Liviu Nicu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Liviu Nicu has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Fabrice Mathieu
Laboratory for Analysis and Architecture of Systems (LAAS), Centre national de la recherche scientifique, Toulouse, France
3 shared publicationsThierry Leïchlé
Nanobiosystems Group, LAAS‐CNRS 7 avenue du Colonel Roche, 31077 Toulouse (France)
3 shared publicationsCaroline Soyer
Institut d'Electronique de Microélectronique et de Nanotechnologie¿Centre National de la Recherche Scientifique (IEMN-CNRS), Villeneuve d'Ascq, France
2 shared publicationsDaisuke Saya
Nanobiosystems Group, Laboratoire d'Analyse et d'Architecture des Systemes-Centre National de la Recherche Scientifique (LAAS¿CNRS), Toulouse, France
2 shared publicationsEmmanuelle Trévisiol
LAAS-CNRS, 7 Avenue du Colonel Roche, 31077 Toulouse, France
2 shared publicationsF. Larramendy
CNRS, LAAS, 7 Avenue du Colonel Roche, F-31400 Toulouse, France
2 shared publications
Latest Publications
- Open Access
- 24 July 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (15) , 1243
Stereolithography 3D Printing of Stimuli-Responsive Spin Crossover@Polymer Nanocomposites with Optimized Actuating Properties
We used stereolithography to print polymer nanocomposite samples of stimuli-responsive spin crossover materials in the commercial photo-curable printing resins DS3000 and PEGDA-250. The thermomechanical analysis of the SLA-printed objects revealed not only the expected reinforcement of the polymer resins by the introduction of the stiffer SCO particles, but also a significant mechanical damping, as well as a sizeable linear strain around the spin transition temperatures. For the highest accessible loads (ca. 13–15 vol.%) we measured transformation strains in the range of 1.2–1.5%, giving rise to peaks in the coefficient of thermal expansion as high as 10−3 °C−1, which was exploited in 3D printed bilayer actuators to produce bending movement. The results pave the way for integrating these advanced stimuli-responsive composites into mechanical actuators and 4D printing applications.
- 24 July 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (15) , 1243
Open AccessStereolithography 3D Printing of Stimuli-Responsive Spin Crossover@Polymer Nanocomposites with Optimized Actuating Properties
We used stereolithography to print polymer nanocomposite samples of stimuli-responsive spin crossover materials in the commercial photo-curable printing resins DS3000 and PEGDA-250. The thermomechanical analysis of the SLA-printed objects revealed not only the expected reinforcement of the polymer resins by the introduction of the stiffer SCO particles, but also a significant mechanical damping, as well as a sizeable linear strain around the spin transition temperatures. For the highest accessible loads (ca. 13–15 vol.%) we measured transformation strains in the range of 1.2–1.5%, giving rise to peaks in the coefficient of thermal expansion as high as 10−3 °C−1, which was exploited in 3D printed bilayer actuators to produce bending movement. The results pave the way for integrating these advanced stimuli-responsive composites into mechanical actuators and 4D printing applications.
- Open Access
- 9 August 2021
- Published by MDPI AG in Magnetochemistry
- Vol. 7 (8) , 114
Investigation of the Effect of Spin Crossover on the Static and Dynamic Properties of MEMS Microcantilevers Coated with Nanocomposite Films of [Fe(Htrz)2(trz)](BF4)@P(VDF-TrFE)
We used a spray-coating process to cover silicon microcantilevers with ca. 33 wt% [Fe(Htrz)2(trz)](BF4)@P(VDF70-TrFE30) nanocomposite thin films of 1500 nm thickness. The bilayer cantilevers were then used to investigate the thermomechanical properties of the composites through a combined static and dynamic flexural analysis. The out-of-plane flexural resonance frequencies were used to assess the Young’s modulus of the spray-coated films (3.2 GPa). Then, the quasi-static flexural bending data allowed us to extract the actuation strain (1.3%) and an actuation stress (7.7 MPa) associated with the spin transition in the composite.
- 9 August 2021
- Published by MDPI AG in Magnetochemistry
- Vol. 7 (8) , 114
Open AccessInvestigation of the Effect of Spin Crossover on the Static and Dynamic Properties of MEMS Microcantilevers Coated with Nanocomposite Films of [Fe(Htrz)2(trz)](BF4)@P(VDF-TrFE)
We used a spray-coating process to cover silicon microcantilevers with ca. 33 wt% [Fe(Htrz)2(trz)](BF4)@P(VDF70-TrFE30) nanocomposite thin films of 1500 nm thickness. The bilayer cantilevers were then used to investigate the thermomechanical properties of the composites through a combined static and dynamic flexural analysis. The out-of-plane flexural resonance frequencies were used to assess the Young’s modulus of the spray-coated films (3.2 GPa). Then, the quasi-static flexural bending data allowed us to extract the actuation strain (1.3%) and an actuation stress (7.7 MPa) associated with the spin transition in the composite.
- Open Access
- 1 March 2016
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 2
A Simple Fabrication Process Based on Micro-masonry for the Realization of Nanoplate Resonators with Integrated Actuation and Detection Schemes
In this work, we use the micro-masonry technique to fabricate nanoplate resonators with integrated electrostatic actuation and capacitive detection in a few steps. Our approach is an alternative solution to the current fabrication methods used to create membranes and plates that usually rely on the selective etching of a sacrificial layer. Highly doped silicon plates were transfer-printed using microtip elastomeric stamps onto insulated bases displaying cavities in order to form suspended structures with airtight gaps. By post-processing adequate interconnections, the fabricated resonators were actuated and their resonant frequency measured in a fully integrated manner. The tested nanoplate devices behave as predicted by theory and offer quality factors of more than 30 in air. Because the cavities used for electrostatic actuation/sensing of the devices are tight sealed, nanoplates fabricated via micro-masonry are suitable for liquid environment operation and are thus a promising solution for biosensing applications.
- 1 March 2016
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 2
Open AccessA Simple Fabrication Process Based on Micro-masonry for the Realization of Nanoplate Resonators with Integrated Actuation and Detection Schemes
In this work, we use the micro-masonry technique to fabricate nanoplate resonators with integrated electrostatic actuation and capacitive detection in a few steps. Our approach is an alternative solution to the current fabrication methods used to create membranes and plates that usually rely on the selective etching of a sacrificial layer. Highly doped silicon plates were transfer-printed using microtip elastomeric stamps onto insulated bases displaying cavities in order to form suspended structures with airtight gaps. By post-processing adequate interconnections, the fabricated resonators were actuated and their resonant frequency measured in a fully integrated manner. The tested nanoplate devices behave as predicted by theory and offer quality factors of more than 30 in air. Because the cavities used for electrostatic actuation/sensing of the devices are tight sealed, nanoplates fabricated via micro-masonry are suitable for liquid environment operation and are thus a promising solution for biosensing applications.
- 14 February 2013
- Published by Elsevier in Microelectronic Engineering
- Vol. 111, 68-76
Reducing parasitic effects of actuation and sensing schemes for piezoelectric microelectromechanical resonators
- 14 February 2013
- Published by Elsevier in Microelectronic Engineering
- Vol. 111, 68-76
Reducing parasitic effects of actuation and sensing schemes for piezoelectric microelectromechanical resonators
- 20 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 59 (9) , 1955-1961
Lead Zirconate Titanate Nanoscale Patterning by Ultraviolet-Based Lithography Lift-Off Technique for Nano-Electromechanical System Applications
The advantage of using lead zirconate titanate (PbZr0.54Ti0.46O3) ceramics as an active material in nanoelectromechanical systems (NEMS) comes from its relatively high piezoelectric coefficients. However, its integration within a technological process is limited by the difficulty of structuring this material with submicrometer resolution at the wafer scale. In this work, we develop a specific patterning method based on optical lithography coupled with a dual-layer resist process. The main objective is to obtain sub-micrometer features by lifting off a 100-nm-thick PZT layer while preserving the material's piezoelectric properties. A subsequent result of the developed method is the ability to stack several layers with a lateral resolution of few tens of nanometers, which is mandatory for the fabrication of NEMS with integrated actuation and read-out capabilities.
- 20 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 59 (9) , 1955-1961
Lead Zirconate Titanate Nanoscale Patterning by Ultraviolet-Based Lithography Lift-Off Technique for Nano-Electromechanical System Applications
The advantage of using lead zirconate titanate (PbZr0.54Ti0.46O3) ceramics as an active material in nanoelectromechanical systems (NEMS) comes from its relatively high piezoelectric coefficients. However, its integration within a technological process is limited by the difficulty of structuring this material with submicrometer resolution at the wafer scale. In this work, we develop a specific patterning method based on optical lithography coupled with a dual-layer resist process. The main objective is to obtain sub-micrometer features by lifting off a 100-nm-thick PZT layer while preserving the material's piezoelectric properties. A subsequent result of the developed method is the ability to stack several layers with a lateral resolution of few tens of nanometers, which is mandatory for the fabrication of NEMS with integrated actuation and read-out capabilities.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 4475-4478
Integrative technology-based approach of microelectromechanical systems (MEMS) for biosensing applications
In this work we simultaneously aim at addressing the design and fabrication of microelectromechanical systems (MEMS) for biological applications bearing actuation and readout capabilities together with adapted tools dedicated to surface functionalization at the microscale. The biosensing platform is based on arrays of silicon micromembranes with piezoelectric actuation and piezoresistive read-out capabilities. The detection of the cytochrome C protein using molecularly imprinted polymers (MIPs) as functional layer is demonstrated. The adapted functionalization tool specifically developed to match the micromembranes' platform is an array of silicon cantilevers incorporating precise force sensors for the trim and force measurements during deposition of biological materials onto the sensors' active area. In either case, associated analog electronics is specifically realized to deal with specific signals treatment fed through the MEMS-based devices.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 4475-4478
Integrative technology-based approach of microelectromechanical systems (MEMS) for biosensing applications
In this work we simultaneously aim at addressing the design and fabrication of microelectromechanical systems (MEMS) for biological applications bearing actuation and readout capabilities together with adapted tools dedicated to surface functionalization at the microscale. The biosensing platform is based on arrays of silicon micromembranes with piezoelectric actuation and piezoresistive read-out capabilities. The detection of the cytochrome C protein using molecularly imprinted polymers (MIPs) as functional layer is demonstrated. The adapted functionalization tool specifically developed to match the micromembranes' platform is an array of silicon cantilevers incorporating precise force sensors for the trim and force measurements during deposition of biological materials onto the sensors' active area. In either case, associated analog electronics is specifically realized to deal with specific signals treatment fed through the MEMS-based devices.
- 8 November 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (2) , 387-390
Three-dimensional closed microfluidic channel fabrication by stepper projection single step lithography: the diabolo effect
Microfluidic devices are currently being used in many types of biochemical microsystems for liquid phase analysis in the frame of medical applications. This paper presents a new technique for the realization of microfluidic channels using SU-8, a commonly used epoxy-based negative photo-resist. These microchannels were fabricated by a single stepper UV-photolithography process. By changing the process parameters, e.g. the optical focus depth and the UV exposure dose, well-defined, covered microchannels with various dimensions and aspect ratios were realized and proven to be effective for the fluid transport by capillarity. This technique can easily be used for the fabrication of microfluidic devices in the microanalysis and lab-on-chip applications realm.
- 8 November 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (2) , 387-390
Three-dimensional closed microfluidic channel fabrication by stepper projection single step lithography: the diabolo effect
Microfluidic devices are currently being used in many types of biochemical microsystems for liquid phase analysis in the frame of medical applications. This paper presents a new technique for the realization of microfluidic channels using SU-8, a commonly used epoxy-based negative photo-resist. These microchannels were fabricated by a single stepper UV-photolithography process. By changing the process parameters, e.g. the optical focus depth and the UV exposure dose, well-defined, covered microchannels with various dimensions and aspect ratios were realized and proven to be effective for the fluid transport by capillarity. This technique can easily be used for the fabrication of microfluidic devices in the microanalysis and lab-on-chip applications realm.
- 6 May 2009
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 138 (2) , 532-538
Parallel acoustic detection of biological warfare agents surrogates by means of piezoelectric immunochips
- 6 May 2009
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 138 (2) , 532-538
Parallel acoustic detection of biological warfare agents surrogates by means of piezoelectric immunochips