Hiroyuki Kawano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroyuki Kawano has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Hajime Nakajima
Advanced R&D Center, Mitsubishi Electric Corp., 8-1-1 Tsukaguchihonmachi, Amagasaki, Hyogo 661-8661, Japan
3 shared publicationsTadashi Minobe
Communication System Center, Mitsubishi Electric Corp., 8-1-1 Tsukaguchihonmachi, Amagasaki, Hyogo 661-8661, Japan
3 shared publicationsTaku Matsuzawa
Communication System Center, Mitsubishi Electric Corp., 8-1-1 Tsukaguchihonmachi, Amagasaki, Hyogo 661-8661, Japan
3 shared publications- Tatsuki Okamoto
Kanto Gakuin University
3 shared publications Tatsuya Kunieda
Communication System Center, Mitsubishi Electric Corp., 8-1-1 Tsukaguchihonmachi, Amagasaki, Hyogo 661-8661, Japan
3 shared publicationsHaruhiko Shimoji
Mitsubishi Electric Corp
2 shared publications
Latest Publications
- Open Access
- 5 June 2023
- Published by Springer Nature in Optical Review
- Vol. 30 (3) , 341
The 13th International Conference on Optics-Photonics Design & Fabrication (ODF’22), Sapporo, Japan
- 5 June 2023
- Published by Springer Nature in Optical Review
- Vol. 30 (3) , 341
Open AccessThe 13th International Conference on Optics-Photonics Design & Fabrication (ODF’22), Sapporo, Japan
- 11 August 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (24) , 7010-7016
Apposition compound-eye image scanner by glass plate optics
We propose a design approach for a thin image scanner using the concept of an apposition compound eye comprising many imaging units that take only one pixel image. Although light shielding between adjacent imaging units is always one of the main issues for an artificial compound eye, a simple plane structure using three aperture array layers on two glued glass plates prevents such stray light. Our prototyped scanner, with only 6.8-mm thickness as a packaged module, has 632 microlenses with 200-dpi resolution, resulting in a field of view of 80 mm. The evaluated images show no ghost images.
- 11 August 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (24) , 7010-7016
Apposition compound-eye image scanner by glass plate optics
We propose a design approach for a thin image scanner using the concept of an apposition compound eye comprising many imaging units that take only one pixel image. Although light shielding between adjacent imaging units is always one of the main issues for an artificial compound eye, a simple plane structure using three aperture array layers on two glued glass plates prevents such stray light. Our prototyped scanner, with only 6.8-mm thickness as a packaged module, has 632 microlenses with 200-dpi resolution, resulting in a field of view of 80 mm. The evaluated images show no ghost images.
- 17 July 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (15) , 18010-18019
Practical design for compact image scanner with large depth of field by compound eye system
We designed a new image scanner using the reflective optics of a compound eye system that can easily assemble plural imaging optical units (called imaging cells) and is compact with a large depth of field (DOF). Our image scanner is constructed from 32 reflective imaging cells, each of which takes an image of approximately a 10-mm field of view (FOV) that slightly overlap the adjacent imaging cells. The total image is rebuilt by combining the 32 images in post processing. We studied how to fold the optical path in the imaging cells and simplified the structure, resulting in the following three advances of our previous work: 1) greater compactness (50 × 31 mm2 in the cross section), 2) less variable optical characteristics among the imaging cells, and 3) easy assembly thanks to small number of optical components constructing the imaging cell.
- 17 July 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (15) , 18010-18019
Practical design for compact image scanner with large depth of field by compound eye system
We designed a new image scanner using the reflective optics of a compound eye system that can easily assemble plural imaging optical units (called imaging cells) and is compact with a large depth of field (DOF). Our image scanner is constructed from 32 reflective imaging cells, each of which takes an image of approximately a 10-mm field of view (FOV) that slightly overlap the adjacent imaging cells. The total image is rebuilt by combining the 32 images in post processing. We studied how to fold the optical path in the imaging cells and simplified the structure, resulting in the following three advances of our previous work: 1) greater compactness (50 × 31 mm2 in the cross section), 2) less variable optical characteristics among the imaging cells, and 3) easy assembly thanks to small number of optical components constructing the imaging cell.
- 27 March 2013
- Published by Springer Nature in Optical Review
- Vol. 20 (2) , 254-258
Compact and large depth of field image scanner for auto document feeder with compound eye system
- 27 March 2013
- Published by Springer Nature in Optical Review
- Vol. 20 (2) , 254-258
Compact and large depth of field image scanner for auto document feeder with compound eye system
- Open Access
- 1 June 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (12) , 13532
Compact image scanner with large depth of field by compound eye system.
A compact image scanner is designed by using a compound eye system with plural optical units in which a ray path is folded by reflective optics. The optical units are aligned in two lines and take each image of a separated field of view (FOV), slightly overlapped. Since the optical units are telecentric in the object space and the magnification ratio is constant regardless of the object distance, the separated pieces of a total image are easily combined with each other even in the defocused position. Since the optical axes between adjacent optical units are crossed obliquely, object distance is derived from the parallax at each boundary position and an adequate deblurring process is achieved for the defocused image.
- 1 June 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (12) , 13532
Open AccessCompact image scanner with large depth of field by compound eye system.
A compact image scanner is designed by using a compound eye system with plural optical units in which a ray path is folded by reflective optics. The optical units are aligned in two lines and take each image of a separated field of view (FOV), slightly overlapped. Since the optical units are telecentric in the object space and the magnification ratio is constant regardless of the object distance, the separated pieces of a total image are easily combined with each other even in the defocused position. Since the optical axes between adjacent optical units are crossed obliquely, object distance is derived from the parallax at each boundary position and an adequate deblurring process is achieved for the defocused image.
- 1 March 2008
- Published by Springer Nature in Optical Review
- Vol. 15 (2) , 118-124
Optical testing of star sensor (II): Alignment of star sensor from off-line pictures taken in orbital test
- 1 March 2008
- Published by Springer Nature in Optical Review
- Vol. 15 (2) , 118-124
Optical testing of star sensor (II): Alignment of star sensor from off-line pictures taken in orbital test
- 1 March 2008
- Published by Springer Nature in Optical Review
- Vol. 15 (2) , 110-117
Optical testing of star sensor (I): Defocus spot measuring technique for ground-based test
- 1 March 2008
- Published by Springer Nature in Optical Review
- Vol. 15 (2) , 110-117
Optical testing of star sensor (I): Defocus spot measuring technique for ground-based test
- 1 February 2005
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 12 (01) , 107-113
THE MEAN WORK FUNCTION EFFECTIVE FOR POSITIVE ION EMISSION FROM POLY- AND MONOCRYSTALLINE SURFACES
To clarify the thermionic property of solids, the mean work function effective for positive ion from polycrystalline surfaces (ϕ+) is theoretically studied together with that for electron emission (ϕe). The theoretical values of ϕ+ and ϕe thus evaluated typically with W are in good agreement respectively with those experimental ones accepted today. The thermionic contrast (Δϕ* ≡ ϕ+ – ϕe) is determined to be 0.56–0.57eV for W. For other polycrystalline metals (Nb, Mo, Ta, Re, Ir and Pt), it ranges from about 0.4 to 0.8eV in contrast with monocrystalline ones having Δϕ* = 0. Consequently, the fact of Δϕ* > 0 should be taken into consideration with any polycrystalline surface, and ϕ+ should be adopted whenever we try to analyze those data on positive ion emission due to any of the processes such as thermal stimulation and ion bombardment at heterogeneous surfaces. This article concludes that such typical data on thermal- and secondary-positive ion emissions are analyzed reasonably by adoption of ϕ+ instead of ϕe.
- 1 February 2005
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 12 (01) , 107-113
THE MEAN WORK FUNCTION EFFECTIVE FOR POSITIVE ION EMISSION FROM POLY- AND MONOCRYSTALLINE SURFACES
To clarify the thermionic property of solids, the mean work function effective for positive ion from polycrystalline surfaces (ϕ+) is theoretically studied together with that for electron emission (ϕe). The theoretical values of ϕ+ and ϕe thus evaluated typically with W are in good agreement respectively with those experimental ones accepted today. The thermionic contrast (Δϕ* ≡ ϕ+ – ϕe) is determined to be 0.56–0.57eV for W. For other polycrystalline metals (Nb, Mo, Ta, Re, Ir and Pt), it ranges from about 0.4 to 0.8eV in contrast with monocrystalline ones having Δϕ* = 0. Consequently, the fact of Δϕ* > 0 should be taken into consideration with any polycrystalline surface, and ϕ+ should be adopted whenever we try to analyze those data on positive ion emission due to any of the processes such as thermal stimulation and ion bombardment at heterogeneous surfaces. This article concludes that such typical data on thermal- and secondary-positive ion emissions are analyzed reasonably by adoption of ϕ+ instead of ϕe.
- 23 September 2002
- Published by American Physical Society (APS) in Physical Review A
- Vol. 66 (3) , 031802
Polarization effect in impulsive rotational Raman scattering
We theoretically study rotational Raman coherence excited impulsively in a hydrogen-gas-filled hollow fiber by an fs pump pulse with an arbitrary ellipticity. The results of our simulations based on a rotationally invariant formalism show that the use of an elliptically polarized pulse leads to more efficient phonon excitation than that of a linearly or circularly polarized one. The phonon amplitude dramatically depends both on ellipticity and propagation distance. The passage of a probe pulse in this excited media leads to the generation of high-order Raman sidebands in the pulse.
- 23 September 2002
- Published by American Physical Society (APS) in Physical Review A
- Vol. 66 (3) , 031802
Polarization effect in impulsive rotational Raman scattering
We theoretically study rotational Raman coherence excited impulsively in a hydrogen-gas-filled hollow fiber by an fs pump pulse with an arbitrary ellipticity. The results of our simulations based on a rotationally invariant formalism show that the use of an elliptically polarized pulse leads to more efficient phonon excitation than that of a linearly or circularly polarized one. The phonon amplitude dramatically depends both on ellipticity and propagation distance. The passage of a probe pulse in this excited media leads to the generation of high-order Raman sidebands in the pulse.