YSYuichi Sato

Yuichi Sato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuichi Sato has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhanced recellularization of renal extracellular matrix scaffold under negative pressure

    by Satoshi Hachisuka, Yuichi Sato, Miki Yoshiike, Ryuto Nakazawa, Hideo Sasaki, Tatsuya Chikaraishi

    OA Text is an independent open-access scientific publisher showcases innovative research and ideas aimed at improving health by linking research and practice to the benefit of society.


  • Risk factors associated with inadequate veins for placement of arteriovenous fistulas for hemodialysis

    by Yuichi Sato, Masahito Miyamoto, Shina Sueki, Tsutomu Sakurada, Kenjiro Kimura, Ryuto Nakazawa, Maki Yoshioka, Hideo Sasaki, Satetsu Miyano, Tatsuya Chikaraishi

    An arteriovenous fistula (AVF) between the radial artery and cephalic vein at the wrist is the preferred type of hemodialysis vascular access. However, in the practice of access placement, we are aware that some patients fail to form the standard forearm radial–cephalic AVF, owing to naturally small veins or acquired abnormal lesions of the veins. To identify the risk factors for failure to form the standard AVF, we examined 305 consecutive patients who underwent first-time access surgery at our hospital from January 2006 to December 2010. We compared the patients’ characteristics between those having normal vessels and successfully forming the standard AVF, and those having apparently abnormal vessels and thus forming alternative types of access instead. Histories of major and minor surgery were specifically evaluated, assuming that surgical procedures in the past could potentially damage the superficial veins. We created 207 standard and 98 alternative accesses during the period and found that significantly more patients with alternative accesses (31 %) had undergone major surgery of a variety of specialties, in comparison with those with the standard AVF (15.0 %). Multivariate logistic analysis revealed that a history of major surgery (OR = 2.39, 95 %CI 1.29–4.47, p = 0.006) and female gender (OR = 1.87, 95 %CI 1.10–3.20, p = 0.02) were independent risk factors associated with failure to construct the standard AVF. Our results indicate that previous surgery can damage the superficial veins and cause venous abnormality, which makes construction of the standard AVF difficult. We propose that care should be taken to preserve the superficial veins when patients for whom dialysis therapy is a future possibility undergo surgical procedures, especially invasive ones.


  • Internal filtration in dialyzers with different membrane permeabilities

    by Yuichi Sato, Kenjiro Kimura, Tatsuya Chikaraishi

    Over the last decade, hemodialysis with enhanced internal filtration (IF) has been investigated as an alternative to conventional dialysis. Several factors affect IF, including the geometry and permeability of hollow-fiber dialyzers. Although various studies have been performed, the association between IF and membrane permeability has not been fully examined because of the difficulty in measuring IF. Therefore, in this study, we set up an experimental circuit and attempted to directly measure IF as well as membrane permeability in five dialyzers. In the circuit, we placed two dialyzers of the same type in series, and a special sampling port between them, thereby making it possible to determine IF by measuring the extent to which blood was concentrated between the two dialyzers. We showed that a significant amount of IF occurred in this tandem-dialyzer circuit, ranging from 23.5 to 100 ml/min, which increased linearly with increasing membrane permeability. We also showed that membrane permeability was reduced in the first dialyzer to a greater extent than in the second one after four hours of circulation, suggesting that filtration caused substantial membrane fouling. In this study we practically demonstrated that membrane permeability is highly relevant to the phenomenon of IF.


  • Brachial–brachial autogenous arteriovenous fistula in a dialysis patient with Staphylococcus aureus bacteremia

    by Yuichi Sato, Masahito Miyamoto, Masahiko Yazawa, Ryuto Nakazawa, Hideo Sasaki, Satetsu Miyano, Hisashi Tsutsumi, Kenjiro Kimura, Tatsuya Chikaraishi

    As the number of patients on hemodialysis increases, there will also be an increase in the number of patients with inadequate superficial veins for the creation of an autogenous arteriovenous fistula (AVF). In those patients, medical devices such as vascular prostheses or tunneled-cuffed catheters are necessary to maintain dialysis access. However, these devices are frequently associated with bacterial infection. We recently encountered a dialysis patient who underwent tunneled-cuffed catheter insertion because of the lack of usable superficial veins for autogenous access, and this patient subsequently developed catheter-related Staphylococcus aureus bacteremia with multiple metastatic infections. Despite immediate removal of the catheter, the infection persisted over an extended period, which was a condition precluding the further use of catheters or other prosthetic materials. To handle this situation, we utilized the deep brachial vein to construct an autogenous AVF. After ligating numerous branches, the vein was anastomosed to the brachial artery and then transposed to the subcutaneous space. The newly constructed autogenous AVF, which successfully kept the patient free from foreign materials, greatly contributed to the relief of persistent infection. Although the brachial vein is rarely used for AVF creation, we suggest that it can serve as an option to create an alternative AVF in a patient with inadequate superficial veins.