A. Mishra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
A. Mishra has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ken Catchpole
Medical University of South Carolina, Charleston, SC, USA
2 shared publications - Peter McCulloch
Nuffield Department of Surgical Science, University of Oxford, Oxford, UK
2 shared publications A. G. Acheson
Department of Colorectal Surgery Queens Medical Centre Nottingham University Hospitals Nottingham UK
1 shared publicationB. D. Keeler
Department of Colorectal Surgery Queens Medical Centre Nottingham University Hospitals Nottingham UK
1 shared publicationC. Maxwell‐Armstrong
Department of Colorectal Surgery Queens Medical Centre Nottingham University Hospitals Nottingham UK
1 shared publicationJ. A. Simpson
Department of Colorectal Surgery Queens Medical Centre Nottingham University Hospitals Nottingham UK
1 shared publication
Latest Publications
- Open Access
- 1 April 2015
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 97 (3) , 240
Packing of the pelvis following abdominoperineal excision of the rectum
- 1 April 2015
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 97 (3) , 240
Open AccessPacking of the pelvis following abdominoperineal excision of the rectum
- 16 September 2014
- Published by Wiley in Colorectal Disease
- Vol. 16 (10) , 815-821
The influence of laparoscopy on incisional hernia rates: a retrospective analysis of 1057 colorectal cancer resections
Aim: The aim of this study was to evaluate the incidence of incisional hernia formation after laparoscopic and open surgery for colorectal cancer.Method: A retrospective analysis was conducted of 1057 colorectal cancer resection cases (289 laparoscopic, 768 open) performed in a single national laparoscopic training centre between January 2006 and December 2011. Clinical notes and serial computed tomography scans were reviewed, with any incisional hernia including those at a surgical incision, port site, stoma and stoma closure site identified and the size of the defect measured.Results: The overall incisional hernia rate was 14.8%. There was no significant difference between the open and laparoscopic groups (14.4% vs 15.9%, P = 0.566). Excluding stoma‐related hernia, 10.7% of the open group developed a surgical wound hernia, and 11.1% of the laparoscopic group developed a hernia at a port site, extraction site or surgical midline incision. There was no statistical difference between the two groups (P = 0.853). The defects were smaller in the laparoscopic group (P < 0.005). There were significantly more parastomal hernias in the laparoscopic group (40%) than in the open group (12.7%, P < 0.001).Conclusion: The incidence of incisional hernia formation was similar after laparoscopic or open surgery for colorectal cancer. Parastomal hernia was more frequent after laparoscopic surgery.
- 16 September 2014
- Published by Wiley in Colorectal Disease
- Vol. 16 (10) , 815-821
The influence of laparoscopy on incisional hernia rates: a retrospective analysis of 1057 colorectal cancer resections
Aim: The aim of this study was to evaluate the incidence of incisional hernia formation after laparoscopic and open surgery for colorectal cancer.Method: A retrospective analysis was conducted of 1057 colorectal cancer resection cases (289 laparoscopic, 768 open) performed in a single national laparoscopic training centre between January 2006 and December 2011. Clinical notes and serial computed tomography scans were reviewed, with any incisional hernia including those at a surgical incision, port site, stoma and stoma closure site identified and the size of the defect measured.Results: The overall incisional hernia rate was 14.8%. There was no significant difference between the open and laparoscopic groups (14.4% vs 15.9%, P = 0.566). Excluding stoma‐related hernia, 10.7% of the open group developed a surgical wound hernia, and 11.1% of the laparoscopic group developed a hernia at a port site, extraction site or surgical midline incision. There was no statistical difference between the two groups (P = 0.853). The defects were smaller in the laparoscopic group (P < 0.005). There were significantly more parastomal hernias in the laparoscopic group (40%) than in the open group (12.7%, P < 0.001).Conclusion: The incidence of incisional hernia formation was similar after laparoscopic or open surgery for colorectal cancer. Parastomal hernia was more frequent after laparoscopic surgery.
- 1 April 2009
- Published by BMJ in Quality and Safety in Health Care
- Vol. 18 (2) , 104-108
The Oxford NOTECHS System: reliability and validity of a tool for measuring teamwork behaviour in the operating theatre
Introduction: The frequency of adverse events in the operating theatre has been linked to the quality of teamwork and communication. Developing suitable measures of teamwork may play a role in reducing errors in surgery. This study reports on the development and evaluation of a method for measuring operating-theatre teamwork quality. Methods: The Oxford Non-Technical Skills (NOTECHS) scale was developed from an aviation instrument for assessment of non-technical skills. Consultation with experts and task analysis led to modifications reflecting the complexities of the theatre teamwork, particularly the coexistence of three subteams (surgeons, anaesthetists and nurses). The scale was then evaluated using teams performing laparoscopic cholecystectomy (n = 65) before and after teamwork training. Attitudes to teamwork and surgical error rates were assessed by questionnaire and direct observation methods, and used to assess the reliability and validity of the Oxford NOTECHS scale. Results: The interobserver reliability was excellent in 24 operations independently assessed by two observers (Rwg = 0.99), confirmed by a third observer in 11 cases (Rwg = 0.99). Validity was demonstrated through improved scores after teamwork training (t = −3.019, p = 0.005), concurrent with improved attitudes to teamwork after training; inverse correlation between NOTECHS scores and surgical errors (ρ = −0.267, p = 0.046); strong inverse correlation between surgical subteam score and surgical errors (ρ = −0.412, n = 65, p = 0.001); and strong correlation with teamwork scores from an alternative system (n = 5, r = 0.886, p = 0.046) Conclusion: The Oxford NOTECHS scale appears to be a reliable and valid instrument for assessing teamwork in the operating theatre, and is ready for further application.
- 1 April 2009
- Published by BMJ in Quality and Safety in Health Care
- Vol. 18 (2) , 104-108
The Oxford NOTECHS System: reliability and validity of a tool for measuring teamwork behaviour in the operating theatre
Introduction: The frequency of adverse events in the operating theatre has been linked to the quality of teamwork and communication. Developing suitable measures of teamwork may play a role in reducing errors in surgery. This study reports on the development and evaluation of a method for measuring operating-theatre teamwork quality. Methods: The Oxford Non-Technical Skills (NOTECHS) scale was developed from an aviation instrument for assessment of non-technical skills. Consultation with experts and task analysis led to modifications reflecting the complexities of the theatre teamwork, particularly the coexistence of three subteams (surgeons, anaesthetists and nurses). The scale was then evaluated using teams performing laparoscopic cholecystectomy (n = 65) before and after teamwork training. Attitudes to teamwork and surgical error rates were assessed by questionnaire and direct observation methods, and used to assess the reliability and validity of the Oxford NOTECHS scale. Results: The interobserver reliability was excellent in 24 operations independently assessed by two observers (Rwg = 0.99), confirmed by a third observer in 11 cases (Rwg = 0.99). Validity was demonstrated through improved scores after teamwork training (t = −3.019, p = 0.005), concurrent with improved attitudes to teamwork after training; inverse correlation between NOTECHS scores and surgical errors (ρ = −0.267, p = 0.046); strong inverse correlation between surgical subteam score and surgical errors (ρ = −0.412, n = 65, p = 0.001); and strong correlation with teamwork scores from an alternative system (n = 5, r = 0.886, p = 0.046) Conclusion: The Oxford NOTECHS scale appears to be a reliable and valid instrument for assessing teamwork in the operating theatre, and is ready for further application.
- 4 May 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 22 (1) , 68-73
The influence of non-technical performance on technical outcome in laparoscopic cholecystectomy
Evidence from other professions suggests that training in teamwork and general cognitive abilities, collectively described as non-technical skills, may reduce accidents and errors. The relationship between non-technical teamwork skills and technical errors was studied using a behavioural marker system validated in aviation and adapted for use in surgery. 26 elective laparoscopic cholecystectomies were observed. Simultaneous assessments were made of surgical technical errors, by observation clinical human reliability assessment (OCHRA) task analysis, and non-technical performance, using the surgical NOTECHS behavioural marker system. NOTECHS assesses four categories: (1) leadership and management, (2) teamwork cooperation, (3) problem-solving and decision-making, (4) situation awareness. Each subteam (nurses, surgeons and anaesthetists) was scored separately on each of the four dimensions. Two observers – one surgical trainee and one human factors expert – were used to assess intra-rater reliability. The mean NOTECHS team score was 35.5 (95% C.I. ± 1.88). The mean subteam scores for surgeons, anaesthetists and nurses were 13.3 (95% C.I. ± 0.64), 11.4 (95% C.I. ± 1.05), and 10.8 (95% C.I. ± 0.87), respectively, with a significant difference between surgeons and anaesthetists (U = 197, p = 0.009), and surgeons and nurses (U = 0.134, p ≤ 0.001). Inter-rater reliability was found to be strong (α = 0.88). There were between zero and six technical errors per operation, with a mean of 2.62 (95% C.I. ± 0.55), which were negatively correlated with the surgeons situational awareness scores (ρ = –0.718, p < 0.001). Non-technical skills are an important component of surgical skill, particularly in relation to the development and maintenance of a surgeon’s situational awareness. Experience from other industries suggests that it may be possible to improve the ability of surgeons to manage their own situation awareness, through training, intraoperative briefings and intraoperative workload management. In the future, it may be possible to use non-technical performance as a surrogate measure for technical performance, either for early identification of surgical difficulties, or as a method of evaluation by which non-surgically trained observers.
- 4 May 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 22 (1) , 68-73
The influence of non-technical performance on technical outcome in laparoscopic cholecystectomy
Evidence from other professions suggests that training in teamwork and general cognitive abilities, collectively described as non-technical skills, may reduce accidents and errors. The relationship between non-technical teamwork skills and technical errors was studied using a behavioural marker system validated in aviation and adapted for use in surgery. 26 elective laparoscopic cholecystectomies were observed. Simultaneous assessments were made of surgical technical errors, by observation clinical human reliability assessment (OCHRA) task analysis, and non-technical performance, using the surgical NOTECHS behavioural marker system. NOTECHS assesses four categories: (1) leadership and management, (2) teamwork cooperation, (3) problem-solving and decision-making, (4) situation awareness. Each subteam (nurses, surgeons and anaesthetists) was scored separately on each of the four dimensions. Two observers – one surgical trainee and one human factors expert – were used to assess intra-rater reliability. The mean NOTECHS team score was 35.5 (95% C.I. ± 1.88). The mean subteam scores for surgeons, anaesthetists and nurses were 13.3 (95% C.I. ± 0.64), 11.4 (95% C.I. ± 1.05), and 10.8 (95% C.I. ± 0.87), respectively, with a significant difference between surgeons and anaesthetists (U = 197, p = 0.009), and surgeons and nurses (U = 0.134, p ≤ 0.001). Inter-rater reliability was found to be strong (α = 0.88). There were between zero and six technical errors per operation, with a mean of 2.62 (95% C.I. ± 0.55), which were negatively correlated with the surgeons situational awareness scores (ρ = –0.718, p < 0.001). Non-technical skills are an important component of surgical skill, particularly in relation to the development and maintenance of a surgeon’s situational awareness. Experience from other industries suggests that it may be possible to improve the ability of surgeons to manage their own situation awareness, through training, intraoperative briefings and intraoperative workload management. In the future, it may be possible to use non-technical performance as a surrogate measure for technical performance, either for early identification of surgical difficulties, or as a method of evaluation by which non-surgically trained observers.