Wolfgang Korte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wolfgang Korte has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
Walter F. Riesen
4 shared publicationsKonrad Gabi
Associate Professor
3 shared publicationsChristine Szadkowski
Assistant Professor
2 shared publicationsHanna Engler
2 shared publicationsJochen Lange
Professor, Department of Surgery, Kantonsspital
2 shared publicationsMichael Spannagl
Division of Haemostaseology, University of Munich, Germany
2 shared publications
Latest Publications
- Open Access
- 7 March 2013
- Published by Springer Nature in Thrombosis Journal
- Vol. 11 (1) , 6
Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
Background: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test.Methods: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA.Results: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC’s ranged from 0.04 (FII) to 0.93 (FVIII).Conclusions: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
- 7 March 2013
- Published by Springer Nature in Thrombosis Journal
- Vol. 11 (1) , 6
Open AccessVariability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
Background: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test.Methods: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA.Results: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC’s ranged from 0.04 (FII) to 0.93 (FVIII).Conclusions: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
- 1 January 2013
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 59 (01+02/2013) , 645-57
Performance Evaluation of the Access® FT3 and FT4 Assays, Comparison With Immulite® and AxSYM®, and the Relationship to TSH Values
Different FT3 and FT4 assays report significantly different results. We compared the distribution of FT3 and FT4 in a cohort of Swiss patients measured with DxI 800, AxSYM, and Immulite 2000. TSH, FT3, and FT4 values were measured in 1,938 serum samples. Patients were classified on the basis of their TSH values as low, normal, and high. For each class of TSH values, concordances of FT3 and FT4 results were determined among the three assays. For low TSH values in all three assays FT3 (FT4) concordance of DxI - AxSYM, DxI--Immulite, and AxSYM--Immulite was determined as 83.1%, 76.2% 68.5% (60.8%, 74.6%, 83.1%), for normal TSH as 89.2%, 79.0%, 75.3% (83.9%, 85.5%, 83.1%) and for elevated TSH as 78.0%, 86.0%, 78.0% (84.0%, 90.0%, 90.0%), respectively. Low FT4 concordance rates with DxI 800 were mainly caused by its FT4 upper reference limit of 14.1 pmol/L. Using a cut-off of 16.1 pmol/L concordances with AxSYM and Immulite were improved to 77.7% and 86.9% (low TSH), 92.5% and 96.2% (normal TSH), and 90.0% and 92.2% (high TSH). Low FT3 concordance rates with Immulite were caused by its low FT3 upper reference limit of 6.29 pmol/L as 11.6% of patient samples with normal TSH value showed unusually elevated FT3 results. We showed an overall good concordance of FT3 and FT4 results, when stratified according to corresponding TSH values and the appropriate reference range is used. However, our data also show that problems of interpretation of results based on numerical values have yet not been solved.
- 1 January 2013
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 59 (01+02/2013) , 645-57
Performance Evaluation of the Access® FT3 and FT4 Assays, Comparison With Immulite® and AxSYM®, and the Relationship to TSH Values
Different FT3 and FT4 assays report significantly different results. We compared the distribution of FT3 and FT4 in a cohort of Swiss patients measured with DxI 800, AxSYM, and Immulite 2000. TSH, FT3, and FT4 values were measured in 1,938 serum samples. Patients were classified on the basis of their TSH values as low, normal, and high. For each class of TSH values, concordances of FT3 and FT4 results were determined among the three assays. For low TSH values in all three assays FT3 (FT4) concordance of DxI - AxSYM, DxI--Immulite, and AxSYM--Immulite was determined as 83.1%, 76.2% 68.5% (60.8%, 74.6%, 83.1%), for normal TSH as 89.2%, 79.0%, 75.3% (83.9%, 85.5%, 83.1%) and for elevated TSH as 78.0%, 86.0%, 78.0% (84.0%, 90.0%, 90.0%), respectively. Low FT4 concordance rates with DxI 800 were mainly caused by its FT4 upper reference limit of 14.1 pmol/L. Using a cut-off of 16.1 pmol/L concordances with AxSYM and Immulite were improved to 77.7% and 86.9% (low TSH), 92.5% and 96.2% (normal TSH), and 90.0% and 92.2% (high TSH). Low FT3 concordance rates with Immulite were caused by its low FT3 upper reference limit of 6.29 pmol/L as 11.6% of patient samples with normal TSH value showed unusually elevated FT3 results. We showed an overall good concordance of FT3 and FT4 results, when stratified according to corresponding TSH values and the appropriate reference range is used. However, our data also show that problems of interpretation of results based on numerical values have yet not been solved.
- 1 January 2011
- Published by Georg Thieme Verlag KG in Thrombosis and Haemostasis
- Vol. 105 (05) , 743-749
Peri-operative management of antiplatelet therapy in patients with coronary artery disease
Summary: An increasing number of patients suffering from cardiovascular disease, especially coronary artery disease (CAD), are treated with aspirin and/or clopidogrel for the prevention of major adverse events. Unfortunately, there are no specific, widely accepted recommendations for the perioperative management of patients receiving antiplatelet therapy. Therefore, members of the Perioperative Haemostasis Group of the Society on Thrombosis and Haemostasis Research (GTH), the Perioperative Coagulation Group of the Austrian Society for Anesthesiology, Reanimation and Intensive Care (ÖGARI) and the Working Group Thrombosis of the European Society of Cardiology (ESC) have created this consensus position paper to provide clear recommendations on the perioperative use of antiplatelet agents (specifically with semi-urgent and urgent surgery), strongly supporting a multidisciplinary approach to optimize the treatment of individual patients with coronary artery disease who need major cardiac and non-cardiac surgery. With planned surgery, drug eluting stents (DES) should not be used unless surgery can be delayed for ≥12 months after DES implantation. If surgery cannot be delayed, surgical revascularisation, bare-metal stents or pure balloon angioplasty should be considered. During ongoing antiplatelet therapy, elective surgery should be delayed for the recommended duration of treatment. In patients with semi-urgent surgery, the decision to prematurely stop one or both antiplatelet agents (at least 5 days pre-operatively) has to be taken after multidisciplinary consultation, evaluating the individual thrombotic and bleeding risk. Urgently needed surgery has to take place under full antiplatelet therapy despite the increased bleeding risk. A multidisciplinary approach for optimal antithrombotic and haemostatic patient management is thus mandatory.
- 1 January 2011
- Published by Georg Thieme Verlag KG in Thrombosis and Haemostasis
- Vol. 105 (05) , 743-749
Peri-operative management of antiplatelet therapy in patients with coronary artery disease
Summary: An increasing number of patients suffering from cardiovascular disease, especially coronary artery disease (CAD), are treated with aspirin and/or clopidogrel for the prevention of major adverse events. Unfortunately, there are no specific, widely accepted recommendations for the perioperative management of patients receiving antiplatelet therapy. Therefore, members of the Perioperative Haemostasis Group of the Society on Thrombosis and Haemostasis Research (GTH), the Perioperative Coagulation Group of the Austrian Society for Anesthesiology, Reanimation and Intensive Care (ÖGARI) and the Working Group Thrombosis of the European Society of Cardiology (ESC) have created this consensus position paper to provide clear recommendations on the perioperative use of antiplatelet agents (specifically with semi-urgent and urgent surgery), strongly supporting a multidisciplinary approach to optimize the treatment of individual patients with coronary artery disease who need major cardiac and non-cardiac surgery. With planned surgery, drug eluting stents (DES) should not be used unless surgery can be delayed for ≥12 months after DES implantation. If surgery cannot be delayed, surgical revascularisation, bare-metal stents or pure balloon angioplasty should be considered. During ongoing antiplatelet therapy, elective surgery should be delayed for the recommended duration of treatment. In patients with semi-urgent surgery, the decision to prematurely stop one or both antiplatelet agents (at least 5 days pre-operatively) has to be taken after multidisciplinary consultation, evaluating the individual thrombotic and bleeding risk. Urgently needed surgery has to take place under full antiplatelet therapy despite the increased bleeding risk. A multidisciplinary approach for optimal antithrombotic and haemostatic patient management is thus mandatory.
- 1 November 2010
- Vol. 30 (4) , 212-6
The uncalibrated prothrombinase-induced clotting time test. Equally convenient but more precise than the aPTT for monitoring of unfractionated heparin.
The activated partial thromboplastin time test (aPTT) represents one of the most commonly used diagnostic tools in order to monitor patients undergoing heparin therapy. Expression of aPTT coagulation time in seconds represents common practice in order to evaluate the integrity of the coagulation cascade. The prolongation of the aPTT thus can indicate whether or not the heparin level is likely to be within therapeutic range. Unfortunately aPTT results are highly variable depending on patient properties, manufacturer, different reagents and instruments among others but most importantly aPTT's dose response curve to heparin often lacks linearity. Furthermore, aPTT assays are insensitive to drugs such as, for example, low molecular weight heparin (LMWH) and direct factor Xa (FXa) inhibitors among others. On the other hand, the protrombinase-induced clotting time assay (PiCT®) has been show to be a reliable functional assay sensitive to all heparinoids as well as direct thrombin inhibitors (DTIs). So far, the commercially available PiCT assay (Pefakit®PiCT®, DSM Nutritional Products Ltd. Branch Pentapharm, Basel, Switzerland) is designed to express results in terms of units with the help of specific calibrators, while aPTT results are most commonly expressed as coagulation time in seconds. In this report, we describe the results of a pilot study indicating that the Pefakit PiCT UC assay is superior to the aPTT for the efficient monitoring of patients undergoing UFH therapy; it is also suitable to determine and quantitate the effect of LMWH therapy. This indicates a distinct benefit when using this new approach over the use of aPPT for heparin monitoring.
- 1 November 2010
- Vol. 30 (4) , 212-6
The uncalibrated prothrombinase-induced clotting time test. Equally convenient but more precise than the aPTT for monitoring of unfractionated heparin.
The activated partial thromboplastin time test (aPTT) represents one of the most commonly used diagnostic tools in order to monitor patients undergoing heparin therapy. Expression of aPTT coagulation time in seconds represents common practice in order to evaluate the integrity of the coagulation cascade. The prolongation of the aPTT thus can indicate whether or not the heparin level is likely to be within therapeutic range. Unfortunately aPTT results are highly variable depending on patient properties, manufacturer, different reagents and instruments among others but most importantly aPTT's dose response curve to heparin often lacks linearity. Furthermore, aPTT assays are insensitive to drugs such as, for example, low molecular weight heparin (LMWH) and direct factor Xa (FXa) inhibitors among others. On the other hand, the protrombinase-induced clotting time assay (PiCT®) has been show to be a reliable functional assay sensitive to all heparinoids as well as direct thrombin inhibitors (DTIs). So far, the commercially available PiCT assay (Pefakit®PiCT®, DSM Nutritional Products Ltd. Branch Pentapharm, Basel, Switzerland) is designed to express results in terms of units with the help of specific calibrators, while aPTT results are most commonly expressed as coagulation time in seconds. In this report, we describe the results of a pilot study indicating that the Pefakit PiCT UC assay is superior to the aPTT for the efficient monitoring of patients undergoing UFH therapy; it is also suitable to determine and quantitate the effect of LMWH therapy. This indicates a distinct benefit when using this new approach over the use of aPPT for heparin monitoring.
- 3 September 2010
- Published by Springer Nature
- p. 171-178
Thrombosis and Bleeding in Cancer Patients
- 1 March 2010
- Published by Elsevier in Best Practice & Research Clinical Anaesthesiology
- Vol. 24 (1) , 85-93
F. XIII in perioperative coagulation management
- 1 March 2010
- Published by Elsevier in Best Practice & Research Clinical Anaesthesiology
- Vol. 24 (1) , 85-93
F. XIII in perioperative coagulation management
- 1 January 2010
- Published by Georg Thieme Verlag KG in Hamostaseologie
- Vol. 30 (04) , 212-216
The uncalibrated prothrombinase-induced clotting time test
The activated partial thromboplastin time test (aPTT) represents one of the most commonly used diagnostic tools in order to monitor patients undergoing heparin therapy. Expression of aPTT coagulation time in seconds represents common practice in order to evaluate the integrity of the coagulation cascade. The prolongation of the aPTT thus can indicate whether or not the heparin level is likely to be within therapeutic range. Unfortunately aPTT results are highly variable depending on patient properties, manufacturer, different reagents and instruments among others but most importantly aPTT’s dose response curve to heparin often lacks linearity. Furthermore, aPTT assays are insensitive to drugs such as, for example, low molecular weight heparin (LMWH) and direct factor Xa (FXa) inhibitors among others. On the other hand, the protrombinase-induced clotting time assay (PiCT®) has been show to be a reliable functional assay sensitive to all heparinoids as well as direct thrombin inhibitors (DTIs). So far, the commercially available PiCT assay (Pefakit®-PiCT®, DSM Nutritional Products Ltd. Branch Pentapharm, Basel, Switzerland) is designed to express results in terms of units with the help of specific calibrators, while aPTT results are most commonly expressed as coagulation time in seconds. In this report, we describe the results of a pilot study indicating that the Pefakit PiCT UC assay is superior to the aPTT for the efficient monitoring of patients undergoing UFH therapy; it is also suitable to determine and quantitate the effect of LMWH therapy. This indicates a distinct benefit when using this new approach over the use of aPPT for heparin monitoring. Die aPTT ist eine der meist verwendeten Überwachungsmöglichkeiten bei Patienten mit He-parin-Therapie. Die Beurteilung der Gerin-nungszeit mittels aPTT ist ein viel genutztes Instrument, um die Integrität der Gerinnungskaskade zu untersuchen. Die aPTT-Verlängerung unter Heparin kann daher als Marker dafür verwendet werden, ob der Heparinspiegel im gewünschten therapeutischen Bereich ist. Unglücklicherweise sind die aPTT-Resultate stark abhängig von Patienteneigenschaften, unterschiedlichen Herstellern, verschiedenen Reagenzien und Instrumenten, so dass die Dosisantwort der aPTT auf Heparin oft nicht linear ist. Außerdem ist die aPTT nicht sensitiv genug, um niedermolekulare Heparine bzw. direkte Faktor-Xa-Inhibitoren zu monitieren. An-dererseits ist die PiCT (prothrombinase induced clotting time) ein zuverlässiger funktioneller Assay, um alle Heparin- und Heparinoide sowie direkte Thrombininhibitoren zu monitieren. Bis jetzt wurde der kommerziell erhältliche PiCT-Assay verwendet, um mit Hilfe spezifischer Ka-libratoren die Konzentration der genannten In-hibitoren direkt anzugeben; aPTT-Resultate werden jedoch in Sekunden angegeben. Wir beschreiben die Resultate einer Pilot-Studie, die ergibt, dass die “PiCT-UC” der aPTT zum Monitoring bei Patienten mit unfraktionierter Heparintherapie überlegen ist. PiCT-UC ist auch geeignet den Einfluss von niedrig-molekularem Heparin quantitativ adäquat wi-derzuspiegeln. Diese Resultate zeigen, dass der Gebrauch der PiCT-UC gegenüber dem Gebrauch der aPTT eine deutliche Verbes-serung des Heparin-Monitorings darstellt.
- 1 January 2010
- Published by Georg Thieme Verlag KG in Hamostaseologie
- Vol. 30 (04) , 212-216
The uncalibrated prothrombinase-induced clotting time test
The activated partial thromboplastin time test (aPTT) represents one of the most commonly used diagnostic tools in order to monitor patients undergoing heparin therapy. Expression of aPTT coagulation time in seconds represents common practice in order to evaluate the integrity of the coagulation cascade. The prolongation of the aPTT thus can indicate whether or not the heparin level is likely to be within therapeutic range. Unfortunately aPTT results are highly variable depending on patient properties, manufacturer, different reagents and instruments among others but most importantly aPTT’s dose response curve to heparin often lacks linearity. Furthermore, aPTT assays are insensitive to drugs such as, for example, low molecular weight heparin (LMWH) and direct factor Xa (FXa) inhibitors among others. On the other hand, the protrombinase-induced clotting time assay (PiCT®) has been show to be a reliable functional assay sensitive to all heparinoids as well as direct thrombin inhibitors (DTIs). So far, the commercially available PiCT assay (Pefakit®-PiCT®, DSM Nutritional Products Ltd. Branch Pentapharm, Basel, Switzerland) is designed to express results in terms of units with the help of specific calibrators, while aPTT results are most commonly expressed as coagulation time in seconds. In this report, we describe the results of a pilot study indicating that the Pefakit PiCT UC assay is superior to the aPTT for the efficient monitoring of patients undergoing UFH therapy; it is also suitable to determine and quantitate the effect of LMWH therapy. This indicates a distinct benefit when using this new approach over the use of aPPT for heparin monitoring. Die aPTT ist eine der meist verwendeten Überwachungsmöglichkeiten bei Patienten mit He-parin-Therapie. Die Beurteilung der Gerin-nungszeit mittels aPTT ist ein viel genutztes Instrument, um die Integrität der Gerinnungskaskade zu untersuchen. Die aPTT-Verlängerung unter Heparin kann daher als Marker dafür verwendet werden, ob der Heparinspiegel im gewünschten therapeutischen Bereich ist. Unglücklicherweise sind die aPTT-Resultate stark abhängig von Patienteneigenschaften, unterschiedlichen Herstellern, verschiedenen Reagenzien und Instrumenten, so dass die Dosisantwort der aPTT auf Heparin oft nicht linear ist. Außerdem ist die aPTT nicht sensitiv genug, um niedermolekulare Heparine bzw. direkte Faktor-Xa-Inhibitoren zu monitieren. An-dererseits ist die PiCT (prothrombinase induced clotting time) ein zuverlässiger funktioneller Assay, um alle Heparin- und Heparinoide sowie direkte Thrombininhibitoren zu monitieren. Bis jetzt wurde der kommerziell erhältliche PiCT-Assay verwendet, um mit Hilfe spezifischer Ka-libratoren die Konzentration der genannten In-hibitoren direkt anzugeben; aPTT-Resultate werden jedoch in Sekunden angegeben. Wir beschreiben die Resultate einer Pilot-Studie, die ergibt, dass die “PiCT-UC” der aPTT zum Monitoring bei Patienten mit unfraktionierter Heparintherapie überlegen ist. PiCT-UC ist auch geeignet den Einfluss von niedrig-molekularem Heparin quantitativ adäquat wi-derzuspiegeln. Diese Resultate zeigen, dass der Gebrauch der PiCT-UC gegenüber dem Gebrauch der aPTT eine deutliche Verbes-serung des Heparin-Monitorings darstellt.
- 1 October 2009
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 109 (4) , 1023-1028
In Vitro Inhibition of Factor XIII Retards Clot Formation, Reduces Clot Firmness, and Increases Fibrinolytic Effects in Whole Blood
Ulation factor dependent. Assays with and without platelet inhibition are thus increasingly used to trigger and monitor replacement therapy with blood products. In this study, we evaluated the effect of factor XIII inhibition and additional glycoprotein (GP) IIb/IIIa blockade on (platelet-inhibited) whole blood thrombelastography and whether a modified routine assay (using factor XIII antibody) can be used to detect factor XIII deficiency. METHODS: Normal whole blood was incubated with increasing amounts of a nonspecific antibody, an anti-GPIIb/IIIa antibody, or a neutralizing anti-factor XIII antibody; samples were analyzed with a tissue factor-activated and platelet-inhibited whole blood thrombelastographic assay. Clotting time, clot formation time, maximum clot firmness, and clot lysis at 60 min were evaluated in triplicate. Also, 25 whole blood routine samples were evaluated for factor XIII deficiency using a new thrombelastographic assay incorporating a factor XIII antibody and using a standard factor XIII assay for comparison. RESULTS: Although GPIIb/IIIa inhibition did not alter the results of the platelet-inhibited whole blood thrombelastography, factor XIII inhibition significantly reduced maximum clot firmness (P = 0.020) and increased clot formation time (P = 0.025) and clot lysis (P = 0.007), leaving clotting time unchanged; a ceiling effect seemed to be present with increasing antibody concentrations in whole blood (but not plasma). The thrombelastographic assay for factor XIII deficiency (<70% activity) had a 90% sensitivity and negative predictive value (area under receiver operating characteristic curve 0.803, P = 0.0015); for a deficiency <60%, sensitivity and negative predictive value were 100% (area under receiver operating characteristic curve 0.84, P = 0.0037). CONCLUSION: Factor XIII has significant impact on platelet-inhibited activated whole blood thrombelastography. This phenomenon should be considered when interpreting thrombelastographic results in the bleeding patient, especially when the results trigger procoagulant therapy. Antibody-mediated factor XIII inhibition can be used to establish thrombelastography-based assays to detect factor XIII deficiency....
- 1 October 2009
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 109 (4) , 1023-1028
In Vitro Inhibition of Factor XIII Retards Clot Formation, Reduces Clot Firmness, and Increases Fibrinolytic Effects in Whole Blood
Ulation factor dependent. Assays with and without platelet inhibition are thus increasingly used to trigger and monitor replacement therapy with blood products. In this study, we evaluated the effect of factor XIII inhibition and additional glycoprotein (GP) IIb/IIIa blockade on (platelet-inhibited) whole blood thrombelastography and whether a modified routine assay (using factor XIII antibody) can be used to detect factor XIII deficiency. METHODS: Normal whole blood was incubated with increasing amounts of a nonspecific antibody, an anti-GPIIb/IIIa antibody, or a neutralizing anti-factor XIII antibody; samples were analyzed with a tissue factor-activated and platelet-inhibited whole blood thrombelastographic assay. Clotting time, clot formation time, maximum clot firmness, and clot lysis at 60 min were evaluated in triplicate. Also, 25 whole blood routine samples were evaluated for factor XIII deficiency using a new thrombelastographic assay incorporating a factor XIII antibody and using a standard factor XIII assay for comparison. RESULTS: Although GPIIb/IIIa inhibition did not alter the results of the platelet-inhibited whole blood thrombelastography, factor XIII inhibition significantly reduced maximum clot firmness (P = 0.020) and increased clot formation time (P = 0.025) and clot lysis (P = 0.007), leaving clotting time unchanged; a ceiling effect seemed to be present with increasing antibody concentrations in whole blood (but not plasma). The thrombelastographic assay for factor XIII deficiency (<70% activity) had a 90% sensitivity and negative predictive value (area under receiver operating characteristic curve 0.803, P = 0.0015); for a deficiency <60%, sensitivity and negative predictive value were 100% (area under receiver operating characteristic curve 0.84, P = 0.0037). CONCLUSION: Factor XIII has significant impact on platelet-inhibited activated whole blood thrombelastography. This phenomenon should be considered when interpreting thrombelastographic results in the bleeding patient, especially when the results trigger procoagulant therapy. Antibody-mediated factor XIII inhibition can be used to establish thrombelastography-based assays to detect factor XIII deficiency....
- 1 February 2009
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 110 (2) , 239-245
Factor XIII Substitution in Surgical Cancer Patients at High Risk for Intraoperative Bleeding
Background: Excessive intraoperative bleeding is associated with significant morbidity and mortality. The authors and others have shown that fibrin monomer allows preoperative risk stratification for intraoperative blood loss, likely due to an imbalance between available factor XIII and prothrombin conversion. The authors hypothesized that the use of factor XIII would delay the decrease of clot firmness in high-risk patients. Methods: The concept was tested in a prospective, randomized, double-blind, placebo-controlled trial in elective gastrointestinal cancer surgery. Patients were randomized to receive factor XIII (30 U/kg) or placebo in addition to controlled standard therapy. Results: Twenty-two patients were evaluable for a planned interim analysis. For the primary outcome parameter maximum clot firmness, patients receiving factor XIII showed a nonsignificant 8% decrease, and patients receiving placebo lost 38%, a highly significantly difference between the two groups (P = 0.004). A reduction in the nonprimary outcome parameters fibrinogen consumption (-28%, P = 0.01) and blood loss (-29%, P = 0.041) was also observed in the factor XIII group. Three patients experienced adverse events that seemed unrelated to factor XIII substitution. The trial was stopped early after a planned interim analysis with the primary endpoint reached. Conclusions: This proof of concept study confirms the hypothesis that patients at high risk for intraoperative blood loss show reduced loss of clot firmness when factor XIII is administered early during surgery. Further clinical trials are needed to assess relevant clinical endpoints such as blood loss, loss of other coagulation factors, and use of blood products.
- 1 February 2009
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 110 (2) , 239-245
Factor XIII Substitution in Surgical Cancer Patients at High Risk for Intraoperative Bleeding
Background: Excessive intraoperative bleeding is associated with significant morbidity and mortality. The authors and others have shown that fibrin monomer allows preoperative risk stratification for intraoperative blood loss, likely due to an imbalance between available factor XIII and prothrombin conversion. The authors hypothesized that the use of factor XIII would delay the decrease of clot firmness in high-risk patients. Methods: The concept was tested in a prospective, randomized, double-blind, placebo-controlled trial in elective gastrointestinal cancer surgery. Patients were randomized to receive factor XIII (30 U/kg) or placebo in addition to controlled standard therapy. Results: Twenty-two patients were evaluable for a planned interim analysis. For the primary outcome parameter maximum clot firmness, patients receiving factor XIII showed a nonsignificant 8% decrease, and patients receiving placebo lost 38%, a highly significantly difference between the two groups (P = 0.004). A reduction in the nonprimary outcome parameters fibrinogen consumption (-28%, P = 0.01) and blood loss (-29%, P = 0.041) was also observed in the factor XIII group. Three patients experienced adverse events that seemed unrelated to factor XIII substitution. The trial was stopped early after a planned interim analysis with the primary endpoint reached. Conclusions: This proof of concept study confirms the hypothesis that patients at high risk for intraoperative blood loss show reduced loss of clot firmness when factor XIII is administered early during surgery. Further clinical trials are needed to assess relevant clinical endpoints such as blood loss, loss of other coagulation factors, and use of blood products.
- 1 December 2008
- Vol. 28 (5) , 449-54
[Managing perioperative haemostasis].
Managing perioperative haemostasis starts with the diligently taken patient history. Unfortunately, classic global tests such as the PT and aPTT have no predictive value with regard to an acquired intra- or postoperative bleeding diathesis. However, new assays for preoperative risk stratification are in clinical development. An attribute of good perioperative haemostasis management is the early, multidisciplinary problem assessment. With a preoperatively existing anticoagulation or antiplatelet therapy, perioperative bridging therapy needs to be carefully planned as cardiovascular risk patients have an increased risk of morbidity and mortality when their current anticoagulative therapy is simply stopped. If a haemorrhagic diathesis is known, a specific therapy should be scheduled early preoperatively. When excessive intra- and postoperative bleeding occurs, point of care diagnostics can help to determine the underlying pathophysiology. A predefined validated algorithm reduces the need for blood products. To establish an evidence based approach for the use of blood components and other procoagulants in such a situation requires prospective clinical trials. The actual knowledge on the pathophysiology of such incidents (e. g. cross linking defects by use of colloids, dilutional effects of volume therapy, repeated use of FFP, of antifibrinolytics, frequency of unwanted effects) should also be considered.
- 1 December 2008
- Vol. 28 (5) , 449-54
[Managing perioperative haemostasis].
Managing perioperative haemostasis starts with the diligently taken patient history. Unfortunately, classic global tests such as the PT and aPTT have no predictive value with regard to an acquired intra- or postoperative bleeding diathesis. However, new assays for preoperative risk stratification are in clinical development. An attribute of good perioperative haemostasis management is the early, multidisciplinary problem assessment. With a preoperatively existing anticoagulation or antiplatelet therapy, perioperative bridging therapy needs to be carefully planned as cardiovascular risk patients have an increased risk of morbidity and mortality when their current anticoagulative therapy is simply stopped. If a haemorrhagic diathesis is known, a specific therapy should be scheduled early preoperatively. When excessive intra- and postoperative bleeding occurs, point of care diagnostics can help to determine the underlying pathophysiology. A predefined validated algorithm reduces the need for blood products. To establish an evidence based approach for the use of blood components and other procoagulants in such a situation requires prospective clinical trials. The actual knowledge on the pathophysiology of such incidents (e. g. cross linking defects by use of colloids, dilutional effects of volume therapy, repeated use of FFP, of antifibrinolytics, frequency of unwanted effects) should also be considered.