SWSiegbert Witkowski

Siegbert Witkowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Siegbert Witkowski has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Implementation of Fused Filament Fabrication in Dentistry

    by Jörg Lüchtenborg, Felix Burkhardt, Julian Nold, Severin Rothlauf, Christian Wesemann, Stefano Pieralli, Gregor Wemken, Siegbert Witkowski, Benedikt C. Spies

    Additive manufacturing is becoming an increasingly important technique for the production of dental restorations and assistive devices. The most commonly used systems are based on vat polymerization, e.g., stereolithography (SLA) and digital light processing (DLP). In contrast, fused filament fabrication (FFF), also known under the brand name fused deposition modeling (FDM), is rarely applied in the dental field. This might be due to the reduced accuracy and resolution of FFF compared to vat polymerization. However, the use of FFF in the dental sector seems very promising for in-house production since it presents a cost-effective and straight forward method. The manufacturing of nearly ready-to-use parts with only minimal post-processing can be considered highly advantageous. Therefore, the objective was to implement FFF in a digital dental workflow. The present report demonstrates the production of surgical guides for implant insertion by FFF. Furthermore, a novel approach using a temperature-sensitive filament for bite registration plates holds great promise for a simplified workflow. In combination with a medical-grade filament, a multi-material impression tray was printed for optimized impression taking of edentulous patients. Compared to the conventional way, the printed thermoplastic material is pleasant to model and can allow clean and fast work on the patient.


  • Open Access

    Does Printing Orientation Matter? In-Vitro Fracture Strength of Temporary Fixed Dental Prostheses after a 1-Year Simulation in the Artificial Mouth

    by Julian Nold, Christian Wesemann, Laura Rieg, Lara Binder, Siegbert Witkowski, Benedikt Christopher Spies, Ralf Joachim Kohal

    Computer-aided design and computer-aided manufacturing (CAD–CAM) enable subtractive or additive fabrication of temporary fixed dental prostheses (FDPs). The present in-vitro study aimed to compare the fracture resistance of both milled and additive manufactured three-unit FDPs and bar-shaped, ISO-conform specimens. Polymethylmethacrylate was used for subtractive manufacturing and a light-curing resin for additive manufacturing. Three (bars) and four (FDPs) different printing orientations were evaluated. All bars (n = 32) were subjected to a three-point bending test after 24 h of water storage. Half of the 80 FDPs were dynamically loaded (250,000 cycles, 98 N) with simultaneous hydrothermal cycling. Non-aged (n = 40) and surviving FDPs (n = 11) were subjected to static loading until fracture. Regarding the bar-shaped specimens, the milled group showed the highest flexural strength (114 ± 10 MPa, p = 0.001), followed by the vertically printed group (97 ± 10 MPa, p < 0.007). Subtractive manufactured FDPs revealed the highest fracture strength (1060 ± 89 N) with all specimens surviving dynamic loading. During artificial aging, 29 of 32 printed specimens failed. The present findings indicate that both printing orientation and aging affect the strength of additive manufactured specimens. The used resin and settings cannot be recommended for additive manufacturing of long-term temporary three-unit FDPs.


  • Reliability of shade selection using an intraoral spectrophotometer

    by Siegbert Witkowski, Nao-Daniel Yajima, Martin Wolkewitz, Jorge R. Strub

    In this study, we evaluate the accuracy and reproducibility of human tooth shade selection using a digital spectrophotometer. Variability among examiners and illumination conditions were tested for possible influence on measurement reproducibility. Fifteen intact anterior teeth of 15 subjects were evaluated for their shade using a digital spectrophotometer (Crystaleye®, Olympus, Tokyo, Japan) by two examiners under the same light conditions representing a dental laboratory situation. Each examiner performed the measurement ten times on the labial surface of each tooth containing three evaluation sides (cervical, body, incisal). Commission International on Illumination color space values for L* (lightness), a* (red/green), and b* (yellow/blue) were obtained from each evaluated side. Examiner 2 repeated the measurements of the same subjects under different light conditions (i.e., a dental unit with a chairside lamp). To describe measurement precision, the mean color difference from the mean metric was used. The computed confidence interval (CI) value 5.228 (4.6598–5.8615) reflected (represented) the validity of the measurements. Least square mean analysis of the values obtained by examiners 1 and 2 or under different illumination conditions revealed no statistically significant differences (CI = 95%). Within the limits of the present study, the accuracy and reproducibility of dental shade selection using the tested spectrophotometer with respect to examiner and illumination conditions reflected the reliability of this device. This study suggests that the tested spectrophotometer can be recommended for the clinical application of shade selection.


    • 1 January 2007
      • Vol. 2  (1) , 80-98

    Three-dimensional navigation in implant dentistry.

    by Pascal Marquardt, Siegbert Witkowski, Jörg Strub

    In implant dentistry today, precise preoperative planning of both the implant placement and the restoration is a critical prerequisite to succeeding in the oral rehabilitation of patients with dental implants. Modern three-dimensional imaging techniques such as digital volume tomography allow the acquisition of radiologic data with very low levels of radiation and excellent image accuracy, and also allow the processing of these data with various types of software applications. Formerly, only the position of the implant collar or the axis of the osteotomy could be transferred into the clinical setting; it is now possible to predetermine the precise three-dimensional position of the planned implant before the actual implant insertion, and to transfer this position to the surgical site. Thus, the restoration can be fabricated before surgery and can be placed into the patient's mouth immediately after surgery. Treatment planned in this way is fast, minimally invasive, and most importantly, predictable. This increases the quality of both the surgical procedure and the restoration. For three-dimensional navigation in implant dentistry there are static systems based on both surgical guides and optical, dynamic navigation systems. This article is an overview of the latest systems for guided implant insertion and their fields of application.


    • 1 January 2006
      • Vol. 1  (4) , 326-39

    Improved communication during treatment planning using light-curing hybrid wax for esthetic try-in restorations.

    by Siegbert Witkowski, Andreas Kunz, Günther Wagenknecht

    The chance for a successful restorative outcome is improved when the clinician, the laboratory technician, and the patient agree on the design and appearance of the planned dental prosthesis as early as possible. A try-in of a planned dental restoration in the patient's mouth provides the parties involved in treatment planning with the ability to determine treatment goals together. The following article describes the use of a novel light-curing hybrid wax, a resin-like material that allows natural-looking, fracture-proof esthetic try-in restorations. Corrections can be made chairside by adding or removing material. The material is suitable for all indications involving fixed or removable dentures. Moreover, as the material can be burned without producing residues, it can be used directly in other applications such as pressable ceramics, ceramics pressed to metal, and casting techniques. A clinical case demonstrating the use of the hybrid wax is also presented.