Ikuko Toda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ikuko Toda has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Kazuo Tsubota
6 shared publicationsChikako Sakai
Minamiaoyama Eye Clinic
3 shared publicationsYoshiko Hori-Komai
2 shared publicationsAtsushi Yoshida
Minamiaoyama Eye Clinic
1 shared publication- Eiki Goto
Department of Ophthalmology, School of Dental Medicine, Tsurumi University, Yokohama, Japan
1 shared publication Hiroyuki Arai
1 shared publication
Latest Publications
- 1 August 2016
- Published by Wolters Kluwer Health in Cornea
- Vol. 35 (8) , 1069-1072
Efficacy of Hyperopic Photorefractive Keratectomy Simultaneously Performed With Phototherapeutic Keratectomy for Decreasing Hyperopic Shift
Purpose: To investigate the efficacy of hyperopic photorefractive keratectomy (HPRK) that was performed simultaneously with phototherapeutic keratectomy (PTK) with regard to decreasing hyperopic shift. Methods: A total of 63 eyes of 47 consecutive patients with granular corneal dystrophy (GCD) or band-shaped keratopathy (BSK) underwent PTK or PTK + HPRK. PTK alone was performed in 40 eyes (20 GCD and 20 BSK), and PTK + HPRK was performed in 23 eyes (15 GCD and 8 BSK). All patients underwent examinations including uncorrected distance visual acuity, corrected distance visual acuity, refractometry, and keratometry before and at 1, 3, and 6 months after PTK. Medical charts were reviewed retrospectively. Results: Superficial corneal opacity was successfully removed from all eyes, and uneventful reepithelialization was completed within 7 days after PTK or PTK + HPRK. The average uncorrected distance visual acuity was significantly better in the PTK + HPRK group than in the PTK group preoperatively and at 1, 3, and 6 months postoperatively. The corrected distance visual acuities were similar in both groups preoperatively and postoperatively. The hyperopic change in the PTK group was approximately 1.5 diopters, and that in the PTK + HPRK group was almost zero. There were significant differences in the average changes of the spherical equivalent from preoperation between the PTK and PTK + HPRK groups at all postoperative time points. Conclusions: Simultaneous performance of PTK and HPRK can effectively reduce hyperopic shift after PTK and is as safe as PTK alone. It is recommended that HPRK be added to PTK to treat eyes in which hyperopic shift is undesirable.
- 1 August 2016
- Published by Wolters Kluwer Health in Cornea
- Vol. 35 (8) , 1069-1072
Efficacy of Hyperopic Photorefractive Keratectomy Simultaneously Performed With Phototherapeutic Keratectomy for Decreasing Hyperopic Shift
Purpose: To investigate the efficacy of hyperopic photorefractive keratectomy (HPRK) that was performed simultaneously with phototherapeutic keratectomy (PTK) with regard to decreasing hyperopic shift. Methods: A total of 63 eyes of 47 consecutive patients with granular corneal dystrophy (GCD) or band-shaped keratopathy (BSK) underwent PTK or PTK + HPRK. PTK alone was performed in 40 eyes (20 GCD and 20 BSK), and PTK + HPRK was performed in 23 eyes (15 GCD and 8 BSK). All patients underwent examinations including uncorrected distance visual acuity, corrected distance visual acuity, refractometry, and keratometry before and at 1, 3, and 6 months after PTK. Medical charts were reviewed retrospectively. Results: Superficial corneal opacity was successfully removed from all eyes, and uneventful reepithelialization was completed within 7 days after PTK or PTK + HPRK. The average uncorrected distance visual acuity was significantly better in the PTK + HPRK group than in the PTK group preoperatively and at 1, 3, and 6 months postoperatively. The corrected distance visual acuities were similar in both groups preoperatively and postoperatively. The hyperopic change in the PTK group was approximately 1.5 diopters, and that in the PTK + HPRK group was almost zero. There were significant differences in the average changes of the spherical equivalent from preoperation between the PTK and PTK + HPRK groups at all postoperative time points. Conclusions: Simultaneous performance of PTK and HPRK can effectively reduce hyperopic shift after PTK and is as safe as PTK alone. It is recommended that HPRK be added to PTK to treat eyes in which hyperopic shift is undesirable.
- 23 February 2012
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 56 (3) , 208-213
Punctal plugs for treatment of post-LASIK dry eye
To evaluate the efficacy of punctal plugs for patients with post-LASIK dry eye. A prospective study was conducted on 25 eyes of 18 patients who underwent LASIK. All eyes fulfilled the Japanese dry-eye criteria and had not responded to conventional treatment with artificial tears by 1 month postsurgery. They were randomly divided into a plug and a non-plug group. Punctal plugs were inserted into the superior and inferior puncta in the plug group after the 1-month examination. Uncorrected and best corrected visual acuity (UCVA, BCVA), refraction, functional visual acuity (FVA) after 10 s eye opening (FVA 10), surface regularity index (SRI) after 10 s eye opening (SRI 10), corneal sensitivity, Schirmer test, fluorescein staining (FS), tear break-up time (TBUT), and symptoms were compared between the groups 1 and 3 months postsurgery. Changes in these data from 1 to 3 months were also compared between the groups. The values in SRI 10, FS, and TBUT were significantly better in the plug group at 3 months. Changes in the values of UCVA, FVA 10, FS, TBUT, and symptoms between 1 and 3 months improved significantly in the plug group compared with the non-plug group. Our results suggest that punctal occlusion for both puncta is effective for patients with post-LASIK dry eye that cannot be controlled by artificial tears alone. Punctal plugs can improve not only the symptoms and tear function, but also the quality of vision, for example FVA.
- 23 February 2012
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 56 (3) , 208-213
Punctal plugs for treatment of post-LASIK dry eye
To evaluate the efficacy of punctal plugs for patients with post-LASIK dry eye. A prospective study was conducted on 25 eyes of 18 patients who underwent LASIK. All eyes fulfilled the Japanese dry-eye criteria and had not responded to conventional treatment with artificial tears by 1 month postsurgery. They were randomly divided into a plug and a non-plug group. Punctal plugs were inserted into the superior and inferior puncta in the plug group after the 1-month examination. Uncorrected and best corrected visual acuity (UCVA, BCVA), refraction, functional visual acuity (FVA) after 10 s eye opening (FVA 10), surface regularity index (SRI) after 10 s eye opening (SRI 10), corneal sensitivity, Schirmer test, fluorescein staining (FS), tear break-up time (TBUT), and symptoms were compared between the groups 1 and 3 months postsurgery. Changes in these data from 1 to 3 months were also compared between the groups. The values in SRI 10, FS, and TBUT were significantly better in the plug group at 3 months. Changes in the values of UCVA, FVA 10, FS, TBUT, and symptoms between 1 and 3 months improved significantly in the plug group compared with the non-plug group. Our results suggest that punctal occlusion for both puncta is effective for patients with post-LASIK dry eye that cannot be controlled by artificial tears alone. Punctal plugs can improve not only the symptoms and tear function, but also the quality of vision, for example FVA.
- 1 January 2012
- Published by Asia Pacific Academy of Ophthalmology in Asia-Pacific Journal of Ophthalmology
- Vol. 1 (2) , 68
Author Reply
- 1 January 2012
- Published by Asia Pacific Academy of Ophthalmology in Asia-Pacific Journal of Ophthalmology
- Vol. 1 (2) , 68
Author Reply
- 31 March 2011
- Published by Elsevier in Ophthalmology
- Vol. 118 (3) , 605-605.e2
Phakic Intraocular Lens for Keratoconus
- 31 March 2011
- Published by Elsevier in Ophthalmology
- Vol. 118 (3) , 605-605.e2
Phakic Intraocular Lens for Keratoconus
- 1 May 2008
- Vol. 112 (5) , 465-71
[Traumatic flap dislocation after laser in situ keratomileusis].
To report our experience in treating cases of flap dislocation caused by trauma after laser in situ keratomileusis (LASIK). We did a retrospective review of the case records of 16,319 patients (31,655 eyes) who underwent LASIK in Minamiaoyama Eye Clinic. Ten eyes of 9 patients were treated for flap dislocation. Conditions of the trauma occurrence, main findings of the eyes, treatments and clinical results are described. Dislocation occurred during a period of 5 days to 4 years after LASIK. Accidents happened when working, when playing with children or pets, or when fighting. The main findings were folds or microstriae, diffuse lamellar keratitis (DLK), and epithelial ingrowth, including partial splitting of the flap (1 eye) and only a crack in the epithelium of the flap edge (1 eye). Seven flaps were lifted, irrigated and repositioned, and observed after fitting the patients with soft contact lenses. Three flaps were treated with eye drops of hyaluronic acid only, or with systemic steroids, topical steroids, and antibiotics. Uncorrected visual acuity recovered to more than 1.0 in 7 eyes, and best corrected visual acuity (BCVA) was more than 1.0 in all eyes. However, 3 eyes lost one line and 1 eye lost two lines of BCVA. Many cases of flap dislocation showed recovery of good visual acuity with adequate and prompt treatment. However, it is possible to leave irregular astigmatism untreated which has a bad effect on visual acuity, depending on the affected part and the seriousness of the injury. The connection between patient and clinic is important for proper and prompt treatment.
- 1 May 2008
- Vol. 112 (5) , 465-71
[Traumatic flap dislocation after laser in situ keratomileusis].
To report our experience in treating cases of flap dislocation caused by trauma after laser in situ keratomileusis (LASIK). We did a retrospective review of the case records of 16,319 patients (31,655 eyes) who underwent LASIK in Minamiaoyama Eye Clinic. Ten eyes of 9 patients were treated for flap dislocation. Conditions of the trauma occurrence, main findings of the eyes, treatments and clinical results are described. Dislocation occurred during a period of 5 days to 4 years after LASIK. Accidents happened when working, when playing with children or pets, or when fighting. The main findings were folds or microstriae, diffuse lamellar keratitis (DLK), and epithelial ingrowth, including partial splitting of the flap (1 eye) and only a crack in the epithelium of the flap edge (1 eye). Seven flaps were lifted, irrigated and repositioned, and observed after fitting the patients with soft contact lenses. Three flaps were treated with eye drops of hyaluronic acid only, or with systemic steroids, topical steroids, and antibiotics. Uncorrected visual acuity recovered to more than 1.0 in 7 eyes, and best corrected visual acuity (BCVA) was more than 1.0 in all eyes. However, 3 eyes lost one line and 1 eye lost two lines of BCVA. Many cases of flap dislocation showed recovery of good visual acuity with adequate and prompt treatment. However, it is possible to leave irregular astigmatism untreated which has a bad effect on visual acuity, depending on the affected part and the seriousness of the injury. The connection between patient and clinic is important for proper and prompt treatment.
- 1 January 2005
- Published by Elsevier in The Ocular Surface
- Vol. 3, S120
Efficacy of Disposable Eyelid Warming Device for the Treatment of Post-Lasik Dry Eye
- 1 January 2005
- Published by Elsevier in The Ocular Surface
- Vol. 3, S120
Efficacy of Disposable Eyelid Warming Device for the Treatment of Post-Lasik Dry Eye