BSBengt Sandén

Bengt Sandén

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bengt Sandén has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Increased occurrence of spinal fractures related to ankylosing spondylitis: a prospective 22-year cohort study in 17,764 patients from a national registry in Sweden

    by Yohan Robinson, Bengt Sandén, Claes Olerud

    Ankylosing spondylitis (AS) is a rheumatoid disease leading to progressive ossification of the spinal column. Patients suffering from AS are highly susceptible to unstable vertebral fractures and often require surgical stabilisation due to long lever arms. Medical treatment of these patients improved during the last decades, but until now it is unknown whether the annual number of spinal fractures changed during the last years. Since the annual count of fracture is an effective measure for efficacy of injury prevention and patient safety in AS patients, the current recommendations of activity have to be revised accordingly.


  • Improved extraction torque of hydroxyapatite-coated pedicle screws

    by B. Sandén, Claes Olerud, Carina Johansson, Sune Larsson

    Loosening of the screws is a problem in instrumentation with pedicle screws. Coating with hydroxyapatite improves the holding characteristics for metal implants, but the possible effects on the anchorage of pedicle screws have not been described. In this study, seven patients were operated on with spinal instrumentation using four stainless steel pedicle screws. Hydroxyapatite-coated screws were used in either the upper or the lower of the instrumented levels. The insertion torque was measured. In four cases the screws were removed after 10–22 months and the extraction torque was measured. The mean insertion torque was found to be significantly greater in the hydroxyapatite-coated screws (107 Ncm) than in the standard screws (76 Ncm). In three cases, the extraction torque for the hydroxyapatite-coated screws exceeded the range for the torque wrench (600 Ncm), while the conventional screws were loose (< 5 Ncm). In one case, the extraction torque was 475 and 550 Ncm for the coated screws, and 5 and 25 Ncm for the conventional screws. The difference in extraction torque was significant. Hydroxyapatite coating was shown to have improved the purchase of pedicle screws very effectively. By using fully coated screws, as in the present study, extraction was extremely difficult compared to extraction of conventional stainless steel screws, which were regularly loose. By reducing the area of the screws that is coated, it may be possible to achieve an enhanced purchase while extraction will be easier when compared to fully coated screws.