Jessica Schulz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jessica Schulz has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Maxim Zaitsev
Division of Medical Physics, Department of Radiology, University Medical Center Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany
2 shared publications Christian Labadie
Max Planck Institute for Human Cognitive and Brain Sciences
1 shared publicationEnrico Reimer
Max Planck Institute for Human Cognitive and Brain Sciences
1 shared publicationJ. Maclaren
1 shared publicationJulian Maclaren
Stanford University
1 shared publicationM. Herbst
1 shared publication
Latest Publications
- 1 January 2014
- Published by Elsevier in NeuroImage
- Vol. 84, 124-132
Prospective slice-by-slice motion correction reduces false positive activations in fMRI with task-correlated motion
- 1 January 2014
- Published by Elsevier in NeuroImage
- Vol. 84, 124-132
Prospective slice-by-slice motion correction reduces false positive activations in fMRI with task-correlated motion
- 13 June 2012
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 25 (6) , 443-453
An embedded optical tracking system for motion-corrected magnetic resonance imaging at 7T
Prospective motion correction using data from optical tracking systems has been previously shown to reduce motion artifacts in MR imaging of the head. We evaluate a novel optical embedded tracking system. The home-built optical embedded tracking system performs image processing within a 7T scanner bore, enabling high speed tracking. Corrected and uncorrected in vivo MR volumes are acquired interleaved using a modified 3D FLASH sequence, and their image quality is assessed and compared. The latency between motion and correction of the slice position was measured to be (19 ± 5) ms, and the tracking noise has a standard deviation no greater than 10 μm/0.005° during conventional MR scanning. Prospective motion correction improved the edge strength by 16 % on average, even though the volunteers were asked to remain motionless during the acquisitions. Using a novel method for validating the effectiveness of in vivo prospective motion correction, we have demonstrated that prospective motion correction using motion data from the embedded tracking system considerably improved image quality.
- 13 June 2012
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 25 (6) , 443-453
An embedded optical tracking system for motion-corrected magnetic resonance imaging at 7T
Prospective motion correction using data from optical tracking systems has been previously shown to reduce motion artifacts in MR imaging of the head. We evaluate a novel optical embedded tracking system. The home-built optical embedded tracking system performs image processing within a 7T scanner bore, enabling high speed tracking. Corrected and uncorrected in vivo MR volumes are acquired interleaved using a modified 3D FLASH sequence, and their image quality is assessed and compared. The latency between motion and correction of the slice position was measured to be (19 ± 5) ms, and the tracking noise has a standard deviation no greater than 10 μm/0.005° during conventional MR scanning. Prospective motion correction improved the edge strength by 16 % on average, even though the volunteers were asked to remain motionless during the acquisitions. Using a novel method for validating the effectiveness of in vivo prospective motion correction, we have demonstrated that prospective motion correction using motion data from the embedded tracking system considerably improved image quality.