Lindsey G. Mackay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lindsey G. Mackay has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Chris Mussell
LGC Teddington UK
2 shared publications- Daniel G. Burke
National Measurement Institute Australia (NMIA)
2 shared publications Richard B. Myors
National Measurement Institute, Australia (NMIA)
2 shared publications- Ronda F. Greaves
Victorian Clinical Genetics Services , Murdoch Children’s Research Institute , Melbourne , VIC , Australia
2 shared publications - Ruth Hearn
LGC, Queens Road, Teddington, Middlesex, UK
2 shared publications Agnès Mailloux
Centre National de Référence en Hémobiologie Périnatale, Unit of Biologie, Pole Biology, Hopital Saint Antoine (Public Assistance Hospitals of Paris (AP-HP)), Paris, France
1 shared publication
Latest Publications
- Open Access
- 5 March 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (10) , 1892-1903
Bilirubin measurements in neonates: uniform neonatal treatment can only be achieved by improved standardization
Measurement of total bilirubin (TBil) concentration in serum is the gold standard approach for diagnosing neonatal unconjugated hyperbilirubinemia. It is of utmost importance that the measured TBil concentration is sufficiently accurate to prevent under treatment, unnecessary escalation of care, or overtreatment. However, it is widely recognized that TBil measurements urgently require improvement in neonatal clinical chemistry. External quality assessment (EQA) programs for TBil assess for differences between laboratories and provide supporting evidence of significant differences between various methods, manufacturers and measurement platforms. At the same time, many countries have adopted or only slightly adapted the neonatal hyperbilirubinemia management guidelines from the USA or UK, often without addressing differences in the methodology of TBil measurements. In this report, we provide an overview of the components of bilirubin that are measured by laboratory platforms, the availability of current reference measurement procedures and reference materials, and the role of EQA surveys in this context. Furthermore, the current status of agreement in neonatal bilirubin against clinical decision thresholds is reviewed. We advocate for enhancements in accuracy and comparability of neonatal TBil measurements, propose a path forward to accomplish this, and reflect on the position of the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Working Group Neonatal Bilirubin (WG-NB) in this matter.
- 5 March 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (10) , 1892-1903
Open AccessBilirubin measurements in neonates: uniform neonatal treatment can only be achieved by improved standardization
Measurement of total bilirubin (TBil) concentration in serum is the gold standard approach for diagnosing neonatal unconjugated hyperbilirubinemia. It is of utmost importance that the measured TBil concentration is sufficiently accurate to prevent under treatment, unnecessary escalation of care, or overtreatment. However, it is widely recognized that TBil measurements urgently require improvement in neonatal clinical chemistry. External quality assessment (EQA) programs for TBil assess for differences between laboratories and provide supporting evidence of significant differences between various methods, manufacturers and measurement platforms. At the same time, many countries have adopted or only slightly adapted the neonatal hyperbilirubinemia management guidelines from the USA or UK, often without addressing differences in the methodology of TBil measurements. In this report, we provide an overview of the components of bilirubin that are measured by laboratory platforms, the availability of current reference measurement procedures and reference materials, and the role of EQA surveys in this context. Furthermore, the current status of agreement in neonatal bilirubin against clinical decision thresholds is reviewed. We advocate for enhancements in accuracy and comparability of neonatal TBil measurements, propose a path forward to accomplish this, and reflect on the position of the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Working Group Neonatal Bilirubin (WG-NB) in this matter.
- 1 June 2020
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 66 (6) , 749-750
Further Recommendations on Commutability Assessment
- 1 June 2020
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 66 (6) , 749-750
Further Recommendations on Commutability Assessment
- 7 February 2020
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 58 (10) , 1731-1739
Influence of isotopically labeled internal standards on quantification of serum/plasma 17α-hydroxyprogesterone (17OHP) by liquid chromatography mass spectrometry
Objectives: Our recent survey of 44 mass spectrometry laboratories across 17 countries identified variation in internal standard (IS) choice for the measurement of serum/plasma 17α-hydroxyprogesterone (17OHP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The choice of IS may contribute to inter-method variations. This study evaluated the effect of two common isotopically labeled IS on the quantification of 17OHP by LC-MS/MS. Methods: Three collaborating LC-MS/MS laboratories from Asia, Europe and Australia, who routinely measure serum 17OHP, compared two IS, (1) IsoSciences carbon-13 labeled 17OHP-[2,3,4-13C3], and (2) IsoSciences deuterated 17OHP-[2,2,4,6,6,21,21,21-2H]. This was performed as part of their routine patient runs using their respective laboratory standard operating procedure. Results: The three laboratories measured 99, 89, 95 independent samples, respectively (up to 100 nmol/L) using the 13C- and 2H-labeled IS. The slopes of the Passing-Bablok regression ranged 0.98–1.00 (all 95% confidence interval [CI] estimates included the line of identity), and intercept of 13C- and 2H-labeled IS for 17OHP showed good agreement, and show no clinically significant bias when incorporated into the LC-MS/MS methods employed in the collaborating laboratories.
- 7 February 2020
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 58 (10) , 1731-1739
Influence of isotopically labeled internal standards on quantification of serum/plasma 17α-hydroxyprogesterone (17OHP) by liquid chromatography mass spectrometry
Objectives: Our recent survey of 44 mass spectrometry laboratories across 17 countries identified variation in internal standard (IS) choice for the measurement of serum/plasma 17α-hydroxyprogesterone (17OHP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The choice of IS may contribute to inter-method variations. This study evaluated the effect of two common isotopically labeled IS on the quantification of 17OHP by LC-MS/MS. Methods: Three collaborating LC-MS/MS laboratories from Asia, Europe and Australia, who routinely measure serum 17OHP, compared two IS, (1) IsoSciences carbon-13 labeled 17OHP-[2,3,4-13C3], and (2) IsoSciences deuterated 17OHP-[2,2,4,6,6,21,21,21-2H]. This was performed as part of their routine patient runs using their respective laboratory standard operating procedure. Results: The three laboratories measured 99, 89, 95 independent samples, respectively (up to 100 nmol/L) using the 13C- and 2H-labeled IS. The slopes of the Passing-Bablok regression ranged 0.98–1.00 (all 95% confidence interval [CI] estimates included the line of identity), and intercept of 13C- and 2H-labeled IS for 17OHP showed good agreement, and show no clinically significant bias when incorporated into the LC-MS/MS methods employed in the collaborating laboratories.
- 8 October 2019
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 24 (6) , 407-415
The role of the CCQM OAWG in providing SI traceable calibrators for organic chemical measurements
Metrological traceability for organic chemical measurements is a documented unbroken chain of calibrations with stated uncertainties that ideally link the measurement result for a sample to a primary calibrator in appropriate SI units (e.g., mass fraction). A comprehensive chemical purity determination of the organic calibrator is required to ensure a true assessment of this result. We explore the evolution of chemical purity capabilities across metrology institute members of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology’s Organic Analysis Working Group (OAWG). The OAWG work program has promoted the development of robust measurement capabilities, using indirect “mass balance” determinations via rigorous assessment of impurities and direct determination using quantitative nuclear magnetic resonance spectroscopy methods. A combination of mass balance and qNMR has been shown to provide a best practice approach. Awareness of the importance of the traceability of organic calibrators continues to grow across stakeholder groups, particularly in key areas such as clinical chemistry where activities related to the Joint Committee for Traceability in Laboratory Medicine have raised the profile of traceable calibrators.
- 8 October 2019
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 24 (6) , 407-415
The role of the CCQM OAWG in providing SI traceable calibrators for organic chemical measurements
Metrological traceability for organic chemical measurements is a documented unbroken chain of calibrations with stated uncertainties that ideally link the measurement result for a sample to a primary calibrator in appropriate SI units (e.g., mass fraction). A comprehensive chemical purity determination of the organic calibrator is required to ensure a true assessment of this result. We explore the evolution of chemical purity capabilities across metrology institute members of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology’s Organic Analysis Working Group (OAWG). The OAWG work program has promoted the development of robust measurement capabilities, using indirect “mass balance” determinations via rigorous assessment of impurities and direct determination using quantitative nuclear magnetic resonance spectroscopy methods. A combination of mass balance and qNMR has been shown to provide a best practice approach. Awareness of the importance of the traceability of organic calibrators continues to grow across stakeholder groups, particularly in key areas such as clinical chemistry where activities related to the Joint Committee for Traceability in Laboratory Medicine have raised the profile of traceable calibrators.
- 12 May 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 401 (2) , 483-492
The importance of reference materials in doping-control analysis
Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.
- 12 May 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 401 (2) , 483-492
The importance of reference materials in doping-control analysis
Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.
- 17 February 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 391 (3) , 911-913
Reference standards to underpin the detection of steroid abuse by athletes
- 17 February 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 391 (3) , 911-913
Reference standards to underpin the detection of steroid abuse by athletes
- 20 July 2007
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 12 (9) , 459-464
An international intercomparison for 19-norandrosterone in human urine: the Comité Consultatif pour la Quantité de Matière (CCQM) Pilot Study CCQM-P68
- 20 July 2007
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 12 (9) , 459-464
An international intercomparison for 19-norandrosterone in human urine: the Comité Consultatif pour la Quantité de Matière (CCQM) Pilot Study CCQM-P68
- 12 June 2007
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 12 (9) , 475-482
A high-accuracy method of analysis of 19-norandrosterone in human urine as utilised for the international laboratory intercomparison CCQM-P68
- 12 June 2007
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 12 (9) , 475-482
A high-accuracy method of analysis of 19-norandrosterone in human urine as utilised for the international laboratory intercomparison CCQM-P68
- 15 July 2005
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (10) , 1051-1057
High-accuracy IDMS analysis of trace elements in wheat flour for the provision of reference values to a proficiency testing scheme
Isotope dilution techniques were developed for the analysis of ten trace elements (Cd, Cu, Cr, Hg, Mo, Ni, Pb, Se, Sn and Zn) in a fortified wheat flour candidate sample for a proficiency testing scheme coordinated by NMI. The technique used was exact-matching double isotope dilution mass spectrometry (IDMS) by ICP-MS. A metrological approach was used to examine potential biases and ensure that this potentially primary method of analysis provided appropriate accuracy for the provision of reference values to the proficiency testing scheme. The exact-matching IDMS technique used in this study has been compared with the IDMS methods of other national metrology institutes in the CCQM-K24 and -P29 intercomparisons and the results produced were in very good agreement. Expanded relative uncertainties at the 95% confidence level for the ten elements in the wheat flour varied from 3.1%–14%. The results submitted from the participant laboratories for the proficiency testing scheme generally compared reasonably well with the NMI reference values.
- 15 July 2005
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (10) , 1051-1057
High-accuracy IDMS analysis of trace elements in wheat flour for the provision of reference values to a proficiency testing scheme
Isotope dilution techniques were developed for the analysis of ten trace elements (Cd, Cu, Cr, Hg, Mo, Ni, Pb, Se, Sn and Zn) in a fortified wheat flour candidate sample for a proficiency testing scheme coordinated by NMI. The technique used was exact-matching double isotope dilution mass spectrometry (IDMS) by ICP-MS. A metrological approach was used to examine potential biases and ensure that this potentially primary method of analysis provided appropriate accuracy for the provision of reference values to the proficiency testing scheme. The exact-matching IDMS technique used in this study has been compared with the IDMS methods of other national metrology institutes in the CCQM-K24 and -P29 intercomparisons and the results produced were in very good agreement. Expanded relative uncertainties at the 95% confidence level for the ten elements in the wheat flour varied from 3.1%–14%. The results submitted from the participant laboratories for the proficiency testing scheme generally compared reasonably well with the NMI reference values.
- 7 February 2005
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (3) , 216-219
The high-accuracy analysis of lead in wine by exact-matching isotope dilution mass spectrometry using ICP-MS
An isotope dilution technique was developed for the analysis of Pb in wine using an exact-matching isotope dilution mass spectrometry (IDMS) approach. A metrological approach was used to examine potential biases and ensure that this potentially primary method of analysis provided appropriate accuracy, and an expanded uncertainty at the 95% confidence level of <2% was achieved. The accuracy of this method was demonstrated in an international CCQM intercomparison (CCQM-P12) involving other national metrology institutes. The result submitted for this intercomparison was in very good agreement with results from the majority of other laboratories, all of whom used IDMS.
- 7 February 2005
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (3) , 216-219
The high-accuracy analysis of lead in wine by exact-matching isotope dilution mass spectrometry using ICP-MS
An isotope dilution technique was developed for the analysis of Pb in wine using an exact-matching isotope dilution mass spectrometry (IDMS) approach. A metrological approach was used to examine potential biases and ensure that this potentially primary method of analysis provided appropriate accuracy, and an expanded uncertainty at the 95% confidence level of <2% was achieved. The accuracy of this method was demonstrated in an international CCQM intercomparison (CCQM-P12) involving other national metrology institutes. The result submitted for this intercomparison was in very good agreement with results from the majority of other laboratories, all of whom used IDMS.