HKHarald H. Kessler

Harald H. Kessler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Harald H. Kessler has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Automated extraction of plasma samples on the NucliSens easyMAG platform for determination of HCV genotype

    by E. Stelzl, J. Scherlen, G. Burghardt, C. Noppen, H.H. Kessler, E. Viollier, C. Schaefer

  • Automated sample extraction on the NucliSens easyMAG platform for nucleic acid testing of sexually transmitted diseases

    by E. Stelzl, J. Scherlen, G. Burghardt, C. Noppen, H.H. Kessler, E. Viollier, C. Schaefer

  • Detection of Mutations in the Hepatitis B Virus Polymerase Gene

    by Harald H. Kessler, Evelyn Stelzl, Egon Marth, Rudolf E Stauber

    Antiviral treatment of chronic hepatitis B infection aims to reduce viral replication and/or to affect the immune response to the virus and virus-infected cells. The development of reverse transcriptase inhibitors such as lamivudine, which has been shown to be a safe and potent inhibitor of hepatitis B virus (HBV) replication (1)(2), has facilitated major advances in the antiviral treatment of chronic hepatitis B. Today, lamivudine is a first-line therapy for prophylaxis of HBV recurrence in decompensated cirrhotic patients and liver transplant recipients. A major problem with lamivudine treatment is the emergence of drug resistance, which increases with extended duration of therapy (3). Resistant variants have been localized in the reverse transcriptase ( rt ) region of the HBV polymerase gene. Lamivudine-resistant amino acids have been described at positions rt180 (rtL180M) and rt204 (rtM204V/I/S) (4)(5). Methods for the identification of mutations in the HBV polymerase gene include conventional DNA sequencing, restriction fragment length polymorphism analysis, and reverse hybridization (6)(7). In the past, conventional direct DNA sequencing, which is the gold standard method, was the most labor-intensive and time-consuming method (6). Recently, however, a standardized and largely automated HBV polymerase gene-sequencing assay, the TrugeneTM HBV Genotyping Kit, version 1.0 (Bayer/Visible Genetics, Toronto, Ontario), became commercially available. This assay may be suitable for routine diagnostic laboratory work and clinical trial applications. In this preliminary study, we evaluated the performance of the new HBV genotyping assay. Patients undergoing lamivudine treatment were retrospectively investigated for emergence of specific mutations. Serum samples from five HBV DNA-positive (serum load >1000 HBV DNA copies/mL) patients undergoing lamivudine therapy for more than 6 months were analyzed retrospectively. Blood had been collected in 9.0-mL tubes (VacuetteTM; Greiner Bio-one GmbH), and after centrifugation, sera had been aliquoted and stored at −70 °C. Alanine aminotransferase …


  • Fully Automated Detection of Hepatitis C Virus RNA in Serum and Whole-Blood Samples

    by Harald H. Kessler, Alexandra M. K. Clarici, Evelyn Stelzl, Gerhard Mühlbauer, Elisabeth Daghofer, Brigitte I. Santner, Egon Marth, Rudolf E. Stauber

    In this study, we established a fully automated molecular assay for qualitative detection of hepatitis C virus (HCV) in serum and whole-blood samples and compared it with conventional molecular assays, including manual HCV RNA extraction protocols. Whole-blood samples were collected from patients with and without chronic HCV infection in EDTA tubes and nucleic acid stabilization tubes (NASTs). Prior to HCV RNA extraction, the HCV Internal Control (IC), derived from the COBAS AMPLICOR HCV test, version 2.0 (Roche Molecular Diagnostics), was added. The new assay was based on an automated extraction protocol on the MagNA Pure LC instrument (Roche Applied Science), followed by automated reverse transcription, amplification, hybridization, and detection on the Cobas Amplicor analyzer (Roche Molecular Diagnostics). The detection limit of the new assay was found to be similar to those of conventional molecular assays. In clinical samples, 100% agreement between the new assay and conventional methods was observed. The introduced amount of IC was detected in 45 of 45 serum samples, 41 of 45 EDTA tube whole-blood samples, and 43 of 45 NAST whole-blood samples. Retesting led to more frequent IC detection. The fully automated molecular assay was found to be suitable for detection of HCV RNA in different kinds of sample materials. It may be recommended for use in the high-throughput routine molecular diagnostic laboratory.


  • Qualitative detection of Legionella species in bronchoalveolar lavages and induced sputa by automated DNA extraction and real-time polymerase chain reaction

    by Raggam R., Leitner E., MüHlbauer G., Berg J., StöCher M., Grisold A., Marth E., Kessler H.

    Molecular assays for qualitative detection of Legionella spp. in clinical specimens were evaluated. DNA extraction was done either with a fully automated DNA extraction protocol on the MagNA Pure LC System or with manual DNA extraction. Amplification and detection were done by real-time polymerase chain reaction (PCR) on the LightCycler (LC) instrument. Oligonucleotides were derived from the 16S rRNA gene of Legionella spp. The assays included a specially designed DNA fragment as Legionella-specific internal control. For both molecular assays, the detection limit was determined to be 5 CFU per LC PCR run. Sixty-one clinical specimens were tested with the molecular assays. Results were compared to culture. Five samples were found to be positive with the molecular assays. Three of them were positive in culture. No inhibition was found throughout the whole study. In conclusion, the molecular assays described may lead to safe and early diagnosis of Legionnaires' disease. They proved to be suitable for the routine molecular diagnostics laboratory.


  • Open Access

    Evaluation of an Automated Sample Preparation Protocol for Quantitative Detection of Hepatitis C Virus RNA

    by Evelyn Stelzl, Andrea Kormann-Klement, Josef Haas, Elisabeth Daghofer, Brigitte I. Santner, Egon Marth, Harald H. Kessler

    The COBAS AMPLIPREP instrument for automated sample preparation has recently been introduced. In this study, the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test, which includes this new molecular device, was evaluated and compared to the COBAS AMPLICOR HCV MONITOR test, which includes a manual extraction protocol. Interassay and intra-assay variation, precision, and linearity were determined, and a total of 130 clinical specimens were investigated. For determination of interassay variation, coefficients of variation were found to be between 9 and 59% for the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and between 13 and 69% for the COBAS AMPLICOR HCV MONITOR test. For determination of intra-assay variation, coefficients of variation were found to be between 7 and 13% for the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and between 8 and 16% for the COBAS AMPLICOR HCV MONITOR test. When precision of the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test was tested, all results were found to be within ±0.5 log of the expected results. Determination of linearity resulted in a quasilinear curve over 3 logs. When clinical samples were tested with the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and compared with the COBAS AMPLICOR HCV MONITOR test, all results were found within ±0.5 log. In conclusion, the assay, which included the new molecular device, proved to be suitable for the routine molecular laboratory. It was found to be laborsaving and easy to handle.


  • Determination of Human Immunodeficiency Virus Type 1 Subtypes by a Rapid Method Useful for the Routine Diagnostic Laboratory

    by Harald H. Kessler, Doris Deuretzbacher, Evelyn Stelzl, Elisabeth Daghofer, Brigitte I. Santner, Egon Marth

    The existence of human immunodeficiency virus type 1 (HIV-1) subtypes has many important implications for the global evolution of HIV and for the evaluation of pathogenicity, transmissibility, and candidate HIV vaccines. The aim of this study was to establish a rapid method for determination of HIV-1 subtypes useful for a routine diagnostic laboratory and to investigate the distribution of HIV-1 subtypes in Austrian patients. Samples were tested by a subtyping method based on a 1.3-kb sequence of the polymerase gene generated by a commercially available drug resistance assay. The generated sequence was subtyped by means of an HIV sequence database. Results of 74 routine samples revealed subtype B (71.6%) as the predominant subtype, followed by subtype A (13.5%) and subtype C (6.8%). Subtypes E, F, G, and AE (CM240) were also detected. This subtyping method was found to be very easy to handle, rapid, and inexpensive and has proved suitable for high-throughput routine diagnostic laboratories. The specific polymerase gene sequence, however, must be existent.


  • Open Access

    Fully Automated Nucleic Acid Extraction: MagNA Pure LC

    by Harald H Kessler, Gerhard MühLbauer, Evelyn Stelzl, Elisabeth Daghofer, Brigitte I Santner, Egon Marth

    Kinetic PCR analysis by real-time monitoring of DNA amplification was first described 8 years ago ( 1). Recently, the LightCyclerTM instrument (Roche Molecular Biochemicals, Mannheim, Germany), which allows high-speed thermal cycling by use of air instead of thermal blocks and on-line real-time fluorescence monitoring, was introduced ( 2). Several reports have been published with regard to utilization of the LightCycler technology for detection of pathogens ( 3)( 4)( 5)( 6)( 7)( 8)( 9)( 10)( 11).


  • Open Access

    Effects of Storage and Type of Blood Collection Tubes on Hepatitis C Virus Level in Whole Blood Samples

    by Harald H. Kessler, Evelyn Stelzl, Reinhard B. Raggam, Josef Haas, Franz Kirchmeir, Karin Hegenbarth, Elisabeth Daghofer, Brigitte I. Santner, Egon Marth, Rudolf E. Stauber

    In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at “date zero.” In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport.