Thomas Dittmar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Dittmar has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Eckhard Worch
Institute of Water Chemistry, Technische Universität Dresden, D-01062 Dresden, Germany
4 shared publicationsViktor Schmalz
Institute of Water Chemistry, Technische Universität Dresden, D-01062 Dresden, Germany
4 shared publicationsDaniela Haaken
TU Dresden, Institute of Water Chemistry, 01062 Dresden, Germany
3 shared publicationsE. Worch
Institut für Wasserchemie, Technische Universität Dresden, Zellescher Weg 40, D-01062 Dresden, Germany
2 shared publicationsV. Schmalz
Institut für Wasserchemie, Technische Universität Dresden, Zellescher Weg 40, D-01062 Dresden, Germany
2 shared publicationsD. Fischer
Technologiezentrum Wasser, Außenstelle Dresden, Wasserwerkstraße 2, D-01326 Dresden, Germany
1 shared publication
Latest Publications
- Open Access
- 23 October 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (11) , 2335
Portable Analyzer for On-Site Determination of Dissolved Organic Carbon—Development and Field Testing
Dissolved organic carbon (DOC) is a sum parameter that is frequently used in water analytics. Highly resolved and accurate DOC data are necessary, for instance, for water quality monitoring and for the evaluation of the efficiency of treatment processes. The conventional DOC determination methods consist of on-site sampling and subsequent analysis in a stationary device in a laboratory. However, especially in regions where no or only poorly equipped laboratories are available, this method bears the risk of getting erroneous results. For this reason, the objective of the present study was to set up a reliable and portable DOC analyzer for on-site analysis. The presented DOC system is equipped with an electrolysis-based decomposition cell with boron-doped diamond electrodes (BDD) that oxidizes the organic compounds to carbon dioxide. Within this study, the influence of different electrode materials and the composition of the applied electrolytes on the DOC decomposition in an undivided electrolytic cell were systematically investigated. Furthermore, some technical aspects of the portable prototype are discussed. After a detailed validation, the prototype was used in an ongoing monitoring program in Northern India. The limit of detection is 0.1 mg L−1 C with a relative standard deviation of 2.3% in a linear range up to 1000 mg L C−1. The key features of the portable DOC analyzer are: No need for ultra-pure gases, catalysts or burning technology, an analyzing time per sample below 5 min, and a reliable on-site DOC determination.
- 23 October 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (11) , 2335
Open AccessPortable Analyzer for On-Site Determination of Dissolved Organic Carbon—Development and Field Testing
Dissolved organic carbon (DOC) is a sum parameter that is frequently used in water analytics. Highly resolved and accurate DOC data are necessary, for instance, for water quality monitoring and for the evaluation of the efficiency of treatment processes. The conventional DOC determination methods consist of on-site sampling and subsequent analysis in a stationary device in a laboratory. However, especially in regions where no or only poorly equipped laboratories are available, this method bears the risk of getting erroneous results. For this reason, the objective of the present study was to set up a reliable and portable DOC analyzer for on-site analysis. The presented DOC system is equipped with an electrolysis-based decomposition cell with boron-doped diamond electrodes (BDD) that oxidizes the organic compounds to carbon dioxide. Within this study, the influence of different electrode materials and the composition of the applied electrolytes on the DOC decomposition in an undivided electrolytic cell were systematically investigated. Furthermore, some technical aspects of the portable prototype are discussed. After a detailed validation, the prototype was used in an ongoing monitoring program in Northern India. The limit of detection is 0.1 mg L−1 C with a relative standard deviation of 2.3% in a linear range up to 1000 mg L C−1. The key features of the portable DOC analyzer are: No need for ultra-pure gases, catalysts or burning technology, an analyzing time per sample below 5 min, and a reliable on-site DOC determination.
- 1 March 2015
- Published by Elsevier in Water Research
- Vol. 71, 219-226
Novel regeneration method for phosphate loaded granular ferric (hydr)oxide – A contribution to phosphorus recycling
- 1 March 2015
- Published by Elsevier in Water Research
- Vol. 71, 219-226
Novel regeneration method for phosphate loaded granular ferric (hydr)oxide – A contribution to phosphorus recycling
- 22 August 2013
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 62 (7) , 442-451
Limits of UV disinfection: UV/electrolysis hybrid technology as a promising alternative for direct reuse of biologically treated wastewater
- 22 August 2013
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 62 (7) , 442-451
Limits of UV disinfection: UV/electrolysis hybrid technology as a promising alternative for direct reuse of biologically treated wastewater
- Open Access
- 5 April 2012
- Published by Elsevier in Desalination and Water Treatment
- Vol. 46 (1-3) , 160-167
Influence of operating conditions and wastewater-specific parameters on the electrochemical bulk disinfection of biologically treated sewage at boron-doped diamond (BDD) electrodes
The aim of this study was to investigate an electrochemical process for bulk disinfection of biologically treated sewage. The influence of operating conditions (current density and flow rate) on the electrochemical formation of free chlorine in the sewage was determined. Furthermore, the effect of wastewater-specific parameters on the inactivation of Escherichia coli was studied. The disinfection capacity is primarily influenced by the concentration of electrochemically produced free chlorine. The production rate of free chlorine is independent of the flow rate within the range of 25–125 L h−1. The investigations have also shown that the electrochemical disinfection of E. coli in secondary effluents with BDD electrodes proceeds effectively at an electric charge input of 0.1–0.15 Ah L−1 corresponding to an energy expenditure of 2.0–2.6 kWh m−3. The electrochemically generated concentration of free chlorine (c = 0.4–0.6 mg L−1) is sufficient for an E. coli reduction of four log levels under the following conditions: after-reaction time of 15–20 min, T > 6°C, pH < 8.5 and DOC < 22 mg L−1. The formation of organic by-products (AOX, THMs) was marginal to moderate. The inorganic by-products chlorate (1.2 mg L−l) and perchlorate (18 mg L−1) were produced in considerable concentrations.
- 5 April 2012
- Published by Elsevier in Desalination and Water Treatment
- Vol. 46 (1-3) , 160-167
Open AccessInfluence of operating conditions and wastewater-specific parameters on the electrochemical bulk disinfection of biologically treated sewage at boron-doped diamond (BDD) electrodes
The aim of this study was to investigate an electrochemical process for bulk disinfection of biologically treated sewage. The influence of operating conditions (current density and flow rate) on the electrochemical formation of free chlorine in the sewage was determined. Furthermore, the effect of wastewater-specific parameters on the inactivation of Escherichia coli was studied. The disinfection capacity is primarily influenced by the concentration of electrochemically produced free chlorine. The production rate of free chlorine is independent of the flow rate within the range of 25–125 L h−1. The investigations have also shown that the electrochemical disinfection of E. coli in secondary effluents with BDD electrodes proceeds effectively at an electric charge input of 0.1–0.15 Ah L−1 corresponding to an energy expenditure of 2.0–2.6 kWh m−3. The electrochemically generated concentration of free chlorine (c = 0.4–0.6 mg L−1) is sufficient for an E. coli reduction of four log levels under the following conditions: after-reaction time of 15–20 min, T > 6°C, pH < 8.5 and DOC < 22 mg L−1. The formation of organic by-products (AOX, THMs) was marginal to moderate. The inorganic by-products chlorate (1.2 mg L−l) and perchlorate (18 mg L−1) were produced in considerable concentrations.
- 30 September 2010
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 82 (10) , 1781-1788
Use of Diamond Electrodes for the Production of Service Water by Electrochemical Disinfection of Biologically Treated Waste Water
- 30 September 2010
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 82 (10) , 1781-1788
Use of Diamond Electrodes for the Production of Service Water by Electrochemical Disinfection of Biologically Treated Waste Water
- 10 October 2008
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 80 (10) , 1545-1550
Diamantelektroden in der dezentralen Abwasserbehandlung - elektrochemischer Abbau des chemischen Sauerstoffbedarfs organisch hochbelasteter Härtereiabwässer
- 10 October 2008
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 80 (10) , 1545-1550
Diamantelektroden in der dezentralen Abwasserbehandlung - elektrochemischer Abbau des chemischen Sauerstoffbedarfs organisch hochbelasteter Härtereiabwässer