Dianping Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dianping Tang has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Hang Li
College of Resources and Environment, Southwest University, Chongqing, China
1 shared publication Jiayao Liao
Southwest University
1 shared publicationJingjing Ren
Key Laboratory of Analytical Chemistry (Chongqing), College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China
1 shared publication
Latest Publications
- 13 December 2008
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 6 (3) , 403-409
Ionic liquid and nanogold-modified immunosensing interface for electrochemical immunoassay of hepatitis B surface antigen in human serum
- 13 December 2008
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 6 (3) , 403-409
Ionic liquid and nanogold-modified immunosensing interface for electrochemical immunoassay of hepatitis B surface antigen in human serum
- 25 September 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (21) , 8064-8070
In Situ Amplified Electrochemical Immunoassay for Carcinoembryonic Antigen Using Horseradish Peroxidase-Encapsulated Nanogold Hollow Microspheres as Labels
Methods based on sandwich-type electrochemical enzyme immunoassay protocol have been extensively developed for the detection of biomolecules, but most often exhibit low detection signals and low detection sensitivity, and are unsuitable for routine use. In this study, we initially synthesized specially horseradish peroxidase-encapsulated nanogold hollow microspheres (HRP-GHS), and then the prepared HRP-GHS was conjugated to the secondary carcinoembryonic antibody (HRP-GHS-anti-CEA). Carcinoembryonic antigen (CEA), as a model protein, was monitored by using the electrochemical sandwich-type enzyme immunoassay format. Under optimized conditions, the linear range of the immunoassay by using single HRP-labeled anti-CEA (HRP-anti-CEA) as secondary antibodies is 2.5−120 ng/mL with a detection limit of 1.5 ng/mL CEA, while the assay sensitivity by using HRP-GHS-anti-CEA as secondary antibodies is further increased from 0.01 to 200 ng/mL with a lower detection limit of 1.5 pg/mL CEA. The intra- and interassay reproducibility is acceptable. The CEA concentrations of the clinical serum specimens assayed by the developed immunoassay show consistent results in comparison with those obtained by commercially available enzyme-linked immunosorbent assay. This immunoassay system has many desirable merits including sensitivity, accuracy, and little required instrumentation. Significantly, the new protocol may be quite promising, with potentially broad applications for clinical immunoassays.
- 25 September 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (21) , 8064-8070
In Situ Amplified Electrochemical Immunoassay for Carcinoembryonic Antigen Using Horseradish Peroxidase-Encapsulated Nanogold Hollow Microspheres as Labels
Methods based on sandwich-type electrochemical enzyme immunoassay protocol have been extensively developed for the detection of biomolecules, but most often exhibit low detection signals and low detection sensitivity, and are unsuitable for routine use. In this study, we initially synthesized specially horseradish peroxidase-encapsulated nanogold hollow microspheres (HRP-GHS), and then the prepared HRP-GHS was conjugated to the secondary carcinoembryonic antibody (HRP-GHS-anti-CEA). Carcinoembryonic antigen (CEA), as a model protein, was monitored by using the electrochemical sandwich-type enzyme immunoassay format. Under optimized conditions, the linear range of the immunoassay by using single HRP-labeled anti-CEA (HRP-anti-CEA) as secondary antibodies is 2.5−120 ng/mL with a detection limit of 1.5 ng/mL CEA, while the assay sensitivity by using HRP-GHS-anti-CEA as secondary antibodies is further increased from 0.01 to 200 ng/mL with a lower detection limit of 1.5 pg/mL CEA. The intra- and interassay reproducibility is acceptable. The CEA concentrations of the clinical serum specimens assayed by the developed immunoassay show consistent results in comparison with those obtained by commercially available enzyme-linked immunosorbent assay. This immunoassay system has many desirable merits including sensitivity, accuracy, and little required instrumentation. Significantly, the new protocol may be quite promising, with potentially broad applications for clinical immunoassays.