Koji Sugano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Koji Sugano has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Osamu Tabata
Kyoto University
11 shared publications - Toshiyuki Tsuchiya
Department of Micro Engineering, Kyoto University, Kyoto, Japan
11 shared publications - Yoshikazu Hirai
Kyoto University
4 shared publications Junya Suzuki
Kyoto Univ
2 shared publicationsOsamu Tabata
Kyoto University
2 shared publications- Ahmed M. R. Fath El Bab
Mechatronics and Robotics Engineering Department, Innovation School, Egypt-Japan University of Science and Technology (EJUST), Alexandria 71111, Egypt
1 shared publication
Latest Publications
- 1 January 2015
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 135 (11) , 474-475
Fabrication and Characterization of Chain-like Arrangement of Gold Nanoparticles using Nanotemplates
- 1 January 2015
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 135 (11) , 474-475
Fabrication and Characterization of Chain-like Arrangement of Gold Nanoparticles using Nanotemplates
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2013, _J211017-1
J211017 Simple Fabrication of Free-Standing Silicon Nanowire Using Multi-Step ICP-RIE Process
The ultra high frequency resonator is one of the important components in RF MEMS. Silicon nanowire (SiNW) resonator vibrating at high frequencies, several hundred MHz, is expected to be applied for ultrahigh resolution sensor, quantum electromechanics and high speed logic devices. A fabrication method of free standing SiNW with high integration and high yield to give it mechanical freedom and integrate them with a MEMS device structure is strongly required for practical use of the SiNW resonator. This paper reports on two new simple fabrication methods for SiNWs using electron beam lithography, inductively coupled plasma reactive ion etching (ICP-RIE), and thermal oxidation. We succeeded in making freestanding bridge SiNWs with the width of 100 nm, the height of 100 nm, and the length ranged from 5 to 10 μm on Si substrate.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2013, _J211017-1
J211017 Simple Fabrication of Free-Standing Silicon Nanowire Using Multi-Step ICP-RIE Process
The ultra high frequency resonator is one of the important components in RF MEMS. Silicon nanowire (SiNW) resonator vibrating at high frequencies, several hundred MHz, is expected to be applied for ultrahigh resolution sensor, quantum electromechanics and high speed logic devices. A fabrication method of free standing SiNW with high integration and high yield to give it mechanical freedom and integrate them with a MEMS device structure is strongly required for practical use of the SiNW resonator. This paper reports on two new simple fabrication methods for SiNWs using electron beam lithography, inductively coupled plasma reactive ion etching (ICP-RIE), and thermal oxidation. We succeeded in making freestanding bridge SiNWs with the width of 100 nm, the height of 100 nm, and the length ranged from 5 to 10 μm on Si substrate.
- 14 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 21 (3) , 635-645
Micromachined Tactile Sensor for Soft-Tissue Compliance Detection
Compliance detection becomes very essential in minimally invasive surgery (MIS). It can help in detection of cancerous lumps and/or for deciding on tissue healthiness. In this paper, a micromachined piezoresistive tactile sensor, with two serpentine springs and 500-μm cubic mesas, has been designed for detecting the compliance of soft tissue independent of the applied distance between the sensor and the tissue. The measuring range of the sensor is chosen to be associated with the soft-tissue properties. The sensor parameters are optimized to give high sensitivity and linearity of the sensor output. The design is simulated using ANSYS for checking the sensor performance. Then, the sensor is fabricated and tested by three types of specimens, namely, specimen chips with known stiffness, silicone rubber specimens, and chicken organ specimens (leg and heart). For the specimen chips and silicone rubber specimens, the sensor distinguished between different stiffnesses independent of the applied displacement in the range of 50-200 μm. The sensor measured Young's modulus up to 808 kPa with an average error of ±7.25%. For the chicken leg and heart, the sensor distinguished between them under the applied displacement from 100 to 200 μm, and they were calculated as 12 ±1 kPa and 81 ±8 kPa, respectively.
- 14 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 21 (3) , 635-645
Micromachined Tactile Sensor for Soft-Tissue Compliance Detection
Compliance detection becomes very essential in minimally invasive surgery (MIS). It can help in detection of cancerous lumps and/or for deciding on tissue healthiness. In this paper, a micromachined piezoresistive tactile sensor, with two serpentine springs and 500-μm cubic mesas, has been designed for detecting the compliance of soft tissue independent of the applied distance between the sensor and the tissue. The measuring range of the sensor is chosen to be associated with the soft-tissue properties. The sensor parameters are optimized to give high sensitivity and linearity of the sensor output. The design is simulated using ANSYS for checking the sensor performance. Then, the sensor is fabricated and tested by three types of specimens, namely, specimen chips with known stiffness, silicone rubber specimens, and chicken organ specimens (leg and heart). For the specimen chips and silicone rubber specimens, the sensor distinguished between different stiffnesses independent of the applied displacement in the range of 50-200 μm. The sensor measured Young's modulus up to 808 kPa with an average error of ±7.25%. For the chicken leg and heart, the sensor distinguished between them under the applied displacement from 100 to 200 μm, and they were calculated as 12 ±1 kPa and 81 ±8 kPa, respectively.
- 1 January 2012
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 132 (9) , 320-321
Tensile Test on (110) Thin Film Single Crystal Silicon with Different Processing Conditions
- 1 January 2012
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 132 (9) , 320-321
Tensile Test on (110) Thin Film Single Crystal Silicon with Different Processing Conditions
- 21 May 2010
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 9 (6) , 1165-1174
Mixing speed-controlled gold nanoparticle synthesis with pulsed mixing microfluidic system
- 21 May 2010
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 9 (6) , 1165-1174
Mixing speed-controlled gold nanoparticle synthesis with pulsed mixing microfluidic system
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2010.8, 255-256
T0302-2-2 Local stress analysis of single-crystalline resonator using micro Raman spectroscopy
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2010.8, 255-256
T0302-2-2 Local stress analysis of single-crystalline resonator using micro Raman spectroscopy
- 11 April 2008
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 3 (3) , 268-273
Design of A Soft X‐ray Source with Periodic Microstructure Using Resonance Transition Radiation for Tabletop Synchrotron
- 11 April 2008
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 3 (3) , 268-273
Design of A Soft X‐ray Source with Periodic Microstructure Using Resonance Transition Radiation for Tabletop Synchrotron
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 16 (3) , 746-752
Versatile Method of Submicroparticle Pattern Formation Using Self-Assembly and Two-Step Transfer
We propose a method of submicroparticle pattern formation with high productivity, flexibility, and accuracy. The proposed process is composed of template-assisted self-assembly for particle self-assembly and a subsequent two-step transfer of the assembled particles. Optimization of the process parameters was performed by carrying out experiments to evaluate the effects of the parameters on the yields of each process. Polystyrene particles that are 500 nm in diameter were used, and a silicon wafer was used as a target substrate in the experiments that are described in this paper. In the self-assembly process, 70% of the pattern was successfully self-assembled on a silicon template substrate. In the first transfer step, a transfer yield of 79% was obtained with a self-assembled-monolayer-coated polydimethylsiloxane carrier substrate. In the second transfer step, a transfer temperature of 115 provided the maximum transfer yield of 85%. The overall process yield of 48% was achieved by the optimized process parameters, and it was successfully demonstrated that the proposed method can fabricate any submicroparticle pattern.
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 16 (3) , 746-752
Versatile Method of Submicroparticle Pattern Formation Using Self-Assembly and Two-Step Transfer
We propose a method of submicroparticle pattern formation with high productivity, flexibility, and accuracy. The proposed process is composed of template-assisted self-assembly for particle self-assembly and a subsequent two-step transfer of the assembled particles. Optimization of the process parameters was performed by carrying out experiments to evaluate the effects of the parameters on the yields of each process. Polystyrene particles that are 500 nm in diameter were used, and a silicon wafer was used as a target substrate in the experiments that are described in this paper. In the self-assembly process, 70% of the pattern was successfully self-assembled on a silicon template substrate. In the first transfer step, a transfer yield of 79% was obtained with a self-assembled-monolayer-coated polydimethylsiloxane carrier substrate. In the second transfer step, a transfer temperature of 115 provided the maximum transfer yield of 85%. The overall process yield of 48% was achieved by the optimized process parameters, and it was successfully demonstrated that the proposed method can fabricate any submicroparticle pattern.