Ulrich Flenker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ulrich Flenker has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Carmen Weigt
German Sports University Cologne, Institute of Cardiovascular Research and Sports Medicine, Department of Cellular and Molecular Sports Medicine, Am Sportpark Müngersdorf 6, 50933 Köln, Germany
1 shared publication - Frank Hülsemann
Institute of Biochemistry German Sport University Cologne Cologne Germany
1 shared publication - Karl Heinrich Fritzemeier
University of Essen-Duisburg, Universitätsstraße 2, 45141 Essen, Germany
1 shared publication Katja Ickstadt
Faculty of Statistics TU Dortmund University 44221 Dortmund Germany
1 shared publicationLeo N. Geppert
Faculty of Statistics TU Dortmund University 44221 Dortmund Germany
1 shared publication- Michael Ernest Boettcher
Geochemistry & Isotope Biogeochemistry Group, Leibniz Institute for Baltic Sea Research (IOW), Warnemünde, Germany
1 shared publication
Latest Publications
- 30 January 2018
- Published by Taylor & Francis in Isotopes in Environmental and Health Studies
- Vol. 54 (4) , 446-448
The what, where, how and who? Crime time and mass discrimination
- 30 January 2018
- Published by Taylor & Francis in Isotopes in Environmental and Health Studies
- Vol. 54 (4) , 446-448
The what, where, how and who? Crime time and mass discrimination
- 12 September 2012
- Published by Wiley in Drug Testing and Analysis
- Vol. 4 (12) , 893-896
Isotope ratio mass spectrometry – history and terminology in brief
The history of isotope ratio mass spectrometry (IRMS) is briefly described. It is shown that the fundamental design of isotope ratio mass spectrometers has not changed since the 1940s. The basic findings concerning the natural variation of isotope abundances even date back to the 1930s. Recent improvements in the methodology mainly concern online coupling and analytical peripherals. The nature of isotopic scales necessitates a specific terminology which is unfamiliar to many analysts. However, corresponding guidelines exist that should be adopted by the anti‐doping community. Currently, steroids represent the only group of compounds routinely analyzed by IRMS in doping‐control. Suggestions are made in respect to a harmonized terminology concerning the nature and origins of steroids. Copyright © 2012 John Wiley & Sons, Ltd.
- 12 September 2012
- Published by Wiley in Drug Testing and Analysis
- Vol. 4 (12) , 893-896
Isotope ratio mass spectrometry – history and terminology in brief
The history of isotope ratio mass spectrometry (IRMS) is briefly described. It is shown that the fundamental design of isotope ratio mass spectrometers has not changed since the 1940s. The basic findings concerning the natural variation of isotope abundances even date back to the 1930s. Recent improvements in the methodology mainly concern online coupling and analytical peripherals. The nature of isotopic scales necessitates a specific terminology which is unfamiliar to many analysts. However, corresponding guidelines exist that should be adopted by the anti‐doping community. Currently, steroids represent the only group of compounds routinely analyzed by IRMS in doping‐control. Suggestions are made in respect to a harmonized terminology concerning the nature and origins of steroids. Copyright © 2012 John Wiley & Sons, Ltd.
- 12 September 2012
- Published by Wiley in Drug Testing and Analysis
- Vol. 4 (12) , 934-941
Validity of stable isotope data in doping control: perspectives and proposals
Δ13C and δ13C values of endogenous urinary steroids represent physiological random variables. Measurement uncertainty and biological scatter likewise contribute to the variances. The statistical distributions of negative controls are well investigated, but there is little knowledge about the corresponding distributions of steroid‐users. For these reasons valid discrimination of steroid users from non‐users by 13C/12C analysis of endogenous steroids requires elaborate statistical treatment. Corresponding Bayesian approaches are presented following an introduction to the rationale. The use of mixture models appears appropriate. The distribution of routine data has been deconvolved and characterized accordingly. The mixture components, which presumably represent steroid users and non‐users, exhibit considerable overlap. The validity of a given result depends on both the analytical uncertainty and the prior probability of doping offenses. Low analytical uncertainties but high prior probabilities facilitate valid detection of doping offenses. Two recommendations can be deduced. First, before starting an 13C/12C analysis, any initial suspicion should be well‐substantiated. This precludes use of permissive criteria derived from the steroid profile. Secondly, knowledge of relevant 13C/12C distributions is required. This must cover representative numbers of authentic steroid users. Finally, it is desirable that the conditional probability for steroid administration rather than the measurement uncertainty is calculated and reported. This quantity possesses superior validity and it is largely independent of laboratory bias. The findings suggest and facilitate flexible handling of decision limits. Proposals for the evaluation of stable isotope data are presented. Copyright © 2012 John Wiley & Sons, Ltd.
- 12 September 2012
- Published by Wiley in Drug Testing and Analysis
- Vol. 4 (12) , 934-941
Validity of stable isotope data in doping control: perspectives and proposals
Δ13C and δ13C values of endogenous urinary steroids represent physiological random variables. Measurement uncertainty and biological scatter likewise contribute to the variances. The statistical distributions of negative controls are well investigated, but there is little knowledge about the corresponding distributions of steroid‐users. For these reasons valid discrimination of steroid users from non‐users by 13C/12C analysis of endogenous steroids requires elaborate statistical treatment. Corresponding Bayesian approaches are presented following an introduction to the rationale. The use of mixture models appears appropriate. The distribution of routine data has been deconvolved and characterized accordingly. The mixture components, which presumably represent steroid users and non‐users, exhibit considerable overlap. The validity of a given result depends on both the analytical uncertainty and the prior probability of doping offenses. Low analytical uncertainties but high prior probabilities facilitate valid detection of doping offenses. Two recommendations can be deduced. First, before starting an 13C/12C analysis, any initial suspicion should be well‐substantiated. This precludes use of permissive criteria derived from the steroid profile. Secondly, knowledge of relevant 13C/12C distributions is required. This must cover representative numbers of authentic steroid users. Finally, it is desirable that the conditional probability for steroid administration rather than the measurement uncertainty is calculated and reported. This quantity possesses superior validity and it is largely independent of laboratory bias. The findings suggest and facilitate flexible handling of decision limits. Proposals for the evaluation of stable isotope data are presented. Copyright © 2012 John Wiley & Sons, Ltd.
- 24 September 2009
- Published by Taylor & Francis in Bioanalysis
- Vol. 1 (6) , 1119-1129
Stable Isotope Analysis of the Bioelements: An Introduction
The abundances of the stable isotopes of the bioelements are not constant. Subtle, but significant, variations may be induced by physical, physiological and biochemical processes. These variations may be detected and quantified. Often, isotope fingerprints are characteristic of certain processes and may reveal information concerning the sources and origins of compounds of interest. Moreover, natural variabilities of stable isotopes may be exploited in order to perform tracer experiments. The most accurate technology to perform stable isotope analysis is (gas) isotope ratio MS (IRMS). Compound-specific approaches employ hyphenation of GC and LC to IRMS. In these approaches, complete conversion to simple gases prior to MS is required. Analysis by stable isotope ratio spectroscopy currently approaches the accuracy of IRMS. However, for bioanalytical projects, it is still predominantly confined to material synthetically enriched with stable isotopes.
- 24 September 2009
- Published by Taylor & Francis in Bioanalysis
- Vol. 1 (6) , 1119-1129
Stable Isotope Analysis of the Bioelements: An Introduction
The abundances of the stable isotopes of the bioelements are not constant. Subtle, but significant, variations may be induced by physical, physiological and biochemical processes. These variations may be detected and quantified. Often, isotope fingerprints are characteristic of certain processes and may reveal information concerning the sources and origins of compounds of interest. Moreover, natural variabilities of stable isotopes may be exploited in order to perform tracer experiments. The most accurate technology to perform stable isotope analysis is (gas) isotope ratio MS (IRMS). Compound-specific approaches employ hyphenation of GC and LC to IRMS. In these approaches, complete conversion to simple gases prior to MS is required. Analysis by stable isotope ratio spectroscopy currently approaches the accuracy of IRMS. However, for bioanalytical projects, it is still predominantly confined to material synthetically enriched with stable isotopes.
- 17 September 2009
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 15 (1) , 53-55
Comment on “Validation of specificity in doping control: problems and prospects”
- 17 September 2009
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 15 (1) , 53-55
Comment on “Validation of specificity in doping control: problems and prospects”
- 1 April 2009
- Published by Future Science Ltd in Bioanalysis
- Vol. 1 (1) , 13-16
Conference Report – Recent developments in stable isotope research: Joint European Stable Isotope User Meeting 2008
A rapidly increasing number of applications are currently emerging from stable isotope research whilst, at the same time, significant evolution of the instrumentation may also be observed. The European stable isotope community gathered in Giens, France, to exchange views and discuss recent developments.
- 1 April 2009
- Published by Future Science Ltd in Bioanalysis
- Vol. 1 (1) , 13-16
Conference Report – Recent developments in stable isotope research: Joint European Stable Isotope User Meeting 2008
A rapidly increasing number of applications are currently emerging from stable isotope research whilst, at the same time, significant evolution of the instrumentation may also be observed. The European stable isotope community gathered in Giens, France, to exchange views and discuss recent developments.
- 1 June 2001
- Published by Taylor & Francis in European Journal of Sport Science
- Vol. 1 (2) , 1-5
Caffeine in doping control: Determination of 13 C in urinary excreted caffeine
The ratio of the 2 stable carbon isotopes 13C and 12C reveals synthetic or natural origin of caffeine. 13C was measured in caffeine isolated from several beverages, several pharmaceutical preparations, and in caffeine obtained from urine samples collected during routine doping controls. Caffeine in soft drinks, “energy drinks,” and pharmaceutical products showed 13C depletion typical for synthetic material. Urinary caffeine mostly showed values typical for tea or coffee products. One urine sample testing positive for caffeine showed evidence for synthetic material. This sample contained 25 μg/ml caffeine, whereas a threshold level of 12 μg/ml has been established by sports federations.
- 1 June 2001
- Published by Taylor & Francis in European Journal of Sport Science
- Vol. 1 (2) , 1-5
Caffeine in doping control: Determination of 13 C in urinary excreted caffeine
The ratio of the 2 stable carbon isotopes 13C and 12C reveals synthetic or natural origin of caffeine. 13C was measured in caffeine isolated from several beverages, several pharmaceutical preparations, and in caffeine obtained from urine samples collected during routine doping controls. Caffeine in soft drinks, “energy drinks,” and pharmaceutical products showed 13C depletion typical for synthetic material. Urinary caffeine mostly showed values typical for tea or coffee products. One urine sample testing positive for caffeine showed evidence for synthetic material. This sample contained 25 μg/ml caffeine, whereas a threshold level of 12 μg/ml has been established by sports federations.