GLGabriela von Lewinski

Gabriela von Lewinski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gabriela von Lewinski has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Basic Science

    by G. von Lewinski, C. J. Wirth


  • Ex-vivo-µCT-Untersuchungen zu möglichen Mikrofrakturierungen des Hüftkopfs bei der Implantation eines zementfreien Oberflächenersatzes am Hüftgelenk

    by M. Lerch, G. Olender, N. von der Höh, F. Thorey, G. von Lewinski, A. Meyer-Lindenberg, H. Windhagen, C. Hurschler

    Studienziel: Als ein Grund eines möglichen Frühversagens des Oberflächenersatzes am Hüftgelenk werden häufig Schenkelhalsfrakturen am Übergang des Implantats zum Schenkelhals beobachtet. Als möglicher Versagensgrund werden Mikrofrakturen diskutiert, die iatrogen durch den Operateur beim Einschlagen des Implantats auf den Hüftkopf verursacht werden. Bei Untersuchungen von explantierten Femurköpfen nach Versagen wurden Kallusformationen gefunden, die auf den Zeitpunkt der Implantation zurückdatiert werden konnten und somit die Vermutung einer iatrogenen Frakturierung der Hüftkopfspongiosa zum Zeitpunkt der Implantation zuließen. In dieser Studie wurde der Einfluss des Impaktierens beim Einbringen einer unzementierten Kopfkappe auf den spongiösen Hüftkopf mikrotomografisch bezüglich Mikrofrakturierungen untersucht. Methodik: Mittels eines standardisierten Impulsgebers wurden nach Präparation von 20 paarigen humanen Hüftköpfen die unzementierten Kopfkappen der Firma ESKA Typ BS®| (ESKA Implants GmbH & Co., Lübeck) bei 9 Hüftköpfen mit 4,5 Kilonewton (kN) eingebracht. Bei 9 weiteren Proben erfolgte die Implantation per Hand. Ein Hüftkopf diente als Frakturmodell, 1 weiterer als Kontrolle. In einem Mikro-Computertomografen (µCT) wurden vor und nach der Impaktierung axiale Schichtaufnahmen der Hüftköpfe angefertigt. Für störungsfreie µCT-Untersuchungen der Hüftkopfspongiosa wurde eine aufklappbare Binnengeometrie der Kopfkappe angefertigt, die atraumatisch vom Hüftkopf entfernt werden konnte. Die CT-Datensätze vor und nach Impaktierung wurden verglichen und auf Mikrofrakturen untersucht. Ergebnisse: Per Hand und mit dem Impulsgeber reichten 20 Impulse zum festen Sitz und kompletten Setzen der Kopfkappe. Sowohl makroskopisch als auch in der zweidimensionalen Bildgebung waren keine Frakturen im Vergleich zu den Aufnahmen vor Implantation sichtbar. Schlussfolgerungen: Das Einschlagen mit einem definierten Impuls von 4,5 kN oder per Hand scheint – zumindest in der zweidimensionalen µCT-Bildgebung – nicht zu Frakturen der Hüftkopfspongiosa bei Implantation der untersuchten zementfreien ESKA-Kopfkappe Typ BS® zu führen. Aim: Microfractures of the femoral head during implantation of the femoral components are suspected to be a cause of fractures at the implant/neck junction which represent a common failure mode in hip resurfacing arthroplasty. Callus formation observed in femoral head retrievals suggests the occurrence of microfractures inside the femoral head, which might be inadvertently caused by the surgeon during implantation. The aim of this biomechanical study was to analyse whether or not the implantation of a cementless femoral component hip resurfacing system causes microfractures in the femoral head. Method: After the preparation of 20 paired human cadaveric femoral heads, the cementless femoral component ESKA Typ BS® (ESKA Implants GmbH & Co., Lübeck) was implanted on 9 specimens with an impaction device that generates 4.5 kN impaction force. On 9 specimens the femoral component was implanted by hand. One head was used as a fracture model, 1 specimen served as control without manipulation. The femoral component used for impaction was equipped with hinges to enable its removal without further interfering with the bone stock. Specimens were scanned with a µCT device before and after impaction and the µCT datasets before and after impaction were compared to identify possible microfractures. Results: Twenty strikes per hand or with the impaction device provided sufficient implant seating. Neither the macroscopic examination nor the 2-dimensional µCT analysis revealed any fractures of the femoral heads after impaction. Conclusion: At least macroscopically and in the 2-dimensional µCT analysis, implantation of the cementless hip resurfacing femoral component ESKA Typ BS® with 4.5 kN or by hand does not seem to cause fractures of the femoral head.


  • The Influence of Nonanatomical Insertion and Incongruence of Meniscal Transplants on the Articular Cartilage in an Ovine Model

    by Gabriela von Lewinski, Dieter Kohn, Carl Joachim Wirth, Djordje Lazovic

    Background: Adequate size matching and anatomically correct positioning must be recognized as essential factors influencing the outcome of meniscal transplantation. Hypothesis: Nonanatomical insertion and incongruence of meniscal transplants has an influence on the development of degenerative changes. Study Design: Controlled laboratory study. Methods: Ten female sheep were used for this animal study. Both knees (N = 20) were divided into 3 groups, subjected to either meniscectomy (group I; n = 10), to a medial meniscal autograft transplantation with a nonanatomical insertion of the anterior and posterior horn (group II; n = 5), or a meniscal autograft transplantation from the opposite knee as an incongruent meniscal autograft (group III; n = 5). After 6 months, radiographic (Fairbank's criteria), macroscopic (Jackson score), and histological evaluation by light microscopy (Mankin score) and scanning electron microscopy of the articular cartilage was performed. Results: All applied evaluation methods demonstrated that nonanatomical insertion of meniscal transplants resulted in the highest amount of degenerative cartilage changes. The histological assessment even revealed a significantly enlarged cartilage damage for the non-anatomic-positioned meniscal transplants in relation to the meniscectomized knees. Furthermore, the incongruent meniscal transplants demonstrated a significantly better cartilage situation than nonanatomically inserted meniscal transplants. Conclusion: The histological evaluation demonstrated clearly that a nonanatomically inserted meniscal transplant leads to degenerative cartilage changes that are worse than that after meniscectomy. Clinical Relevance: Precise anatomic positioning is mandatory for the potential chondroprotective effect of meniscal transplants.


  • Twenty‐year results of combined meniscal allograft transplantation, anterior cruciate ligament reconstruction and advancement of the medial collateral ligament

    by Gabriela von Lewinski, Klaus A. Milachowski, Karl Weismeier, Dieter Kohn, Carl Joachim Wirth

    The purpose of this study was to determine the objective and subjective long‐term outcomes of the first free meniscal allograft transplantations in five patients with complete absence or non‐repairable lesion of the medial meniscus after 20 years. Between 1984 and 1986 five patients underwent concomitant medial meniscal transplantation with a deep frozen meniscal allograft, ACL reconstruction and femoral advancement or temporary detachment of the MCL. The clinical outcome of the patients was evaluated 20 years postoperatively using clinical assessment, Lysholm‐score, KOOS, IKDC‐score, radiographs and magnetic resonance imaging. The Lysholm‐score ranged between 21 and 97 points of 100 maximal available points. Corresponding to this the total KOOS ranged between 28.4 and 91.1%. The results of the IKDC‐score were evaluated as nearly normal (B) (n = 2), abnormal (C) (n = 2) and severely abnormal (D) (n = 1). The radiological evaluation according to the Kellgren‐Lawrence classification showed an increase of the degenerative changes between one and four grades. The radiological results revealed clear degenerative changes with long‐term follow‐up after meniscal allograft transplantation even though some patients did relatively well regarding the subjective and clinical results in the 20‐year follow‐up examination in comparison with the literature. Despite these relative clear results the question if medial meniscal transplantation can protect against development of arthritis cannot definitely be answered because in this first case series some aspects of meniscus transplantation that have not been considered which turned out to be of importance during the last 20 years. Furthermore, it has to be taken into account that all patients revealed a cartilage damage at the time of surgery and an ACL reconstruction was performed in addition. Nevertheless from biomechanical point of view it might be taken into consideration to combine the medial meniscus transplantation at least with a high tibial osteotomy. Level of evidence was (IV, case series).


  • Experimental Measurement of Tibiofemoral Contact Area in a Meniscectomized Ovine Model Using a Resistive Pressure Measuring Sensor

    by G. von Lewinski, C. Stukenborg-Colsman, S. Ostermeier, C. Hurschler

    Animal models are necessary for the development and analysis of surgical techniques in meniscal surgery because they are the only means of preclinically determining the influence of biological factors such as healing processes and joint remodeling. Furthermore, little is known about the biomechanical effect of meniscectomy in sheep. The aim of the study was thus to investigate the efficacy of using a resistive pressure measuring sensor to quantify the effect of chronic meniscectomy in an ovine model. Twelve sheep were divided into two groups (n = 6): a sham operated control group (A), and a medially meniscectomized group (B). After six months, lower limb specimens were loaded with a joint-compressive force of 500 N during which the pressure measuring sensor was positioned underneath the meniscus to determine contact area, mean and peak contact pressure. A significant reduction in contact area of about 55% was observed in the meniscectomized knees compared to the controls. Peak contact pressure of the meniscectomized knees significantly increased an average of 260.4% compared to the control knees. Based on the results of this study, we conclude that the resistive pressure measuring sensors provide a means to experimentally measure tibiofemoral contact mechanics even in this relatively small (compared to human) animal model.


  • The Influence of Intraoperative Pretensioning on the Chondroprotective Effect of Meniscal Transplants

    by Gabriela von Lewinski, Thomas Pressel, Christof Hurschler, Frank Witte

    Background: Meniscal replacement has become more common in recent years. The meniscal transplant's ability to transfer load effectively depends on its ability to bear circumferential loading. Hypothesis: Intraoperative pretensioning on the meniscal transplant sutures has a positive influence on meniscal transplants’ chondroprotective effect. Study Design: Controlled laboratory study. Methods: Thirty-six sheep were divided into 6 groups (n = 6), subjected to a sham operation (group A), a meniscectomy (group B), or a meniscal autograft using tag sutures with different levels of pretensioning (group C, 0 N; group D, 20 N; group E, 40 N; group F, 60 N). Macroscopic (International Cartilage Repair Society score) and histologic evaluations (Mankin score) of the articular cartilage were performed after 6 months. Results: Higher suture pretension (40 N, 60 N) resulted in less cartilage degeneration than in meniscectomized (P= .047; P= .036) and nonpretensioned (P= .028; P= .015) knees, with International Cartilage Repair Society scores of 1.63 ± 0.57 and 1.66 ± 0.51 in groups E and F, respectively, and scores of 2.40 ± 0.27 and 2.68 ± 0.46 observed after meniscectomy and meniscal transplantation with no pretensioning, respectively. Group F had a significantly better Mankin score of 6.66 ± 2.15 (P= .05) compared with group D. Regarding criterion cells, trends toward less degeneration compared with meniscectomized and nonpretensioned knees (P= .054 and P= .055) were found. The coefficient of variation of the Mankin scores was greater than that of the International Cartilage Repair Society score. Group A had significantly better cartilage than all other groups. Conclusion: Adequate intraoperative pretensioning has a significant influence on the chondroprotective effect of meniscal transplants but did not prevent the development of articular cartilage degeneration. Clinical Relevance: The results suggest that intraoperative pretensioning could improve the chondroprotective effect of meniscal transplantation.


  • The influence of pre‐tensioning of meniscal transplants on the tibiofemoral contact area

    by G. von Lewinski, C. Hurschler, C. Allmann, C. J. Wirth

    The purpose of the present study was to determine the effect of biological in‐growth and pre‐tensioning on the load transmission function of meniscal transplants. The ability of meniscal transplants to transfer load to the tibial plateau was measured in an animal model. Thirty‐six sheep were divided into six groups: group A was the sham group, in group B a medial meniscectomy was performed, and in groups C–F a medial meniscal transplantation with an autograft was carried out. In groups C–F, different levels of pre‐tensioning force were applied via bone tunnel sutures (C=0, D=20, E=40, and F=60 N, respectively). The animals were killed after 6 months. The excised knees were mounted in a materials testing machine at 30, 60, and 90° of flexion, and loaded through the femoral axis to 500 N. A thin film pressure measuring transducer (K‐scan, Tekscan®) was positioned underneath the meniscus in the medial compartment in order to determine contact area and pressure. The mean contact pressure (MCP) of the sham group (A) and the groups with the transplanted meniscus (C–F) was significantly lower in relation to the meniscectomized knees (B). Significant increases in contact area and reductions in peak contact pressure were also observed. Only the meniscal transplantation group with 40 N (E) pre‐tension consistently showed a significant or strong trend toward increased contact area, compared to the meniscectomized knees (B) at all flexion angles tested. All meniscal transplanted groups with the exception of the 0 N group (C) showed a significant reduction in peak contact pressure in comparison to the meniscectomized group (B). The results indicate that meniscal transplantation reduces the MCP on the tibial plateau independent of the level of intraoperative pre‐tensioning. Furthermore, the menisci pre‐tensioned to 40 N showed significantly increased contact area and reduced peak contact pressure in comparison to the meniscectomized knees at all flexion angles tested, and revealed results similar to those reported in the literature for meniscal allografts fixated with bone plugs.