Niels C. Munksgaard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Niels C. Munksgaard has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Michael I. Bird
College of Science and Engineering, James Cook University, Cairns 4878, Queensland, Australia
5 shared publications - Adrian M. Bass
School of Geographical and Earth Sciences University of Glasgow Glasgow UK
4 shared publications - Alexander W. Cheesman
College of Science and Engineering James Cook University Cairns Qld 4878 Australia
2 shared publications Chris M. Wurster
School of Earth and Environmental Sciences and Centre for Tropical Environmental and Sustainability Science James Cook University Cairns Australia
2 shared publications- Christopher M. Wurster
ARC Centre of Excellence for Indigenous and Environmental Histories and Futures, College of Science and Engineering James Cook University Cairns QLD Australia
2 shared publications Karen S. Gibb
Research Institute for the Environment and Livelihoods, Charles Darwin University, Darwin, NT 0909, Australia
2 shared publications
Latest Publications
- 20 March 2019
- Published by Elsevier in Journal of Water Process Engineering
- Vol. 29, 100802
Wastewater nitrogen budgets can be resolved by complementary functional gene and physicochemical methods
- 20 March 2019
- Published by Elsevier in Journal of Water Process Engineering
- Vol. 29, 100802
Wastewater nitrogen budgets can be resolved by complementary functional gene and physicochemical methods
- 1 October 2017
- Published by Elsevier in Marine Pollution Bulletin
- Vol. 123 (1-2) , 47-56
Cadmium uptake and zinc-cadmium antagonism in Australian tropical rock oysters: Potential solutions for oyster aquaculture enterprises
- 1 October 2017
- Published by Elsevier in Marine Pollution Bulletin
- Vol. 123 (1-2) , 47-56
Cadmium uptake and zinc-cadmium antagonism in Australian tropical rock oysters: Potential solutions for oyster aquaculture enterprises
- 24 December 2016
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 189 (1) , 36
Enrichment of 15N/14N in wastewater-derived effluent varies with operational performance of treatment systems: implications for isotope monitoring in receiving environments
Stable nitrogen isotope ratios are routinely used to trace the dispersion and assimilation of wastewater-derived N in receiving environments, but few isotope studies have investigated wastewater treatment plants and ponds themselves. An improved understanding of N isotope compositions in effluent will help assess treatment plant processes and performance and will help trace sources of excess nutrients in receiving environments. Here, we assess N budgets and treatment processes in seven wastewater treatment plants and wastewater stabilisation ponds in northern Australia based on concentrations and isotope ratios of N in effluent. We show that δ15N values in effluent are linked to treatment type, effectiveness of conversion of ammonia and levels of gaseous N emissions. These relationships suggest that N isotope monitoring of wastewater treatment plants and ponds can provide an integrated assessment of treatment performance and gaseous N emissions on a pond- or plant-wide scale that is not readily available through other methods. Our findings further imply that monitoring N isotope ratios in receiving environments cannot be assumed to be universally effective as their sensitivity to uptake of wastewater-derived N will vary with the characteristics of individual treatment systems. Paradoxically, N isotope monitoring is less effective where treatment systems are functioning poorly and where monitoring needs are the greatest.
- 24 December 2016
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 189 (1) , 36
Enrichment of 15N/14N in wastewater-derived effluent varies with operational performance of treatment systems: implications for isotope monitoring in receiving environments
Stable nitrogen isotope ratios are routinely used to trace the dispersion and assimilation of wastewater-derived N in receiving environments, but few isotope studies have investigated wastewater treatment plants and ponds themselves. An improved understanding of N isotope compositions in effluent will help assess treatment plant processes and performance and will help trace sources of excess nutrients in receiving environments. Here, we assess N budgets and treatment processes in seven wastewater treatment plants and wastewater stabilisation ponds in northern Australia based on concentrations and isotope ratios of N in effluent. We show that δ15N values in effluent are linked to treatment type, effectiveness of conversion of ammonia and levels of gaseous N emissions. These relationships suggest that N isotope monitoring of wastewater treatment plants and ponds can provide an integrated assessment of treatment performance and gaseous N emissions on a pond- or plant-wide scale that is not readily available through other methods. Our findings further imply that monitoring N isotope ratios in receiving environments cannot be assumed to be universally effective as their sensitivity to uptake of wastewater-derived N will vary with the characteristics of individual treatment systems. Paradoxically, N isotope monitoring is less effective where treatment systems are functioning poorly and where monitoring needs are the greatest.
- 31 October 2016
- Published by Springer Nature in Oecologia
- Vol. 183 (1) , 31-43
Identifying drivers of leaf water and cellulose stable isotope enrichment in Eucalyptus in northern Australia
Several previous studies have investigated the use of the stable hydrogen and oxygen isotope compositions in plant materials as indicators of palaeoclimate. However, accurate interpretation relies on a detailed understanding of both physiological and environmental drivers of the variations in isotopic enrichments that occur in leaf water and associated organic compounds. To progress this aim we measured δ18O and δ2H values in eucalypt leaf and stem water and δ18O values in leaf cellulose, along with the isotopic compositions of water vapour, across a north-eastern Australian aridity gradient. Here we compare observed leaf water enrichment, along with previously published enrichment data from a similar north Australian transect, to Craig–Gordon-modelled predictions of leaf water isotopic enrichment. Our investigation of model parameters shows that observed 18O enrichment across the aridity gradients is dominated by the relationship between atmospheric and internal leaf water vapour pressure while 2H enrichment is driven mainly by variation in the water vapour—source water isotopic disequilibrium. During exceptionally dry and hot conditions (RH < 21%, T > 37 °C) we observed strong deviations from Craig–Gordon predicted isotope enrichments caused by partial stomatal closure. The atmospheric–leaf vapour pressure relationship is also a strong predictor of the observed leaf cellulose δ18O values across one aridity gradient. Our finding supports a wider applicability of leaf cellulose δ18O composition as a climate proxy for atmospheric humidity conditions during the leaf growing season than previously documented.
- 31 October 2016
- Published by Springer Nature in Oecologia
- Vol. 183 (1) , 31-43
Identifying drivers of leaf water and cellulose stable isotope enrichment in Eucalyptus in northern Australia
Several previous studies have investigated the use of the stable hydrogen and oxygen isotope compositions in plant materials as indicators of palaeoclimate. However, accurate interpretation relies on a detailed understanding of both physiological and environmental drivers of the variations in isotopic enrichments that occur in leaf water and associated organic compounds. To progress this aim we measured δ18O and δ2H values in eucalypt leaf and stem water and δ18O values in leaf cellulose, along with the isotopic compositions of water vapour, across a north-eastern Australian aridity gradient. Here we compare observed leaf water enrichment, along with previously published enrichment data from a similar north Australian transect, to Craig–Gordon-modelled predictions of leaf water isotopic enrichment. Our investigation of model parameters shows that observed 18O enrichment across the aridity gradients is dominated by the relationship between atmospheric and internal leaf water vapour pressure while 2H enrichment is driven mainly by variation in the water vapour—source water isotopic disequilibrium. During exceptionally dry and hot conditions (RH < 21%, T > 37 °C) we observed strong deviations from Craig–Gordon predicted isotope enrichments caused by partial stomatal closure. The atmospheric–leaf vapour pressure relationship is also a strong predictor of the observed leaf cellulose δ18O values across one aridity gradient. Our finding supports a wider applicability of leaf cellulose δ18O composition as a climate proxy for atmospheric humidity conditions during the leaf growing season than previously documented.
- Open Access
- 5 March 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (3) , e0119728
Stable Isotope Anatomy of Tropical Cyclone Ita, North-Eastern Australia, April 2014
The isotope signatures registered in speleothems during tropical cyclones (TC) provides information about the frequency and intensity of past TCs but the precise relationship between isotopic composition and the meteorology of TCs remain uncertain. Here we present continuous δ18O and δ2H data in rainfall and water vapour, as well as in discrete rainfall samples, during the passage of TC Ita and relate the evolution in isotopic compositions to local and synoptic scale meteorological observations. High-resolution data revealed a close relationship between isotopic compositions and cyclonic features such as spiral rainbands, periods of stratiform rainfall and the arrival of subtropical and tropical air masses with changing oceanic and continental moisture sources. The isotopic compositions in discrete rainfall samples were remarkably constant along the ~450 km overland path of the cyclone when taking into account the direction and distance to the eye of the cyclone at each sampling time. Near simultaneous variations in δ18O and δ2H values in rainfall and vapour and a near-equilibrium rainfall-vapour isotope fractionation indicates strong isotopic exchange between rainfall and surface inflow of vapour during the approach of the cyclone. In contrast, after the passage of spiral rainbands close to the eye of the cyclone, different moisture sources for rainfall and vapour are reflected in diverging d-excess values. High-resolution isotope studies of modern TCs refine the interpretation of stable isotope signatures found in speleothems and other paleo archives and should aim to further investigate the influence of cyclone intensity and longevity on the isotopic composition of associated rainfall.
- 5 March 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (3) , e0119728
Open AccessStable Isotope Anatomy of Tropical Cyclone Ita, North-Eastern Australia, April 2014
The isotope signatures registered in speleothems during tropical cyclones (TC) provides information about the frequency and intensity of past TCs but the precise relationship between isotopic composition and the meteorology of TCs remain uncertain. Here we present continuous δ18O and δ2H data in rainfall and water vapour, as well as in discrete rainfall samples, during the passage of TC Ita and relate the evolution in isotopic compositions to local and synoptic scale meteorological observations. High-resolution data revealed a close relationship between isotopic compositions and cyclonic features such as spiral rainbands, periods of stratiform rainfall and the arrival of subtropical and tropical air masses with changing oceanic and continental moisture sources. The isotopic compositions in discrete rainfall samples were remarkably constant along the ~450 km overland path of the cyclone when taking into account the direction and distance to the eye of the cyclone at each sampling time. Near simultaneous variations in δ18O and δ2H values in rainfall and vapour and a near-equilibrium rainfall-vapour isotope fractionation indicates strong isotopic exchange between rainfall and surface inflow of vapour during the approach of the cyclone. In contrast, after the passage of spiral rainbands close to the eye of the cyclone, different moisture sources for rainfall and vapour are reflected in diverging d-excess values. High-resolution isotope studies of modern TCs refine the interpretation of stable isotope signatures found in speleothems and other paleo archives and should aim to further investigate the influence of cyclone intensity and longevity on the isotopic composition of associated rainfall.
- 1 September 2014
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 28 (20) , 2151-2161
Microwave extraction–isotope ratio infrared spectroscopy (ME‐IRIS): a novel technique for rapid extraction and in‐line analysis of δ 18 O and δ 2 H values of water in plants, soils and insects
RATIONALE: Traditionally, stable isotope analysis of plant and soil water has been a technically challenging, labour‐intensive and time‐consuming process. Here we describe a rapid single‐step technique which combines Microwave Extraction with Isotope Ratio Infrared Spectroscopy (ME‐IRIS). METHODS: Plant, soil and insect water is extracted into a dry air stream by microwave irradiation within a sealed vessel. The water vapor thus produced is carried to a cooled condensation chamber, which controls the water vapor concentration and flow rate to the spectrometer. Integration of the isotope signals over the whole analytical cycle provides quantitative δ 18 O and δ 2 H values for the initial liquid water contained in the sample. Calibration is carried out by the analysis of water standards using the same apparatus. Analysis of leaf and soil water by cryogenic vacuum distillation and IRMS was used to validate the ME‐IRIS data. RESULTS: Comparison with data obtained by cryogenic distillation and IRMS shows that the new technique provides accurate water isotope data for leaves from a range of field‐grown tropical plant species. However, two exotic nursery plants were found to suffer from spectral interferences from co‐extracted organic compounds. The precision for extracted leaf, stem, soil and insect water was typically better than ±0.3 ‰ for δ 18 O and ±2 ‰ for δ 2 H values, and better than ±0.1 ‰ for δ 18 O and ±1 ‰ for δ 2 H values when analyzing water standards. The effects of sample size, microwave power and duration and sample‐to‐sample memory on isotope values were assessed. CONCLUSIONS: ME‐IRIS provides rapid and low‐cost extraction and analysis of δ 18 O and δ 2 H values in plant, soil and insect water (≈10–15 min for samples yielding ≈ 0.3 mL of water). The technique can accommodate whole leaves of many plant species. Copyright © 2014 John Wiley & Sons, Ltd.
- 1 September 2014
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 28 (20) , 2151-2161
Microwave extraction–isotope ratio infrared spectroscopy (ME‐IRIS): a novel technique for rapid extraction and in‐line analysis of δ 18 O and δ 2 H values of water in plants, soils and insects
RATIONALE: Traditionally, stable isotope analysis of plant and soil water has been a technically challenging, labour‐intensive and time‐consuming process. Here we describe a rapid single‐step technique which combines Microwave Extraction with Isotope Ratio Infrared Spectroscopy (ME‐IRIS). METHODS: Plant, soil and insect water is extracted into a dry air stream by microwave irradiation within a sealed vessel. The water vapor thus produced is carried to a cooled condensation chamber, which controls the water vapor concentration and flow rate to the spectrometer. Integration of the isotope signals over the whole analytical cycle provides quantitative δ 18 O and δ 2 H values for the initial liquid water contained in the sample. Calibration is carried out by the analysis of water standards using the same apparatus. Analysis of leaf and soil water by cryogenic vacuum distillation and IRMS was used to validate the ME‐IRIS data. RESULTS: Comparison with data obtained by cryogenic distillation and IRMS shows that the new technique provides accurate water isotope data for leaves from a range of field‐grown tropical plant species. However, two exotic nursery plants were found to suffer from spectral interferences from co‐extracted organic compounds. The precision for extracted leaf, stem, soil and insect water was typically better than ±0.3 ‰ for δ 18 O and ±2 ‰ for δ 2 H values, and better than ±0.1 ‰ for δ 18 O and ±1 ‰ for δ 2 H values when analyzing water standards. The effects of sample size, microwave power and duration and sample‐to‐sample memory on isotope values were assessed. CONCLUSIONS: ME‐IRIS provides rapid and low‐cost extraction and analysis of δ 18 O and δ 2 H values in plant, soil and insect water (≈10–15 min for samples yielding ≈ 0.3 mL of water). The technique can accommodate whole leaves of many plant species. Copyright © 2014 John Wiley & Sons, Ltd.
- 16 January 2013
- Published by Taylor & Francis in Isotopes in Environmental and Health Studies
- Vol. 49 (2) , 232-242
Field-based cavity ring-down spectrometry of δ13C in soil-respired CO2
Measurement of soil-respired CO2 at high temporal resolution and sample density is necessary to accurately identify sources and quantify effluxes of soil-respired CO2. A portable sampling device for the analysis of δ13C values in the field is described herein. CO2 accumulated in a soil chamber was batch sampled sequentially in four gas bags and analysed by Wavelength-Scanned Cavity Ring-down Spectrometry (WS-CRDS). A Keeling plot (1/[CO2] versus δ13C) was used to derive δ13C values of soil-respired CO2. Calibration to the δ13C Vienna Peedee Belemnite scale was by analysis of cylinder CO2 and CO2 derived from dissolved carbonate standards. The performance of gas-bag analysis was compared to continuous analysis where the WS-CRDS analyser was connected directly to the soil chamber. Although there are inherent difficulties in obtaining absolute accuracy data for δ13C values in soil-respired CO2, the similarity of δ13C values obtained for the same test soil with different analytical configurations indicated that an acceptable accuracy of the δ13C data were obtained by the WS-CRDS techniques presented here. Field testing of a variety of tropical soil/vegetation types, using the batch sampling technique yielded δ13C values for soil-respired CO2 related to the dominance of either C3 (tree, δ13C=−27.8 to−31.9 ‰) or C4 (tropical grass, δ13C=−9.8 to−13.6 ‰) photosynthetic pathways in vegetation at the sampling sites. Standard errors of the Keeling plot intercept δ13C values of soil-respired CO2 were typically7–9 μmol m−2 s−1).
- 16 January 2013
- Published by Taylor & Francis in Isotopes in Environmental and Health Studies
- Vol. 49 (2) , 232-242
Field-based cavity ring-down spectrometry of δ13C in soil-respired CO2
Measurement of soil-respired CO2 at high temporal resolution and sample density is necessary to accurately identify sources and quantify effluxes of soil-respired CO2. A portable sampling device for the analysis of δ13C values in the field is described herein. CO2 accumulated in a soil chamber was batch sampled sequentially in four gas bags and analysed by Wavelength-Scanned Cavity Ring-down Spectrometry (WS-CRDS). A Keeling plot (1/[CO2] versus δ13C) was used to derive δ13C values of soil-respired CO2. Calibration to the δ13C Vienna Peedee Belemnite scale was by analysis of cylinder CO2 and CO2 derived from dissolved carbonate standards. The performance of gas-bag analysis was compared to continuous analysis where the WS-CRDS analyser was connected directly to the soil chamber. Although there are inherent difficulties in obtaining absolute accuracy data for δ13C values in soil-respired CO2, the similarity of δ13C values obtained for the same test soil with different analytical configurations indicated that an acceptable accuracy of the δ13C data were obtained by the WS-CRDS techniques presented here. Field testing of a variety of tropical soil/vegetation types, using the batch sampling technique yielded δ13C values for soil-respired CO2 related to the dominance of either C3 (tree, δ13C=−27.8 to−31.9 ‰) or C4 (tropical grass, δ13C=−9.8 to−13.6 ‰) photosynthetic pathways in vegetation at the sampling sites. Standard errors of the Keeling plot intercept δ13C values of soil-respired CO2 were typically7–9 μmol m−2 s−1).
- 27 July 2012
- Published by Wiley in Hydrological Processes
- Vol. 26 (23) , 3630-3634
Extreme short‐term stable isotope variability revealed by continuous rainwater analysis
The continuous real‐time analysis, at 30‐s intervals, of precipitation at an Australian tropical location revealed extreme and rapidly changing δ18O and δD values related to variations in moisture source areas, transport paths and precipitation histories. The range of δ18O (−19.6‰ to +2.6‰) and δD (−140‰ to +13‰) values from 5948 measurements of nine rain events over 15 days during an 8‐month period at a single location was comparable with the range measured in 1532 monthly samples from all seven Australian Global Network of Isotopes in Precipitation stations from 1962 to 2002. Extreme variations in δ18O (−8.7‰ to −19.6‰) and δD (−54‰ to −140‰) were recorded within a single 4‐h period.Real‐time stable isotope monitoring of precipitation at a high temporal resolution enables new and powerful tracer applications in climatology, hydrology, ecophysiology and palaeoclimatology. Copyright © 2012 John Wiley & Sons, Ltd.
- 27 July 2012
- Published by Wiley in Hydrological Processes
- Vol. 26 (23) , 3630-3634
Extreme short‐term stable isotope variability revealed by continuous rainwater analysis
The continuous real‐time analysis, at 30‐s intervals, of precipitation at an Australian tropical location revealed extreme and rapidly changing δ18O and δD values related to variations in moisture source areas, transport paths and precipitation histories. The range of δ18O (−19.6‰ to +2.6‰) and δD (−140‰ to +13‰) values from 5948 measurements of nine rain events over 15 days during an 8‐month period at a single location was comparable with the range measured in 1532 monthly samples from all seven Australian Global Network of Isotopes in Precipitation stations from 1962 to 2002. Extreme variations in δ18O (−8.7‰ to −19.6‰) and δD (−54‰ to −140‰) were recorded within a single 4‐h period.Real‐time stable isotope monitoring of precipitation at a high temporal resolution enables new and powerful tracer applications in climatology, hydrology, ecophysiology and palaeoclimatology. Copyright © 2012 John Wiley & Sons, Ltd.
- 27 June 2012
- Published by Springer Nature in Environmental Chemistry Letters
- Vol. 10 (3) , 301-307
First continuous shipboard δ18O and δD measurements in sea water by diffusion sampling—cavity ring-down spectrometry
- 27 June 2012
- Published by Springer Nature in Environmental Chemistry Letters
- Vol. 10 (3) , 301-307
First continuous shipboard δ18O and δD measurements in sea water by diffusion sampling—cavity ring-down spectrometry
- 17 May 2012
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 68 (1) , 33-44
Phosphate amendment of metalliferous tailings, Cannington Ag–Pb–Zn mine, Australia: implications for the capping of tailings storage facilities
- 17 May 2012
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 68 (1) , 33-44
Phosphate amendment of metalliferous tailings, Cannington Ag–Pb–Zn mine, Australia: implications for the capping of tailings storage facilities