Rosemary M. Killen
Rosemary M. Killen has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Menelaos Sarantos
NASA Goddard Space Flight Center
3 shared publications Andrew E. Potter
National Solar Observatory
2 shared publicationsAnn L. Sprague
University of Arizona
2 shared publications- Anna Milillo
INAF
2 shared publications - Gabrielle Cremonese
Osservatorio Astronomico di Padova
2 shared publications Helmut Lammer
Austrian Academy of Sciences
2 shared publications
Latest Publications
- 18 September 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10769, 107690I
Overview of Phobos/Deimos Regolith Ion Sample Mission (PRISM) concept
Far more definitive information on composition is required to resolve the question of origin for the Martian moons Phobos and Deimos. Current infrared spectra of the objects are inconclusive due to the lack of strong diagnostic features. Definitive compositional measurements of Phobos could be obtained using in-situ X-ray, gamma-ray, or neutron spectroscopy or collecting and returning samples to Earth for analysis. We have proposed, in lieu of those methods, to derive Phobos and Deimos compositional data from secondary ion mass spectrometry (SIMS) measurements by calibrating the instrument to elemental abundance measurements made for known samples in the laboratory. We describe the Phobos/Deimos Regolith Ion Sample Mission (PRISM) concept here. PRISM utilizes a high-resolution TOF plasma composition analyzer to make SIMS measurements by observing the sputtered species from various locations of the moons' surfaces. In general, the SIMS technique and ion mass spectrometers complement and expand quadrupole mass spectrometer measurements by collecting ions that have been energized to higher energies, 50-100 eV, and making measurements at very low densities and pressures. Furthermore, because the TOF technique accepts all masses all the time, it obtains continuous measurements and does not require stepping through masses. The instrument would draw less than 10 W and weigh less than 5 kg. The spacecraft, nominally a radiation-hardened 12U CubeSat, would use a low-thrust Solar Electric Propulsion system to send it on a two-year journey to Mars, where it would co-orbit with Deimos and then Phobos at distances as low as 27 km.
- 18 September 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10769, 107690I
Overview of Phobos/Deimos Regolith Ion Sample Mission (PRISM) concept
Far more definitive information on composition is required to resolve the question of origin for the Martian moons Phobos and Deimos. Current infrared spectra of the objects are inconclusive due to the lack of strong diagnostic features. Definitive compositional measurements of Phobos could be obtained using in-situ X-ray, gamma-ray, or neutron spectroscopy or collecting and returning samples to Earth for analysis. We have proposed, in lieu of those methods, to derive Phobos and Deimos compositional data from secondary ion mass spectrometry (SIMS) measurements by calibrating the instrument to elemental abundance measurements made for known samples in the laboratory. We describe the Phobos/Deimos Regolith Ion Sample Mission (PRISM) concept here. PRISM utilizes a high-resolution TOF plasma composition analyzer to make SIMS measurements by observing the sputtered species from various locations of the moons' surfaces. In general, the SIMS technique and ion mass spectrometers complement and expand quadrupole mass spectrometer measurements by collecting ions that have been energized to higher energies, 50-100 eV, and making measurements at very low densities and pressures. Furthermore, because the TOF technique accepts all masses all the time, it obtains continuous measurements and does not require stepping through masses. The instrument would draw less than 10 W and weigh less than 5 kg. The spacecraft, nominally a radiation-hardened 12U CubeSat, would use a low-thrust Solar Electric Propulsion system to send it on a two-year journey to Mars, where it would co-orbit with Deimos and then Phobos at distances as low as 27 km.
- 31 December 2011
- Published by Elsevier in Planetary and Space Science
- Vol. 59 (15) , 1992-2003
Limits to Mercury's magnesium exosphere from MESSENGER second flyby observations
- 31 December 2011
- Published by Elsevier in Planetary and Space Science
- Vol. 59 (15) , 1992-2003
Limits to Mercury's magnesium exosphere from MESSENGER second flyby observations
- 1 January 2008
- Published by Springer Nature
- p. 251-327
Processes that Promote and Deplete the Exosphere of Mercury
- 1 January 2008
- Published by Springer Nature
- p. 251-327
Processes that Promote and Deplete the Exosphere of Mercury
- 30 October 2007
- Published by Springer Nature in Space Science Reviews
- Vol. 132 (2-4) , 433-509
Processes that Promote and Deplete the Exosphere of Mercury
- 30 October 2007
- Published by Springer Nature in Space Science Reviews
- Vol. 132 (2-4) , 433-509
Processes that Promote and Deplete the Exosphere of Mercury
- 17 June 2005
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 32 (12)
Burial rate of Mercury's polar volatile deposits
Delay Doppler images of Mercury's polar regions showing enhanced radar backscatter have been interpreted as evidence for water ice in the polar craters and are consistent with pure water ice covered by about 20 cm of regolith. In this paper we assume that the volatile at the Hermean poles is water ice, and that it was initially deposited at one time in a clean layer. We constrain the time of such an impact by determining the rate of regolith emplacement. The rate of burial of ice deposits in polar craters on Mercury is estimated to be 0.43 cm/Myr. If the ice deposits in Hermean polar craters are both clean and buried by 20 cm of regolith, they must be relatively recently emplaced, <50 Myr ago. The predicted H concentration in the uppermost meter of regolith is calculated as a function of both time since emplacement of the ice and initial thickness of the ice layer. The combination of neutron data and radar data can provide additional insight into the size and age of ice deposits at Mercury.
- 17 June 2005
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 32 (12)
Burial rate of Mercury's polar volatile deposits
Delay Doppler images of Mercury's polar regions showing enhanced radar backscatter have been interpreted as evidence for water ice in the polar craters and are consistent with pure water ice covered by about 20 cm of regolith. In this paper we assume that the volatile at the Hermean poles is water ice, and that it was initially deposited at one time in a clean layer. We constrain the time of such an impact by determining the rate of regolith emplacement. The rate of burial of ice deposits in polar craters on Mercury is estimated to be 0.43 cm/Myr. If the ice deposits in Hermean polar craters are both clean and buried by 20 cm of regolith, they must be relatively recently emplaced, <50 Myr ago. The predicted H concentration in the uppermost meter of regolith is calculated as a function of both time since emplacement of the ice and initial thickness of the ice layer. The combination of neutron data and radar data can provide additional insight into the size and age of ice deposits at Mercury.
- 1 January 2004
- Published by Elsevier in Advances In Space Research
- Vol. 33 (11) , 1899-1904
Space weather at Mercury
- 1 January 2004
- Published by Elsevier in Advances In Space Research
- Vol. 33 (11) , 1899-1904
Space weather at Mercury
- 1 March 2003
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 38 (3) , 383-388
Depletion of sulfur on the surface of asteroids and the moon
Abstract— Data from the X‐ray and γ‐ray spectrometers onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft were used to constrain the chemical and mineralogical composition of asteroid 433 Eros (McCoy et al. 2001). The bulk composition appears to be consistent with that of L to H chondrites (Nittler et al. 2001). However, there appeared to be a marked depletion relative to ordinary chondritic composition in the S/Si ratio (0.014 ± 0.017). We investigate space weathering mechanisms to determine the extent to which sulfur can be preferentially lost from the surface regolith. The two processes considered are impact vaporization by the interplanetary meteoroid population and ion sputtering by the solar wind. Using impact data for Al projectiles onto enstatite, we find that the vaporization rate for troilite (FeS) is nine times as fast as that for the bulk of the regolith. If 20% of the iron is in the form of troilite, then the net vaporization rate, normalized to bulk composition, is 2.8 times faster for sulfur than for iron. Sputtering is equally efficient at removing sulfur as impact vaporization.
- 1 March 2003
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 38 (3) , 383-388
Depletion of sulfur on the surface of asteroids and the moon
Abstract— Data from the X‐ray and γ‐ray spectrometers onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft were used to constrain the chemical and mineralogical composition of asteroid 433 Eros (McCoy et al. 2001). The bulk composition appears to be consistent with that of L to H chondrites (Nittler et al. 2001). However, there appeared to be a marked depletion relative to ordinary chondritic composition in the S/Si ratio (0.014 ± 0.017). We investigate space weathering mechanisms to determine the extent to which sulfur can be preferentially lost from the surface regolith. The two processes considered are impact vaporization by the interplanetary meteoroid population and ion sputtering by the solar wind. Using impact data for Al projectiles onto enstatite, we find that the vaporization rate for troilite (FeS) is nine times as fast as that for the bulk of the regolith. If 20% of the iron is in the form of troilite, then the net vaporization rate, normalized to bulk composition, is 2.8 times faster for sulfur than for iron. Sputtering is equally efficient at removing sulfur as impact vaporization.
- 1 September 2002
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 37 (9) , 1223-1231
Source and maintenance of the argon atmospheres of Mercury and the Moon
Abstract— We propose that argon‐40 measured in the lunar atmosphere and that in Mercury's atmosphere is due to current diffusion into connected pore space within the crust. Higher temperatures at Mercury, along with more rapid loss from the atmosphere, will lead to a similar or smaller column abundance of argon at Mercury than at the Moon, given the same crustal abundance of potassium. Because the noble gas abundance in the mercurian atmosphere represents current effusion, it is a direct measure of the crustal potassium abundance. We assume a fractal distribution of distance to a connected pore space, with the shortest distance increasing with depth. Given this “rock size” distribution, we show that the diffusive flux is not a unique function of temperature. Even though the diffusion coefficient is an exponential function of temperature, the flux to the surface is fairly insensitive to the temperature.
- 1 September 2002
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 37 (9) , 1223-1231
Source and maintenance of the argon atmospheres of Mercury and the Moon
Abstract— We propose that argon‐40 measured in the lunar atmosphere and that in Mercury's atmosphere is due to current diffusion into connected pore space within the crust. Higher temperatures at Mercury, along with more rapid loss from the atmosphere, will lead to a similar or smaller column abundance of argon at Mercury than at the Moon, given the same crustal abundance of potassium. Because the noble gas abundance in the mercurian atmosphere represents current effusion, it is a direct measure of the crustal potassium abundance. We assume a fractal distribution of distance to a connected pore space, with the shortest distance increasing with depth. Given this “rock size” distribution, we show that the diffusive flux is not a unique function of temperature. Even though the diffusion coefficient is an exponential function of temperature, the flux to the surface is fairly insensitive to the temperature.