KNKiyokazu Nakajima

Kiyokazu Nakajima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kiyokazu Nakajima has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The role of intraoperative carbon dioxide insufflating upper gastrointestinal endoscopy during laparoscopic surgery

    by Yoshihito Souma, Kiyokazu Nakajima, Tsuyoshi Takahashi, Junichi Nishimura, Yoshiyuki Fujiwara, Shuji Takiguchi, Hiroshi Miyata, Makoto Yamasaki, Yuichiro Doki, Toshirou Nishida

    Intraoperative endoscopy (IOE) is a useful adjunct during laparoscopic gastrointestinal (GI) surgery. However, one potential hazard of IOE is a prolonged bowel distension due to insufflated air, which may cause obstructed surgical exposure and increased postoperative abdominal pain. Recently, carbon dioxide (CO2), with its rapid absorptive nature, has been proven effective to minimize prolonged bowel distension in ambulatory/intraoperative colonoscopy. The objectives were to assess the feasibility, safety, and efficacy of CO2-insufflating upper GI IOE during laparoscopic surgery. A historical comparison study was performed on the initial ten consecutive patients who underwent CO2-insufflating upper GI IOE (CO2-IOE) during laparoscopic surgery. The control group consisted of the past 12 consecutive patients who underwent conventional air-insufflating upper GI IOE (air-IOE) during laparoscopic surgery. The following parameters were compared between the two groups: (1) patient demographics; (2) feasibility (% completion of IOE); (3) safety (complications related to IOE, impacts on cardiopulmonary status, including systemic blood pressure, heart rate, and end-tidal CO2); (4) efficacy (postoperative residual intestinal gas, time to resume oral intake, and bowel movement). The amounts of post-IOE residual intestinal gas were evaluated and classified on the immediate postoperative abdominal radiographs in a blinded manner. Patient demographics were comparable between the two groups. IOE was completed in both groups without complications. Adverse effects on cardiopulmonary status were not observed during simultaneous intraperitoneal and intraluminal CO2 insufflation. In the air-IOE group, one patient was converted to open surgery because of inadequate surgical exposure from prolonged distension of the downstream bowel. The patients in the CO2-IOE group had significantly lower grade of postoperative bowel distension than the control group. Postoperative oral intake was resumed earlier in the CO2-IOE group. CO2-insufflating upper GI IOE during laparoscopic surgery is feasible, safe, and has a practical advantage in minimizing post-IOE bowel distension compared with conventional air-insufflating upper GI IOE.


  • Transvaginal endoscopic partial gastrectomy in porcine models: the role of an extra endoscope for gastric control

    by Kiyokazu Nakajima, Tsuyoshi Takahashi, Yoshihito Souma, Shinichiro Shinzaki, Takuya Yamada, Toshiyuki Yoshio, Toshirou Nishida

    Transvaginal natural orifice translumenal endoscopic surgery (NOTES) gastrectomy is technically challenging, because wide perigastric dissection under appropriate tissue triangulation is unfeasible with current endoscopic instruments alone. The aim of this study was to investigate the feasibility of transvaginal NOTES gastrectomy with the use of an extra endoscope as a retracting device of the stomach. This acute in vivo feasibility study was performed under the approval of the Institutional Animal Care and Use Committee (IACUC). Four female 40-kg pigs received general anesthesia and underwent transvaginal endoscopic partial gastrectomy. Under laparoscopic guidance, the uterus was fixed anteriorly and transvaginal access was established in a standard fashion. The perigastric ligaments were dissected with needle knife/insulation-tipped electrosurgical knife (IT) via transvaginally placed double-channel endoscope. This step was assisted with the second, CO2-insufflating endoscope advanced in the stomach (i.e., so-called endoscopic gastric control). A linear stapling device with a flexible shaft was then passed transvaginally, and the anterior gastric wall was partially resected. The specimen was isolated and retrieved through the vagina. Concluding endoscopy was carried out to confirm the absence of mucosal damage due to endoscopic gastric control. This was further confirmed at necropsy immediately after sacrifice. All animals underwent successful transvaginal NOTES gastrectomy. Endoscopic gastric control greatly facilitated perigastric dissection by providing appropriate tissue countertraction on the ligaments. Use of transabdominal (laparoscopic) graspers was thus minimized. There were no intraoperative complications directly related to use of the primary (transvaginal) endoscope or the additional (gastric) endoscope. Distention of downstream bowel after gastric insufflation was minimal with CO2. No major injuries were noted on gastric mucosa at postmortem investigations. Transvaginal NOTES partial gastrectomy is feasible in porcine models. Use of an extra endoscope to retract the stomach is effective to minimize transabdominal assistance. Further studies on human subjects are necessary to establish this as a safe and attractive ancillary technique in NOTES.


  • A Simple Technique for Wedge Biopsy of the Liver During Laparoscopic Surgery

    by Kiyokazu Nakajima, Riichiro Nezu, Tomohiko Sakamoto, Fumiaki Sugiura, Noriyuki Yamamura, Toshinori Ito, Toshirou Nishida

    A simple technique for wedge biopsy of the liver, which can be performed concomitantly with laparoscopic surgery, is described in this paper. For this technique, the edge of the liver is clamped with two standard laparoscopic bowel graspers at an approximately 90-degree angle to create a wedge of hepatic tissue for biopsy. A pair of endoscopic scissors is used to excise the specimen between the graspers. The cutting surface of the liver is then coagulated with a monopolar device. This technique is rapid, safe and inexpensive, and requires no specific instruments and/or devices.


  • Carbon dioxide insufflation attenuates parietal blood flow obstruction in distended colon

    by K. Yasumasa, K. Nakajima, S. Endo, T. Ito, H. Matsuda, T. Nishida

    Bowel distention after colonoscopy has been considered as a cause of blood flow disturbance. Carbon dioxide (CO2), with its higher absorbability and vasodilating effect, may reduce parietal blood flow disturbance of distended colon when used for intraluminal insufflation instead of air. The purpose of this study was to assess parietal blood flow of the colon distended with intraluminal air/CO2 insufflation. A 5-cm segment of rat colon was insufflated with either air (air group) or CO2 (CO2 group). Two insufflation methods were employed: temporary insufflation up to an intraluminal pressure of 60 mmHg and continuous insufflation at a pressure of 5, 15, and 30 mmHg. Bowel distention and parietal blood flow measured by laser Doppler imaging were evaluated. For temporary insufflation, bowel distention was prolonged in the air group, whereas it rapidly resolved in the CO2 group. Parietal blood flow decreased in both groups; however, it recovered within 5 min in the CO2 group. For continuous insufflation, under 5 mmHg insufflation, blood flow decreased in the air group, whereas it increased in the CO2 group. Blood flow decreased in both groups under 15 mmHg insufflation; however, it decreased less in the CO2 group. There was a reverse relationship between insufflation pressure and blood flow difference. Inhibition of nitric oxide synthase, ATP-sensitive K+ channel, or heme oxygenase was ineffective against a CO2-induced increase in blood flow. CO2 insufflation preserved parietal blood flow not only by rapid resolution of bowel distention but also by its potential vasodilative effect.


  • A versatile dual-channel carbon dioxide (CO2) insufflator for various CO2 applications

    by K. Nakajima, K. Yasumasa, S. Endo, T. Takahashi, A. Nishitani, R. Nezu, T. Nishida


  • Intraoperative carbon dioxide colonoscopy: a safe insufflation alternative for locating colonic lesions during laparoscopic surgery

    by K. Nakajima, S. W. Lee, T. Sonoda, J. W. Milsom

    Intraoperative colonoscopy (IOC) is useful for locating colonic pathologies during laparoscopy, but bowel distention compromises the subsequent visualization and procedure. Carbon dioxide (CO2), with its rapid absorption, has been proved effective for alleviating bowel distention in ambulatory settings. Its intraoperative role, however, has never been studied. This study aimed to assess the feasibility, safety, and advantages of CO2-insufflated IOC during laparoscopy.