Laura C. Fitton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Laura C. Fitton has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Aimée Little
University of York
1 shared publication J. F. Shi
Department of Engineering, University of Hull, UK
1 shared publication- Jacob Lyons
University of York
1 shared publication - Jia Liu
Department of Computer Science, University of Hull, Hull, UK
1 shared publication - Junfen Shi
Department of Engineering, University of Hull, Hull, UK
1 shared publication - Lasse van Den Dikkenberg
Faculty of Archaeology Leiden University Leiden The Netherlands
1 shared publication
Latest Publications
- Open Access
- 15 March 2025
- Published by Edinburgh University Library in Journal of Lithic Studies
- Vol. 12 (1) , 30 p.
Skaill knives from the Ness of Brodgar: An experimental pilot study exploring their potential for functional and technological analysis
This paper presents the results of a pilot study exploring the biographies of Skaill knives from the Neolithic site of Ness of Brodgar (UK). Skaill knives are large sandstone flakes made from beach cobbles. We present an experimental study in which we replicated and used Skaill knives. A selection of ten archaeological Skaill knives was subjected to a detailed technological and functional analysis. Functional analysis of the experimental and archaeological tools was conducted both with a low power stereomicroscope and a high-power metallographic microscope. 3D models of the archaeological Skaill knives were made to better understand and visualise technological features and use-wear traces. These observations allowed us to link the flaked cobbles, frequently found in Neolithic Orkney, to the chaîne opératoire of Skaill knives. Regarding the production process, we were able to demonstrate that it seems likely that at least some of the Skaill knives were produced using bipolar percussion. Contrary to what was hitherto assumed, it seems unlikely that the Skaill knives were produced by dashing the stones on rocks, as the archaeological evidence points towards a more controlled method of production. The experimental work generally resulted in little to no polish development, but macroscopic features such as edge rounding and edge removals frequently occurred. The archaeological Skaill knives displayed diverse use-wear traces. Certain zones displayed heavy unifacial rounding, which most likely resulted from a scraping motion on an abrasive material. Other zones displayed extensive edge removals, which could either be linked to butchering activities or to contact with harder materials. Morphologically, these traces appeared to be linked to different zones on the Skaill knives. The extensively rounded zones more commonly appeared on the short sides of Skaill knives, when cobbles were split lengthwise. The edge removals tended to occur on the long sides of Skaill knives which were split along the width of the cobble. Although specific contact materials could not be assigned, the study revealed interesting insights into the biographies of these tools.
- 15 March 2025
- Published by Edinburgh University Library in Journal of Lithic Studies
- Vol. 12 (1) , 30 p.
Open AccessSkaill knives from the Ness of Brodgar: An experimental pilot study exploring their potential for functional and technological analysis
This paper presents the results of a pilot study exploring the biographies of Skaill knives from the Neolithic site of Ness of Brodgar (UK). Skaill knives are large sandstone flakes made from beach cobbles. We present an experimental study in which we replicated and used Skaill knives. A selection of ten archaeological Skaill knives was subjected to a detailed technological and functional analysis. Functional analysis of the experimental and archaeological tools was conducted both with a low power stereomicroscope and a high-power metallographic microscope. 3D models of the archaeological Skaill knives were made to better understand and visualise technological features and use-wear traces. These observations allowed us to link the flaked cobbles, frequently found in Neolithic Orkney, to the chaîne opératoire of Skaill knives. Regarding the production process, we were able to demonstrate that it seems likely that at least some of the Skaill knives were produced using bipolar percussion. Contrary to what was hitherto assumed, it seems unlikely that the Skaill knives were produced by dashing the stones on rocks, as the archaeological evidence points towards a more controlled method of production. The experimental work generally resulted in little to no polish development, but macroscopic features such as edge rounding and edge removals frequently occurred. The archaeological Skaill knives displayed diverse use-wear traces. Certain zones displayed heavy unifacial rounding, which most likely resulted from a scraping motion on an abrasive material. Other zones displayed extensive edge removals, which could either be linked to butchering activities or to contact with harder materials. Morphologically, these traces appeared to be linked to different zones on the Skaill knives. The extensively rounded zones more commonly appeared on the short sides of Skaill knives, when cobbles were split lengthwise. The edge removals tended to occur on the long sides of Skaill knives which were split along the width of the cobble. Although specific contact materials could not be assigned, the study revealed interesting insights into the biographies of these tools.
- Open Access
- 13 June 2012
- Published by Wiley in Journal of Anatomy
- Vol. 221 (1) , 55-68
Masticatory loadings and cranial deformation in Macaca fascicularis: a finite element analysis sensitivity study
Biomechanical analyses are commonly conducted to investigate how craniofacial form relates to function, particularly in relation to dietary adaptations. However, in the absence of corresponding muscle activation patterns, incomplete muscle data recorded experimentally for different individuals during different feeding tasks are frequently substituted. This study uses finite element analysis (FEA) to examine the sensitivity of the mechanical response of a Macaca fascicularis cranium to varying muscle activation patterns predicted via multibody dynamic analysis. Relative to the effects of varying bite location, the consequences of simulated variations in muscle activation patterns and of the inclusion/exclusion of whole muscle groups were investigated. The resulting cranial deformations were compared using two approaches; strain maps and geometric morphometric analyses. The results indicate that, with bite force magnitude controlled, the variations among the mechanical responses of the cranium to bite location far outweigh those observed as a consequence of varying muscle activations. However, zygomatic deformation was an exception, with the activation levels of superficial masseter being most influential in this regard. The anterior portion of temporalis deforms the cranial vault, but the remaining muscles have less profound effects. This study for the first time systematically quantifies the sensitivity of an FEA model of a primate skull to widely varying masticatory muscle activations and finds that, with the exception of the zygomatic arch, reasonable variants of muscle loading for a second molar bite have considerably less effect on cranial deformation and the resulting strain map than does varying molar bite point. The implication is that FEA models of biting crania will generally produce acceptable estimates of deformation under load as long as muscle activations and forces are reasonably approximated. In any one FEA study, the biological significance of the error in applied muscle forces is best judged against the magnitude of the effect that is being investigated.
- 13 June 2012
- Published by Wiley in Journal of Anatomy
- Vol. 221 (1) , 55-68
Open AccessMasticatory loadings and cranial deformation in Macaca fascicularis: a finite element analysis sensitivity study
Biomechanical analyses are commonly conducted to investigate how craniofacial form relates to function, particularly in relation to dietary adaptations. However, in the absence of corresponding muscle activation patterns, incomplete muscle data recorded experimentally for different individuals during different feeding tasks are frequently substituted. This study uses finite element analysis (FEA) to examine the sensitivity of the mechanical response of a Macaca fascicularis cranium to varying muscle activation patterns predicted via multibody dynamic analysis. Relative to the effects of varying bite location, the consequences of simulated variations in muscle activation patterns and of the inclusion/exclusion of whole muscle groups were investigated. The resulting cranial deformations were compared using two approaches; strain maps and geometric morphometric analyses. The results indicate that, with bite force magnitude controlled, the variations among the mechanical responses of the cranium to bite location far outweigh those observed as a consequence of varying muscle activations. However, zygomatic deformation was an exception, with the activation levels of superficial masseter being most influential in this regard. The anterior portion of temporalis deforms the cranial vault, but the remaining muscles have less profound effects. This study for the first time systematically quantifies the sensitivity of an FEA model of a primate skull to widely varying masticatory muscle activations and finds that, with the exception of the zygomatic arch, reasonable variants of muscle loading for a second molar bite have considerably less effect on cranial deformation and the resulting strain map than does varying molar bite point. The implication is that FEA models of biting crania will generally produce acceptable estimates of deformation under load as long as muscle activations and forces are reasonably approximated. In any one FEA study, the biological significance of the error in applied muscle forces is best judged against the magnitude of the effect that is being investigated.
- 10 February 2011
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 11 (1-2) , 35-47
The application of muscle wrapping to voxel-based finite element models of skeletal structures
Finite elements analysis (FEA) is now used routinely to interpret skeletal form in terms of function in both medical and biological applications. To produce accurate predictions from FEA models, it is essential that the loading due to muscle action is applied in a physiologically reasonable manner. However, it is common for muscle forces to be represented as simple force vectors applied at a few nodes on the model’s surface. It is certainly rare for any wrapping of the muscles to be considered, and yet wrapping not only alters the directions of muscle forces but also applies an additional compressive load from the muscle belly directly to the underlying bone surface. This paper presents a method of applying muscle wrapping to high-resolution voxel-based finite element (FE) models. Such voxel-based models have a number of advantages over standard (geometry-based) FE models, but the increased resolution with which the load can be distributed over a model’s surface is particularly advantageous, reflecting more closely how muscle fibre attachments are distributed. In this paper, the development, application and validation of a muscle wrapping method is illustrated using a simple cylinder. The algorithm: (1) calculates the shortest path over the surface of a bone given the points of origin and ultimate attachment of the muscle fibres; (2) fits a Non-Uniform Rational B-Spline (NURBS) curve from the shortest path and calculates its tangent, normal vectors and curvatures so that normal and tangential components of the muscle force can be calculated and applied along the fibre; and (3) automatically distributes the loads between adjacent fibres to cover the bone surface with a fully distributed muscle force, as is observed in vivo. Finally, we present a practical application of this approach to the wrapping of the temporalis muscle around the cranium of a macaque skull.
- 10 February 2011
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 11 (1-2) , 35-47
The application of muscle wrapping to voxel-based finite element models of skeletal structures
Finite elements analysis (FEA) is now used routinely to interpret skeletal form in terms of function in both medical and biological applications. To produce accurate predictions from FEA models, it is essential that the loading due to muscle action is applied in a physiologically reasonable manner. However, it is common for muscle forces to be represented as simple force vectors applied at a few nodes on the model’s surface. It is certainly rare for any wrapping of the muscles to be considered, and yet wrapping not only alters the directions of muscle forces but also applies an additional compressive load from the muscle belly directly to the underlying bone surface. This paper presents a method of applying muscle wrapping to high-resolution voxel-based finite element (FE) models. Such voxel-based models have a number of advantages over standard (geometry-based) FE models, but the increased resolution with which the load can be distributed over a model’s surface is particularly advantageous, reflecting more closely how muscle fibre attachments are distributed. In this paper, the development, application and validation of a muscle wrapping method is illustrated using a simple cylinder. The algorithm: (1) calculates the shortest path over the surface of a bone given the points of origin and ultimate attachment of the muscle fibres; (2) fits a Non-Uniform Rational B-Spline (NURBS) curve from the shortest path and calculates its tangent, normal vectors and curvatures so that normal and tangential components of the muscle force can be calculated and applied along the fibre; and (3) automatically distributes the loads between adjacent fibres to cover the bone surface with a fully distributed muscle force, as is observed in vivo. Finally, we present a practical application of this approach to the wrapping of the temporalis muscle around the cranium of a macaque skull.