Daniel Cornfeld
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel Cornfeld has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Gary Israel
Department of Diagnostic Imaging, Yale University School of Medicine, PO Box 208042, New Haven, CT 06520
3 shared publicationsHamid Mojibian
Department of Diagnostic Imaging, Yale University School of Medicine, PO Box 208042, New Haven, CT 06520
2 shared publicationsJeffery Weinreb
Department of Diagnostic Radiology, Yale University School of Medicine, 333 Cedar Street, New Haven, CT 06510, United States
2 shared publicationsEzra Detroy
Department of Diagnostic Imaging, Yale University School of Medicine, PO Box 208042, New Haven, CT 06520
1 shared publicationJamal Bokhari
Department of Diagnostic Imaging, Yale University School of Medicine, PO Box 208042, New Haven, CT 06520
1 shared publicationJeffery C. Weinreb
Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, Connecticut
1 shared publication
Latest Publications
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (5) , 702-708
Optimizing Liver Magnetic Resonance Imaging
Purpose The purpose of this study is to determine if a software package (Abdomen DOT; Siemens Medical Systems, Erlangen Germany) designed to automate magnetic resonance imaging (MRI) scans of the liver results in faster and higher quality examinations compared to optimized protocols performed by appropriately trained technologists. Materials and Methods One hundred eight liver MRIs obtained using Abdomen DOT and 94 liver MRIs obtained without Abdomen DOT were retrospectively reviewed. Total scan time and the number of repeated sequences were objectively measured. Timing of the arterial phase, motion artifact, and quality of subtraction images were subjectively evaluated. Results The examinations scanned using Abdomen DOT averaged 2 minutes and 2 seconds shorter than the examinations scanned without Abdomen DOT (P = 0.004) and on average, fewer sequences were repeated. The arterial phase was timed correctly 67% (63/94) of the time without using Abdomen DOT and 81% (87/108) of the time when using Abdomen DOT (P = 0.019). There was no difference in the amount of respiratory artifact. The subtraction images obtained using Abdomen DOT were considered slightly better (P < 0.005 for arterial, portal venous, and equilibrium phase images). Conclusions The Abdomen DOT software helped our technologists scan slightly faster and obtain correctly timed arterial phase images more often.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (5) , 702-708
Optimizing Liver Magnetic Resonance Imaging
Purpose The purpose of this study is to determine if a software package (Abdomen DOT; Siemens Medical Systems, Erlangen Germany) designed to automate magnetic resonance imaging (MRI) scans of the liver results in faster and higher quality examinations compared to optimized protocols performed by appropriately trained technologists. Materials and Methods One hundred eight liver MRIs obtained using Abdomen DOT and 94 liver MRIs obtained without Abdomen DOT were retrospectively reviewed. Total scan time and the number of repeated sequences were objectively measured. Timing of the arterial phase, motion artifact, and quality of subtraction images were subjectively evaluated. Results The examinations scanned using Abdomen DOT averaged 2 minutes and 2 seconds shorter than the examinations scanned without Abdomen DOT (P = 0.004) and on average, fewer sequences were repeated. The arterial phase was timed correctly 67% (63/94) of the time without using Abdomen DOT and 81% (87/108) of the time when using Abdomen DOT (P = 0.019). There was no difference in the amount of respiratory artifact. The subtraction images obtained using Abdomen DOT were considered slightly better (P < 0.005 for arterial, portal venous, and equilibrium phase images). Conclusions The Abdomen DOT software helped our technologists scan slightly faster and obtain correctly timed arterial phase images more often.
- 1 June 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (6) , 905-908
Value of non-contrast sequences in magnetic resonance angiography of hepatic arterial vasculature
- 1 June 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (6) , 905-908
Value of non-contrast sequences in magnetic resonance angiography of hepatic arterial vasculature
- 1 March 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 196 (3) , W336-W340
Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on Radiation Dose and Image Quality in Aortic Dissection Studies: A Qualitative and Quantitative Analysis
OBJECTIVE. The purpose of the study was to quantify the radiation dose reduction achieved when imaging the aorta using Adaptive Statistical Iterative Reconstruction (ASIR) and to determine if this has an effect on image quality.MATERIALS AND METHODS. We retrospectively reviewed 31 CT angiography examinations of the thoracic and abdominal aorta performed with ASIR and 32 consecutive similar examinations performed without ASIR. Volume CT dose index (CTDIvol), dose–length product (DLP), aortic enhancement at multiple levels, aorta-to-muscle contrast-to-noise ratio at multiple levels, and subjective image quality were compared between the two groups.RESULTS. The mean CTDIvol and DLP were significantly lower for the studies performed with ASIR versus studies without ASIR (15.6 vs 21.5 mGy, with an average difference of 5.8 mGy [95% CI 2.3–9.4 mGy] and 818 vs 1075 mGy × cm with an average difference of –257 mGy × cm [54–460 mGy × cm], respectively). Aortic enhancement, aortic signal-to-noise ratio, and aortic t...
- 1 March 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 196 (3) , W336-W340
Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on Radiation Dose and Image Quality in Aortic Dissection Studies: A Qualitative and Quantitative Analysis
OBJECTIVE. The purpose of the study was to quantify the radiation dose reduction achieved when imaging the aorta using Adaptive Statistical Iterative Reconstruction (ASIR) and to determine if this has an effect on image quality.MATERIALS AND METHODS. We retrospectively reviewed 31 CT angiography examinations of the thoracic and abdominal aorta performed with ASIR and 32 consecutive similar examinations performed without ASIR. Volume CT dose index (CTDIvol), dose–length product (DLP), aortic enhancement at multiple levels, aorta-to-muscle contrast-to-noise ratio at multiple levels, and subjective image quality were compared between the two groups.RESULTS. The mean CTDIvol and DLP were significantly lower for the studies performed with ASIR versus studies without ASIR (15.6 vs 21.5 mGy, with an average difference of 5.8 mGy [95% CI 2.3–9.4 mGy] and 818 vs 1075 mGy × cm with an average difference of –257 mGy × cm [54–460 mGy × cm], respectively). Aortic enhancement, aortic signal-to-noise ratio, and aortic t...
- 1 April 2010
- Published by Elsevier in European Journal of Radiology
- Vol. 74 (1) , 241-249
MRI appearance of mesenchymal tumors of the uterus
- 1 April 2010
- Published by Elsevier in European Journal of Radiology
- Vol. 74 (1) , 241-249
MRI appearance of mesenchymal tumors of the uterus
- 1 December 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 193 (6) , W546-W557
Clinical Uses of Time-Resolved Imaging in the Body and Peripheral Vascular System
OBJECTIVE. Time-resolved MR angiography (MRA) is a technique designed for fast vascular imaging. The purpose of this article is to introduce the multiple potential uses for time-resolved MRA in the body and peripheral vascular system in the hope that time-resolved MRA will become a more widely used technique.CONCLUSION. Time-resolved MRA is a useful technique with many clinical applications.
- 1 December 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 193 (6) , W546-W557
Clinical Uses of Time-Resolved Imaging in the Body and Peripheral Vascular System
OBJECTIVE. Time-resolved MR angiography (MRA) is a technique designed for fast vascular imaging. The purpose of this article is to introduce the multiple potential uses for time-resolved MRA in the body and peripheral vascular system in the hope that time-resolved MRA will become a more widely used technique.CONCLUSION. Time-resolved MRA is a useful technique with many clinical applications.
- Open Access
- 25 June 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (1) , 121-127
Pelvic imaging using a t1w fat‐suppressed three‐dimensional dual echo dixon technique at 3T
Purpose: To compare two T1‐weighted (T1W) fat‐suppressed sequences for 3D breath‐hold pre‐ and postcontrast fat‐suppressed T1W imaging of the female pelvis at 3T.Materials and Methods: Pelvic MRI scans of 16 female patients were retrospectively identified who were scanned with two 3D breath‐hold sequences: 1) a fast spoiled gradient echo sequence with spectral inversion at lipids (SPECIAL) (called 3D FSPGR), and 2) a dual‐echo two‐point Dixon (DE Dixon) sequence. Contrast between soft tissue and fat, soft tissue and fluid, and fat and fluid was measured on pre‐ and postcontrast images. Additionally, two readers subjectively scored the images for degree and homogeneity of fat suppression plus presence and severity of artifacts.Results: Contrast between muscle and myometrium to fat was improved with the Dixon technique (0.61 vs. 0.09 and 0.7 vs. 0.3, respectively, P < 0.001). Both readers agreed that fat suppression was stronger with the Dixon sequence (P < 0.001 and P = 0.06). Artifacts were equivalent (P = 0.53 and 0.65).Conclusion: The 3D DE Dixon sequence achieved stronger fat suppression in the female pelvis when compared to a 3D FSPGR sequence with SPECIAL. J. Magn. Reson. Imaging 2008;28:121–127.
- 25 June 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (1) , 121-127
Open AccessPelvic imaging using a t1w fat‐suppressed three‐dimensional dual echo dixon technique at 3T
Purpose: To compare two T1‐weighted (T1W) fat‐suppressed sequences for 3D breath‐hold pre‐ and postcontrast fat‐suppressed T1W imaging of the female pelvis at 3T.Materials and Methods: Pelvic MRI scans of 16 female patients were retrospectively identified who were scanned with two 3D breath‐hold sequences: 1) a fast spoiled gradient echo sequence with spectral inversion at lipids (SPECIAL) (called 3D FSPGR), and 2) a dual‐echo two‐point Dixon (DE Dixon) sequence. Contrast between soft tissue and fat, soft tissue and fluid, and fat and fluid was measured on pre‐ and postcontrast images. Additionally, two readers subjectively scored the images for degree and homogeneity of fat suppression plus presence and severity of artifacts.Results: Contrast between muscle and myometrium to fat was improved with the Dixon technique (0.61 vs. 0.09 and 0.7 vs. 0.3, respectively, P < 0.001). Both readers agreed that fat suppression was stronger with the Dixon sequence (P < 0.001 and P = 0.06). Artifacts were equivalent (P = 0.53 and 0.65).Conclusion: The 3D DE Dixon sequence achieved stronger fat suppression in the female pelvis when compared to a 3D FSPGR sequence with SPECIAL. J. Magn. Reson. Imaging 2008;28:121–127.
- 1 March 2008
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 190 (3) , W218-W221
A Step-by-Step Solution for Embedding User-Controlled Cines into Educational Web Pages
OBJECTIVE. The objective of this article is to introduce a simple method for embedding user-controlled cines into a Web page using a simple JavaScript. Step-by-step instructions are included and the source code is made available. This technique allows the creation of portable Web pages that allow the user to scroll through cases as if seated at a PACS workstation. CONCLUSION. A simple JavaScript allows scrollable image stacks to be included on Web pages. With this technique, you can quickly and easily incorporate entire stacks of CT or MR images into online teaching files. This technique has the potential for use in case presentations, online didactics, teaching archives, and resident testing.
- 1 March 2008
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 190 (3) , W218-W221
A Step-by-Step Solution for Embedding User-Controlled Cines into Educational Web Pages
OBJECTIVE. The objective of this article is to introduce a simple method for embedding user-controlled cines into a Web page using a simple JavaScript. Step-by-step instructions are included and the source code is made available. This technique allows the creation of portable Web pages that allow the user to scroll through cases as if seated at a PACS workstation. CONCLUSION. A simple JavaScript allows scrollable image stacks to be included on Web pages. With this technique, you can quickly and easily incorporate entire stacks of CT or MR images into online teaching files. This technique has the potential for use in case presentations, online didactics, teaching archives, and resident testing.
- 1 February 2008
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 190 (2) , W140-W150
Simple Changes to 1.5-T MRI Abdomen and Pelvis Protocols to Optimize Results at 3 T
OBJECTIVE. Simply transposing 1.5-T abdominal and pelvic MRI protocols to 3-T scanners does not result in optimized images. Simple modifications can be made to preexisting 1.5-T protocols to obtain image quality at 3 T that is comparable to that at 1.5 T. CONCLUSION. We illustrate several simple modifications to 1.5-T body protocols that maintain image quality at 3 T.
- 1 February 2008
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 190 (2) , W140-W150
Simple Changes to 1.5-T MRI Abdomen and Pelvis Protocols to Optimize Results at 3 T
OBJECTIVE. Simply transposing 1.5-T abdominal and pelvic MRI protocols to 3-T scanners does not result in optimized images. Simple modifications can be made to preexisting 1.5-T protocols to obtain image quality at 3 T that is comparable to that at 1.5 T. CONCLUSION. We illustrate several simple modifications to 1.5-T body protocols that maintain image quality at 3 T.
- 31 August 2007
- Published by Elsevier in Magnetic Resonance Imaging Clinics of North America
- Vol. 15 (3) , 433-448
MR Imaging of the Prostate: 1.5T versus 3T
- 31 August 2007
- Published by Elsevier in Magnetic Resonance Imaging Clinics of North America
- Vol. 15 (3) , 433-448
MR Imaging of the Prostate: 1.5T versus 3T
- 4 April 2007
- Published by Springer Nature in Emergency Radiology
- Vol. 14 (5) , 331-335
Torsion of a hyperstimulated ovary during pregnancy: a potentially difficult diagnosis
Ovarian torsion in a pregnant infertility patient is an important and difficult diagnosis to make. We present two cases of torsed hyperstimulated ovaries where grey scale and Doppler sonographic evaluation were inconclusive. In one case, magnetic resonance imaging (MRI) was used to make the diagnosis. In the second case, physical findings observed during the ultrasound exam were diagnostic. We think these two cases are good teaching examples of how to approach this difficult diagnosis and emphasize that MRI and physical exam skills are useful adjuncts to ultrasound in the evaluation of a pregnant patient.
- 4 April 2007
- Published by Springer Nature in Emergency Radiology
- Vol. 14 (5) , 331-335
Torsion of a hyperstimulated ovary during pregnancy: a potentially difficult diagnosis
Ovarian torsion in a pregnant infertility patient is an important and difficult diagnosis to make. We present two cases of torsed hyperstimulated ovaries where grey scale and Doppler sonographic evaluation were inconclusive. In one case, magnetic resonance imaging (MRI) was used to make the diagnosis. In the second case, physical findings observed during the ultrasound exam were diagnostic. We think these two cases are good teaching examples of how to approach this difficult diagnosis and emphasize that MRI and physical exam skills are useful adjuncts to ultrasound in the evaluation of a pregnant patient.