Tomoyuki Inoue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tomoyuki Inoue has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Yuichi Hori
4 shared publicationsFumihiko Takamatsu
3 shared publicationsNaoyuki Maeda
From the Department of Ophthalmology, Osaka University Medical School, Suita, Japan
3 shared publications- Naoyuki Maeda
Department of Ophthalmology (S.G., K.M.), The University of Osaka Graduate School of Medicine, Suita, Osaka, Japan
3 shared publications Michiko Kandori
2 shared publicationsRyoichiro Kageyama
Department of Cell Biology, Institute for Virus Research, Kyoto University, Kawaracho, Kyoto, Japan
2 shared publications
Latest Publications
- 1 June 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (6) , 839-841
Spontaneous Bleb Formation in a Presumed Pellucid Marginal Corneal Degeneration With Acute Hydrops
To report a case of spontaneous bleb formation in a presumed pellucid marginal corneal degeneration with acute hydrops. A 51-year-old man reported sudden ocular pain with a lower conjunctival mass in his left eye. A clinical examination was performed to investigate this lesion. The intraocular pressure in the left eye was markedly lower compared with that in the opposite eye. Slit-lamp examination of the left eye showed a conjunctival mass inferior to the corneoscleral limbus adjacent to corneal epithelial and stromal edema without perforation. Corneal topography showed the typical bow tie appearance of corneal steepening rotated 120 degrees clockwise. The right eye was totally normal. Fourier-domain optical coherence tomography with a corneal anterior module adaptor clearly showed a break in Descemet membrane and a ruptured corneal stromal cleft under the conjunctiva near the corneal limbus that resulted in spontaneous bleb formation. The cornea gradually healed after bandage treatment; the spontaneous bleb became smaller and the corneal stromal cleft and edema regressed at 3 months with corneal scarring. The intraocular pressure in the left eye recovered to the same level as that in the opposite eye in association with the decreased bleb size. This case indicated that spontaneous bleb formation in a pellucid marginal corneal degeneration should be included in the differential diagnosis of a conjunctival mass of unknown origin.
- 1 June 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (6) , 839-841
Spontaneous Bleb Formation in a Presumed Pellucid Marginal Corneal Degeneration With Acute Hydrops
To report a case of spontaneous bleb formation in a presumed pellucid marginal corneal degeneration with acute hydrops. A 51-year-old man reported sudden ocular pain with a lower conjunctival mass in his left eye. A clinical examination was performed to investigate this lesion. The intraocular pressure in the left eye was markedly lower compared with that in the opposite eye. Slit-lamp examination of the left eye showed a conjunctival mass inferior to the corneoscleral limbus adjacent to corneal epithelial and stromal edema without perforation. Corneal topography showed the typical bow tie appearance of corneal steepening rotated 120 degrees clockwise. The right eye was totally normal. Fourier-domain optical coherence tomography with a corneal anterior module adaptor clearly showed a break in Descemet membrane and a ruptured corneal stromal cleft under the conjunctiva near the corneal limbus that resulted in spontaneous bleb formation. The cornea gradually healed after bandage treatment; the spontaneous bleb became smaller and the corneal stromal cleft and edema regressed at 3 months with corneal scarring. The intraocular pressure in the left eye recovered to the same level as that in the opposite eye in association with the decreased bleb size. This case indicated that spontaneous bleb formation in a pellucid marginal corneal degeneration should be included in the differential diagnosis of a conjunctival mass of unknown origin.
- 1 December 2011
- Published by American Medical Association (AMA) in JAMA Ophthalmology
- Vol. 129 (12) , 1629-1630
Human Herpesvirus 8 in Corneal Endotheliitis Resulting in Graft Failure After Penetrating Keratoplasty Refractory to Allograft Rejection Therapy
- 1 December 2011
- Published by American Medical Association (AMA) in JAMA Ophthalmology
- Vol. 129 (12) , 1629-1630
Human Herpesvirus 8 in Corneal Endotheliitis Resulting in Graft Failure After Penetrating Keratoplasty Refractory to Allograft Rejection Therapy
- 1 April 2011
- Vol. 115 (4) , 368-73
[Comparing anterior segment shape of keratoconic eyes and normal eyes by anterior segment optical coherence tomography].
To compare the shape of the anterior segment of eyes with keratoconus and normal controls using anterior segment optical coherence tomography (AS-OCT). Included in the study were eyes with keratoconus (60 eyes of 40 patients), eyes with suspected keratoconus (10 eyes of 10 patients), and normal controls (21 eyes of 13 persons). Anterior segment imaging was performed in these eyes with AS-OCT, and the distance for angle to angle, anterior chamber depth and distribution of corneal thickness including the increasing ratio from center to periphery were compared. There was no significant difference in the distance of angle to angle among the three groups. The ratio of eyes with anterior chamber depth of more than 3.6 mm in the eyes with keratoconus was significantly higher than in the normal group. Although the corneal thickness from the center to the 3 mm periphery in the keratoconus group and in the keratoconus suspect group was significantly thinner than those in the normal group, there were no significant differences in the corneal thickness at the 4 mm superior or temporal areas among the three groups. Increasing ratio of the corneal thickness from the center to the periphery showed the higher value in the keratoconus group than in the others. AS-OCT enabled us to understand the configuration of the anterior segment of the eye and the distribution of the corneal thickness quantitatively even for the advanced keratoconus cases with corneal scar. AS-OCT may be useful as an aid to contact lens prescription and surgical planning.
- 1 April 2011
- Vol. 115 (4) , 368-73
[Comparing anterior segment shape of keratoconic eyes and normal eyes by anterior segment optical coherence tomography].
To compare the shape of the anterior segment of eyes with keratoconus and normal controls using anterior segment optical coherence tomography (AS-OCT). Included in the study were eyes with keratoconus (60 eyes of 40 patients), eyes with suspected keratoconus (10 eyes of 10 patients), and normal controls (21 eyes of 13 persons). Anterior segment imaging was performed in these eyes with AS-OCT, and the distance for angle to angle, anterior chamber depth and distribution of corneal thickness including the increasing ratio from center to periphery were compared. There was no significant difference in the distance of angle to angle among the three groups. The ratio of eyes with anterior chamber depth of more than 3.6 mm in the eyes with keratoconus was significantly higher than in the normal group. Although the corneal thickness from the center to the 3 mm periphery in the keratoconus group and in the keratoconus suspect group was significantly thinner than those in the normal group, there were no significant differences in the corneal thickness at the 4 mm superior or temporal areas among the three groups. Increasing ratio of the corneal thickness from the center to the periphery showed the higher value in the keratoconus group than in the others. AS-OCT enabled us to understand the configuration of the anterior segment of the eye and the distribution of the corneal thickness quantitatively even for the advanced keratoconus cases with corneal scar. AS-OCT may be useful as an aid to contact lens prescription and surgical planning.
- 1 August 2010
- Published by Wolters Kluwer Health in Cornea
- Vol. 29 (8) , 917-920
A Chandelier-Illuminated Anterior Chamber Maintainer for Use During Descemet Stripping Automated Endothelial Keratoplasty in Patients With Advanced Bullous Keratopathy
A new 25-gauge illuminated anterior chamber maintainer composed of a 25-gauge infusion cannula through which a 29-gauge chandelier fiber probe passes was developed for use during Descemet stripping automated endothelial keratoplasty to treat patients with advanced bullous keratopathy. This device, which is compatible with a xenon or mercury vapor illuminator to generate powerful wide-angle illumination from the cone-shaped chandelier fiber tip, is self-retained at the corneal limbus after insertion of the infusion cannula through a corneal side port. Because of its bifunctionality, that is, bright illumination and adequate irrigation flow, excellent visibility with stable anterior chamber maintenance can be concurrently obtained for Descemet stripping, endothelial graft insertion, and subsequent intraocular manipulations without the need for use of a biologic staining technique or ophthalmic viscosurgical products even in patients with severe corneal haze. This new device facilitates safe and simple intraocular manipulation during Descemet stripping automated endothelial keratoplasty.
- 1 August 2010
- Published by Wolters Kluwer Health in Cornea
- Vol. 29 (8) , 917-920
A Chandelier-Illuminated Anterior Chamber Maintainer for Use During Descemet Stripping Automated Endothelial Keratoplasty in Patients With Advanced Bullous Keratopathy
A new 25-gauge illuminated anterior chamber maintainer composed of a 25-gauge infusion cannula through which a 29-gauge chandelier fiber probe passes was developed for use during Descemet stripping automated endothelial keratoplasty to treat patients with advanced bullous keratopathy. This device, which is compatible with a xenon or mercury vapor illuminator to generate powerful wide-angle illumination from the cone-shaped chandelier fiber tip, is self-retained at the corneal limbus after insertion of the infusion cannula through a corneal side port. Because of its bifunctionality, that is, bright illumination and adequate irrigation flow, excellent visibility with stable anterior chamber maintenance can be concurrently obtained for Descemet stripping, endothelial graft insertion, and subsequent intraocular manipulations without the need for use of a biologic staining technique or ophthalmic viscosurgical products even in patients with severe corneal haze. This new device facilitates safe and simple intraocular manipulation during Descemet stripping automated endothelial keratoplasty.
- Open Access
- 1 April 2010
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 128 (4) , 502-503
Corneal Endotheliitis With Quantitative Polymerase Chain Reaction Positive for Human Herpesvirus 7
Human herpesvirus 7 (HHV-7), a common virus of the subfamily of β-herpesviruses like cytomegalovirus (CMV) and HHV-6,1 was isolated initially from peripheral blood cells in adults.2 It causes ubiquitous infection in children3 as well as exanthema subitum.4 However, HHV-7–related ocular manifestations have not been reported. We describe a patient with unilateral corneal endotheliitis with aqueous humor positive for HHV-7 DNA by real-time polymerase chain reaction (PCR).
- 1 April 2010
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 128 (4) , 502-503
Open AccessCorneal Endotheliitis With Quantitative Polymerase Chain Reaction Positive for Human Herpesvirus 7
Human herpesvirus 7 (HHV-7), a common virus of the subfamily of β-herpesviruses like cytomegalovirus (CMV) and HHV-6,1 was isolated initially from peripheral blood cells in adults.2 It causes ubiquitous infection in children3 as well as exanthema subitum.4 However, HHV-7–related ocular manifestations have not been reported. We describe a patient with unilateral corneal endotheliitis with aqueous humor positive for HHV-7 DNA by real-time polymerase chain reaction (PCR).
- Open Access
- 11 December 2009
- Published by Oxford University Press (OUP) in Stem Cells
- Vol. 28 (3) , 489-500
Maximizing Functional Photoreceptor Differentiation From Adult Human Retinal Stem Cells
Retinal stem cells (RSCs) are present in the ciliary margin of the adult human eye and can give rise to all retinal cell types. Here we show that modulation of retinal transcription factor gene expression in human RSCs greatly enriches photoreceptor progeny, and that strong enrichment was obtained with the combined transduction of OTX2 and CRX together with the modulation of CHX10. When these genetically modified human RSC progeny are transplanted into mouse eyes, their retinal integration and differentiation is superior to unmodified RSC progeny. Moreover, electrophysiologic and behavioral tests show that these transplanted cells promote functional recovery in transducin mutant mice. This study suggests that gene modulation in human RSCs may provide a source of photoreceptor cells for the treatment of photoreceptor disease.
- 11 December 2009
- Published by Oxford University Press (OUP) in Stem Cells
- Vol. 28 (3) , 489-500
Open AccessMaximizing Functional Photoreceptor Differentiation From Adult Human Retinal Stem Cells
Retinal stem cells (RSCs) are present in the ciliary margin of the adult human eye and can give rise to all retinal cell types. Here we show that modulation of retinal transcription factor gene expression in human RSCs greatly enriches photoreceptor progeny, and that strong enrichment was obtained with the combined transduction of OTX2 and CRX together with the modulation of CHX10. When these genetically modified human RSC progeny are transplanted into mouse eyes, their retinal integration and differentiation is superior to unmodified RSC progeny. Moreover, electrophysiologic and behavioral tests show that these transplanted cells promote functional recovery in transducin mutant mice. This study suggests that gene modulation in human RSCs may provide a source of photoreceptor cells for the treatment of photoreceptor disease.
- 1 September 2009
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 53 (5) , 548-549
Two cases of varicella zoster virus keratitis with atypical extensive pseudodendrites
- 1 September 2009
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 53 (5) , 548-549
Two cases of varicella zoster virus keratitis with atypical extensive pseudodendrites
- 1 February 2002
- Vol. 129 (4) , 831-42
Math3 and NeuroD regulate amacrine cell fate specification in the retina.
The basic helix-loop-helix genes Math3 and NeuroD are expressed by differentiating amacrine cells, retinal interneurons. Previous studies have demonstrated that a normal number of amacrine cells is generated in mice lacking either Math3 or NEUROD: We have found that, in Math3-NeuroD double-mutant retina, amacrine cells are completely missing, while ganglion and Müller glial cells are increased in number. In the double-mutant retina, the cells that would normally differentiate into amacrine cells did not die but adopted the ganglion and glial cell fates. Misexpression studies using the developing retinal explant cultures showed that, although Math3 and NeuroD alone only promoted rod genesis, they significantly increased the population of amacrine cells when the homeobox gene Pax6 or Six3 was co-expressed. These results indicate that Math3 and NeuroD are essential, but not sufficient, for amacrine cell genesis, and that co-expression of the basic helix-loop-helix and homeobox genes is required for specification of the correct neuronal subtype.
- 1 February 2002
- Vol. 129 (4) , 831-42
Math3 and NeuroD regulate amacrine cell fate specification in the retina.
The basic helix-loop-helix genes Math3 and NeuroD are expressed by differentiating amacrine cells, retinal interneurons. Previous studies have demonstrated that a normal number of amacrine cells is generated in mice lacking either Math3 or NEUROD: We have found that, in Math3-NeuroD double-mutant retina, amacrine cells are completely missing, while ganglion and Müller glial cells are increased in number. In the double-mutant retina, the cells that would normally differentiate into amacrine cells did not die but adopted the ganglion and glial cell fates. Misexpression studies using the developing retinal explant cultures showed that, although Math3 and NeuroD alone only promoted rod genesis, they significantly increased the population of amacrine cells when the homeobox gene Pax6 or Six3 was co-expressed. These results indicate that Math3 and NeuroD are essential, but not sufficient, for amacrine cell genesis, and that co-expression of the basic helix-loop-helix and homeobox genes is required for specification of the correct neuronal subtype.