Jamshid Dehmeshki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jamshid Dehmeshki has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Hamdan Amin
3 shared publications- Salah Dine Qanadli
Lausanne University Hospital
3 shared publications Manlio Valdivieso
2 shared publications- Sarah Ann Barman
School of Computer Science and Mathematics, Kingston University, London, UK
2 shared publications - Tim Ellis
Quantitative Medical Imaging International Institutes, Faculty of Science, Engineering, and Computing, Kingston University, Kingston upon Thames, U.K.
2 shared publications - Xujiong Ye
University of Exeter
2 shared publications
Latest Publications
- Open Access
- 27 April 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (5) , 137
Three-Dimensional Adaptive Image Compression Concept for Medical Imaging: Application to Computed Tomography Angiography for Peripheral Arteries
Advances in computed tomography (CT) have resulted in a substantial increase in the size of datasets. We built a new concept of medical image compression that provides the best compromise between compression rate and image quality. The method is based on multiple contexts and regions-of-interest (ROI) defined according to the degree of clinical interest. High priority areas (primary ROIs) are assigned a lossless compression. Other areas (secondary ROIs and background) are compressed with moderate or heavy losses. The method is applied to a whole dataset of CT angiography (CTA) of the lower extremity vasculature. It is compared to standard lossy compression techniques in terms of quantitative and qualitative image quality. It is also compared to standard lossless compression techniques in terms of image size reduction and compression ratio. The proposed compression method met quantitative criteria for high-quality encoding. It obtained the highest qualitative image quality rating score, with a statistically significant difference compared to other methods. The average compressed image size was up to 61% lower compared to standard compression techniques, with a 9:1 compression ratio compared with original non-compressed images. Our new adaptive 3D compression method for CT images can save data storage space while preserving clinically relevant information.
- 27 April 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (5) , 137
Open AccessThree-Dimensional Adaptive Image Compression Concept for Medical Imaging: Application to Computed Tomography Angiography for Peripheral Arteries
Advances in computed tomography (CT) have resulted in a substantial increase in the size of datasets. We built a new concept of medical image compression that provides the best compromise between compression rate and image quality. The method is based on multiple contexts and regions-of-interest (ROI) defined according to the degree of clinical interest. High priority areas (primary ROIs) are assigned a lossless compression. Other areas (secondary ROIs and background) are compressed with moderate or heavy losses. The method is applied to a whole dataset of CT angiography (CTA) of the lower extremity vasculature. It is compared to standard lossy compression techniques in terms of quantitative and qualitative image quality. It is also compared to standard lossless compression techniques in terms of image size reduction and compression ratio. The proposed compression method met quantitative criteria for high-quality encoding. It obtained the highest qualitative image quality rating score, with a statistically significant difference compared to other methods. The average compressed image size was up to 61% lower compared to standard compression techniques, with a 9:1 compression ratio compared with original non-compressed images. Our new adaptive 3D compression method for CT images can save data storage space while preserving clinically relevant information.
- 2 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Fuzzy Systems
- Vol. 27 (8) , 1700
Corrections to “An Automatic Approach for Learning and Tuning Gaussian Interval Type-2 Fuzzy Membership Functions Applied to Lung CAD Classification System” [Apr 12 224-234]
- 2 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Fuzzy Systems
- Vol. 27 (8) , 1700
Corrections to “An Automatic Approach for Learning and Tuning Gaussian Interval Type-2 Fuzzy Membership Functions Applied to Lung CAD Classification System” [Apr 12 224-234]
- Open Access
- 1 July 2015
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 43, 64-77
Genetic algorithm based feature selection combined with dual classification for the automated detection of proliferative diabetic retinopathy
- 1 July 2015
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 43, 64-77
Open AccessGenetic algorithm based feature selection combined with dual classification for the automated detection of proliferative diabetic retinopathy
- Open Access
- 1 January 2014
- Published by IOS Press
- p. 1153-1157
Computer Aided Detection and Measurement of Peripheral Artery Disease
Computer-Aided Tomography Angiography (CTA) images are the standard for assessing Peripheral artery disease (PAD). This paper presents a Computer Aided Detection (CAD) and Computer Aided Measurement (CAM) system for PAD. The CAD stage detects the arterial network using a 3D region growing method and a fast 3D morphology operation. The CAM stage aims to accurately measure the artery diameters from the detected vessel centerline, compensating for the partial volume effect using Expectation Maximization (EM) and a Markov Random field (MRF). The system has been evaluated on phantom data and also applied to fifteen (15) CTA datasets, where the detection accuracy of stenosis was 88% and the measurement accuracy was with an 8% error.
- 1 January 2014
- Published by IOS Press
- p. 1153-1157
Open AccessComputer Aided Detection and Measurement of Peripheral Artery Disease
Computer-Aided Tomography Angiography (CTA) images are the standard for assessing Peripheral artery disease (PAD). This paper presents a Computer Aided Detection (CAD) and Computer Aided Measurement (CAM) system for PAD. The CAD stage detects the arterial network using a 3D region growing method and a fast 3D morphology operation. The CAM stage aims to accurately measure the artery diameters from the detected vessel centerline, compensating for the partial volume effect using Expectation Maximization (EM) and a Markov Random field (MRF). The system has been evaluated on phantom data and also applied to fifteen (15) CTA datasets, where the detection accuracy of stenosis was 88% and the measurement accuracy was with an 8% error.
- 28 March 2013
- Published by Springer Nature in Journal of Mathematical Imaging and Vision
- Vol. 48 (3) , 583-605
Planar Numerical Signature Theory Applied to Object Recognition
- 28 March 2013
- Published by Springer Nature in Journal of Mathematical Imaging and Vision
- Vol. 48 (3) , 583-605
Planar Numerical Signature Theory Applied to Object Recognition
- 31 March 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 27 (4) , 467-480
Segmentation of Pulmonary Nodules in Thoracic CT Scans: A Region Growing Approach
This paper presents an efficient algorithm for segmenting different types of pulmonary nodules including high and low contrast nodules, nodules with vasculature attachment, and nodules in the close vicinity of the lung wall or diaphragm. The algorithm performs an adaptive sphericity oriented contrast region growing on the fuzzy connectivity map of the object of interest. This region growing is operated within a volumetric mask which is created by first applying a local adaptive segmentation algorithm that identifies foreground and background regions within a certain window size. The foreground objects are then filled to remove any holes, and a spatial connectivity map is generated to create a 3-D mask. The mask is then enlarged to contain the background while excluding unwanted foreground regions. Apart from generating a confined search volume, the mask is also used to estimate the parameters for the subsequent region growing, as well as for repositioning the seed point in order to ensure reproducibility. The method was run on 815 pulmonary nodules. By using randomly placed seed points, the approach was shown to be fully reproducible. As for acceptability, the segmentation results were visually inspected by a qualified radiologist to search for any gross misssegmentation. 84% of the first results of the segmentation were accepted by the radiologist while for the remaining 16% nodules, alternative segmentation solutions that were provided by the method were selected.
- 31 March 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 27 (4) , 467-480
Segmentation of Pulmonary Nodules in Thoracic CT Scans: A Region Growing Approach
This paper presents an efficient algorithm for segmenting different types of pulmonary nodules including high and low contrast nodules, nodules with vasculature attachment, and nodules in the close vicinity of the lung wall or diaphragm. The algorithm performs an adaptive sphericity oriented contrast region growing on the fuzzy connectivity map of the object of interest. This region growing is operated within a volumetric mask which is created by first applying a local adaptive segmentation algorithm that identifies foreground and background regions within a certain window size. The foreground objects are then filled to remove any holes, and a spatial connectivity map is generated to create a 3-D mask. The mask is then enlarged to contain the background while excluding unwanted foreground regions. Apart from generating a confined search volume, the mask is also used to estimate the parameters for the subsequent region growing, as well as for repositioning the seed point in order to ensure reproducibility. The method was run on 815 pulmonary nodules. By using randomly placed seed points, the approach was shown to be fully reproducible. As for acceptability, the segmentation results were visually inspected by a qualified radiologist to search for any gross misssegmentation. 84% of the first results of the segmentation were accepted by the radiologist while for the remaining 16% nodules, alternative segmentation solutions that were provided by the method were selected.
- 1 September 2007
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 31 (6) , 408-417
Automated detection of lung nodules in CT images using shape-based genetic algorithm
- 1 September 2007
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 31 (6) , 408-417
Automated detection of lung nodules in CT images using shape-based genetic algorithm
- 1 June 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (3) , 759-767
Polyp Detection with CT Colonography: Primary 3D Endoluminal Analysis versus Primary 2D Transverse Analysis with Computer-assisted Reader Software
To retrospectively compare primary three-dimensional (3D) endoluminal analysis with primary two-dimensional (2D) transverse analysis supplemented by computer-assisted reader (CAR) software for computed tomographic (CT) polyp detection and reader reporting times. Ethical permission and patient consent were obtained from all donor institutions for use of CT colonography data sets. Twenty CT colonography data sets from 14 men (median age, 61 years; age range, 52-78 years) with 48 endoscopically proved polyps were selected. Polyp coordinates were documented in consensus by three unblinded radiologists to create a reference standard. Two radiologists read the data sets, which were randomized between primary 3D endoluminal views with 2D problem solving and 2D views supplemented by CAR software. Reading times and diagnostic confidence were documented. The CAR software highlighted possible polyps by superimposing circles on the 2D transverse images. Data sets were reread after 1 month by using the opposing analysis method. Detection rates were compared by using the McNemar test. Reporting times and diagnostic confidence were compared by using the paired t test and Mann-Whitney U test, respectively. Mean sensitivity values for polyps measuring 1-5, 6-9, and 10 mm or larger were 14%, 53%, and 83%, respectively, for 2D CAR analysis and 16%, 53%, and 67%, respectively, for primary 3D analysis. Overall sensitivity values were 41% for 2D CAR analysis and 39% for primary 3D analysis (P=.77). Reader 1 detected more polyps than reader 2, particularly when using the 3D fly-through method (P=.002). Mean reading times were significantly longer with the 3D method (P=.001). Mean false-positive findings were 1.5 for 2D analysis and 5.5 for 3D analysis. Reader confidence was not significantly different between analysis methods (P=.42). Two-dimensional CAR analysis is quicker and at least matches the sensitivity of primary 3D endoluminal analysis, with fewer false-positive findings.
- 1 June 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (3) , 759-767
Polyp Detection with CT Colonography: Primary 3D Endoluminal Analysis versus Primary 2D Transverse Analysis with Computer-assisted Reader Software
To retrospectively compare primary three-dimensional (3D) endoluminal analysis with primary two-dimensional (2D) transverse analysis supplemented by computer-assisted reader (CAR) software for computed tomographic (CT) polyp detection and reader reporting times. Ethical permission and patient consent were obtained from all donor institutions for use of CT colonography data sets. Twenty CT colonography data sets from 14 men (median age, 61 years; age range, 52-78 years) with 48 endoscopically proved polyps were selected. Polyp coordinates were documented in consensus by three unblinded radiologists to create a reference standard. Two radiologists read the data sets, which were randomized between primary 3D endoluminal views with 2D problem solving and 2D views supplemented by CAR software. Reading times and diagnostic confidence were documented. The CAR software highlighted possible polyps by superimposing circles on the 2D transverse images. Data sets were reread after 1 month by using the opposing analysis method. Detection rates were compared by using the McNemar test. Reporting times and diagnostic confidence were compared by using the paired t test and Mann-Whitney U test, respectively. Mean sensitivity values for polyps measuring 1-5, 6-9, and 10 mm or larger were 14%, 53%, and 83%, respectively, for 2D CAR analysis and 16%, 53%, and 67%, respectively, for primary 3D analysis. Overall sensitivity values were 41% for 2D CAR analysis and 39% for primary 3D analysis (P=.77). Reader 1 detected more polyps than reader 2, particularly when using the 3D fly-through method (P=.002). Mean reading times were significantly longer with the 3D method (P=.001). Mean false-positive findings were 1.5 for 2D analysis and 5.5 for 3D analysis. Reader confidence was not significantly different between analysis methods (P=.42). Two-dimensional CAR analysis is quicker and at least matches the sensitivity of primary 3D endoluminal analysis, with fewer false-positive findings.