Sarada Prasad Dakua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sarada Prasad Dakua has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Julien Abinahed
Qatar Robotic Surgery Centre,Qatar Science & Technology Park,Doha,Qatar
4 shared publicationsAbdulla Al-Ansari
Qatar Science & Technology Park
3 shared publicationsA. Al-Ansari
Qatar Foundation
1 shared publicationAbdulla A. Al-Ansari
Department of Urology, Hamad General Hospital, Qatar
1 shared publicationJ. Abi Nahed
Qatar Foundation
1 shared publication
Latest Publications
- 15 November 2016
- Published by Springer Nature in Multidimensional Systems and Signal Processing
- Vol. 29 (1) , 257-277
A PCA-based approach for brain aneurysm segmentation
- 15 November 2016
- Published by Springer Nature in Multidimensional Systems and Signal Processing
- Vol. 29 (1) , 257-277
A PCA-based approach for brain aneurysm segmentation
- 1 January 2016
- Published by Elsevier in Journal of Visual Communication and Image Representation
- Vol. 34, 89-102
Pathological liver segmentation using stochastic resonance and cellular automata
- 1 January 2016
- Published by Elsevier in Journal of Visual Communication and Image Representation
- Vol. 34, 89-102
Pathological liver segmentation using stochastic resonance and cellular automata
- Open Access
- 1 April 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 2 (2) , 024006
Semiautomated hybrid algorithm for estimation of three-dimensional liver surface in CT using dynamic cellular automata and level-sets
Liver segmentation continues to remain a major challenge, largely due to its intense complexity with surrounding anatomical structures (stomach, kidney, and heart), high noise level and lack of contrast in pathological computed tomography (CT) data. We present an approach to reconstructing the liver surface in low contrast CT. The main contributions are: (1) a stochastic resonance-based methodology in discrete cosine transform domain is developed to enhance the contrast of pathological liver images, (2) a new formulation is proposed to prevent the object boundary, resulting from the cellular automata method, from leaking into the surrounding areas of similar intensity, and (3) a level-set method is suggested to generate intermediate segmentation contours from two segmented slices distantly located in a subject sequence. We have tested the algorithm on real datasets obtained from two sources, Hamad General Hospital and medical image computing and computer-assisted interventions grand challenge workshop. Various parameters in the algorithm, such as , , , , , , and , play imperative roles, thus their values are precisely selected. Both qualitative and quantitative evaluation performed on liver data show promising segmentation accuracy when compared with ground truth data reflecting the potential of the proposed method.- 1 April 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 2 (2) , 024006
Open AccessSemiautomated hybrid algorithm for estimation of three-dimensional liver surface in CT using dynamic cellular automata and level-sets
Liver segmentation continues to remain a major challenge, largely due to its intense complexity with surrounding anatomical structures (stomach, kidney, and heart), high noise level and lack of contrast in pathological computed tomography (CT) data. We present an approach to reconstructing the liver surface in low contrast CT. The main contributions are: (1) a stochastic resonance-based methodology in discrete cosine transform domain is developed to enhance the contrast of pathological liver images, (2) a new formulation is proposed to prevent the object boundary, resulting from the cellular automata method, from leaking into the surrounding areas of similar intensity, and (3) a level-set method is suggested to generate intermediate segmentation contours from two segmented slices distantly located in a subject sequence. We have tested the algorithm on real datasets obtained from two sources, Hamad General Hospital and medical image computing and computer-assisted interventions grand challenge workshop. Various parameters in the algorithm, such as , , , , , , and , play imperative roles, thus their values are precisely selected. Both qualitative and quantitative evaluation performed on liver data show promising segmentation accuracy when compared with ground truth data reflecting the potential of the proposed method. - 4 November 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 5 (1) , 54-67
Cellular automata-based left ventricle reconstruction from magnetic resonance images
Despite advanced medical imaging technologies being available, image segmentation still continues to represent a major bottleneck in practical applications due to high noise level and lack of contrast. This paper presents a semi-automatic algorithm that uses stochastic resonance as a pre-processing step for enhancing the contrast of input magnetic resonance (MR) images followed by a cellular automata (CA)-based mechanism for surface reconstruction of the left ventricle (LV) from a few selected MR slices. The main contribution, in this work, is a new formulation for preventing the CA method to leak into surrounding areas of similar intensity. Another contribution is the use of level sets for segmenting the rest of the slices of a subject automatically between the selected slices segmented by the CA to build the LV surface. Both qualitative and quantitative evaluations performed on York and MICCAI Grand Challenge workshop database of MR images show promising segmentation accuracy when compared with the ground truth, reflecting the potential of the proposed method.
- 4 November 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 5 (1) , 54-67
Cellular automata-based left ventricle reconstruction from magnetic resonance images
Despite advanced medical imaging technologies being available, image segmentation still continues to represent a major bottleneck in practical applications due to high noise level and lack of contrast. This paper presents a semi-automatic algorithm that uses stochastic resonance as a pre-processing step for enhancing the contrast of input magnetic resonance (MR) images followed by a cellular automata (CA)-based mechanism for surface reconstruction of the left ventricle (LV) from a few selected MR slices. The main contribution, in this work, is a new formulation for preventing the CA method to leak into surrounding areas of similar intensity. Another contribution is the use of level sets for segmenting the rest of the slices of a subject automatically between the selected slices segmented by the CA to build the LV surface. Both qualitative and quantitative evaluations performed on York and MICCAI Grand Challenge workshop database of MR images show promising segmentation accuracy when compared with the ground truth, reflecting the potential of the proposed method.
- Open Access
- 1 January 2014
- Published by Institution of Engineering and Technology (IET) in IET Image Processing
- Vol. 8 (1) , 1-11
AnnularCut: a graph‐cut design for left ventricle segmentation from magnetic resonance images
Clinician‐friendly methods for cardiac image segmentation in clinical practice remain a tough challenge. Larger standard deviation in segmentation accuracy may be expected for automatic methods when the input dataset is varied; also at some instances the radiologists find them hard in case any correction is desired. In this context, this study presents a semi‐automatic algorithm that uses anisotropic diffusion for smoothing the image and enhancing the edges followed by a new graph‐cut method, ‘AnnularCut’, for three‐dimensional left ventricle (LV) segmentation from some selected slices. Unlike the conventional cellular automata, where the performance depends solely on the image features, this method simultaneously considers the minimal energy between two adjacent regions thus mitigating the convergence problem. The two main contributions in this study can be summarised as (i) a dynamic cellular automation approach to integrate the minimal energy between two distinct labels, and (ii) generation of missing contours of the subject from the selected slices using a level set method to construct the volumetric LV. Both qualitative and quantitative evaluation performed on publicly available databases reflect the potential of the proposed method.
- 1 January 2014
- Published by Institution of Engineering and Technology (IET) in IET Image Processing
- Vol. 8 (1) , 1-11
Open AccessAnnularCut: a graph‐cut design for left ventricle segmentation from magnetic resonance images
Clinician‐friendly methods for cardiac image segmentation in clinical practice remain a tough challenge. Larger standard deviation in segmentation accuracy may be expected for automatic methods when the input dataset is varied; also at some instances the radiologists find them hard in case any correction is desired. In this context, this study presents a semi‐automatic algorithm that uses anisotropic diffusion for smoothing the image and enhancing the edges followed by a new graph‐cut method, ‘AnnularCut’, for three‐dimensional left ventricle (LV) segmentation from some selected slices. Unlike the conventional cellular automata, where the performance depends solely on the image features, this method simultaneously considers the minimal energy between two adjacent regions thus mitigating the convergence problem. The two main contributions in this study can be summarised as (i) a dynamic cellular automation approach to integrate the minimal energy between two distinct labels, and (ii) generation of missing contours of the subject from the selected slices using a level set method to construct the volumetric LV. Both qualitative and quantitative evaluation performed on publicly available databases reflect the potential of the proposed method.
- 14 December 2013
- Published by Springer Nature
- p. 41-52
A Graph Based Methodology for Volumetric Left Ventricle Segmentation
- 14 December 2013
- Published by Springer Nature
- p. 41-52
A Graph Based Methodology for Volumetric Left Ventricle Segmentation
- 1 March 2013
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 1 (1) , 28-36
Use of chaos concept in medical image segmentation
Despite its long track record, segmentation in medical image computing still remains an active field of research, largely due to the complexities of in-vivo anatomical structures, cross-subject and cross-modality variations. Clinically, it has many benefits for effective patient management, both in terms of pre-operative planning and post-operative assessment of the efficacy of therapeutic procedures. Research efforts are focused on novel, clinician friendly, robust and fast segmentation methodologies. In this paper, we present a novel algorithm for efficient segmentation based on Chaotic theory; the preliminary results show the potential of the proposed technique.
- 1 March 2013
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 1 (1) , 28-36
Use of chaos concept in medical image segmentation
Despite its long track record, segmentation in medical image computing still remains an active field of research, largely due to the complexities of in-vivo anatomical structures, cross-subject and cross-modality variations. Clinically, it has many benefits for effective patient management, both in terms of pre-operative planning and post-operative assessment of the efficacy of therapeutic procedures. Research efforts are focused on novel, clinician friendly, robust and fast segmentation methodologies. In this paper, we present a novel algorithm for efficient segmentation based on Chaotic theory; the preliminary results show the potential of the proposed technique.
- 22 December 2011
- Published by Springer Nature in Artificial Intelligence Review
- Vol. 40 (4) , 429-455
Performance divergence with data discrepancy: a review
- 22 December 2011
- Published by Springer Nature in Artificial Intelligence Review
- Vol. 40 (4) , 429-455
Performance divergence with data discrepancy: a review