH of the supporting electrolyte. The best analysis conditions were found to be pH 8.0 for imidacloprid and pH 3.0 for acetamiprid at the following measurement parameters: pulse amplitude 50 mV, pulse width 50 ms and scan rate 25 mV. Calibration curves were linear in the concentration range of 2.43–51.1 μg/cm3 for imidacloprid and 2.95–47.3 μg/cm3 for acetamiprid, while the detection limits were 0.73 μg/cm3 and 0.88 μg/cm3 for imidacloprid and acetamiprid, respectively. The electroanalytical method has allowed monitoring the heterogeneous photocatalytic (O2/TiO2/UV) degradation of the two insecticides via their disappearance. The dynamics and the reaction rate determined on the basis of the electrochemical data were validated with HPLC/DAD and FTIR measurements.
- 29 January 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (3) , 291-300
Monitoring of Photocatalytic Degradation of Selected Neonicotinoid Insecticides by Cathodic Voltammetry with a Bismuth Film Electrode
An electroanalytical method has been developed for the determination of two water soluble pyridine based neonicotinoid insecticides (imidacloprid and acetamiprid) by differential pulse voltammetry with a bismuth film electrode in aqueous Britton–Robinson buffer solution as supporting electrolyte. The bismuth film electrode preparation was optimized for cathodic voltammetric application. The reduction peaks of the neonicotionids appeared at potentials more negative than −0.5 V (BiFE vs. Ag/AgCl/3.0 M KCl) and the signal characteristics depended on the pH of the supporting electrolyte. The best analysis conditions were found to be pH 8.0 for imidacloprid and pH 3.0 for acetamiprid at the following measurement parameters: pulse amplitude 50 mV, pulse width 50 ms and scan rate 25 mV. Calibration curves were linear in the concentration range of 2.43–51.1 μg/cm3 for imidacloprid and 2.95–47.3 μg/cm3 for acetamiprid, while the detection limits were 0.73 μg/cm3 and 0.88 μg/cm3 for imidacloprid and acetamiprid, respectively. The electroanalytical method has allowed monitoring the heterogeneous photocatalytic (O2/TiO2/UV) degradation of the two insecticides via their disappearance. The dynamics and the reaction rate determined on the basis of the electrochemical data were validated with HPLC/DAD and FTIR measurements.
- 17 July 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (13-14) , 1363-1371
Bismuth Film Electrode for the Cathodic Electrochemical Determination of Thiamethoxam
A cathodic electrochemical application of bismuth film modified glassy carbon electrode was investigated with the objective of determining thiamethoxam insecticide. The conditions of bismuth film deposition (electrode pretreatment procedure, composition of the plating solution, plating potential and film stability) were optimized using electrochemical and microscopic techniques. It was found that the bismuth film generation on glassy carbon substrate in a plating solution of 0.02 M Bi(NO3)3, 1 M HCl and 0.5 M KBr, at −0.25 V (vs. Ag/AgCl/3 M KCl) for 60 s and subsequent electrochemical conditioning yielded a modified electrode suitable for analytical purposes. Thiamethoxam was determined by differential pulse voltammetry in Britton–Robinson buffer of pH 8.0 in the concentration range of 1.26–45.0 μg/cm3. The reproducibility of the analytical signal was characterized by a relative standard deviation smaller than 1.5%, and the calculated values of detection and quantitation limits were 0.38 μg/cm3 and 1.26 μg/cm3, respectively. The applicability of the modified electrode was tested on real, agriculturally‐incurred potato and maize samples.
- 17 July 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (13-14) , 1363-1371
Bismuth Film Electrode for the Cathodic Electrochemical Determination of Thiamethoxam
A cathodic electrochemical application of bismuth film modified glassy carbon electrode was investigated with the objective of determining thiamethoxam insecticide. The conditions of bismuth film deposition (electrode pretreatment procedure, composition of the plating solution, plating potential and film stability) were optimized using electrochemical and microscopic techniques. It was found that the bismuth film generation on glassy carbon substrate in a plating solution of 0.02 M Bi(NO3)3, 1 M HCl and 0.5 M KBr, at −0.25 V (vs. Ag/AgCl/3 M KCl) for 60 s and subsequent electrochemical conditioning yielded a modified electrode suitable for analytical purposes. Thiamethoxam was determined by differential pulse voltammetry in Britton–Robinson buffer of pH 8.0 in the concentration range of 1.26–45.0 μg/cm3. The reproducibility of the analytical signal was characterized by a relative standard deviation smaller than 1.5%, and the calculated values of detection and quantitation limits were 0.38 μg/cm3 and 1.26 μg/cm3, respectively. The applicability of the modified electrode was tested on real, agriculturally‐incurred potato and maize samples.
- 31 May 2006
- Published by Elsevier in Analytica Chimica Acta
- Vol. 569 (1-2) , 42-49
Crown bridged thiacalix[4]arenes as cesium-selective ionophores in solvent polymeric membrane electrodes
- 31 May 2006
- Published by Elsevier in Analytica Chimica Acta
- Vol. 569 (1-2) , 42-49
Crown bridged thiacalix[4]arenes as cesium-selective ionophores in solvent polymeric membrane electrodes
- 30 March 2006
- Published by Springer Nature in Microchimica Acta
- Vol. 154 (3-4) , 321-328
Rapid Differential Pulse Polarographic Determination of Thiamethoxam in Commercial Formulations and some Real Samples
- 30 March 2006
- Published by Springer Nature in Microchimica Acta
- Vol. 154 (3-4) , 321-328
Rapid Differential Pulse Polarographic Determination of Thiamethoxam in Commercial Formulations and some Real Samples
- 26 November 2004
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 130 (1) , 63-70
Synthesis and characterization of covalently immobilized bis-crown ether based potassium ionophore
The synthesis of a novel covalently immobilized crown ether based potassium ionophore is presented. Apart from previously proposed methods for the preparation of PVC linked ionophores based on the chemical modification of functionalized PVC polymers, the hereby proposed procedure involves the direct copolymerization of a suitable derivative of the bis-crown ether type potassium ionophore (BME 44) and vinyl chloride monomer. The analytical performance of the potentiometric ion selective electrodes incorporating the PVC bound ionophore were optimized and determined. Compared with electrodes based on other bis-crown ether type immobilized potassium selective ionophores a slightly improved logKpot K,Na and a longer lifetime was found. Spectral imaging and chronoamperometry were used to study the mobility of different bis-crown ether derivatives in plasticized PVC membranes.
- 26 November 2004
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 130 (1) , 63-70
Synthesis and characterization of covalently immobilized bis-crown ether based potassium ionophore
The synthesis of a novel covalently immobilized crown ether based potassium ionophore is presented. Apart from previously proposed methods for the preparation of PVC linked ionophores based on the chemical modification of functionalized PVC polymers, the hereby proposed procedure involves the direct copolymerization of a suitable derivative of the bis-crown ether type potassium ionophore (BME 44) and vinyl chloride monomer. The analytical performance of the potentiometric ion selective electrodes incorporating the PVC bound ionophore were optimized and determined. Compared with electrodes based on other bis-crown ether type immobilized potassium selective ionophores a slightly improved logKpot K,Na and a longer lifetime was found. Spectral imaging and chronoamperometry were used to study the mobility of different bis-crown ether derivatives in plasticized PVC membranes.