Joachim Windolf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joachim Windolf has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Wolfgang Linhart
University Hospital Hamburg-Eppendorf
2 shared publicationsChristian Gatzka
University Hospital Hamburg-Eppendorf
1 shared publicationDaniel Briem
University Hospital Hamburg-Eppendorf
1 shared publicationDirk A. Hollander
University Hospital of Aachen
1 shared publication- Dirk A. Hollander
Unfallchirurgische Klinik, Universitätsklinikum der RWTH Aachen
1 shared publication - Jo Balzer1 shared publication
Latest Publications
- 11 March 2005
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 125 (3) , 204-208
Treatment of unstable fractures of the pelvic ring in pregnancy
Unstable fractures of the posterior pelvic ring during pregnancy are rare. Pregnancy increases the high demands on the therapy of these types of fractures. The aim of the therapeutic strategy in such a situation is a good functional outcome of the mother without influencing the fetal health. Some osteosynthetic techniques result in good functional outcomes, but they are associated with high amounts of ionizing radiation. We report the case of a pregnant woman who sustained a vertical unstable fracture of the posterior pelvic ring as a result of a traffic accident. The fracture was treated surgically by open reduction and internal fixation with two transiliac reconstruction plates with minimal radiographic exposure to the fetus. One year later, a good functional result concerning the mother was shown. The child was healthy without any signs of prenatal impairment. Surgical treatment of an unstable fracture of the pelvic ring during pregnancy is possible with a justifiable risk to the mother and the child. Consideration of the expected fetal radiation exposure in the course of the therapy is particularly recommended. Using minimal doses of ionizing radiation, the described method results in a good clinical outcome of the mother while simultaneously reducing the radiation exposure of the fetus to an acceptable level.
- 11 March 2005
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 125 (3) , 204-208
Treatment of unstable fractures of the pelvic ring in pregnancy
Unstable fractures of the posterior pelvic ring during pregnancy are rare. Pregnancy increases the high demands on the therapy of these types of fractures. The aim of the therapeutic strategy in such a situation is a good functional outcome of the mother without influencing the fetal health. Some osteosynthetic techniques result in good functional outcomes, but they are associated with high amounts of ionizing radiation. We report the case of a pregnant woman who sustained a vertical unstable fracture of the posterior pelvic ring as a result of a traffic accident. The fracture was treated surgically by open reduction and internal fixation with two transiliac reconstruction plates with minimal radiographic exposure to the fetus. One year later, a good functional result concerning the mother was shown. The child was healthy without any signs of prenatal impairment. Surgical treatment of an unstable fracture of the pelvic ring during pregnancy is possible with a justifiable risk to the mother and the child. Consideration of the expected fetal radiation exposure in the course of the therapy is particularly recommended. Using minimal doses of ionizing radiation, the described method results in a good clinical outcome of the mother while simultaneously reducing the radiation exposure of the fetus to an acceptable level.
- Open Access
- 1 March 2005
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 7 (S01) , S100-S104
Aktuelle Konzepte zur Prophylaxe posttraumatischer Infekte
- 1 March 2005
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 7 (S01) , S100-S104
Open AccessAktuelle Konzepte zur Prophylaxe posttraumatischer Infekte
- 15 April 2004
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 390 (1) , 59-65
Pitfalls and complications in the use of the proximal femoral nail
Osteosynthesis with the proximal femoral nail (PFN) features the advantages of high rotational stability of the head–neck fragment, an unreamed implantation technique and the possibility of static or dynamic distal locking. However, the use of the nail is technically ambitious and is accompanied by some risks of error, which can lead to failure of the osteosynthesis. In this paper we present the results of a critical analysis of mistakes that were made in our hospital during the introduction period of this implant.
- 15 April 2004
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 390 (1) , 59-65
Pitfalls and complications in the use of the proximal femoral nail
Osteosynthesis with the proximal femoral nail (PFN) features the advantages of high rotational stability of the head–neck fragment, an unreamed implantation technique and the possibility of static or dynamic distal locking. However, the use of the nail is technically ambitious and is accompanied by some risks of error, which can lead to failure of the osteosynthesis. In this paper we present the results of a critical analysis of mistakes that were made in our hospital during the introduction period of this implant.
- 1 January 2004
- Published by Springer Nature
- p. 41-47
Auswirkungen der DRG’s auf Behandlungsabläufe und -strategien in der Unfallchirurgie
- 1 January 2004
- Published by Springer Nature
- p. 41-47
Auswirkungen der DRG’s auf Behandlungsabläufe und -strategien in der Unfallchirurgie
- 1 March 2003
- Published by Springer Nature in European Radiology
- Vol. 13 (3) , 612-617
Clinical impact of MRI in acute wrist fractures
The purpose of this study was to evaluate the clinical impact of MRI in the early diagnosis of wrist trauma. High-resolution MR imaging was performed on a 1.5-T unit (Symphony Quantum, Siemens, Erlangen, Germany) using coronal and axial T1- and T2-weighted fat-saturated turbo-spin-echo sequence via a dedicated wrist coil within a mean of 6.6 days after initial radiographs in 54 patients (56 wrists) with clinical suspicion of wrist fractures and normal plain or indistinct radiographs. Initial radiographs were evaluated independently by two senior radiologists and the hand surgeon without knowledge of the MRI findings. The initial treatment protocol was based on evaluation of plain films and clinical findings by the hand surgeon. Treatment protocol was changed after MRI examination if necessary. In 31 of 56 wrists MRI findings resulted in a change of diagnosis. There were false-positive diagnoses on plain radiographs in nearly one half ( n=25) of the patients. False-negative diagnoses on plain radiographs resulted in 6 cases. Magnetic resonance imaging detected additional injuries of soft tissue in more than one third ( n=20). In 22 of 56 wrists the period of immobilization could be shortened or ended, in 12 of 56 it was prolonged, and in 3 of 56 a surgical intervention was necessary. In 19 wrists MRI had no therapeutic consequences. Our data demonstrate the high clinical impact of MRI in the detection of acute wrist fractures. We recommend MRI of the wrist immediately on the day of trauma if there is clinical suspicion and normal plain radiographs. Accurate diagnosis by MRI examination within the first days following trauma may reduce economic costs due to shortened immobilization time in cases with a suspected fracture but plain radiographs.
- 1 March 2003
- Published by Springer Nature in European Radiology
- Vol. 13 (3) , 612-617
Clinical impact of MRI in acute wrist fractures
The purpose of this study was to evaluate the clinical impact of MRI in the early diagnosis of wrist trauma. High-resolution MR imaging was performed on a 1.5-T unit (Symphony Quantum, Siemens, Erlangen, Germany) using coronal and axial T1- and T2-weighted fat-saturated turbo-spin-echo sequence via a dedicated wrist coil within a mean of 6.6 days after initial radiographs in 54 patients (56 wrists) with clinical suspicion of wrist fractures and normal plain or indistinct radiographs. Initial radiographs were evaluated independently by two senior radiologists and the hand surgeon without knowledge of the MRI findings. The initial treatment protocol was based on evaluation of plain films and clinical findings by the hand surgeon. Treatment protocol was changed after MRI examination if necessary. In 31 of 56 wrists MRI findings resulted in a change of diagnosis. There were false-positive diagnoses on plain radiographs in nearly one half ( n=25) of the patients. False-negative diagnoses on plain radiographs resulted in 6 cases. Magnetic resonance imaging detected additional injuries of soft tissue in more than one third ( n=20). In 22 of 56 wrists the period of immobilization could be shortened or ended, in 12 of 56 it was prolonged, and in 3 of 56 a surgical intervention was necessary. In 19 wrists MRI had no therapeutic consequences. Our data demonstrate the high clinical impact of MRI in the detection of acute wrist fractures. We recommend MRI of the wrist immediately on the day of trauma if there is clinical suspicion and normal plain radiographs. Accurate diagnosis by MRI examination within the first days following trauma may reduce economic costs due to shortened immobilization time in cases with a suspected fracture but plain radiographs.
- 1 February 2003
- Published by Springer Nature in Der Unfallchirurg
- Vol. 106 (2) , 127-135
Klinische Relevanz der MRT bei akuten Handgelenkverletzungen
- 1 February 2003
- Published by Springer Nature in Der Unfallchirurg
- Vol. 106 (2) , 127-135
Klinische Relevanz der MRT bei akuten Handgelenkverletzungen
- 1 January 2002
- Published by Elsevier
- p. 87-98
SOFT TISSUE RECONSTRUCTION IN SEVERELY TRAUMATIZED PATIENTS USING HYALURONAN BASED DERMAL AND EPIDERMAL GRAFTS
- 1 January 2002
- Published by Elsevier
- p. 87-98
SOFT TISSUE RECONSTRUCTION IN SEVERELY TRAUMATIZED PATIENTS USING HYALURONAN BASED DERMAL AND EPIDERMAL GRAFTS